• Title/Summary/Keyword: evaporation condition

Search Result 323, Processing Time 0.02 seconds

Numerical study of heat and mass transfer around an evaporative condenser tube by multi-zone method (다중 영역법을 이용한 증발식 응축관 주위의 열 및 물질전달 해석)

  • ;;Yun, In-Chul;Yoo, Je-In
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.12
    • /
    • pp.3317-3328
    • /
    • 1995
  • The objective of the present study is to predict the characteristics of heat and mass transfer around an evaporative condenser. Numerical calculations have been performed using multi-zone method to investigate heat transfer rate and evaporation rate with the variation of inlet condition(velocity, relative humidity and temperature) of the moist air, the flow rate of the cooling water and the shape of the condenser tube. From the results it is found that the profile of heat flux is the same as that of evaporation rate since heat transfer along the gas-liquid interface is dominated by the transport of latent heat in association with the vaporization(evaporation) of the liquid film. The evaporation rate and heat transfer rate is increased as mass flow rate increases or relative humidity and temperature decrease respectively. But the flow rate of the cooling water hardly affect the evaporation rate and heat flux along the gas-liquid interface. The elliptic tube which the ratio of semi-minor axis to semi-major axis is 0.8 is more effective than the circular tube because the pressure drop is decreased. But the evaporation rate and heat flux shown independency on the tube shape.

Analysis of the Rankine Cycle Including Heat Exchange Processes (熱交換 過程을 考慮한 랜킨 사이클의 性能解析)

  • 정평석;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.1
    • /
    • pp.150-156
    • /
    • 1986
  • A Rankine cycle including heat exchange processes in the steam generator has been analyzed by the concept of available energy. The operation condition of the cycle can be expressed with the evaporation temperature, and there exists an optimum power condition at which the thermal efficiency of the cycle is almost the same as that of the Carnot cycle at the maximum power condition. The mass flow rate of the working fluid increases sharply as the evaporation temperature approaches to the critical point, and the regenerative system is needed to operate the cycle at the maximum power condition.

Analytical Study of heat Transfer in Evaporative Cooling of a Porous Layer (다공층의 증발냉각 열전달에 관한 해석적 연구)

  • 김홍제;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.104-111
    • /
    • 1992
  • In this study, the heat transfer characteristics of the evaporative transpiration cooled system is analytically investigated considering the occurrence of the two-phase evaporation zone. Under the condition of the external heat input, analytical solutions of the three regions (i.e., vapor, liquid and two-phase evaporation zone) are respectively obtained using the matching conditions for the steady-state problem where properties are constant. As results, the length of the evaporation zone increases with increasing heat input and with decreasing mass flow rate. It also increases with increasing particle size, system porosity, thermal conductivity of material, inlet temperature and latent heat of coolant. The position of the lower interface of the evaporation zone have a lot of efforts on the evaporation zone length, the position of the upper interface penetrates deeper into the porous layer with lower thermal conductivity of porous material, higher system porosity and larger particle size.

Synthesis and Characterization of Alumina Composite Membrane by Al Evaporation and Thermal Oxidation (알루미늄의 진공증발과 열산화에 의한 알루미나 복합분리막의 제조 및 특성분석)

  • 이동호;최두진;현상훈
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.3
    • /
    • pp.349-358
    • /
    • 1995
  • The ceramic composite membrane was synthesized by thermal oxidation after evaporation of Al on the support prepared by slip casting process. Oxidation was performed at $700^{\circ}C$ and 80$0^{\circ}C$ under dry oxygen atmosphere. It was considered as optimum oxidation condition that the membrane showed a knudsen behaviro. A further oxidation resulted in an increase of gas permeability because top layer became densified. Then, a multi-layered composite membrane was synthesized through a sol-gel method, evaporation and thermal oxidation of Al coating processes. While the membrane was thermally stable up to 80$0^{\circ}C$, gas permeability was rapidly decreased even at a slight amount of deposition of Al.

  • PDF

Evaluation of the Creep Properties of High Strength Concrete according to Moisture Evaporation and Compressive Strength (수분증발조건 및 압축강도에 따른 고강도콘크리트의 크리프 특성 평가)

  • Bae, Chang-O;Kim, Gyu-Yong;Ham, Eun-Young;Koo, Kyung-Mo;Kim, Hong-Seop;Yoon, Min-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.75-76
    • /
    • 2012
  • In this study, it was evaluated about creep properties of high strength concrete according to compressive strength and moisture evaporation condition. As a results, creep strain and creep coefficient was greatly affected by moisture evaporation conditions rather than compressive strength. Also, the effect of fiber mixed was not show big difference.

  • PDF

Numerical Analysis on Removal Efficiency of Water Droplets in a Curved Vane Mist Eliminator with Consideration of Evaporation and Condensation at Surface of Droplets (액적 표면에서 증발 및 응축을 고려한 곡면 형상 액적 제거장치의 제거 효율에 대한 수치 해석)

  • Song, Dong Keun
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.135-143
    • /
    • 2016
  • Removal of water contents in a gas is needed in industrial field of gas processing related on energy production/conversion, and environmental treatment. Inertial separators are economic devices for separating droplets from the gas stream. For accurate understanding of removal process in a curved vane mist eliminator, a numerical model including turbulent dispersion, evaporation and condensation of water vapor at surface of droplets is required. A two-stage curved vane mist eliminator has been modeled, and fluid flow of mixture of air and water vapor and droplet trajectories were solved simultaneously with taking into account two-way coupling. Removal efficiency of droplets with various inlet condition of relative humidities (RH, 40%, 90%, and 100%) were compared. As RH increased, the effect of evaporation decreased and inertial separation efficiencies of droplets obtained increased especially for droplets of diameter below 10 micrometers.

Evaporating Particle Behaviors and plasma Parameters by Spectroscopic Method in laser Welding (레이저 용접시 분광학적 수법에 의한 증발입자의 거동과 플라즈마 물성의 계측)

  • 김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.514-522
    • /
    • 1999
  • The laser-induced plasma affects greatly on the results of welding process. moreover selective evaporation loss of alloying elements leads to change in chemical composition of weld metal as well as the mechanical properties of welded joint. this study was undertaken to obtain a fundamental knowledge of pulsed laser welding phenomena especially evaporation mechanism of different aluminum alloys. The intensities of molecular spectra of AlO and MgO were different each other depeding on the power density of a laser beam Under the low power density condition the MgO band spectrum was predominant in intensity while the AlO spectra became much stronger with an increase in the power density. These behaviors have been attributed to the difference in evaporation phenomena of Al and Mg metals with different boiling points and latent heats of vaporization. The time-averaged plasma temperature and electron number density were determined by spectroscopic methods and consequently the obtained temperature was $3,280{\pm}150K$ and the electron number density was $1.85{\times}10^{19}\;l/m^3$.

  • PDF

Operation Condition and Characteristics for Treatment of Piggery Slurry using Thermophilic Aerobic Oxidation System (축산분뇨 처리에 적용된 급속액상부숙기술(TAO system)의 운전특성과 운전조건)

  • 이명규;이원일
    • Journal of Animal Environmental Science
    • /
    • v.6 no.3
    • /
    • pp.161-168
    • /
    • 2000
  • The study exploited TAO system for the treatment of piggery slurry and aimed to draw characteristics and conditions of the reactor by differentiating the number of air input pump and foam cutter. The results are: 1. Under different operation condition, Run-3 with three air input pumps and four foam cutters showed the highest efficiency in the change of water level and temperature; 40-70cm and 45-55$^{\circ}C$, respectively. 2. Evaporation volume in Run-3 was the highest; 55.5l/$m^2$ . day in Run-1, 75.0/$m^2$ . day in Run-2, and 120.3/$m^2$ . day in Run-3. 3. Throughout the experimental period, temperature inside the reactor was maintained at around 5$0^{\circ}C$, regardless of seasonal temperature changes.

  • PDF

Effects of climate condition on concrete slab with modified-latex (외기조건이 개질된 라텍스 혼입콘크리트 슬래브 표면에 미치는 영향)

  • Cha, Hun;Kim, Dae-Geon;Choi, Sang-Hwan;Moon, Kyeong-Sik
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.7-8
    • /
    • 2014
  • Latex-modified concrete using ready mix concrete (R-LMC) was developed for application of building construction project (specifically, the rooftop of a parking garage unable to use heavy equipments for bridge deck overlay) due to three major outstanding properties of R-LMC; bond strength, resistance of cracks at early age, and resistance of freezing and thawing. However, R-LMC at the placement stage is required to be sufficiently cured because R-LMC is very sensitive to rate of evaporation of surface moisture. This study focused on effects of different curing methods and climate condition on cracks on the surface of hardened R-LMC considering the chart of rate of evaporation of surface moisture from concrete provided by American Concrete Institute in manual for placement of latex modified concrete.

  • PDF

Estimation of Evaporation Rate of Swine Slurry Using the Natural Evaporation System(NES) in summer (여름철 자연증발시스템(NES)의 腞슬러리 증발효율 평가)

  • Kim, K.Y.;Choi, H.L.;Kim, J.G.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.459-474
    • /
    • 2002
  • The purpose of this study was to establish the optimal operation condition of the natural evaporation system(NES) which was used for reducing swine slurry. Especially the main point of this study is to estimate the effect of climate condition(clear & rainy) and spray type(batch & flow) for the evaporation rate of swine slurry applying the NES in summer. Experiment was performed from June to August, which was generally regarded as summer in Korea, with the spray type of batch in 2000 and that of flow in 2001. As a result of experiment for batch and flow type, the averaged evaporation rate was measured into 2.71 and 3.59 l/ton . $m^2$ . day on clear days and 0.62 and 0.66 l/ton . $m^2$ . day on raint days, respectively. Based on the calculated evaporation rate by the climate condition and the spray type, it was proved that the averaged reduction rate for total input(1t/day) were 15.99% and 3.19% on clear and rainy days and the evaporation rate of the flow type was superior to that of the batch type by 5%, approximately. Therefore, it was concluded that the supplementary equipment, such as fan, should by operated in rainy days and the spray type of flow rather than that of batch should be recommended to increase the evaporation rate in the natural evaporation system(NES).