• Title/Summary/Keyword: error sensor

검색결과 2,235건 처리시간 0.031초

링 레이저 자이로스콥을 위한 유한요소법 기계 설계 (Mechanical Design of Ring Laser Gyroscope Using Finite Element Method)

  • 이정익
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.107-111
    • /
    • 2013
  • The gyroscopes have been used as a suitable inertial instrument for the navigation guidance and attitude controls. The accuracy as very sensitive sensor is limited by the lock-in region (dead band) due to the frequency coupling between two counter-propagating waves at low rotation rates. This frequency coupling gives no phase difference, and an angular increment is not detected. This problem can be overcome by mechanically dithering the gyroscope. This paper presents the design method of mechanical dither by the theoretical considerations and the verification of the theoretical equations through FEM applications. As a result, comparing to the past result, the maximum prediction error of resonant frequency was within 3 percent and peak dither rate was within 5 percent. It was found that the theoretical equations can be feasible for the mechanical performance of dither.

다수의 계수구역간의 검사체적을 이용한 소형 세포농도센서 (Micro Cell Counter Using a Fixed Control Volume Between Double Electrical Sensing Zones)

  • 이동우;이소연;조영호
    • 대한기계학회논문집A
    • /
    • 제29권12권
    • /
    • pp.1615-1620
    • /
    • 2005
  • We present a novel flow-rate independent cell counter using a fixed control volume between double electrical sensing zones. The previous device based on the single electrical cell sensing in a given flow-rate requires an accurate fluid volume measurement or precision flow rate control. The present cell counter, however, offers the flow-rate independent method for the cell concentration measurement with counting cells in a fixed control volume of $22.9{\pm}0.98{\mu}{\ell}$. In the experimental study, using the RBC (Red Blood Cell), we have compared the measured RBC concentrations from the fabricated devices with those from Hemacytometer. The previous and present devices show the maximum errors of $20.3\%\;and\;16.1\%$, which are in the measurement error range of Hemacytometer (about $20\%$). The present device also shows the flow-rate independent performance at the constant flow-rates ($5{\mu}{\ell}/min$ and $10{\mu}{\ell}/min$) and the varying flow-rate (4, 2, and $4{\mu}{\ell}/min$). Therefore, we demonstrate that the present cell counter is a simple and automated method for the cell concentration measurement without requiring an accurate fluid measurement and precision flow-rate control.

AE에 의한 압력용기의 안전성평가에 관한 연구 (A Study on the Monitoring of Pressure Vessel Safety during Hydrotest by Acoustic Emission)

  • 이주석;조경식;최진민;장홍근;오세규
    • 비파괴검사학회지
    • /
    • 제8권1호
    • /
    • pp.12-21
    • /
    • 1988
  • The behaviour of pressure vessel made of SS41 steel was investigated during hydrotest. AE tests were carried out for the vessels in as-manufactured, V-notched and weld-cracked state using microcomputer-based AE instrumentation. The following results were obtained: 1) In the case of source location using cylindrical program, to minimize the error of source location, the difference of max. Delta T values measured from each sensor should be kept as small as possible. 2) When crack grew, AE event rate increased continuously but AE event from the inclusions occurred intermittently, so by analyzing event rate, the source of AE could be derived. 3) From the spot welding part of supporter, many events with low energy occurred independent of Kaiser effect, which could be confirmed by analyzing energy parameter. 4) The b-value from the tensile specimen of was lower than that from normal specimen and the b-value from crack propagation was lower than that from deformation, so by analyzing peak amplitude distribution, the source mechanism could be derived from the b-value.

  • PDF

ARM 920T 프로세서 기반의 초음파 폐활량계 구현 및 감도 향상 연구 (An Implementation of ARM 920T Processor-based Ultrasonic Spirometer and Improvement of Its Sensitivity)

  • 이철원;김영길
    • 비파괴검사학회지
    • /
    • 제25권4호
    • /
    • pp.268-273
    • /
    • 2005
  • 폐활량계(Spirometer)는 호흡하는 가스의 용적 유량의 순간적인 속도를 측정하는 의료기구로 폐의 기능시험과 환자 모니터링에 사용되며 용적 유량 신호를 합친 폐의 절대적인 용적변화를 측정한다. 본 논문에서는 환자를 대상으로 약한 호흡에서도 폐활량 측정이 가능하도록, 관성의 오차 및 압력의 오차에 영향을 거의 받지 않는 초음파 센서를 이용하여 송수신시 초음파 신호를 향상시켰으며, ARM 9207 프로세서를 사용하여 약한 호흡에도 정확하고 빠른 검출이 가능한 시스템을 구현하였다.

6축 힘/모멘트센서를 가진 인간형 로봇의 지능형 발 개발 (Development of Humanoid Robot's Intelligent Foot with Six-axis Force/Moment Sensors)

  • 김갑순;김현민;윤정원
    • 한국정밀공학회지
    • /
    • 제26권5호
    • /
    • pp.96-103
    • /
    • 2009
  • This paper describes a humanoid robot's intelligent foot with two six-axis force/moment sensors. The developed humanoid robots didn't get the intelligent feet for walking on uneven surface safely. In order to walk on uneven surface safely, the robot should measure the reaction forces and moments applied on the sales of the feet, and they should be controlled with the measured the forces and moments. In this paper, an intelligent foot for a humanoid robot was developed. First, the body of foot was designed to be rotated the toe and the heel to all directions, second, the six-axis force/moment sensors were manufactured, third, the high-speed controller was manufactured using DSP(digital signal processor), fourth, the humanoid robot's intelligent foot was manufactured using the body of foot, two six-axis force/moment sensors and the high-speed controller, finally, the characteristic test of the intelligent foot was carried out. It is thought that the foot could be used for a humanoid robot.

초정밀 마이크로 위치결정 스테이지의 제작 및 평가 (Experiment of the Precision micro-positioning stage)

  • 한창수;백석;노명규;이찬홍
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.244-247
    • /
    • 2002
  • The performance of the precision micro-positioning 4-dof stage is presented. The compact design utilizes the monolithic mechanism to achieve the translation in the Z axis and rotation in the $\theta$ z, $\theta$ x and $\theta$ y axes with high stiffness and high damping. Hysteresis, nonlinearity, and drift of the piezoelectric effects are improved by incorporating the sensors in a feedback control. Experiments demonstrate that the micro-positioning stage is capable of 2nm resolution over the travel range of 25$\mu\textrm$ m in the Z axis, 0.0l7 $\mu\textrm$ rad resolution over the 170$\mu\textrm$ rad in the $\theta$ z and 0.011 $\mu\textrm$ rad resolution over the $\mu\textrm$ rad in the $\theta$ x and $\theta$ y axes. The cross-axis interferences among the axes are at a noise range. This stage is available for positioning error compensation of the XY stage with large stroke.

  • PDF

등간격으로 배열된 마이크로폰을 이용한 관내 유량측정 방법 (A Method for the Measurement of Flow Rate in a Pipe Using a Microphone Array)

  • 김용범;김양한
    • 소음진동
    • /
    • 제11권1호
    • /
    • pp.57-67
    • /
    • 2001
  • Proposed in this paper is a method of measurement of the flow rate in a pipe. The sound waves which are propagated within a pipe are characterized by that the wavenumber in the axial direction is changed according to the flow rate, and these characteristics are used in the present method of measurement of the flow rate. The amount of change in wavenumber of sound waves according to the flow rate can be obtained from the relationship among acoustic pressure signals within a pipe, which are measured by using a microphone array. The flow rate can be obtained by using the amount of change in wavenumber of sound waves and the relational equation of the flow rate. With respect to errors that can occur during the measurement of the flow rate, the types of errors and the method of correction of those errors are presented. This method of measurement of the flow rate has application limitation conditions due to the sensor interval, assumption of sound waves as plane waves, etc. The numerical simulation and experiments for measuring the flow rate of air in a pipe are performed in order to verify the applicability of this method of measurement of the flow rate. The experimental results are shown to be similar to those of the numerical simulation. And the flow rate measured is shown to be consistent with the actual value within 5% error bound.

  • PDF

저항과 클록 주파수 변동에 의한 문제를 감소시킨 풀 디지털 방식 정전용량 센싱 터치키 설계 (A Design of Full Digital Capacitive Sensing Touch Key Reducing The Effects Due to The Variations of Resistance and Clock Frequency)

  • 성광수
    • 조명전기설비학회논문지
    • /
    • 제23권4호
    • /
    • pp.39-46
    • /
    • 2009
  • 본 논문에서는 저항과 클록 주파수 변동에 의한 문제를 효과적으로 감소시킬 수 있는 풀 디지털 정전용량 방식의 터치키를 제안한다. 제안된 방식은 측정하고자 하는 정전용량 두 개와 두 정전용량 사이의 저항으로 구성되어 있으며, 각 정전용량과 저항의 지연을 각각 측정한 후 두 지연의 비를 구한다. 양자화 오차를 무시할 경우 두 지연의 비는 측정하고자 하는 두 정전용량의 비로 표시되어 저항 값과 클럭 주파수와 무관하다. 실험결과에서도 제안된 방법이 저항과 클록주파수에 의한 변동을 효과적으로 줄일 수 있음을 보였으며, 제안된 방법의 정전용량 해상도가 1.04[pF]여서 터치키로 사용될 수 있음을 보였다.

Color Compensation of an Underwater Imaging System Using Electromagnetic Wave Propagation

  • Inoue, Kotaro;Lee, Min-Chul;Kim, Cheol-Su;Cho, Myungjin
    • Journal of information and communication convergence engineering
    • /
    • 제14권3호
    • /
    • pp.200-206
    • /
    • 2016
  • Images can be obtained by collecting rays from objects. The characteristics of electromagnetic wave propagation depend on the medium. In particular, in an underwater imaging system, the interface between air and water must be considered. Further, reflection and transmission coefficients can be found by using electromagnetic theory. Because of the fact that the values of these coefficients differ according to the media, the recorded light intensities will change. A color image sensor has three different color channels. Therefore, the reflection and transmission coefficients have to be calculated individually. Thereafter, by using these coefficients, we can compensate for the color information of underwater objects. In this paper, we present a method to compensate for the color information of underwater objects by using electromagnetic wave propagation theory. To prove our method, we conducted optical experiments and evaluated the quality of the compensated image by a metric known as mean square error.

비전 시스템을 이용한 AGV의 차선인식 및 장애물 위치 검출에 관한 연구 (A Study on Detection of Lane and Situation of Obstacle for AGV using Vision System)

  • 이진우;이영진;이권순
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2000년도 추계학술대회논문집
    • /
    • pp.207-217
    • /
    • 2000
  • In this paper, we describe an image processing algorithm which is able to recognize the road lane. This algorithm performs to recognize the interrelation between AGV and the other vehicle. We experimented on AGV driving test with color CCD camera which is setup on the top of vehicle and acquires the digital signal. This paper is composed of two parts. One is image preprocessing part to measure the condition of the lane and vehicle. This finds the information of lines using RGB ratio cutting algorithm, the edge detection and Hough transform. The other obtains the situation of other vehicles using the image processing and viewport. At first, 2 dimension image information derived from vision sensor is interpreted to the 3 dimension information by the angle and position of the CCD camera. Through these processes, if vehicle knows the driving conditions which are angle, distance error and real position of other vehicles, we should calculate the reference steering angle.

  • PDF