• 제목/요약/키워드: esthetic restorative materials

검색결과 93건 처리시간 0.02초

복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고- (A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

IPS-Empress 도재에 대한 콤포짓트 레진의 전단결합강도 (EFFECTS OF SURFACE TREATMENT AND BONDING AGENTS ON SHEAR BOND STRENGTH OF THE COMPOSITE RESION TO IPS-EMPRESS CERAMIC)

  • 윤병식;임미경;이용근
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.413-423
    • /
    • 1998
  • Dental ceramics exhibit excellent esthetic property, compressive strength, chemical durability, biocompatibility and translucency. This study evaluated the shear bond strength of composite resin to the new heat-pressed ceramic material (IPS-Empress System) depending on the surface treatments and bonding agents. The surface treatments were etching with 4.0% hydrofluoric acid, application of silane, and the combination of the two methods. Composite resin was bonded to ceramic with four kinds of dentin bonding agents(All-Bond 2, Heliobond, Scotch bond Multi-purpose and Tenure bonding agents). The ceramic specimen bonded with composite resin was mounted in the testing jig, and the universal testing machine(Zwick 020, Germany) was used to measure the shear bond strength with the cross head speed of 0.5 mm/min. The results obtained were as follows 1. The mean shear bond strength of the specimens of which the ceramic surface was treated with the combination of hydrofluoric acid and silane before bonding composite resin was significantly higher than those of the other surface treatment groups(p<0.05). 2. In the case of All-Bond 2 and Scotchbond Multi-purpose bonding agent group, the surface treatment methods did not influenced significantly on the shear bond(p>0.05). 3. Of the four bonding agents tested, the shear bond strength of Heliobond was significantly lower than those of other bonding agents regardless of the surface treatment methods(p<0.05). 4. The highest shear bond strength($12.55{\pm}1.92$ MPa) was obtained with Scotchbond Multipurpose preceded by the ceramic surface treatment with the combination of 4% hydrofluoric acid and silane.

  • PDF

Color assessment of resin composite by using cellphone images compared with a spectrophotometer

  • Rafaella Mariana Fontes de Braganca;Rafael Ratto Moraes ;Andre Luis Faria-e-Silva
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.23.1-23.11
    • /
    • 2021
  • Objectives: This study assessed the reliability of digital color measurements using images of resin composite specimens captured with a cellphone. Materials and Methods: The reference color of cylindrical specimens built-up with the use of resin composite (shades A1, A2, A3, and A4) was measured with a portable spectrophotometer (CIELab). Images of the specimens were obtained individually or pairwise (compared shades in the same photograph) under standardized parameters. The color of the specimens was measured in the images using RGB system and converted to CIELab system using image processing software. Whiteness index (WID) and color differences (ΔE00) were calculated for each color measurement method. For the cellphone, the ΔE00 was calculated between the pairs of shades in separate images and in the same image. Data were analyzed using 2-way repeated-measures analysis of variance (α = 0.05). Linear regression models were used to predict the reference ΔE00 values of those calculated using color measured in the images. Results: Images captured with the cellphone resulted in different WID values from the spectrophotometer only for shades A3 and A4. No difference to the reference ΔE00 was observed when individual images were used. In general, a similar ranking of ΔE00 among resin composite shades was observed for all methods. Stronger correlation coefficients with the reference ΔE00 were observed using individual than pairwise images. Conclusions: This study showed that the use of cellphone images to measure the color difference seems to be a feasible alternative providing outcomes similar to those obtained with the spectrophotometer.

분광색채계측기를 이용한 Vita Shade 광중합형 복합레진의 색상 비교 (COMPARATIVE EVALUATION OF LIGHT-CURED COMPOSITE RESINS BASED ON VITA SHADE BY SPECTROCOLORIMETER)

  • 조경이;황인남;최홍란;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.424-432
    • /
    • 1998
  • To get a satisfactory result in the composite resin restorations, it is necessary to choose correct shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guide or Bioform shade guide, but color differences might be expected even using the same shade in various materials. In this study, five kinds of light-cured composite resins with A2 and B3 shade were used to measure and compare the color each other while one porcelain served as a control. All composite resins (Spectrum TPH (SP), VeridonFil- Photo (VE), Z100 (Z100), Charisma (CH), Prodigy (PRO)) were filled in to the metal mold (12 mm diameter, 2 mm depth), followed by compression, polymerization and polishing with wet sandpaper. The specimens of porcelain were fabricated by using the refractory mold for porcelain. After 24 hours, the specimens were placed on the spectrocolorimeter and spectral reflectance were measured under CIE illuminant D65. After measuring the values of $L^*$, $a^*$, $b^*$ and ${\Delta}E^*$, following results were obtained; 1. The $L^*$, $a^*$ and $b^*$ values of both shade of porcelain specimens showed significantly higher than those of resin specimens(p<0.05). 2. In comparing the resin specimens of the A2 shade, differences were significant except $L^*$ values of SP-CH and PRO-VE, $a^*$ values of the VE-SP and $b^*$ values of the VE-Z100 and SP-PRO(p<0.05), 3. In comparing the resin specimens of the B3 shade, differences were significant except $L^*$ values of PRO-SP, $a^*$ values of the SP-PRO and Z100-VE and b* values of the PRO-SP(p<0.05). 4. In comparing the resin specimens of the A2 shade, color differences between materials (${\Delta}E^*$) showed the lowest value of 1.66, and the highest was 5.16. ${\Delta}E^*$ values of the materials of VE-PRO, CH-PRO, SP-PRO, SP-Z100 and SP-CH were lower than 3.3. 5. In comparing the resin specimens of the B3 shade, the lowest value of the ${\Delta}E^*$ was 0.57 and the highest was 5.92. ${\Delta}E^*$ values of Z100-CH and SP-PRO were lower than 3.3. The present study revealed there was perceptible color difference between materials even if they have the same designated shade based on Vita shade guide. The results of the present study suggested that it would be necessary to establish the reproducible and constant color specification system for an esthetic restoration.

  • PDF

임시 고정성 보철물 제작용 레진의 굽힘강도 (Flexual strength of resins for provisional fixed prostheses)

  • 최명아;안승근;조국현
    • 구강회복응용과학지
    • /
    • 제16권3호
    • /
    • pp.221-227
    • /
    • 2000
  • Provisional fixed partial dentures(FPDs) are an important part of many prosthodontic treatment procedures. These provisional fixed prostheses must fulfill biologic, mechanical, and esthetic requirements to be considered successful. Consideration of all these factors and requirements are important because provisional resin restorations may be worn over a long period to assess the results of periodontal and endodontics therapies, and also during the restorative phase of implant reconstructive procedures. This in vitro study examined flexual strength of four resins commonly used for fixed provisional prostheses. The effects of polymerization conditions were also evaluated. The four resins tested were : Caulk Temporary bridge resin(L.D. Caulk Co. Dentsply International Millford), Jet(Lang Dental Mfg. Co. Chicago. ILL. U.S.A), Alike (Coe Laboratories. Inc. Chicago. ILL. U.S.A) and Tokuso Curefast (Coe Laboratories. Inc. Chicago. ILL. U.S.A) The test specimens were 65mm long, 14mm wide, and 3.5mm thickness. 10 specimens of four resins were cured for 15 minutes at atmospheric pressure and 10 specimens of four resins were cured at an additional pressure of approximately 20 psi. A total of 80 specimens were prepared. The flexual strength was determined by three-point bending test. Data were analysed with the Paired samples T-test and Tukey student-range test Within the limitations imposed in this study, the following conclusions can be drawn : 1. Under the condition of bench curing, Caulk Temporary bridge resin showed the highest flexual strength. In decreasing order, the flexual strength of the other materials was as follows : Jet, Tokuso Curefast, Alike, and Caulk Temporary bridge resin demonstrated significantly higher strength than other resins. 2. Under the condition of pressure curing, Jet showed the highest flexual strength. In decreasing order, the flexual strength of the other materials was as follows : Caulk Temporary bridge resin, Tokuso Curefast, and Alike. There were all statistically significant differences among four resins 3. There was a statistically significant difference between bench- and pressure-cured specimens in all four materials.

  • PDF

치과용 심미수복재료 세로모에서 수분흡수와 체적 변화에 관한 연구 (Dimensional Changes of Ceromer Crown by Water Absorption)

  • 이종혁
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.119-124
    • /
    • 2009
  • 연구목적: 치과 영역에서 환자들의 심미적인 요구가 증가하면서 자연 치아의 색조를 재현할 수 있는 수복물의 개발이 이루어졌으며, 이러한 연구의 일환으로 도재와 복합레진의 특성을 겸비한 Ceromer(Ceramic Optimized Polymer)가 개발되었다. Ceromer는 기존의 복합레진에 무기질을 고밀도로 충전하여 물리적 성질을 향상시켰다. 연구 재료 및 방법:본 실험에서는 두 종류의 Ceromer[$Targis^{(R)}$(Ivoclar-vivadent AG., Schaan, Liechtenstein), $BelleGlass^{(R)}$(Kerr Co., Orange, CA, USA)]를 이용해 레진 전장관 형태의 시편을 제작하고 증류수에 침전한 후 발생하는 체적과 중량의 변화를 관찰하였다. 결과 및 결론:두 종류의 Ceromer 모두 수중 침적 시간이 증가할수록 높이와 폭이 증가되었으며, $Targis^{(R)}$보다 $BelleGlass^{(R)}$에서 더 큰 누적변화율을 보였다. 72시간까지 급격한 증가를 보이다 이후 누적변화율의 증가는 감소하였다. 통계적 분석결과 $Targis^{(R)}$의 높이와 무게의 누적 변화량이 24시간군과 나머지군 사이에 유의한 차이를 보였으며, $BelleGlass^{(R)}$에서는 폭과 무게에서 누적 변화량이 24시간군과 나머지군 사이에 유의한 차이를 보였다(<.05). $Targis^{(R)}$$BelleGlass^{(R)}$ 두 군간의 비교에서는 높이, 폭, 무게의 변화량은 통계적으로 유의한 차이를 보이지 않았으나 변화양상은 다르게 관찰되었다.

복합레진 표면에 대한 APF gel의 영향 (EFFECT OF APF GEL ON THE SURFACE OF COMPOSITE RESIN)

  • 육근영;양규호;김선미;최남기
    • 대한소아치과학회지
    • /
    • 제33권1호
    • /
    • pp.43-52
    • /
    • 2006
  • 소아의 치아우식증을 예방하기 위한 불소의 국소도포는 소아치과 영역에서 널리 시행되고 있다. 하지만 이러한 잇점에도 불구하고 최근 수복물 표면을 거칠게 한다는 부작용에 대해 논란이 되고 있다. 이에 본 연구에서는 불소도포가 심미 수복물의 표면변화에 미치는 영향을 평가하기 위해 수종의 복합레진에 국소도포용 불소젤을 도포시킨 후 변화를 관찰하였다. 시판용 레진인 Z 250(3M ESPE, USA) Ultraseal $XT^{(R)}$(Ultradent, USA), Filtek $flow^{(R)}$(3M, USA), $Revolution^{(R)}$(Kerr, USA), Denfil(Vericom, Korea)를 이용하여 시편을 제작하고, 불소젤은 $Topex^{(R)}$(Sultan Dental Products, Canada)을 각각 1분과 4분 동안 도포시켰다. 각 제품마다 불소젤을 도포하지 않은 5개의 시편을 대조군으로 사용하였다. 그 후 이 시편들의 표면 거칠기$(R_a\;value,\;{\mu}m)$와 무게 차이를 측정하고 주사전자현미경을 이용하여 다음과 같은 결과를 얻었다. 1. 불소젤을 도포시키지 않은 대조군에서 가장 평활한 표면을 보였으며 1분군, 4분군 순으로 표면 거칠기가 증가하였다. 그리고 Revolution을 제외한 모든 제품에서 유의한 차이를 보였다(p<0.05). 2. 국소도포용 불소젤을 도포한 각 레진 시편의 무게 차이를 비교한 결과 대조군, 1분군, 4분군 간에 유의한 차이는 없었다(p>0.05). 3. 주사전자현미경 관찰시 불소젤에 도포시킨 실험군은 대조군에 비해 거친 표면을 나타냈다. 이상의 결과로 국소적 불소도포는 복합레진의 표면 거칠기에 영향을 미치며 이를 고려하여 사용한다면 4분보다는 1분간의 불소도포법을 이용하는 것을 추천할 수 있을 것으로 사료된다.대구치의 원심경사는 필연적으로 일어나며, 이를 최소화하기 위한 노력이 계속되어야 할 것으로 사료된다.글래스 아이오노머 시멘트 사이에는 유의한 차이가 없었다.착제의 종류에 따른 전단결합강도를 비교한 결과, 영구치와 유치 모두에서 Clearfil SE Bond를 사용한 군의 전단결합강도가 가장 높았으며 AQ Bond를 사용한 군의 전단결합강도가 가장 낮았다.본에서 III군에 비해 크기가 큰 기포가 더욱 많이 관찰되었다.e의 약동학은 cimetidine에 의해 유의한 차이를 보였으며 CYP1A2유전자형에 따른 영향은 관찰할 수 없었다. CYP1A2유전자형에 따른 생체내 대사능을 관찰하는 실험이 향후 이루어 져야 할 것으로 사료된다.san film보다 큰 수증기 투과도를 보였다.적으로 유의한 차이를 보이지 않았다.y tissue layer thinning은 3 군모두에서 관찰되었고 항암 3 일군이 가장 심하게 나타났다. 이상의 실험결과를 보면 술전 항암제투여가 초기에 시행한 경우에는 조직의 치유에 초기 5 일정도까지는 영향을 미치나 7 일이 지나면 정상범주로 회복함을 알수 있었고 실험결과 항암제 투여후 3 일째 피판 형성한 군에서 피판치유가 늦어진 것으로 관찰되어 인체에서 항암 투여후 수술시기는 인체면역계가 회복하는 시기를 3주이상 경과후 적어도 4주째 수술시기를 정하는 것이 유리하리라 생각되었다.한 복합레진은 개발의 초기단계이며, 물성의 증가를 위한 연구가 필요할 것으로 사료된다.또 다른 약물인 glycyrrhetinic acid($100{\mu}M$)도 CCh 자극으로 인한 타액분비를 억제하였다. 이상의 결과로 미루어 gap junction은 흰쥐 악하선 세포로부터의 타액분비 조절에 중요한 역할을 하는데, 이는 gap junction이 세포막 $Ca^{2+}$ 통로를 조절함으로써 수용체 자극으로 유발된 세포내 $Ca^{2+}$ 농도 변화에

  • PDF

Giomer와 자가 산부식 접착제의 상아질에 대한 전단 결합강도 (SHEAR BOND STRENGTH OF GIOMER AND SELF-ETCHING PRIMER ON THE DENTIN)

  • 윤은영;이난영;이상호
    • 대한소아치과학회지
    • /
    • 제37권4호
    • /
    • pp.422-428
    • /
    • 2010
  • Giomer는 글라스 아이오노머 시멘트의 불소 방출 능력과 복합레진의 물성을 동시에 가지고 있는 새로운 형태의 재료로서 소개되었다. 이에 본 연구에서는 giomer의 전단 결합강도를 기존의 심미 수복재료인 복합 레진과 컴포머와 비교하여 심미 수복재료로서의 임상적 효용성을 평가하고자 한다. 소의 전치를 자가중합 교정용 레진을 이용하여 아크릴 튜브에 매몰시킨 후, 상아질을 노출시키기 위해 실리콘 페이퍼를 이용하여 표면을 연마하였다. 샘플을 무작위로 I군(Giomer), II군(복합 레진), III군(컴포머), IV군(Giomer와 5세대 단일병 접착제)으로 분류하였다. 만능 시험기를 이용하여 각 샘플의 전단 결합강도를 측정하였다. One-way ANOVA와 Scheffe test를 이용하여 통계분석을 시행하였다. I군은 III군에 비해 통계학적으로 유의하게 높은 전단 결합강도를 나타냈다(p<0.05). I군과 II군의 전단 결합강도는 통계학적으로 유의한 차이가 없었다(p>0.05). IV군는 I군에 비해 낮은 결합강도를 보였지만, 통계학적으로 유의한 차이는 없었다(p>0.05). 실험의 결과로 보아 불소 방출의 특성을 지닌 giomer의 결합강도가 컴포머에 비해 우수하고, 복합 레진과 유사한 것으로 나타남으로써 소아 환자의 심미수복재료로서의 임상적 효용성이 있다고 사료된다.

도재인레이 하방에서 광중합형 복합레진과 이중중합형 복합레진시멘트의 미세경도와 중합률에 관한 연구 (THE MICROHARDNESS AND THE DEGREE OF CONVERSION OF LIGHT CURED COMPOSITE RESIN AND DUAL CURED RESIN CEMENTS UNDER PORCELAIN INLAY)

  • 김승수;조성식;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.17-40
    • /
    • 2000
  • Resin cements are used for cementing indirect esthetic restorations such as resin or porcelain inlays. Because of its limitations in curing of purely light cured resin cements due to attenuation of the curing light by intervening materials, dual cured resin cements are recommended for cementing restorations. The physical properties of resin cements are greatly influenced by the extent to which a resin cures and the degree of cure is an important factor in the success of the inlay. The purpose of this study was to evaluate the influence of porcelain thickness and exposure time on the polymerization of resin cements by measuring the microhardness and the degree of conversion, to investigate the nature of the correlation between two methods mentioned above, and to determine the exposure time needed to harden resin cements through various thickness of porcelain. The degree of resin cure was evaluated by the measurements of microhardness [Vickers Hardness Number(VHN)] and degree of conversion(DC), as determined by Fourier Transform Infrared Spectroscopy(FTIR) on one light cured composite resin [Z-100(Z)] and three dual cured resin cements [Duo cement(D), 3M Resin cement(R), and Dual cement(DA)] which were cured under porcelain discs thickness of 0mm, 1mm, 2mm, 3mm with light exposure time of 40sec, 80sec, 120sec, and regression analysis was performed to determine the correlation between VHN and DC. In addition, to determine the exposure time needed to harden resin cements under various thickness of porcelain discs, the changes of the intensity of light attenuated by 1mm, 2mm, and 3mm thickness of porcelain discs were measured using the curing radiometer. The results were obtained as follows ; 1. The values of microhardness and the degree of conversion of resin cements without intervening porcelain discs were 31~109VHN and 51~63%, respectively. In the microhardness Z was the highest, followed by R, D, DA. In the degree of conversion, D and DA was significantly greater than Z and R(p<0.05). 2. The microhardness and the degree of conversion of the resin cements decreased with increasing thickness of porcelain discs, and increased with increasing exposure time, D and R showed great variation with inlay thickness and exposure time, whereas, DA showed a little variation. 3. The intensity of light through 1mm, 2mm, and 3mm porcelain inlays decreased by 0.43, 0.25, and 0.14 times compared to direct illumination, and the respective needed exposure times are 53 sec, 70 sec, and 93 sec. In D and R, 40 sec of light irradiation through 2mm porcelain disc and 80 sec of light irradiation through 3mm porcelain disc were not enough to complete curing. 4. The microhardness and the degree of conversion of the resin cements showed a positive correlationship(R=0.791~0.965) in the order of R, D, Z, DA. As the thickness of porcelain discs increased, the decreasing pattern of microhardness was different from that of the degree of conversion, however.

  • PDF

광중합형 복합레진의 화학적 분해와 마모에 관한 연구 (CHEMICAL DEGRADATION AND WEAR OF LIGHT-CURED COMPOSITE RESINS)

  • 양규호;정희경;최남기;김선미
    • 대한소아치과학회지
    • /
    • 제34권2호
    • /
    • pp.273-284
    • /
    • 2007
  • 본 연구는 광중합형 복합레진 Composan LCM Flow(Promedica, Germany), Clearfil ST(Kuraray medical, Japan) Durafil VS(Heraeus Kulzer, U.S.A), Point 4(Kerr, U.S.A)를 사용하여 각 제품의 물리적, 화학적 평가를 하고자 하였다. 마모시험 후 마모된 면의 깊이를 측정하였고 0.1N NaOH에 보관 후. 각 제품의 분해저항성을 무게손실, 표면하 분해층 깊이, 용출된 Si 농도를 기준으로 평가하였으며 주사전자현미경과 공촛점 레이저 현미경으로 분해 층을 관찰하여 다음과 같은 결과를 얻었다. 1. 무게 손실량은 $1.02{\sim}6.04%$까지 다양하였으며 Durafil VS에서 가장 높았다$(6.04{\pm}0.29%)$. 2. 분해층 깊이는 Durafil VS이 가장 깊었고 Clearfil ST, Point 4, Composan LCM Flow순이었고 Point 4와 Composan LCM Flow는 다른 제품과 유의한 차이를 보였다(p<0.001). 3. Si 용출량은 Clearfil ST가 가장 많았으며 Durafil VS, Composan LCM Flow, Point 4 사이에 유의한 차이를 보였다(p<0.001). 4. 주사전자현미경 관찰시 표면 양상 및 분해층 깊이를 관찰할 수 있었고 공촛점 레이저 현미경 관찰시 NaOH 용액에 보관한 후 수복재의 기질과 충전제 사이의 결합의 파괴 양상을 관찰할 수 있었다. 5. 최대마모깊이는 Durafil VS, Composan LCM Flow, Point 4, Clearfil ST 순으로 낮았으며 유의한 차이를 보이지 않았다(p>0.001). 6. 각 제품의 Si 용출량과 분해층 깊이 사이(r=0.892, p<0.01), Si 용출량과 무게손실 사이(r=0.736, p<0.01)에는 유의한 상관관계를 보였다.

  • PDF