• Title/Summary/Keyword: evaluation analysis

Search Result 25,729, Processing Time 0.065 seconds

Effect of Proteinase Activity on the Cheddar Cheese Quality (단백분해 효소 활성(蛋白分解 酵素 活性)이 Cheddar Cheese의 품질(品質)에 미치는 영향(影響))

  • Kim, Min-Bae
    • Journal of Dairy Science and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.157-164
    • /
    • 1996
  • This study aimed increase the quality during ripening of Cheddar cheese made with proteinase-negative mutant of Streptococcus lactis KCTC 1913 selected by curing. The degradation of protein during cheese ripening were investigated by electrophoresis and chromatography. The results were summarized as follow ; 1. The number of lactic acid bacteria decreased with the ripening stage, and that of the control cheese decreased faster than that of the cheese made with mutant. 2. Polyacrylamide gel electrophoretic analysis of cheese caseins revealed no difference between the cheese made with mutant and the control cheese, but differences along with the ripening stage were evident. 3. On Sephadex G-25 column chromatography, the extracts of bitter components from the green cheese and 3 month ripended cheese were fractionated into 3 fractions. With the progress of ripening, bitter peptides were degraded to rather small peptides or free amino acids. 4. Sensory evaluation of the 3 month ripended Cheddar cheese found no significant differences in color but the cheese made with mutant evidenced higher palatability in flavor and better texture than the control cheese. 5. The yields of the cheddar cheese made with mutant was 0.14% higher than that of the control cheese.

  • PDF

Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air (실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가)

  • Baek, Sung-Ok;Moon, Young-Hun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.496-513
    • /
    • 2004
  • This study was carried out to evaluate the performance of sampling and analytical methodology used for the measurement of toxic volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis. Target analytes were 33 compounds including major aromatic compounds such as BTEX, and halogenated compounds. The methodology was investigated with a wide range of different adsorbents which are commercially available and have been frequently adopted for the VOC measurement. A total of 10 adsorbents were tested in this study: 6 carbon-based adsorbents such as Carbotrap, Carbopack B, Carbosieve S-III, Carboxen 1000, Carbotrap C, Activated Charcoal; and 4 polymer-based adsorbents including Tenax, Porapak Q, Chromosorb 102, and Chromosorb 106. The sampling performance was evaluated with respect to the sampling capacity of VOCs with single-adsorbent and multiple-adsorbents methods for standard samples and field samples. As a result, the best adsorbents for single-adsorbent method in the sampling of toxic organic compounds (including benzene, toluene, xylenes etc.) appeared to be Carbotrap, Carbopack B and Tenax TA. On the other hand, Chromosorb 102, Chromosorb 106 and Porapak Q were found to be unsuitable adsorbents for VOC measurement based on thermal desorption method. Multi-adsorbent packings were evaluated with 4 carbon-based adsorbents, which classified by 3 combination sets of double adsorbents and 2 combination sets of triple adsorbents. The results indicated that the most suitable combination for toixc VOC measurements is Carbotrap C with Carbotrap. Multi-sorbents tubes packed with a strong adsorbent such as Carbosieve S-III or Carboxen 1000 were found to be relatively unsuitable for several compounds, not only owing to the effect of migration of adsorbed compounds from weaker adsorbent to stronger adsorbent, but to hydrophobic nature of the adsorbents. Therefore, it should be addressed that selection of a proper adsorbent (or combination of multi sorbents) is extremely important to obtain reliable data for the concentrations of toxic VOCs in indoor and outdoor environments.

Quality Characteristics of Fermented Pork with Korean Traditional Seasonings (한국 전통 양념을 이용한 발효 돼지고기의 품질 특성)

  • Jin, S.K.;Kim, C.W.;Lee, S.W.;Song, Y.M.;Kim, I.S.;Park, S.K.;Hah, K.H.;Bae, D.S.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.2
    • /
    • pp.217-226
    • /
    • 2004
  • This study was canied out to evaluate the quality characteristics of the fermented pork with Korean traditional seasonings. The samples, outside muscle of pork ham were cut to cube(7 ${\times}$ 12 ${\times}$ 2cm) and five Korean traditional seasonings such as garlic paste(TI), pickled Kimchi(T2), pickled Kimchi juice(T3), soybean paste(T4), red pepper paste(T5) were seasoned by the proportions of meat to seasonings(1 : 1). The seasoned samples were fennented at - 1 ${\pm}$ 1$^{\circ}C$ for 20 days. According to proximate composition analysis, all pork samples contained protein 20 ${\sim}$ 22%, fat 3 ${\sim}$ 5%, moisture 64 ${\sim}$ 70% and ash 1.8 ${\sim}$ 2.0%. However, T5 had high crude fat level and relatively low moisture content. The highest pH among treatments was shown in TI whereas T3 showed the lowest. Water holding capacity(WHC) of T4 and T5 were higher, while those values were lower in T3 compared with other treatment. Shear force value was the highest in T5, while it was the lowest in T4. TBARS value of T3 was the highest, while that was the lowest in T4. Moreover the highest VBN value was observed in T4 due to fermentation of soy protein. However, the lowest VBN value shown in Tl indicated the inhibition of protein degradation by the garlic. The highest saccarinity was shown in T5 but it was the lowest of in T3. Salinity was shown to be high in T2 and low in T5. $L^*$ values of T4 was higher both at the surface and inner side of samples than the others but T5 showed the lowest value. T2 showed the highest $a^*$ value but T4 and T5 showed the lowest. In the result of sensory evaluation for cooked meat, T5 had the highest score in all item including overall acceptability, while T4 had the lowest score. Unsaturated fatty acid(UFA) ratio of T5 and n were 72.16 and 69.93 respectively, and the ratio of UFA/Saturated fatty acid(SFA) were higher in the order of T5 >T4> T3 >Tl >T2. Overall quality characteristics were higher in the order of T5 >T2 >Tl >T4 >T3.

Physiological Responses of Green Roof Plants to Drought Stress (건조스트레스에 따른 옥상녹화 식물의 생리적 반응)

  • Park, Seong-Sik;Choi, Jaehyuck;Park, Bong-Ju
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.2
    • /
    • pp.51-59
    • /
    • 2017
  • This study evaluated the drought tolerance of Liriope platyphylla F.T.Wang & T.Tang, Dendranthema zawadskii var. lucidum (Nakai) J.H.Park, Hosta longipes (Franch. & Sav.) Matsum., Sedum sarmentosum Bunge and Zoysia japonica Steud. for an extensive green roof. In order to assess drought tolerance of green roof plants, several criteria were measured such as volumetric water content, leaf and soil moisture potential, chlorophyll a and b, chlorophyll fluorescence, photosynthesis, stomatal conductance, transpiration rate and antioxidants. The results of the drought tolerance measurement of green roof plants focused on the gradually withering of plants from lack of volumetric water content. D. zawadskii was the first to show an initial wilting point, followed by Z. japonica, H. longipes and L. platyphylla in order while S. sarmentosum showed no withering. It was concluded that H. longipes, L. platyphylla and S. sarmentosum were highly drought tolerant plants able to survive over three weeks. Furthermore, chlorophyll a and b were divided into two types: Type I, which kept regular content from the beginning to the middle of the period and suddenly declined, like H. longipes and Z. japonica; and Type II, which showed low content at the beginning, sharply increased at the middle stage and decreased, like D. zawadskii, L. platyphylla and S. sarmentosum. Volumetric water content and the amount of evapotranspiration consistently declined in all plant species. The analysis of chlorophyll fluorescence results that S. sarmentosum, which had relatively high drought tolerance, was the last to decline, while Z. japonica and S. sarmentosum withered after rapid reduction. At first, photosynthesis, stomatal conductance and transpiration rate showed high activity, but they lowered as the plant body closed stomata owing to the decrease in volumetric water content. Measuring antioxidants showed that when drought stress increased, the amount of antioxidants grew as well. However, when high moisture stress was maintained, this compound was continuously consumed. Therefore, the variation of antioxidants was considered possible for use as one of the indicators of drought tolerance evaluation.

The Performance Bottleneck of Subsequence Matching in Time-Series Databases: Observation, Solution, and Performance Evaluation (시계열 데이타베이스에서 서브시퀀스 매칭의 성능 병목 : 관찰, 해결 방안, 성능 평가)

  • 김상욱
    • Journal of KIISE:Databases
    • /
    • v.30 no.4
    • /
    • pp.381-396
    • /
    • 2003
  • Subsequence matching is an operation that finds subsequences whose changing patterns are similar to a given query sequence from time-series databases. This paper points out the performance bottleneck in subsequence matching, and then proposes an effective method that improves the performance of entire subsequence matching significantly by resolving the performance bottleneck. First, we analyze the disk access and CPU processing times required during the index searching and post processing steps through preliminary experiments. Based on their results, we show that the post processing step is the main performance bottleneck in subsequence matching, and them claim that its optimization is a crucial issue overlooked in previous approaches. In order to resolve the performance bottleneck, we propose a simple but quite effective method that processes the post processing step in the optimal way. By rearranging the order of candidate subsequences to be compared with a query sequence, our method completely eliminates the redundancy of disk accesses and CPU processing occurred in the post processing step. We formally prove that our method is optimal and also does not incur any false dismissal. We show the effectiveness of our method by extensive experiments. The results show that our method achieves significant speed-up in the post processing step 3.91 to 9.42 times when using a data set of real-world stock sequences and 4.97 to 5.61 times when using data sets of a large volume of synthetic sequences. Also, the results show that our method reduces the weight of the post processing step in entire subsequence matching from about 90% to less than 70%. This implies that our method successfully resolves th performance bottleneck in subsequence matching. As a result, our method provides excellent performance in entire subsequence matching. The experimental results reveal that it is 3.05 to 5.60 times faster when using a data set of real-world stock sequences and 3.68 to 4.21 times faster when using data sets of a large volume of synthetic sequences compared with the previous one.

Difference in the Quality of Life and Related Factors according to the Employment Status (경제활동 상태에 따른 삶의 질 차이와 관련요인)

  • Gim, Mi-Seon;Han, Ji-Yeon;Kim, Chul-Woung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6080-6088
    • /
    • 2015
  • The purpose of study is to find difference in the quality of life and related factors according to the employment status. Using data from the fifth National Health and Nutrition Survey, economically active population of 20-69 years old 3,429 participants who said to questions of 'economic activity status' were finally used as analysis subjects in Korea. According to economic activity status, individuals were divided by the six different employment status and their quality of life was inspected using the EQ-5D dimensions and index score as well as analyzing the factors affecting the quality of life. As a result, unemployed compared to full-time workers, had significantly higher needs of four dimensions and Unpaid family workers had in the dimensions of Mobility, Self-care and Usual activities and temporary job had in the dimensions of Self-care and Usual activities. After figuring out life quality factors according to employment status, it was found that compared to full-time workers greater age(${\beta}=-0.089$, p<0.001), more stress(${\beta}=-0.143$, p<0.0001), hyperlipidemia(${\beta}=-0.064$, p<0.0001), stroke, arthritis(${\beta}=-0.160$, p<0.0001), respiratory diseases(${\beta}=-0.055$, p<0.001) and chronic health conditions were more influential to low quality of life for temporary job(${\beta}=-0.034$, p<0.05), day workers(${\beta}=-0.078$, p<0.0001) and unemplyed(${\beta}=-0.052$, p<0.01). The study is reported that it is to find difference in the quality of life and related factors according to the employment status and it is considered to provide basis for health evaluation of utilization in the same field of study.

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Significance of Bone Scan in Chest Trauma (흉부외상에서 골스캔의 의의)

  • Kim, Soo-Sung;Kim, Soon
    • Journal of Chest Surgery
    • /
    • v.35 no.6
    • /
    • pp.454-459
    • /
    • 2002
  • Clinical analysis of the relation between the clinical data of chest trauma patients and bone scan results was done to investigate the sensitivity and specificity of bone scan for the diagnosis of rib or chondral fracture. Material and Method: 445 patients treated due to chest trauma in Dongguk University Kyungju Hospital from July 1998 to December 2001 were studied. Age and sex distribution, causes of chest trauma, interval from the injury to arrival at hospital, final diagnosis, relationship between the chest pain and bone scan results, relationship between local tenderness and bone scan results, and sensitivity and specificity of bone scan were studied. Result: The male was 61.6% and the female was 38.4%. Age distribution was nearly even from the twenties to the sixties. The traffic accident was the most common cause of chest injury(60.4%). Most patients(76.6%) were arrived to the hospital within 6 hours after chest trauma. Rib fracture was the most common final diagnosis(46.5 %). The relationship between the duration of chest pain and tenderness and the bone scan results were significant, and the same in the relationship between the duration of local tenderness and the bone scan results, but the latter is more significant. The sensitivity of bone scan was 99.4% and the specificity was 90.4%. Conclusion: If the patient complains the chest pain continuously and the local tenderness around the chest is continued over 3 weeks, it is good to perform the bone scan. Further study including the MRI may be helpful for more evaluation in chest trauma patients.

In Vitro Effect of 808-nm Diode Laser on Proliferation and Glycosaminoglycan Synthesis of Rabbit Articular Chondrocytes (토끼 관절 연골세포의 증식과 글리코스아미노글리칸 합성에 대한 808-nm 다이오드 레이저의 효능 평가)

  • Minar, Maruf;Hwang, Ya-won;Choi, Seok-hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • The aim of the study was to assess the in vitro effect of 808-nm InGaAs diode laser on rabbit articular chondrocyte proliferation and sulphated glycosaminoglycan (sGAG) synthesis in alginate bead. Previous studies revealed either positive or negative stimulatory effects of laser on different types of cells. A 808-nm InGaAs diode laser at 1.0W power output was used to irradiate the rabbit chondrocytes in alginate beads with energy densities of $31J/cm^2$ (G 1) and $62J/cm^2$ (G 2) corresponding to the experimental groups for 10 seconds and 20 seconds, respectively at 24, 48, 72 and 96 hours after seeding. Control group was left untreated. MTT assay was performed at 1 week and 2 weeks after the $1^{st}$ laser irradiation in alginate beads. sGAG synthesis in alginate beads at 1 week and 2 weeks were determined by DMMB assay. Histological evaluation for cellular distribution and sGAG deposition around the cells were performed by alcian blue stain. MTT assay revealed no positive stimulatory effect in cell proliferation in alginate bead. DMMB assay results showed significantly increased sGAG production in G 2 chondrocytes at 2 weeks. Image analysis of alcian blue stained slides also showed significantly higher percentage of positive alcian blue stain in G 2 chondrocytes. This result suggests that 808-nm InGaAs diode laser with 1.0 W power output although cannot stimulate cell proliferation it can increase the cell secretion activity and sGAG deposition in alginate beads.

Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs (심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향)

  • Shin, Chang-ho;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.486-490
    • /
    • 2015
  • Two-demensional echocardiography is routinely used for evaluation of cardiac function. Visualization of the endocardial border is essential for the assessment of global and regional left ventricular with cardiac disease. SonoVue$^{TM}$ is a microbubble contrast agent that consists of sulfur hexafluoride-filled microbubbles in a phospholipid shell. There were many studies about contrast echocardiographic examination using SonoVue$^{TM}$ contrast agent, and various doses of SonoVue$^{TM}$ were used. To our knowledge, in published veterinary medicine, there was not reported for diagnostic efficient dose of SonoVue$^{TM}$ to evaluate contrast enhanced left ventricular endocardial border delineation (LVEBD). The purpose of this study is to compare the visualization time of LVEBD and find efficient dose of SonoVue$^{TM}$ for using various doses in dogs. Ten healthy Beagles were recruited to the study. Three different doses (0.03 ml/kg, 0.05 ml/kg and 0.1 ml/kg) of SonoVue$^{TM}$ were injected. Endocardial segments were assigned based on previously established methodology, where by the four-chamber views of the LV were divided into 6 segments. In this study, Contrast enhancement of the LVEBD after each injection was evaluated visually at the time point of overall contrast enhancement (Segmental scoring 5+) in the LV by three investigators in a blind manner. Statistical analysis was performed with SPSS version 14.0. All data were analyzed using one-way ANOVA, the multiple comparison Scheffe test. When data for the three offsite readers were combined, mean durations of useful contrast were $3.54({\pm}2.14)$, $6.15({\pm}2.61)$, and $24.39({\pm}11.10)$ seconds for the 0.03 ml/kg, 0.05 ml/kg, and 0.1 ml/kg SonoVue$^{TM}$ doses, respectively. After injection of contrast agent, there were no significant change in side effects such as urticaria, angioedema, hypersensitivity reactions, and digestive system disorders. This study suggests that efficient dose of SonoVue$^{TM}$ contrast agent for improvement of the left ventricle visualization is 0.1 ml/kg. The duration of useful enhancement of LVEBD and the reproducibility were also the highest at the 0.1 ml/kg dosage.