• Title/Summary/Keyword: evaporation characteristics

Search Result 926, Processing Time 0.034 seconds

The physicochemical characteristics and antioxidant capacities of commercial tea products from Phellinus baumii, Ganoderma lucidum (상황버섯과 영지버섯 차류 제품의 이화학적 특성 및 항산화능)

  • Kim, Ha-Na;Son, Eun Ji;Chung, Shin-Kyo
    • Food Science and Preservation
    • /
    • v.24 no.1
    • /
    • pp.153-157
    • /
    • 2017
  • This study was conducted to investigate the physicochemical characteristics, antioxidant capacities of Phellinus linteus and Ganoderma lucidum commercial tea products. The physicochemical characteristics included pH, Hunter's color values, soluble solid contents, evaporation residues, and ${\beta}$-glucan contents. The antioxidant capacities were measured by 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activities, ferric reducing antioxidant power (FRAP), and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) radical scavenging activities, total phenolic contents (TPC), and total flavonoid contents (TFC). The pH, soluble solid contents, evaporation residues, and ${\beta}$-glucan contents were in the range of 4.43-7.05, $0.40-0.73^{\circ}Brix$, 62.04-258.84 mg/100 g, and 15.51-62.32 mg%, respectively. Hunter's color values (L, a, and b) indicated 41.76-55.02, -0.49-5.06, and 17.41-28.32, respectively. The antioxidant capacities showed $32.63-367.81{\mu}M$ GAE (DPPH radical scavenging activities), $321.86-1,035.19{\mu}M$ TE (FRAP), $703.50-1,091.83{\mu}M$ (ABTS radical scavenging activities), $286.56-916.00{\mu}M$ (TPC), and $85.33-635.33{\mu}M$ (TFC). Overall, P. linteus liquid tea 2 (PL2) and G. lucidum liquid tea 1 (GL1) showed high antioxidant capacities (p<0.05). The TPC and TFC were highly correlated with DPPH radical scavenging activities, FRAP, and ABTS radical scavenging activities (r=0.7298-0.9743), but the ${\beta}$-glucan contents were not correlated well with antioxidant activities tested (r=0.3146-0.6663).

Basic Study of Spray-Behavior Characteristics of Emulsified Fuel (에멀젼연료의 분무거동특성에 관한 기초연구)

  • Yeom, Jeong Kuk;Yoon, Jeong Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.763-771
    • /
    • 2014
  • As a preliminary study on the spray behavior characteristics of emulsified fuel, the fuel properties (viscosity, surface tension, and density) and evaporation characteristics of a fuel droplet were investigated. The emulsified fuel was made by mixing diesel and $H_2O_2$. In addition, the macroscopic spray behavior characteristics such as the spray penetrations and spray angles of the emulsified and diesel fuels were compared. The stirring condition of the emulsified fuel was a 9:1 mixture of the diesel fuel and the surfactant span 80. The mixing ratios for the hydrogen peroxide were set at EF2, EF12, EF22, EF32, EF42, EF52, EF62, EF72, EF82, and EF92. The injection pressures were set at 400, 600, 800, and 1000 bar. We found that as the mixing ratio of the hydrogen peroxide was increased from EF2 to EF52, the viscosity of the emulsified fuel increased. However, afterward, the viscosity of the emulsified fuel gradually decreased and approached the viscosity value of the diesel fuel. Therefore, generally oil-in-water emulsions were used for the hydrogen peroxide mixing ratios up to 52 (EF52), and water-in-oil emulsions were used for the hydrogen peroxide mixing ratios above 52. Finally, the spray behavior characteristics (spray penetration and spray angle) of the emulsified fuel were found to be almost independent of the mixing ratio.

A Study on Combustion Characteristics for Dry Food Waste (음식폐기물의 고형연료화를 위한 연소특성 연구)

  • Sang, Byoungchan;Lee, Seungjeong;Lee, Doyeon;Ohm, Taein
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.30 no.4
    • /
    • pp.101-108
    • /
    • 2022
  • This study analyzed the physicochemical properties and combustion characteristics of dry food waste to evaluate the possibility of using food waste as a solid refuse fuel (SRF). The characteristics of dry food waste as a fuel were analyzed by comparing the difference in properties with SRF, and the combustion characteristics after conversion into fuel were identified. Ultimate analysis, proximate analysis, calorific value analysis, and TGA analysis were conducted using two types of food waste and two types of SRF, and the following results were obtained. The moisture content and ash content of dry food waste were 1.7~10.0 wt.% and 7.8~11.7 wt.%, respectively, which satisfied the quality standards for SRF. The low calorific value of dry food waste was 4,000 ~ 4,720 kcal/kg, which was higher than the quality standard of 3,500 kcal/kg for SRF. As a result of TGA analysis of dry food waste, the combustion reaction started at about 200 ℃ and the highest burning rate was at about 500 ℃. After moisture evaporation between 100 and 200 ℃, initial volatile matter, carbon and residual volatile matter were released and burned between 200 and 500 ℃. Based on the high calorific value and low moisture and ash content of dry food waste, it is considered that it is possible to convert dry food waste into SRF through the application of efficient drying technology and strict quality standard inspection in the future.

Drainage Performance of Various Subsurface Drain Materials- (배수개선공법개발에 관한 연구(I) -각종 지하배수용 암거재료의 배수성능-)

  • 김철회;이근후;유시조;서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.3
    • /
    • pp.104-120
    • /
    • 1979
  • I. Title of the Study Studies on the Development of Improved Subsurface Drainage Methods. -Drainage Performance of Various Subsurface Drain Materials- II. Object of the Study Studies were carried out to select the drain material having the highest performance of drainage; And to develop the water budget model which is necessary for the planning of the drainage project and the establishment of water management standards in the water-logged paddy field. III. Content and Scope of the Study 1. The experiment was carried out in the laboratory by using a sand tank model. The drainage performance of various drain materials was compared evaluated. 2. A water budget model was established. Various parameters necessary for the model were investigated by analyzing existing data and measured data from the experimental field. The adaptability of the model was evaluated by comparing the estimated values to the field data. IV. Results and Recommendations 1. A corrugated tube enveloped with gravel or mat showed the highest drainage performance among the eight materials submmitted for the experiment. 2. The drainage performance of the long cement tile(50 cm long) was higher than that of the short cement tile(25 cm long). 3. Rice bran was superior to gravel in its' drain performance. 4. No difference was shown between a grave envelope and a P.V.C. wool mat in their performance of drainage. Continues investigation is needed to clarify the envelope performance. 5. All the results described above were obtained from the laboratory tests. A field test is recommended to confirm the results obtained. 6. As a water balance model of a given soil profile, the soil moisture depletion D, could be represented as follows; $$D=\Sigma\limit_{t=1}^{n}(Et-R_{\ell}-I+W_d)..........(17)$$ 7. Among the various empirical formulae for potential evapotranspiration, Penman's formular was best fit to the data observed with the evaporation pans in Jinju area. High degree of positive correlation between Penman;s predicted data and observed data was confirmed. The regression equation was Y=1.4X-22.86, where Y represents evaporation rate from small pan, in mm/100 days, and X represents potential evapotranspiration rate estimated by Penman's formular. The coefficient of correlation was r=0.94.** 8. To estimate evapotranspiration in the field, the consumptive use coefficient, Kc, was introduced. Kc was defined by the function of the characteristics of the crop soil as follows; $Kc=Kco{\cdot}Ka+Ks..........(20)$ where, Kco, Ka ans Ks represents the crop coefficient, the soil moisture coefficient, and the correction coefficient, respectively. The value of Kco and Ka was obtained from the Fig.16 and the Fig.17, respectively. And, if $Kco{\cdot}Ka{\geq}1.0,$ then Ks=0, otherwise, Ks value was estimated by using the relation; $Ks=1-Kco{\cdot}Ka$. 9. Into type formular, $r_t=\frac{R_{24}}{24}(\frac{b}{\sqrt{t}+a})$, was the best fit one to estimate the probable rainfall intensity when daily rainfall and rainfall durations are given as input data, The coefficient a and b are shown on the Table 16. 10. Japanese type formular, $I_t=\frac{b}{\sqrt{t}+a}$, was the best fit one to estimate the probable rainfall intensity when the rainfall duration only was given. The coefficient a and b are shown on the Table 17. 11. Effective rainfall, Re, was estimated by using following relationships; Re=D, if $R-D\geq}0$, otherwise, Re=R. 12. The difference of rainfall amount from soil moisture depletion was considered as the amount of drainage required. In this case, when Wd=O, Equation 24 was used, otherwise two to three days of lag time was considered and correction was made by use of storage coefficient. 13. To evaluate the model, measured data and estimated data was compared, and relative error was computed. 5.5 percent The relative error was 5.5 percent. 14. By considering the water budget in Jinju area, it was shown that the evaporation amount was greater than the rainfall during period of October to March in next year. This was the behind reasonning that the improvement of surface drainage system is needed in Jinju area.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001- (공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 -)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

Physicochemical Characteristics of Sangju Traditional Dried Persimmons during Drying Process (상주 전통곶감의 제조과정 중 이화학적 품질특성)

  • 강우원;김종국;오상룡;김준한;한진희;양진무;최종욱
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.386-391
    • /
    • 2004
  • This study was performed to investigate change of quality characteristics on traditional dried Persimmons from Sangju varity regions (sun-dried, Namjang and Bokryong). Moisture contents on drying were decreased and constant at from 7th to 14th days drying periods and its periods were recognized to constructing second peel of dried persimmons. Constructed second peel were affected on quality characteristics of traditional dried Persimmons. Also, in case of semi-dried persimmons were processed at 45∼55% level of moisture content. Final products of semi -dried persimmons were estimated in 25th from initial drying periods. Changes of water activity were increased reducing speed at time of water content decreased, second feel constructing during drying persimmons were introduced to decreasing of water activity. Weights of dried Persimmons were quickly decreased in 21th drying periods and slowly decreased after that time. Weight changing and water evaporation of dried persimmons at the Namjang and Bokryong were slowy decreased and controled after 7∼14th in periods of constructing second feel of dried persimmons. Change of brix in dried persimmons have had in 18∼27% value at initial drying periods and quickly increased after 7∼14th in drying periods and have in high value of 40∼50% at 21th drying periods. At the texture of dried persimmons, hardness were decresed after 7∼14th in periods and effected on decreasing of water content, increasing of drying times. Sensory score of dried persimmons were highest score of color, sweetness and texture at dried persimmons of Namjang. Score of astringency, sourness and mold smell were highest at dried persimmons of Bokryong. Value of highest overall acceptance score was at dried Persimmons of Namjang.

The Combustion Characteristics of Residual Fuel oil Blended with Fuel Additives (잔사유용 연료첨가제 함유 선박 연료유의 연소특성 연구)

  • Jang, Se-Hyun;Lee, Kyoung-Woo;Kim, Jeong-Ryul;Kim, Jong-Ho;Yoon, Seok-Hun;Cho, Ik-Soon;Choi, Jae-Hyuk
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.554-563
    • /
    • 2016
  • Ships are capable of operating on residual fuel oil. Recently, various attempts have been made to meet environmental regulations and with ships operating on residual fuel oil. One way of fulfilling these requirements is by using fuel additives. Dispersants and fuel combustion improvers will have a positive effect on improving the combustion characteristics of the residual fuel oil. As such, this study examines fuel oils blended with additives by using fuel combustion analysis (FIA/FCA) and thermogravimetric analysis (TGA). The results of FIA/FCA focuse only on the amount of work done by the fuel oil. Therefore, it is recommended in this study that a new method to evaluate the combustion efficiency via FIA/FCA processes be developed. The analysis with ROHR curve gained by FIA/FCA brought similar results with pressure trace curve therefore it can be said that new analysis method can be reliable. The TGA, analysis process is very sensitive to the evaporation of fuel, for example, which could be addressed. In the performance-related findings of this study, blended samples with additives containing iron compounds showed a greater improvement in early combustion characteristics than samples without additives.

Characteristics of Sawdust and Cocopeat Beddings, and Their Usefulness According to the Fan and Pen Location for Rearing Hanwoo Cattle

  • Ahn, Gyu Chul;Jang, Sun Sik;Lee, Kang Yeon;Kwak, Wan Sup;Oh, Young Kyun;Park, Keun Kyu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.3
    • /
    • pp.444-454
    • /
    • 2016
  • This study was designed to examine the characteristics of sawdust and cocopeat bedding materials, including physicochemical properties (Exp. I) and on-farm trial (Exp. II). In Exp. I, the proportion of particle size was in the order of sawdust>cocopeat India>cocopeat Vietnam (p<0.05), and cocopeat contained higher proportion of small particles ($250{\mu}m$+below $250{\mu}m$) than sawdust, causing a dust production problem. Bulk density was cocopeat India>cocopeat Vietnam>sawdust (p<0.05), thus cocopeat treatments showed 4.4 times higher bedding cost than sawdust. The water absorption rates were 702.0% in cocopeat India, 678.3% in cocopeat Vietnam, and 444.0% in sawdust, showing cocopeat had approximately 1.5 times higher water absorption rate than sawdust. Moisture evaporation rates after 12 h of air blowing (2.00 m/s) were higher (p<0.05) in cocopeat Vietnam (80.4%) than sawdust (71.2%) and cocopeat India (72.8%). In vitro ammonia emissions were higher (p<0.05) in sawdust ($2.71mg/m^2/h$) than cocopeat India ($1.59mg/m^2/h$) and Vietnam ($1.22mg/m^2/h$), and total ammonia emissions were higher (p<0.05) in sawdust ($37.02mg/m^2$) than cocopeat India ($22.51mg/m^2$) and Vietnam ($13.60mg/m^2$). In Exp. II, an on-farm trial was conducted with 48 Hanwoo cattle in 16 pens using the same bedding materials as in Exp. I, with fan (blowing 2.00 m/s) and no fan treatments, and feed bunk side (FB) and water supply side (WS) within a pen (4.5 m, $width{\times}9.0m$, length). Beddings were replaced with fresh bedding materials when moisture concentrations were over 65%. No interactions among treatments were detected for moisture concentration and increment rates, and ammonia concentrations, but a significant effect was observed (p<0.01) for each of the treatments. Both concentrations and increment rate of moisture were higher (p<0.01) in the beddings without fan than with fan. Moisture concentrations and increment rate within a pen were also higher (p<0.01) in FB than WS. Thus, the whole no-fan-FB and sawdust-fan-FB were replaced with fresh bedding material between 4 to 5 experimental weeks. The ammonia concentrations and pH of beddings were not significantly different among treatments. Therefore, using cocopeat bedding with a blowing fan can extend twice the bedding utilization period, and WS within a pen showed twice the bedding-life compared to FB. Despite the outstanding characteristics of cocopeat compared with sawdust, using cocopeat as an alternative for sawdust bedding is not recommended for cattle management, considering it has 4.4 times higher bedding cost and a dust production problem.

Experimental Study of Evaporative Heat Transfer Characteristics of R-134a with Channel-Bending Angle in Microchannel Heat Exchangers (마이크로채널 열교환기에서 채널 굽힘 각도에 따른 R-134a의 증발열전달 특성에 관한 연구)

  • Lee, Hae-Seung;Jeon, Dong-Soon;Kim, Young-Lyoul;Kim, Seon-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.635-642
    • /
    • 2010
  • Experimental investigations have been carried out to examine the evaporative heat transfer characteristics of R-134a with the channel-bending angle (CBA) in microchannel heat exchangers. In this study, we examined the effects of evaporation temperature and Reynolds number of R-134a on the evaporative heat transfer characteristics of R-134a in microchannel heat exchangers with CBAs of $120^{\circ}$, $150^{\circ}$, and $180^{\circ}$ under counterflow conditions. Experimental results show that the evaporative heat transfer rate and evaporative heat transfer coefficient increased with an increase in the Reynolds number of R-134a. Further, the evaporative heat transfer rate corresponding to CBAs of $120^{\circ}$ and $150^{\circ}$ increased to values greater than the evaporative heat transfer rate corresponding to $180^{\circ}$ by approximately 17.1% and 13.3%, respectively, for evaporating temperatures in the range $4.9-14.9^{\circ}C$. The evaporative heat transfer coefficient was affected by the channel angle with increasing evaporative heat transfer coefficient at small channel bending angle.