• Title/Summary/Keyword: esthetic analysis

Search Result 315, Processing Time 0.025 seconds

The Structural Relationship between SNS Tourism Information Value, Perceived Risk, and Tourism Destination Switching Behavior (SNS관광정보가치와 지각된 위험, 관광지 전환행동 간 구조적 관계 연구)

  • Choi, Jae-Woo;Oh, Kyung-Taek;Lee, Chul-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.524-533
    • /
    • 2015
  • This study aims to prove the value of SNS tourism information by confirming the relation between SNS tourism information and perceived risk and by verifying its influence on the intention to switch tourism destination. The data was collected from 302 tourists. For data analysis, SPSS 18.0 program and AMOS 18.0 were conducted. First, functional characteristics of SNS tourism information have been verified to have no relationship with the tourist's perception of risk, and therefore the functional tourism information is thought to cause individual motive regardless of tourist's perception of risk. Second, aesthetic value and economic benefits of SNS tourism information have been analyzed to reduce perceived risk of tourists. Third, a symbol of SNS Tourism information has proved to be an element that increases the risk perceived by tourists, indicating that various kinds of tourism information provided by other channels including SNS can serve as a momentum to make tourists recognize new risks the other way round as new tourism information is accumulated, which acts as new motivating factor.

A STUDY ON THE PHYSICAL PROPERTIES OF GLASS IONOMER CEMENT FOR RESTORATIVE FILLING USING VISIBLE LIGHT POLYMERIZATION (가시광선중합화에 따른 충전용 Glass Ionomer Cement의 물리적 성질에 관한 연구)

  • Shin, Dong-Hoon;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.307-330
    • /
    • 1992
  • The aim of this study was to investigate the physical properties of visible light curing Glass Ionomer cement for restorative esthetic filling. The control group was the autopolymerizing GC Fuji II Glass Ionomer cement (2.2: 1 P/L ratio) and the experimental groups were made by following procedure. To induce the polymerization by visible light, the powder of GC Fuji II GI cement and the liquid of Vitrabond for base & liner were mixed in an amalgam capsule with 2.5:1, 3.0:1, 3.5:1 P/L ratio (% wt/wt). After fabrication of specimens, compressive strength, fracture toughness ($K_{IC}$) Scanning Electron Microscope and X-ray Diffraction, water-leachable content, marginal leakage and surface roughness were studied. The results were as follows: 1. Only experimental No. 1 group (visible light curing) showed less compressive strength than control group 1 hour after curing. Strength was increased with aging in all groups, so the compressive strength of light curing groups was no less than that of autopolymerizing group after 3 weeks. 2. Experimental No.3 group (visible light curing) was inferior to No.2 group (visible light curing) in fracture resistance but light curing groups were more resistant to fracture than autopolymerizing group and showed ductile fracture pattern as compared with the brittle fracture pattern of autopolymerizing group. 3. From scanning electron microscopic image, various sized unreacted powder particles, surrounded by silica gel, were embedded in polysalt matrix. Light curing groups showed little crack and more dense unreacted particles than autopolymerizing group. 4. From X-ray diffraction analysis, GC Fuji II Glass Ionomer cement powder and all groups showed glassy appearance but light curing groups seemed to be more intensive in crystaline than autopolymerizing group. S. The most significant dissolution was shown in early setting period in all group. Light curing groups were dissolved less than autopolymerizing group. 6. Marginal leakage was not different significantly in case of cavity margin composed of same tooth structure (ex. only enamel margin, only dentin margin) but much more leakage was shown in dentin/cementum margin than enamel margin. In only case of only enamel margin, light curing groups were superior to autopolymerizing group. 7. All groups showed relatively smooth surface, which irregularity was less than $1{\mu}m$. Light curing groups were smoother than autopolymerizing group.

  • PDF

THE EFFECT OF SOLDER AND LASER WELD ON CORROSION OF DENTAL ALLOYS (납착법과 레이저융합법이 치과용 합금의 부식에 미치는 영향)

  • Baik Jin;Woo Yi-Hung;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.264-279
    • /
    • 2005
  • Statement of problem. Intraoral corrosion not only affects the esthetic and function of metallic dental restoration, but also has biologic consequences as well. Therefore, corrosion is considered a primary factor when choosing the dental alloy and laboratory technique. Purpose. The objective of this study was to compare the effects of solder and laser weld on corrosion Material and methods. Test specimens were made of 2 types of gold alloys, Co-Cr and Ni-Cr alloy and fabricated 3 methods, respectively: as cast, solder, and laser weld. For the analysis of corroding properties, potentiodynamic polarization test and immersion test conducted. The potentiodynamic polarization scan curve were recorded in 0.9% NaCl solution(pH 7) using Potentiostat/Galyanostat Model 273A. All specimens were exposed to 0.9% NaCl solution(pH 2.3) during 14 days. Elemental release into corrosive solution was measured by atomic emission spectrometry Differences in corrosion potential and mass release were determined using ANOVA. Results and conclusion. Through analyses of the data, following results were obtained. 1. In Pontor MPF and Wiron 99, corrosion potential of the solder group was statistically lower than as cast and laser weld group (p<0.05) , but there was no difference between corrosion potential of solder group and laser weld group in Pontor MPF and no differences between as cast and laser weld group (p>0.05). In Jel-Bios 10 and Wirobond, there was no difference of corrosion potential according to joining methods(p>0.05). 2. In all tested alloys, the amount of released metallic ion was greatest in the solder group(p<0.05). There was no difference between as cast group and laser weld group in Jel-Bios 10 and Wirobond(p>0.05). 3. In scanning electron microscopic examination. except soldered Wiron 99 specimens, it is impossible to discriminate the corrosive property of solder and laser weld. 4. Under the this experimental circumstances, laser weld appears superior to the solder when corrosion is considered.

COLOR STABILITY OF CEROMERS IN THREE FOOD COLORANTS (식용색소에 의한 CEROMER 수복물의 색안정성)

  • Jeong Yu-Jin;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.136-147
    • /
    • 2003
  • Statement of problem : Ceramic and composite resin have been used to fulfill the demand for esthetic prosthesis. However, ceramic is easy to break and wears off the opposite natural teeth. Conventional composite resin also has low abrasive resistance and color stability. Ceramic Optimized Polymer (ceromer) was developed in mid-1990s to overcome the shortfalls of ceramic and composite resin. Ceromer has similar abrasiveness with the natural tooth and has relatively high strength. Color stability affects esthetics and long-term prognosis of the prosthesis. Purpose The purpose of this study was to compare color stability of ceromers(2 types : $Artglass^{(R)}$. $Targis^{(R)}$) with ceramics ($Vintage^{(R)}$-polishing, $Vintage^{(R)}$-glazing). Material and Method : The color difference(${\Delta}E^*$) was measured by spectrophotometer with different immersion time. Twenty disks, 3mm in thickness and 10mm in diameter, were fabricated for each specimen in shade A2(Vita Lumin shade guide), Specimens (5 samples in each group) were immersed in the food colorants (Red no.3. Yellow no.4, Blue no.1, Distilled water) for 24 hours, 48 hours and 72 hours respectively. $L^*,\;a^*$ and $b^*$ value were measured with spectrophotometer (CM 503i : Minolta Co., Japan) and mean ${\Delta}E^*$ value was calculated for statistical analysis Results : The results of this study were obtained as follows. 1. The ${\Delta}E^*$ values of all test samples increased with the time of immersion. 2. The ${\Delta}E^*$ values of all materials increased in order of Distilled Water, Yellow no.4, Blue no.1 and fed no.3. There was significant difference between Red no.3 and the other food colorants(p<0.05). 3. The ${\Delta}E^*$ values increased in order of $Vintage^{(R)}$-glazing, $Vintage^{(R)}$-polishing. $Artglass^{(R)}$ and $Targis^{(R)}$. There was significant difference between $Vintage^{(R)}$-glazing and the other materials (p<0.05). Conclusion : By means of the above results, immersion time was found to be a critical factor for color stability of ceromer. For the long-term color stability of prosthesis it is recommended patients having ceromer prosthesis ($Artglass^{(R)},\;Targis^{(R)}$) to reduce the habitual intake of Red no.3 colorants con taming foods.

THE MICROHARDNESS AND THE DEGREE OF CONVERSION OF LIGHT CURED COMPOSITE RESIN AND DUAL CURED RESIN CEMENTS UNDER PORCELAIN INLAY (도재인레이 하방에서 광중합형 복합레진과 이중중합형 복합레진시멘트의 미세경도와 중합률에 관한 연구)

  • Kim, Seung-Soo;Cho, Sung-Sik;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.17-40
    • /
    • 2000
  • Resin cements are used for cementing indirect esthetic restorations such as resin or porcelain inlays. Because of its limitations in curing of purely light cured resin cements due to attenuation of the curing light by intervening materials, dual cured resin cements are recommended for cementing restorations. The physical properties of resin cements are greatly influenced by the extent to which a resin cures and the degree of cure is an important factor in the success of the inlay. The purpose of this study was to evaluate the influence of porcelain thickness and exposure time on the polymerization of resin cements by measuring the microhardness and the degree of conversion, to investigate the nature of the correlation between two methods mentioned above, and to determine the exposure time needed to harden resin cements through various thickness of porcelain. The degree of resin cure was evaluated by the measurements of microhardness [Vickers Hardness Number(VHN)] and degree of conversion(DC), as determined by Fourier Transform Infrared Spectroscopy(FTIR) on one light cured composite resin [Z-100(Z)] and three dual cured resin cements [Duo cement(D), 3M Resin cement(R), and Dual cement(DA)] which were cured under porcelain discs thickness of 0mm, 1mm, 2mm, 3mm with light exposure time of 40sec, 80sec, 120sec, and regression analysis was performed to determine the correlation between VHN and DC. In addition, to determine the exposure time needed to harden resin cements under various thickness of porcelain discs, the changes of the intensity of light attenuated by 1mm, 2mm, and 3mm thickness of porcelain discs were measured using the curing radiometer. The results were obtained as follows ; 1. The values of microhardness and the degree of conversion of resin cements without intervening porcelain discs were 31~109VHN and 51~63%, respectively. In the microhardness Z was the highest, followed by R, D, DA. In the degree of conversion, D and DA was significantly greater than Z and R(p<0.05). 2. The microhardness and the degree of conversion of the resin cements decreased with increasing thickness of porcelain discs, and increased with increasing exposure time, D and R showed great variation with inlay thickness and exposure time, whereas, DA showed a little variation. 3. The intensity of light through 1mm, 2mm, and 3mm porcelain inlays decreased by 0.43, 0.25, and 0.14 times compared to direct illumination, and the respective needed exposure times are 53 sec, 70 sec, and 93 sec. In D and R, 40 sec of light irradiation through 2mm porcelain disc and 80 sec of light irradiation through 3mm porcelain disc were not enough to complete curing. 4. The microhardness and the degree of conversion of the resin cements showed a positive correlationship(R=0.791~0.965) in the order of R, D, Z, DA. As the thickness of porcelain discs increased, the decreasing pattern of microhardness was different from that of the degree of conversion, however.

  • PDF

Convergence Study on Damage and Static Fracture Characteristic of the Bonded CFRP structure with Laminate angle (적층 각도를 가진 CFRP 접착 구조물의 파손 및 정적 파괴 특성에 관한 융합 연구)

  • Lee, Jung-Ho;Kim, Eundo;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.1
    • /
    • pp.155-161
    • /
    • 2019
  • As composite is the light weight material whose durability and mechanical property are more superior than the existing general material. By taking notice of the composite with light weight, this study was about to investigate the static fracture characteristic of the bonded CFRP structure jointed with adhesive. Also, CFRP double cantilever beam with the variable of laminate angle was designed and the static fracture analysis was carried out. The laminate angles of CFRP double cantilever beam designed for this study were $30^{\circ}$, $45^{\circ}$ and $60^{\circ}$ individually. As the study result, the specimen with the laminate angle of $45^{\circ}$ was shown to have the durability better than those with the layer angles of $30^{\circ}$ and $45^{\circ}$. It was checked that the specimen with the laminate angle of $30^{\circ}$ had the weakest durability among all specimens. The damage data of the bonded CFRP structure by laminate angle could be secured through this study result. As the damage data of bonded interface obtained on the basis of this study result are utilized, the esthetic sense can be shown by being grafted onto the machine or structure at real life.

Implant treatment on anterior cross-bite of a patient who had orthognathic surgery 20 years ago (20년전 악교정수술을 받았던 환자의 심한 전치부 반대교합의 해결을 위한 임플란트 치료 증례)

  • Park, Kwang Man;Leesungbok, Richard;Lee, Suk Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.245-253
    • /
    • 2019
  • Orthognathic surgery of skeletal Class III malocclusion improves oral function and facial appearance. The greater amount of skeletal discrepancy, the greater amount of teeth movement required for decompensation, and this often causes pathological changes in periodontal tissue especially in lower anterior dentition. We made a Top-Down treatment plan with personalized analysis using Face Hunter, Plane System and ARCUS Digma II, in order to resolve severe mobility and cross-bite of lower anterior teeth for 49-year-old female patient who had undergone orthognathic surgery 20 years ago due to skeletal Class III malocclusion and mandibular prognathism. Lower anterior teeth were extracted and alveoloplasty was done. After healing of the wound, immediate loading was conducted immediately after implant placement. Final restorations were fabricated Zirconia using CAD/CAM, and inserted intraorally screw-retained type. During 6-month follow-up, no abnormal episodes of restorations were observed, and obtained satisfactorily both of functional and esthetic outcomes.

A case of oral rehabilitation with increasing vertical dimension for a patient with loss of posterior teeth support (구치부 지지 상실을 보이는 환자에서 수직고경 거상을 동반한 구강 회복 증례)

  • Kim, Hyun-Hwi;Lee, Jong-Hyuk;Ha, Seung-Ryong;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.404-411
    • /
    • 2022
  • The patient in this case was an 80-year-old female who had lost #16, 13, 26, 37, 36, 35, 44, 45, 46, 47 teeth. The patient showed loss of posterior support, loss of vertical dimension of occlusion, and deep anterior overbite. Her chief complaint was esthetic and functional discomfort. She wanted to restore normal facial aesthetic shape and masticatory function through prosthetic treatment. Clinical evaluation, radiographic examinations, and facial and oral analysis were performed. Interocclusal rest space was excessive than the average. Distance between labial vestibules and zenith of central incisors, and lower facial ratio were below the average. Taken together, occlusal rehabilitation was determined through increasing 4 mm of vertical dimension on premolars. In this case, a patient who lacked restoration space with deep bite in the anterior region due to loss of the posterior teeth support restored a stable occlusal relationship and harmonious anterior and lateral guidance through fixed and removable prosthesis with increased vertical dimension.

Rehabilitation with minimal increase in occlusal vertical dimension in a patient with excessive tooth wear and edge-to-edge bite (과도한 치아 마모와 절단교합을 보이는 환자에서 최소한의 수직 고경 증가를 통한 구강회복 증례)

  • Hee-Young Kim;Seong-A Kim;Yong-Sang Lee;Keun-Woo Lee;Joo-Hyuk Bang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.143-152
    • /
    • 2023
  • Although tooth wear is a normal process due to aging, severe tooth wear causes various complications such as increased tooth sensitivity, loss of tooth structure, and pulp complications. In the treatment of patients with excessive tooth wear, the evaluation of loss of vertical occlusal dimension should be prioritized. If it is necessary to increase the vertical dimension to secure the restoration space, it is important to establish a treatment plan with the comprehensive analysis and determine the minimum vertical dimension elevation. In this case, 66-year-old male patient with severe worn dentition wanted to restore masticatory function and improve esthetic restoration. In order to determine the appropriate vertical dimension of the patient, we evaluated oral examination, radiographic examination, and diagnostic cast examination, and performed rehabilitation with minimum vertical dimension elevation. As a result of observation for 8 months, the definitive prosthesis was completed with contact of all teeth in centric occlusion, and proper anterior/posterior guidance. Through the above process, satisfactory aesthetic and functional outcomes were obtained.

Customized maxillary incisor position relative to dentoskeletal and soft tissue patterns in Chinese women: A retrospective study

  • Zhou, Xueman;Zheng, Yingcheng;Zhang, Zhenzhen;Zhang, Zihan;Wu, Lina;Liu, Jiaqi;Yang, Wenke;Wang, Jun
    • The korean journal of orthodontics
    • /
    • v.52 no.2
    • /
    • pp.150-160
    • /
    • 2022
  • Objective: To provide reliable prediction models based on dentoskeletal and soft tissue variables for customizing maxillary incisor positions and to optimize digitalized orthodontic treatment planning. Methods: This study included 244 Chinese women (age, 18-40 years old) with esthetic profiles after orthodontic treatment with fixed appliances (133 in group I: 1° ≤ The angle between the nasion [N]-A point [A] plane and the N-B point [B] plane [ANB] ≤ 4°; 111 in group II: 4° < ANB ≤ 7°). Dental, skeletal, and soft tissue measurements were performed on lateral cephalograms of the participants. Correlation and multiple linear regression analyses were used to determine the influence of dentoskeletal and soft tissue variables on maxillary incisor position. Results: The ideal anteroposterior position of the maxillary incisor varied between sagittal skeletal patterns. The position of the maxillary incisor correlated with the sagittal discrepancy between the maxilla and the mandible (ANB), protrusion of the midface, nasal tip projection, development of the chin, and inclination of both the maxillary and mandibular incisors. Distance from the maxillary central incisor to nasion-pogonion plane predicted using multiple linear regression analysis was accurate and could be a practical measurement in orthodontic treatment planning. Conclusions: Instead of using an average value or norm, orthodontists should customize a patient's ideal maxillary incisor position using dentoskeletal and soft tissue evaluations.