• 제목/요약/키워드: evoked EMG

검색결과 40건 처리시간 0.026초

Efficacy of Intraoperative Facial Electromyographic Monitoring in Patients with Hemifacial Spasm

  • Park, Hae-Kwan;Jang, Kyung-Sool;Lee, Kyung-Jin;Rha, Hyung-Kyun;Joo, Won-Il;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권3호
    • /
    • pp.183-187
    • /
    • 2006
  • Objective : Hemifacial spasm has characteristic and specific electrophysiological finding, lateral spread response[LSR]. We study the correlation between change of lateral spread response during microvascular decompression[MVD] and clinical outcome after MVD. Methods : Sixty two patients with hemifacial spasm who were treated with microvascular decompression from March 2000 to February 2003 were included in this study. The monitoring of intraoperative facial electromyography[EMG] and brain stem auditory evoked potential were performed. Results : In 28 [44.7%] patients, there was persistence of lateral spread response after vascular decompression in root exit zone of facial nerve. Among these 28 patients, 9 had mild hemifacial spasm at discharge. Three out of 34 patients who had intraoperative disappearance of lateral spread response after MVD had mild hemifacial spasm. But Both groups, disappearance of LSR [Group I], and persistence [Group II] had only 2 patients with mild hemifacial spasm, and 5 patients at 3 months, respectively. Conclusion : Although intraoperative EMG monitoring is very useful in assessing the efficacy of MVD, the clinical outcome of MVD in patient with hemifacial spasm does not always correlate with EMG finding. The prognostic value of intraoperative LSR monitoring in the long-term results is questionable.

신경망을 사용한 뇌파 및 Artifact 자동 분류 (Automatic EEG and Artifact Classification Using Neural Network)

  • 안창범;이택용;이성훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.157-166
    • /
    • 1995
  • The Electroencephalogram (EEG) and evoked potential (EP) t;ave widely been used for study of brain functions. The EEG and EP signals acquired from multi-channel electrodes placed on the head surface are often interfered by other relatively large physiological signals such as electromyogram (EMG) or electroculogram (EOG). Since these artifact-affected EEG signals degrade EEG mapping, the removal of the artifact-affected EEGs is one of the key elements in neuro-functional mapping. Conventionally this task has been carried out by human experts spending lots of examination time. In this paper a neural-network based classification is proposed to replace or to reduce human expert's efforts and time. From experiments, the neural-network based classification performs as good as human experts : variation of decisions between the neural network and human expert appears even smaller than that between human experts.

  • PDF

Hemifacial Spasm : A Neurosurgical Perspective

  • Kong, Doo-Sik;Park, Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권5호
    • /
    • pp.355-362
    • /
    • 2007
  • Hemifacial spasm (HFS) is characterized by tonic clonic contractions of the muscles innervated by the ipsilateral facial nerve. Compression of the facial nerve by an ectatic vessel is widely recognized as the most common underlying etiology. HFS needs to be differentiated from other causes of facial spasms, such as facial tic, ocular myokymia, and blepharospasm. To understand the overall craniofacial abnormalities and to perform the optimal surgical procedures for HFS, we are to review the prevalence, pathophysiology, differential diagnosis, details of each treatment modality, usefulness of brainstem auditory evoked potentials monitoring, debates on the facial EMG, clinical course, and complications from the literature published from 1995 to the present time.

주의력이 동작으로 유발된 EEG 코히런스에 미치는 영향 (The effect of attention on EEG coherence evoked by movement)

  • 우진철;황민철;김종화;김치중;김용우;김지혜
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2009년도 춘계학술대회
    • /
    • pp.117-120
    • /
    • 2009
  • 본 연구는 손동작을 하였을 때 집중력이 EEG 코히런스(coherence)에 미치는 영향을 분석하였다. 신체에 이상이 없는 대학생 8 명이 시각 자극으로 제시되는 운동 작업을 지시하는 실험에 참여하였다. 실험 중 실시간으로 오른손의 요측 수굴근에 센서를 부착하여 EMG 를 측정하였고 국제 10-20 측정법에 의거한 C3 지점과 상하좌우로 2.5cm 떨어진 지점에 5 개의 전극을 부착하여 EEG 를 측정하였다. 운동영역간의 또는 운동영역과 비운동영역 사이의 코히런스 분석을 통하여 동작과 휴식을 구분해 주는 유의한 결과를 확인할 수 있었으나 개인에 따른 차이를 보였다. 유의한 차이를 보이는 코히런스 채널 쌍의 개수에 의해 강한 코히런스와 약한 코히런스로 그룹화 할 수 있었다. 개인별로 차이가 있는 EEG 코히런스의 결과는 동작시의 채널 별 EEG 의 상대적 출현량의 결과와 동일한 패턴을 가진 것으로 확인되어 주의력에 의한 영향임을 알 수 있었다.

  • PDF

척수 종양 제거 술 중 운동유발전위의 호전과 근력 호전의 관계 (Increased Intraoperative Motor Evoked Potentials and Motor Recovery after Spinal Cord Tumor Removal)

  • 표소은;박윤길;박진영;고유정
    • 대한근전도전기진단의학회지
    • /
    • 제20권2호
    • /
    • pp.98-105
    • /
    • 2018
  • Objective: To evaluate whether the increase of the amplitude of motor evoked potentials (MEPs) during surgery can imply favorable prognosis postoperatively in spinal cord tumor surgery. Method: MEPs were monitored in patients who underwent spinal cord tumor surgery between March 2016 and March 2018. Amplitude changes at the end of monitoring compared to the baselines in limb muscle were analyzed. Minimum and maximum changes were set to $MEP_{min}$ (%) and $MEP_{max}$ (%). Strengths of bilateral 10 key muscles which were documented a day before ($Motor_{pre}$), 48 h ($Motor_{48h}$) and 4 weeks ($Motor_{4wk}$) after the surgery were reviewed. Results: Difference of $Motor_{48h}$ from $Motor_{pre}$ ($Motor_{48h-pre}$) and $Motor_{4wk}$ from $Motor_{pre}$ ($Motor_{4wk-pre}$) positively correlated with $MEP_{min}$, suggesting that smaller the difference of MEPs amplitude, less recovery of muscle strength. There was a negative correlation between the amount of bleeding and $MEP_{min}$, indicating that the greater the amount of bleeding, the smaller the $MEP_{min}$, implying that MEPs amplitude is less likely to improve when the amount of bleeding is large. It also showed significant difference between patients with improved or no change of motor status and patients with motor deterioration after surgery according to anatomical tumor types. Conclusion: Improve of muscle strength was less when the increase of MEPs amplitude was small, and improvement of MEPs amplitude was less when the amount of bleeding was large. Correlation between changes of status of muscle strength after surgery and tumor types was observed. With amplitude increase in MEPs monitoring, restoration of muscle strength can be expected.

합곡(合谷) 침자극(鍼刺戟)이 동통억제(疼痛抑制)에 미치는 영향(影響) (Effects of Acupuncture at HapGuk$(LI_4)$ on Pain in Rats)

  • 황우준;박종주
    • Journal of Acupuncture Research
    • /
    • 제15권2호
    • /
    • pp.369-382
    • /
    • 1998
  • The purpose of this study was finding the pain inhibitory effect of acupuncture at $LI_4$. The pain at dentes incisivi was evoked by noxious electric stimulation and EMG changes based on the interval were measured. To do this, the opioid antagonist was administered intraperitoneally. Following are some of results. 1. The pain inhibitory effect of acupuncture at $LI_4$ was 94.35%, 84.56%, 57.62%, 54.40%, at 10, 20, 30 and 40 minutes respectively. All the data were calculated based on 100% at 0 minute. The effect was very significant at 40 minutes. 2. The continuous effect of acupuncture at $LI_4$ after taking out the needle was 58.58%, 57.62%, 66.22%, 73.18%, 83.70%, 92.68%, at 50, 50, 70, 80, 90 and 100 minutes respectively. The overall continuous effect was shown its maximum 20 minutes after taking out the needle and reached to the initial value at 60 minutes. 3. The pain inhibitory effect following the naloxone administration and acupuncture application at $LI_4$ was 95.96%, 96.04%, 94.86%, 94.92% at 10, 20, 30 and 40 minutes respectively. All values showed similar tendency to the initial data. 4. The continuous effect of acupuncture at $LI_4$ after taking out the needle which was preceded by the naloxone administration was 94.48%, 96.02%, 96.02%, 98.00%, 98.46%, 97.18% at 50, 60, 70, 80, 90 and 100 minutes respectively. This trend was not a significant fluctuation. It was concluded that effect of acupuncture at $LI_4$ was shown in conjunction with secretion of analgesic substance. Therefore it is implied that the acupuncture application will play a major role in treating many diseases with more revelation of scientific acupuncture mechanism. Further studies of acupuncture manipulation are needed in the future based on our study.

  • PDF

족삼리(足三里) 침자(鍼刺)가 동통억제(疼痛抑制)에 미치는 영향(影響) (Effects of Acupuncture at Chok-samni(ST36) on Pain in Rats)

  • 신권성;변재영;안수기;황우준
    • Journal of Acupuncture Research
    • /
    • 제15권2호
    • /
    • pp.287-300
    • /
    • 1998
  • The purpose of this study was finding the pain inhibitory effect of acupuncture at ST-36. The pain at dentes incisor was evoked by noxious electric stimulation and EMG changes based on time interval were measured. To do this, the opioid antagonist was administered intraperitoneally. Followings are some of the results. 1. The pain inhibitory effect of acupuncture at ST-36 was 93.82%, 87.00%, 75.30%, 69.76% at 10 20, 30 and 40 minutes respectively. All the data were calculated based on 100% at 0 minute. The effect was very significant at 40 minutes. 2. The continuous effect of acupuncture at ST-36 after taking out the needle was 77.46%, 79.66%, 87.60%, 91.50%, 95.14%, 99.48% at 50, 60, 70, 80, 90 and 100 minutes respectively. The overall continuous effect was shown its maximum 20 minutes after taking out the needle and reached to the initial value at 60 minutes. 3. The pain inhibitory effect following the naloxone administration and acupuncture application ST-36 was 93.44%, 94.58%, 90.80%, 88.04% at 10, 20, 30 and 40 minutes respectively. All values showed similar tendency to the initial data. 4. The continuous effect of acupuncture at ST-36 after taking out the needle which was preceded by the naloxone administration was 91.26%, 91.90%, 92.06%, 93.66%, 94.12%, 93.50% at 50, 60, 70, 80, 90 and 100 minutes respectively. This trend was not a significant fluctuation. It Was concluded that effect of acupuncture at ST-36 was shown in conjunction with secretion of analgesic substance. Therefore it is implied that the acupuncture application will play a major role in treating many diseases with more revelation of scientific acupuncture mechanism. Further studies of acupuncture manipulation are needed in the future based on our study.

  • PDF

저빈도 전기자극이 개의 치아 및 치은에 대한 동통억제효과 (THE INHIBITORY EFFECT OF LOW FREQUENCY ELECTRICAL STIMULATION ON THE DENTAL AND GINGIVAL PAIN OF DOG)

  • 권훈;송형근;이상호
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.525-536
    • /
    • 1996
  • The purpose of this study was to investigate the effect of electrical anesthesia induced by non-acupuncture point stimulation on inhibition of amplitude of digastric EMG evoked by noxious electrical stimuli in teeth and gingiva. Experiments were performed with dogs anesthetized with intraperitoneal pentobarbital sodium in an initial dose of 30mg/kg. Maintenance doses of 4.0ml/hour were given through a cannula in the femoral vein using a constant infusion pump. Anterior belly of digastric muscle was exposed and a pair of 0.1mm wire electrodes were inserted for E.M.G. recording. Bipolar electrodes were inserted into the labial and lingual surface of upper canine and the labial area of upper gingiva. Noxious stimuli were delivered to the tooth and gingiva through those electrodes by electric stimulator. Non-acupuncture point stimulation of 2Hz was delivered bilaterally to the femoral area. Amplitudes of digastric E.M.G. were measured from the oscilloscope and the monitor connected to amplifier at different intensities of electronic anesthesia of 1 volt, 4 volt and 10 volt. The inhibited rate of the amplitudes of digastric E.M.G. were analysed statistically with paired t-test. The following results were obtained : 1. Non-acupuncture point stimulation with intensities of 1 volt, 4 volt and 10 volt showed the inhibitory effect on pain of 15%, 25% and 16% in teeth and 15%, 18% and 12% in gingiva respectively 2. In tooth, statistical significance was observed between control and each group. In gingiva, there was statistical significance between control and group 1, 2 except group 3 From these results, low frequency electrical stimulation of non-acupuncture point resulted in reducing of dental and gingival pain, it could be used as adjunct to other pain control methods.

  • PDF

소세포폐암에 동반된 Eaton-Lambert Syndrome 1례 (Eaton-Lambert Syndrome with Small Cell Lung Cancer -A case report-)

  • 이경희;정문관;현명수;정재천;이현우;하정상;변영주
    • Journal of Yeungnam Medical Science
    • /
    • 제6권1호
    • /
    • pp.171-178
    • /
    • 1989
  • 저자들은 영남대학병원에 입원한 52세 남자환자로서 임상소견, 조직소견, 근전도 소견상으로 소세포폐암과 동반된 Eaton-Lambert 증후군으로 진단된 1례를 경험하였기에 문헌고찰과 함께 보고하는 바이다.

  • PDF

자화침 시스템을 이용한 경락전위 유발효과 및 근피로 회복 평가 (Evaluation of Muscle Fatigue Recovery Effect and Meridian Potential Change using Magnetic Acupuncture System)

  • 김수병;박선우;안순재;이나라;이승욱;민세은;김영호;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제29권1호
    • /
    • pp.83-92
    • /
    • 2012
  • Objectives : The purpose of this research was to develop the magnetic acupuncture system which used solenoid coil for magnetizing acupuncture needle. The system could generate the meridian electric potential (MEP) similar to the potential by manual acupuncture. Thus, we tried to confirm the therapeutic effect that is caused by the MEP generation. Methods : To confirm the MEP, we stimulated the magnetic acupuncture with at 2Hz, $92.7{\pm}2mT$, PEMFs (Pulsed Electro-Magnetic Fields) at ST37 and measured the evoked potential between ST36 and ST41. Also, we conducted a fatigue recovery test using isokinetic exercise in order to identify the therapeutic effect on musculoskeletal disorders. We chose LR9 as a stimulation point. To observe the state of fatigue, we measured the EMG and analyzed median frequency and peak torque for 20minutes. Results : We observed that MEP which incurred from magnetic acupuncture was higher than he reported MEP induced by manual acupuncture. Moreover, its modes were divided into two types by the direction of magnetic flux. When generating magnetic flux in the direction of acupoint, the positive peak voltage of the MEP was generated. In contrast, negative peak voltage of the MEP was generated whenever meganetic flux generated in the outward direction. As a result of fatigue recovery, the median frequency (MF) of the magnetic acupuncture group were recovered faster than that of the non-stimulation group. However, the peak torques of both groups were not restored until after 20 minutes. Conclusions : We confirmed that the magnetic acupuncture system can lead to the MEP similar to manual acupuncture. Moreover, the MEP had a therapeutic effect on the musculoskeletal disorders.