• Title/Summary/Keyword: evaluation of structural performance

Search Result 1,610, Processing Time 0.026 seconds

Evaluation of Shear Bond Strength and Adhesive Bond Durability of Mixed Species Structural Glued Laminated Timber (이수종 구조용집성재의 전단접착력 및 접착내구성 평가)

  • Shim, Sangro;Yeo, Hwanmyeong;Shim, Kugbo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.1 s.129
    • /
    • pp.87-96
    • /
    • 2005
  • This study was carried out to evaluate the shear bond strength and adhesive bond durability of structural glued laminated timber (glulam) manufactured with mixed species lumber of Korean red pine, Korean pine and Japanese larch, using resorcinol adhesive and water-based polymeric-isocyanate adhesive (WPI). Each board used as a glulam lamina was graded by visual inspection. The visual lumber grade of the all species was very low due to the large size and number of knots and the steep slope of grain. In view of the results, appropriate pruning, sawing and drying processes might be needed to produce high grade lamina lumber with small knot size and drying defect free. Shear bond strength of every tested glulam specimen ranged between 7.9 and $9.9N/mm^2$, and much higher than the Korean Standard (KS) for glulam shear bond strength, $7.1N/mm^2$. There was not much shear bond strength difference between wood/resorcinol and wood/WPI. The resorcinol adhesive bond durability exceeded KS requirements. However, delamination on the end-grain surfaces of WPI glulam submerged in both room temperature and boiling water severely occurred, and its durability did not meet KS requirements. Further investigations may be required, and special care should be taken, to ensure long service life of WPI glulam used for exterior application. Results of this study are expected to be useful for improvement of mechanical properties and structural performance of mixed species glulam.

Post Occupancy Evaluation of the Forest Experience Centers for Children (유아숲체험장의 이용후 평가)

  • Kang, Tae-Sun;Lee, Myung-Woo;Jeong, Moon-Sun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.2
    • /
    • pp.109-123
    • /
    • 2017
  • Due to the positive effect of forest space for child development, the creation and operation of forest activity space of various organizations is increasing in quantity; however, the research on practical space design and management program is insufficient. Therefore, the purpose of this study is to evaluate the space and management programs of the forest experience centers through the post-occupancy evaluation of teachers and preschoolers participating in forest activities. To do this, we analyzed the selected twelve sites through field survey, class observation, and interviews with forest education specialists, and then surveyed 115 forest education experts and childcare teachers for importance, performance, overall satisfaction, and space preference. In addition, we accessed overall satisfaction and space preference of twenty-nine preschoolers through interviews, photo-simulation, and questionnaires. As a result, the importance and performance of management program area was rated higher than the spatial characteristics area. In terms of group comparison, the group with active structured program rated two areas higher than the groups with free play. Preschoolers with structured programs preferred facility space, but preschoolers with free play preferred nature. Two preschooler groups rated forest activity as satisfactory. Based on the analysis results: 1) The composition of the forest activity space should ensure accessibility, safety, diversity of diversity, water space, connect to the forest road, and secure various terrains, trees, and natural materials; 2) The management program should ensure that forest activity programs have the proportional balance of structural programs and free play; also. management programs should plan for sufficient free playtime and a high share of play in the forest; and 3) Ensure the role and expertise of forestry specialists and run a program to increase the autonomy of preschoolers.

Verification of Validity on Awareness Tool of Business Continuity for Railway Organizations (철도기관을 대상으로 한 사업연속성 인식도구의 타당성 검증)

  • Jeong-ho Chang;Chong-soo Cheung
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.195-203
    • /
    • 2023
  • Purpose: This study intends to check validity of tools for awareness of Business Continuity through measurement and analysis on the sub factors of Business Continuity by employees of railway-related organizations. Method: Based on the preceding study, sub factors of the awareness of Business Continuity are divided into 7 and the total of 29 questions were delivered to employees of railway-related organizations for investigation and analysis through the online survey tool. Result: According to EFA result, the number of factors of awareness of Business Continuity based on the theoretical ground was reduced to 7 and the total coefficient of determination was 82.616%. Checking the questions by factor, all the questions were loaded as intended. Conclusion: Validity of measurement tools of Business Continuity whose sub factors are the Context of Organization, Leadership, Planning, Operation, Support, Performance evaluation, and Improvement for railway organizations were secured through the Exploratory Factor Analysis of this study. As for the further tasks, studies on the structural relationship among internalization of business continuity, organization effectiveness, learning support environment, etc are required.

The use of SMA wire dampers to enhance the seismic performance of two historical Islamic minarets

  • El-Attar, Adel;Saleh, Ahmed;El-Habbal, Islam;Zaghw, Abdel Hamid;Osman, Ashraf
    • Smart Structures and Systems
    • /
    • v.4 no.2
    • /
    • pp.221-232
    • /
    • 2008
  • This paper represents the final results of a research program sponsored by the European Commission through project WIND-CHIME ($\underline{W}$ide Range Non-$\underline{IN}$trusive $\underline{D}$evices toward $\underline{C}$onservation of $\underline{HI}$storical Monuments in the $\underline{ME}$diterranean Area), in which the possibility of using advanced seismic protection technologies to preserve historical monuments in the Mediterranean area is investigated. In the current research, the dynamic characteristics of two outstanding Mamluk-Style minarets, which similar minarets were reported to experience extensive damage during Dahshur 1992 earthquake, are investigated. The first minaret is the Qusun minaret (1337 A.D, 736 Hijri Date (H.D)) located in El-Suyuti cemetery on the southern side of the Salah El-Din citadel. The minaret is currently separated from the surrounding building and is directly resting on the ground (no vaults underneath). The total height of the minaret is 40.28 meters with a base rectangular shaft of about 5.42 ${\times}$ 5.20 m. The second minaret is the southern minaret of Al-Sultaniya (1340 A.D, 739 H.D). It is located about 30.0 meters from Qusun minaret, and it is now standing alone but it seems that it used to be attached to a huge unidentified structure. The style of the minaret and its size attribute it to the first half of the fourteenth century. The minaret total height is 36.69 meters and has a 4.48 ${\times}$ 4.48 m rectangular base. Field investigations were conducted to obtain: (a) geometrical description of the minarets, (b) material properties of the minarets' stones, and (c) soil conditions at the minarets' location. Ambient vibration tests were performed to determine the modal parameters of the minarets such as natural frequencies and mode shapes. A $1/16^{th}$ scale model of Qusun minaret was constructed at Cairo University Concrete Research Laboratory and tested under free vibration with and without SMA wire dampers. The contribution of SMA wire dampers to the structural damping coefficient was evaluated under different vertical loads and vibration amplitudes. Experimental results were used along with the field investigation data to develop a realistic 3-D finite element model that can be used for seismic risk evaluation of the minarets. Examining the updated finite element models under different seismic excitations indicated the vulnerability of such structures to earthquakes with medium to high a/v ratio. The use of SMA wire dampers was found feasible for reducing the seismic risk for this type of structures.

Predicting fetal toxicity of drugs through attention algorithm (Attention 알고리즘 기반 약물의 태아 독성 예측 연구)

  • Jeong, Myeong-hyeon;Yoo, Sun-yong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.273-275
    • /
    • 2022
  • The use of drugs by pregnant women poses a potential risk to the fetus. Therefore, it is essential to classify drugs that pregnant women should prohibit. However, the fetal toxicity of most drugs has not been identified. This takes a lot of time and cost. In silico approaches, such as virtual screening, can identify compounds that may present a high risk to the fetus for a wide range of compounds at the low cost and time. We collected class information of each drug from the hazard classification lists for prescribing drugs in pregnancy by the government of Korea and Australia. Using the structural and chemical features of each drug, various machine learning models were constructed to predict fetal toxicity of drugs. For all models, the quantitative performance evaluation was performed. Based on the attention algorithm, important molecular substructures of compounds were identified in the process of predicting the fetal toxicity of the drug by the proposed model. From the results, we confirmed that drugs with a high risk of fetal toxicity can be predicted for a wide range of compounds by machine learning. This study can be used as a pre-screening tool for fetal toxicity predictions, as it provides key molecular substructures associated with the fetal toxicity of compounds.

  • PDF

Structural Performance Evaluation of Steel Fiber-Reinforced Concrete Beams with Recycled Coarse Aggregates (순환골재를 사용한 강섬유보강 콘크리트보의 구조 성능 평가)

  • Shin, Jae-Lin;Kim, Woo-Suk;Baek, Seung-Min;Kang, Thomas H.-K.;Kwak, Yoon-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.3
    • /
    • pp.215-227
    • /
    • 2015
  • In this study, twenty four steel-fiber reinforced concrete (SFRC) beams using recycled coarse aggregates (RCA) were manufactured to examine the shear behavior of SFRC and to determine the beams' ultimate shear strengths. The RCA replacement ratio was fixed at 30%. The variables studied in this investigation are: (1) shear span-to-depth ratios (a/d) of 2, 3 and 4; (2) longitudinal reinforcement ratio (${\rho}$) of 0.008 and 0.0127; and (3) steel fiber volume fractions ($V_f$) of 0, 0.5, 0.75 and 1%. Test results were analyzed and then compared with the findings and proposals of various other researchers. Based on the test results, the more steel fiber volume fraction is increased, the large crack resistance and shear strength are exhibited. Most of the experimental data is higher than the theoretical value. Therefore, steel-fiber reinforced concrete beams using recycled coarse aggregates are suggested to be applied for building structures.

Performance Evaluation of perpetual Asphalt Pavements Using an Accelerated Pavement Tester (포장가속시험기를 이용한 장수명 아스팔프포장의 공용성 평가 연구)

  • Song, Seo-Gyu;Lee, Jung-Hun;Lee, Hyun-Jong;Hwang, Eui-Yoon
    • International Journal of Highway Engineering
    • /
    • v.7 no.3 s.25
    • /
    • pp.1-10
    • /
    • 2005
  • In this study, accelerated pavement tester(APT) was performed on long-life asphalt pavements that can save maintenance and user costs by increasing the design life twice longer than conventional asphalt pavements. Basic material testings are first conducted on a high modulus base(HMB) mixture developed in this study. Four different pavement sections including thin and thick conventional and thin and thick HMB courses are constructed to compare the load-carrying capacities and to investigate the fatigue and rutting performances using an accelerated pavement tester. Tensile strain values at the bottom of base courses under the various loading levels are measured. The tensile strain values of the HMB sections are lower than those of the conventional sections. It is observed from the APT performed on the thin pavement sections that no significant cracks are developed up to the 180,000 cycles of a wheel load. In terms of rutting, only 3mm of rutting is developed in the thick HMB section while 5.3mm of rutting is developed in the thick conventional section at the 90,000 cycles of the wheel load. The HMB material developed in this study can be successfully used in the long-life asphalt pavements because of its excellent fatigue and rutting performances. It is estimated from a series of structural analysis that the use of the HMB material instead of the conventional base materials may reduce the asphalt thickness at least 5cm because of its better load-carrying capacity.

  • PDF

Dynamic Analysis of External Fuel Tank and Pylon Using Stick Model (스틱모델을 이용한 외부연료탱크 및 파일런 동특성 해석)

  • Kim, Hyun-gi;Kim, Sung Chan;Park, Sung Hwan;Choi, Hyun-Kyung;Hong, Seung Ho;Ha, Byung Kun
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.1
    • /
    • pp.21-27
    • /
    • 2020
  • Aircraft should be equipped with various external stores for mission performance. Since these external stores may cause structural instability of aircraft, an evaluation of the effects between the aircraft and the external stores is required. For this purpose, an aircraft dynamic characteristics analysis reflecting an external store was performed, and the finite element model for the analysis of aircraft dynamic characteristics should simulate the dynamic characteristics of the component as accurately as possible while using a minimum of the nodes and elements. In this study, a stick model was constructed for dynamic characteristics analysis of the external fuel tank and installation pylon using MSC Patran/Nastran. For the calculation of the equivalent stiffness of the stick model, a simple beam theory was applied to construct the stick model of each part, and the validity of each stick models was confirmed by mode comparison with the fine model. Additionally, the model analysis of the stick model assembly, simulating a pylon equipped with an external fuel tank was performed to confirm that the basic modes required for the analysis of aircraft dynamic characteristics are well extracted. Finally, it was confirmed that the developed stick model assembly could be used for analysis of aircraft dynamic characteristics by comparing the errors in modes between the fine model assembly and the stick model assembly.

Evaluation of Structural Performance in CFT Truss Girder with the Arch-Shaped Lower Chord (아치형상의 하현재를 갖는 CFT 트러스 거더의 구조성능 평가)

  • Chung, Chul-Hun;Song, Na-Young;Ma, Hyang-Wook;Oh, Hyun-Chul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.315-327
    • /
    • 2009
  • In this study, the static test of CFT truss girders for different f/L ratios was conducted to determine how the ultimate strength of the CFT truss girder was affected by different f/L ratios. A total of two CFT truss girders were constructed and tested under bending condition. The length of all specimens is 20,000 mm. The CFT truss girder is a tubular truss composed of chord members made of concrete-filled circular tubes. The main parameter analyzed in the experimental study was the f/L ratio. This factor was experimentally investigated to assess their influence on ultimate strength and stiffness. The test results show that CFT truss girder has good elastic-plastic property and ductility. The presence of the f/L ratios in CFT truss girders alters its ultimate strength because of the global stiffness of the CFT truss girders. The ultimate strength of CFT truss girders increases as the f/L ratio increases. If the f/L ratio of the CFT truss girders increases twofold, the ultimate strengths increase by 80%. The CFT truss girders showed that they retained large deformation capacity, even after reaching the ultimate strength. Results of this investigation demonstrated the potential for efficiently using a CFT truss as a bridge girder.

A Study on Structural Performance Evaluation of RC Beams Strengthened with CFRP Plate (탄소섬유판으로 보강된 철근콘크리트 보의 보강성능에 관한 연구)

  • Kim Joong-Koo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.6 s.22
    • /
    • pp.212-217
    • /
    • 2004
  • Carbon fiber reinforced plastic(CFRP) plate Is one of the alterative materials for soengthening of reinforced and prestressed connote members due to excellent strength and light weight In this paper, the behavior of beams strengthened with CFRP plate and CFS(Carbon fiber sheet) is observed and analyzed from the test results. Especially specimens with thick plate is tested when large moment and large shear lone appear in same position. The main failure mode is a peeling-off of the CFRP plate near the loading points due to flexural-shear crack, Because of this failure mode, failure load is not linearly proportional to the thickness of CFRP plates. When beam is wrapped with CFS around oかy loading point it does not influence on the failure loads. Depending on the loading pattern, it is necessary to consider different design criteria for reinforced concrete members with external reinforcement. When line moment and large shear force appear in same location, maximum thickness may limit to 0.6mm and ratio between moment of strengthened beam and moment of unstrengthened beam is proposed 1.5-2.0. In order to use the plate of thicker than 6mm, CFS may be extended to the location which moment of strengthened beam is 1.5 times than moment of unstrengthened beam.