• 제목/요약/키워드: escape ramp

검색결과 6건 처리시간 0.019초

Analysis of Rana coreana Behavior According to the Slope Angle Degree of Escape Ramp (콘크리트 수로 탈출로 경사각에 따른 한국산개구리 행동 분석)

  • Lee, Taeho;Kim, Jungkwon;Seo, Jihye;Jang, Moonjeong;Choi, Taeyoung;Chang, Minho
    • Journal of Environmental Impact Assessment
    • /
    • 제31권1호
    • /
    • pp.75-81
    • /
    • 2022
  • The purpose of this study is to propose the angle-limit of the escape ramp by analyzing the frog behavior characteristics according to the inclination angle of the waterway escape ramp installed in the concrete U-bench plume pipe channel. Forthe experiment, an escape test device was manufactured with the same shape and number of materials applied in the field. And Rana coreana living in paddy wetlands were sel selected. The main behaviors of frogs on the slope were 'jumping', 'crawling' and 'slipping', and afterrecording the behavioralresults according to the inclination angle, statistical analysis was conducted using the chi-square test method. As a result of the analysis, there was no statistically significant difference between 30° and 40°. This result is an evidence for expanding the standard of inclination angle 30° suggested in the 'Guidelines for Installation and Management of Ecological Pathways' to a maximum of 40°. However, further research is required in that the escape ramp targets not only Korean frogs but also various small wild animals. However, considering that various wild animals are affected by artificial canals, additional studies using various target wild animals are needed.

Related Facilities for the Safety from a State of Emergency (철도차량 비상상황과 안전을 위한 관련 설비)

  • Jung, Dong-Suk;Song, Young-Jeong;Woo, Yi-Wan
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1389-1396
    • /
    • 2011
  • There can be several states of emergency when the train is in operation. In this paper we consider passengers how to escape from emergency states and what facilities they can use by each situation. In general, passengers can escape from a train by manual door openning, emergency ramp and breaking window. Now, we consider which facility is proper to each scenario.

  • PDF

Thermal Excitations in Nb Josephson Junctions (Nb 조셉슨 접합의 열적 여기현상)

  • 김동호;황준석
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.75-77
    • /
    • 2003
  • We have measured the escape rates of the Nb Josephson junction from its zero-voltage state. The critical current measurements were carried out in repeatedly sweeping the current-voltage characteristics of the junction with a current ramp. From the distribution of the critical current the escape temperature was determined by applying the thermal activation model.

  • PDF

Design of Truck Escape Ramps (자동차 긴급 피난 차선의 계획 설계)

  • 구본충
    • Journal of the Korean Professional Engineers Association
    • /
    • 제28권4호
    • /
    • pp.54-75
    • /
    • 1995
  • This synthesis has been prepared from a review of literature on Truck Escape Ramps technology and a survey of current practice by state department of transportation. Their locations have been determined usually from a combination of accident experience and en-gineering judgement, but new tools are emerging that can identify needs and sites without waiting for catastrophic accidents to happen. The Grade Severity Rating Systems holds promise in this regard. Design Procedures for truck excape ramps continue to evolve. Gravel arrester beds are clearly the preferred choice across the country Rounded aggregate, uniformly graded in the approximate size range of 13 to 18mm. Tech-nical publications typically have dassified TER types as paved gravity, sandpile, and ar-rester bed ramps. The design speed for vehicle entry into the ramp in critical to the deter-mination of ramp length. An escape ramp should be designed for a minimum entry speed of 130km/hr, a 145km/hr design being preferred. The ramps should be straight and their angle to the roadway align-ment should be as possible. The grade of truck escape ramps show the adjustment of ramp design to local topography, such as the tradeoff of ramp length against earthwork requirements. A width of 9 to 12m would more safety acommodate two or more outof con-trol vehicles. Reguarding comments on the most effective material, most respondents cited their own specification or referred to single graded, rounded pea gravel. The consensus essentially Is that single graded, well -rounded gravel is the most desirable material for use in arrester beds. The arrester beds should be constructed with a minimum aggregate depth of 30cm. Successful ramps have used depths between 30 and 90cm.

  • PDF

Numerical Investigation of Effect of Opening Pattern of Flow Control Valve on Underwater Discharge System using Linear Pump (유량제어밸브 개방형태가 선형펌프 방식 수중사출 시스템에 미치는 영향에 관한 수치적 연구)

  • Lee, Sunjoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • 제22권2호
    • /
    • pp.255-265
    • /
    • 2019
  • In the present study, the effect of opening patterns of a flow control valve on underwater discharge systems using a linear pump was investigated numerically. For that, a improved mathematical model was developed. The improvement is to separate a middle tank from a water cylinder because the cross-section area of the inlet of the middle tank is an important parameter. To validate the improved model, calculation results were compared with a previous study. The results showed that $2^{nd}$ order or more polynomial opening patterns had an advantage over ramp opening patterns. Higher an order of polynomial resulted in wider operating limits. An escape velocity and a maximum acceleration of underwater vehicle were affected by time derivative of the cross-section area of the flow control valve. Besides, as a velocity profile of the vehicle got closer to linearity, the escape velocity got faster and the maximum acceleration got smaller. And velocities of the vehicle and piston had similar variation trend.

A Study on the Evacuation Performance Analysis Model Considering Clustering Types at the Fire Event in Geriatric Hospital (노인 요양병원에서 화재 시 군집유형에 따른 피난 성능 분석 모델에 관한 연구)

  • Kim, Mijung;Kweon, Jihoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • 제28권1호
    • /
    • pp.63-74
    • /
    • 2022
  • Purpose: The purpose of this study is to present an evacuation performance analysis model that can derive vulnerable evacuation spaces with considering the movement behavior as per the elderly groups in the event of a fire in a geriatric hospital. Methods: The evacuation characteristics of geriatric hospital users were investigated through the review of precedent studies. First, the occupant conditions and the evacuation scenario were set to analyze a study target hospital. Then, the evacuation simulation was carried out considering the group types and the density of each group. Finally, an evacuation performance analysis model according to the group type was presented based on the simulation results. Results: The results of this study are as follows: (1) The evacuation performance according to the group type is to be clarified through the suggested study model. (2) It is necessary to secure a ramp or an emergency elevator to distribute the evacuation personnel at the design stage because congestion occurs due to collisions between evacuees on the stairs and delays the evacuation time. (3) It is necessary to consider the evacuation stairs and openings of sufficient size by analyzing the frequency of congestion occurrence and the escape routes of occupants in advance to identify the space where the evacuation flow overlaps. Implications: It is expected that the study result is to be used as primary data for studies that consider the elderly and clustering evacuation behavior in the event of a fire in a geriatric hospital.