• Title/Summary/Keyword: evaporation characteristics

Search Result 925, Processing Time 0.023 seconds

Heat Transfer Enhancement Characteristics for Falling-Film Evaporation on Horizontal Enhanced Tubes with Aqueous LiBr Solution (LiBr 수용액을 이용한 수평관 유하액막 증발의 촉진관 전열향상 특성)

  • Kim, Dong Kwan;Kim, Moo Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.9
    • /
    • pp.1267-1276
    • /
    • 1998
  • Falling-film evaporation experiments with aqueous lithium bromide (LiBr) solution were performed to investigate the heat transfer characteristics of enhanced copper tubes. Enhanced tubes (a knurled tube, a spirally grooved tube, and a tube coated with $20{\mu}m$ aluminum particles) and a bare tube were selected as test specimens. Averaged evaporation fluxes of water were obtained from horizontal tubes with various film Reynolds numbers, system pressures, LiBr concentrations and degrees of wall superheat. The enhanced performance of steam generation was compared between tubes with varying parameters. The knurled tube geometry showed the most excellent performance among the tubes tested. The specified enhanced tubes were more useful for generating steam on a low grade heat source such as waste heat.

Effects of Hydrophilic Surface Treatment on Evaporation Heat Transfer at the Outside Wall of Horizontal Tubes (친수성 표면처리가 수평관 외벽의 증발열전달에 미치는 영향)

  • 박노성;황규대;강병하;정진택
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.525-532
    • /
    • 2000
  • Evaporation heat transfer characteristics have been investigated experimentally when distilled water is sprayed on the outside wall of horizontal tubes in a evaporator. This problem is of particular interest in the design of evaporator of an absorption system. Hydrophilic surface treatment was employed to increase the wettability on copper tubes. The results indicate that evaporation heat transfer with hydrophilic tubes is shown to be 25-44% higher than that with bare tubes at evaporation pressure of 31.8 Torr(evaporation temperature$ 30^{\circ}C). Evaporation heat transfer rates of hydrophilic treatment tubes are improved substantially, comparing with those of conventional copper tubes in the wide range of operating parameters, such as water inlet temperatures, water mass flow rates and evaporation pressures.

  • PDF

MgO Properties Depending on E-beam Evaporation Rate and Its Effects on the PDP Discharging Characteristics

  • Kwon, Sang-Jik;Kim, Yong-Jae;Li, Zhao Hui;Kim, Kwang-Ho;Lee, Dal-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.890-893
    • /
    • 2006
  • Effects of the evaporation rate of MgO films using electron beam were investigated on the MgO properties and the discharge characteristics of the plasma display panel (PDP). The evaporation rate was changed from 3 ${\AA}/sec$ to 15 ${\AA}/sec$ at a substrate temperature of $300\;^{\circ}C$. MgO properties such as crystal orientation, surface roughness, contact angle, and film structure were inspected using XPS, AFM, drop shape analysis and SEM. We also studied the relation between MgO properties and PDP discharging characteristics. The minimum firing voltage and maximum efficacy were obtained at evaporation rate of 5 ${\AA}/sec$. In the MgO film deposited at 5 ${\AA}/sec$, (200) orientation was most intensive and surface roughness was minimum.

  • PDF

Microexplosive Vaporization of Miscible Binary Fuel Droplets (미세폭발을 가진 혼화 이성분 연료 액적의 증발 현상)

  • Ghassemi, Hojat;Baek, Seung-Wook;Khan, Qasim Sarwar
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.120-131
    • /
    • 2005
  • The evaporation characteristics of single and multicomponent droplets hanging at the tip of a quartz fiber are studied experimentally at the different environmental conditions under normal gravity. Heptane and Hexadecane are selected as two fuels with different evaporation rates and boiling temperatures. At the first step, the evaporation of single component droplet of both fuels has been examined separately. At the next step the evaporation of several blends of these two fuels, as a binary component droplet, has been studied. The temperature and pressure range is selected between 400 and 700 $^{\circ}C$, and 0.1 and 2.5 MPa, respectively. High temperature environment has been provided by a falling electrical furnace. The initial diameter of droplet was in range of 1.1 and 1.3 mm. The evaporation process was recorded by a high speed CCD camera. The results of binary droplet evaporation show the three staged evaporation. In the the first stage the more volatile component evaporates. The droplet temperature rises after an almost non evaporating period and in the third stage a quasi linear evaporation takes place. The evaporation of the binary droplet at low pressure is accompanied with bubble formation and droplet fragmentation and leads to incomplete microexplosion. The component concentration affects the evaporation behavior of the first two stages. The bubble formation and droplet distortion does not appear at high environment pressure. Nomenclature

  • PDF

Analytical Study of heat Transfer in Evaporative Cooling of a Porous Layer (다공층의 증발냉각 열전달에 관한 해석적 연구)

  • 김홍제;이진호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.104-111
    • /
    • 1992
  • In this study, the heat transfer characteristics of the evaporative transpiration cooled system is analytically investigated considering the occurrence of the two-phase evaporation zone. Under the condition of the external heat input, analytical solutions of the three regions (i.e., vapor, liquid and two-phase evaporation zone) are respectively obtained using the matching conditions for the steady-state problem where properties are constant. As results, the length of the evaporation zone increases with increasing heat input and with decreasing mass flow rate. It also increases with increasing particle size, system porosity, thermal conductivity of material, inlet temperature and latent heat of coolant. The position of the lower interface of the evaporation zone have a lot of efforts on the evaporation zone length, the position of the upper interface penetrates deeper into the porous layer with lower thermal conductivity of porous material, higher system porosity and larger particle size.

An Experimental Study on the Cooling of Unburned Surface due to Water Droplet (물액적에 의한 미연소면의 냉각에 관한 실험적 연구)

  • 방창훈;김정수;예용택
    • Fire Science and Engineering
    • /
    • v.14 no.3
    • /
    • pp.13-18
    • /
    • 2000
  • The objective of the present work is to examine the cooling characteristics of water droplet on the unburned surface. The hot solid surface material used brass, carbon steel and copper at temperature ranging from 70 to $116^{\circ}$. the droplet size is from 2.4 mm to 3.0 mm. The CCD camera was used to record the evaporation histories of the droplets. and the evaporation time of the droplet on the hot solid surface could be determined by using frame-by-frame analysis of the video records. It is found that during the droplet evaporation process for copper the temperature remains nearly constant, whereas for carbon steel the temperature continuously decreases about $1^{\circ}$. During the droplet evaporation process on the hot solid surface, regardless of solid materials, nondimensional droplet volume decreases nondimensional evaporation time increases.

  • PDF

The Analysis of the Discharging Characteristics and MgO protective layer by MgO Evaporation Rates for High-Efficiency PDP (MgO 증착률에 따른 PDP 보호막 물성 및 방전 특성 분석)

  • Kim, Yong-Jae;Kwon, Sang-Jik
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.3
    • /
    • pp.181-186
    • /
    • 2007
  • We have investigated and analyzed the effects of the evaporation rate of MgO films on the MgO properties and the discharge characteristics of a plasma display panel(PDP). The MgO properties such as the crystal orientation, the surface roughness, the film structure, and cathode-luminescence (CL) spectra were inspected using XRD (X-ray diffraction), AFM(atomic force microscopy). And the discharging characteristics of the PDP such as the firing voltage, discharging current, and luminescence were measured using a vacuum chamber with oscilloscope (TDS 540C), current probe (TCP-312A), color meter (CS-100A) and etc. From the experiments results we confirmed the optimum evaporation rate at $5{\AA}/sec$, the MgO properties were shown to be strongly dependent on the evaporation rate, and the MgO properties had an effecton the optical and electrical characteristics. In other words, if the evaporation rates increase than $5{\AA}/sec$, the intensity of (200) orientation and cathode-luminescence (CL) spectra reduce, and the firing vlotage was increased. So the luminuous efficiency grows worse.

A Study on the Combustion Characteristics according to Evaporation rate of Methanol - Blended Fuel (메탄올 혼합 연료의 기화율 변화에 따른 연소특성에 관한 실험적 연구)

  • Cho, H.M.
    • Journal of ILASS-Korea
    • /
    • v.2 no.2
    • /
    • pp.24-34
    • /
    • 1997
  • This paper describes the investigation of combustion characteristics of gasoline-methanol blend in constant volume combustion chamber. A constant volume combustion chamber was used to elucidate a basic combustion characteristics and the premixer was installed to control temperature and equivalence ratio. And the maximum pressure, combustion duration and flame propagation according to the evaporation rate were measured to determine the optimal temperature range for evaporating a blend fuel. These experimental results indicate that the combustion characteristics such as combustion chamber pressure and combustion were deteriorated by decreasing surrounding temperature of fuel. These experimental results indicate that the combustion characteristics such as combustion chamber pressure and combustion were deter orated by decreasing surrounding temperature of fuel injected. It was also found that the overall gasification process for methanol blend fuel was influenced by a combustion chamber temperature rather than a premixer temperature.

  • PDF

Investgation on the Relationships between the Surface Roughness and Film Evaporation (표면거칠기와 액막 증발에 관한 상관 관계 고찰)

  • Kim, Kyun-Seok;Kim, Ig-Saeng;Yoo, Byoung-Hoon;Kim, Do-Hyung;Kim, Chun-Dong;Choi, Ko-Won
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.272-279
    • /
    • 2001
  • The objective of this paper is the investigation of the relationships between the surface roughness and film evaporative characteristics of the surface. For example, when the droplet of liquid is in contact with the solid surface, its behavior strongly depends on the surface characteristics. The material properties and geometry - profile shape, waviness, roughness - of the surfaces have strongly influenced on the wettability of the droplet. To investigate the effect of the surface roughness on the film evaporation, firstly, the characteristics of wettabilities were studied according to contact angle and surface tree energy of specimens with various roughness heights. Secondly, the experimental test were carried out on capacities of the tubes diversly roughened by using different kinds of emery papers. Finally, the relationships between the film evaporation characteristics and surface roughness were explained by means of the correlation of contact angle and surface free energy with surface roughness and the influences of surface tree energy on the heat transfer performance.

  • PDF

Desiccation Characteristics of Dredged Soft Clay by Large Model Test (모형토조시험을 통한 준설매립토의 건조특성에 관한 연구)

  • 정하익;오인규;지성현;이승원;이영남
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.591-596
    • /
    • 2001
  • The purpose of this paper Is to present and discuss some of evaporation and desiccation observed in laboratory experiments under controlled conditions, and is to improve PTM(Progressive Trenching Method) operating technique. PTM is the technically feasible and economically justifiable dewatering and desiccation technique for dredged material containment areas. A series of laboratory experiments with large model test were carried out to get evaporation rate and strength increase. Surface desiccation of dredged material is basically changed by evaporation characteristics which is controlled by weather and trench type, etc. This study shows that trench depth and rain fall are important factors in desiccation of dredged soft clay.

  • PDF