• Title/Summary/Keyword: error in test

Search Result 3,687, Processing Time 0.043 seconds

Test Algorithm and Measurement of Housekeeping A/D Converter (하우스킵핑 A/D 변환기의 테스트 알고리즘과 측정)

  • 박용수;유흥균
    • Journal of the Semiconductor & Display Technology
    • /
    • v.3 no.4
    • /
    • pp.19-27
    • /
    • 2004
  • The characteristic evaluation of A/D converter is to measure the linearity of the converter. The evaluation of the linearity is to measure the DNL, INL, gain error and offset error in the various test parameters of A/D converter. Generally, DNL and INL are to be measured by the Histogram Test Algorithm in the DSP-based ATE environment. And gain error and offset error are to be measured by the calculation equation of the measuring algorithm. It is to propose the new Concurrent Histogram Test Algorithm for the test of the housekeeping A/D converter used in the CDMA cellular phone. Using the proposed method, it is to measure the DNL, INL, gain error and offset error concurrently and to show the measured results.

  • PDF

Modelling of IMU Error with Setteing Misalignment in Laboratory Test (실험실 시험 장착오차를 고려한 관성측정장치 오차 모델링)

  • Seong, Sang-Man;Lee, Dal-Ho;Lee, Jang-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.4
    • /
    • pp.428-433
    • /
    • 1999
  • The errors of IMU(Inertial Measurement Unit) can be divided into deterministic and random errors. Since the required accuracy of the IMU is very high, the errors must be compensated by using an accurate error mode. In this paper, we present a method to get a more accurate error model in a laboratory test. This was done by considering the setting misalignment in the laboratory test in the IMU error model. We considered here the IMU which consits of DTG(dynamically tuned gyroscope) and pendulum type accelerometer. First, it was shown that the estimation result from the model which does not contain the setting misalignment gives considerable estimation error at the validation test. Second, a new model considering the setting misalignment was derived. Finally, by validation test using the estimation results from new model the validity of it was proved.

  • PDF

Effects of Human Error on the Optimal Test Internal and Unavailability of the Safety System (안전계통의 이용불능도 및 최적시험주기에 미치는 인간실수의 영향)

  • Chung, Dae-Wook;Koo, Bon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.174-182
    • /
    • 1991
  • Effects of human error relevant to the periodic test are incorporated in the evaluations of the unavailability and optimal test interval of a safety system. Two types of possible human error with respect to the test and maintenance are considered. One is the possibility that a good safety system is inadvertently left in a bad state after test(Type A human error) and the other is the possibility that a bad safety system is undetected upon the test(Type B human error). An event tree model is developed for the steady-state unavailability of a safety system in order to determine the effects of human errors on the system unavailability and the optimal test interval. A reliability analysis of the Safety Injection System (SIS) was peformed to evaluate the effects of human error on the SIS unavailability. Results of various sensitivity analyses show that ; (1) the steady-state unavailability of the safety system increases as the probabilities of both types of human error increase and it is far more sensitive to Type A human error, (2) the optimal test interval increases slightly as the probability of Type A human error increases but it decreases as the probability of Type B human error increases, and (3) provided that the test interval of the safety injction pump is kept unchanged, the unavailability of SIS increases significantly as the probability of Type A human error increases but slightly as the probability of Type B human error increases. Therefore, to obtain the realistic result of reliability analysis, one should take shorter test interval (not optimal test interval) so that the unavailability of SIS can be maintained at the same level irrespective of human error. Since Type A human error during test & maintenance influeces greatly on the system unavailability, special efforts to reduce the possibility of Type A human error are essential in the course of test & maintenance.

  • PDF

IMU calibration technique and laboratory test (관성측정장치의 오차계수 식별기법 및 실험)

  • 성상만;이달호;이장규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.664-667
    • /
    • 1996
  • This paper presents the error parameter estimation technique for IMU(Inertial Measurement Unit) which is core sensor of INS(Inertial Navigation System) and verifies it via laboratory test. Firstly the error characteristic of gyroscope and accelerometer which is contained in IMU is examined and the error modelling is executed. The error of IMU can be divided into deterministic and random part, and the deterministic error can be divided into static and dynamic part. This paper consider the random part as constant. Secondly the error parameter estimation technique and following procedure for laboratory test is explained. Thirdly according to the test procedure the IMU test for static error is executed using 2-axis rate table and estimation result is presented with discussion about its validity.

  • PDF

Design of the Memory Error Test Module at a Device Driver of the Linux (리눅스 디바이스 드라이버 내의 메모리 오류 테스트 모듈 설계)

  • Jang, Seung-Ju
    • The KIPS Transactions:PartA
    • /
    • v.14A no.3 s.107
    • /
    • pp.185-190
    • /
    • 2007
  • The necessity of error test module is increasing as development of embedded Linux device driver. This paper proposes the basic concept of freed memory error test module in the Linux device driver and designs error test module. The USB device driver is designed for freed memory error test module. I insert the test code to verify the USB device driver. I test the suggested error test module for the USB storage device driver. I experiment error test in this module.

Development of an NC Machine Performance Test and Calibration System (수치제어 공작기계의 위치오차 측정 및 보정시스템 개발)

  • 이상윤;박준호;조선휘;김문상
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1431-1440
    • /
    • 1993
  • This paper presents a new NC machine performance test and calibration system. In order to measure NC machine erros in simpler, and less time-comsuming way, some indirect measuring systems such as circular disk system and double ball bar system have been developed instead of laser interferometer. But these indirect measuring systems have shown their limits in identifying each of NC machine error sources in absolute numerical value. Therefore, we developed an unique NC machine error measurement system which provides a simple measuring process like other conventional indirect methods and still can indentify each of NC machine error sources in absolute numerical value.

Numerical estimation of errors in drop angle during drop tests of IP-Type metallic transport containers for radioactive materials

  • Lim, Jongmin;Yang, Yun Young;Lee, Ju-chan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1878-1886
    • /
    • 2021
  • For industrial package (IP)-type transport containers for radioactive materials, a free drop test should be conducted under regulatory conditions. Owing to various uncertainties observed during the drop test, errors in drop angles inevitably occur. In IP-type metal transport containers in which the container directly impacts onto a rigid target without any shock absorbing materials, the error in the drop angle due to a slight misalignment makes a significant difference from the ideal drop. In particular, in a vertical drop, the error in the drop angle causes a strong secondary impact. In this paper, a numerical method is proposed to estimate the error in the drop angle occurring during the test. To determine this error, an optimization method accompanying a computational drop analysis is proposed, and a surrogate model is introduced to ensure calculation efficiency. Effectiveness of the proposed method is validated by performing the verification and comparison between the test and the analysis applied with the drop angle error.

Type I Error Rates and Power for Omnibus Tests of Repeated Measures Measn in the Split-Plot Design : F test, $\widetilde{\xi}$F test, and CIGA test

  • Kim, Hyunchul
    • Communications for Statistical Applications and Methods
    • /
    • v.4 no.1
    • /
    • pp.139-149
    • /
    • 1997
  • For split plot designs exact univariate F tests of the within-subjects main effect are based on the assumption of multisample sphericity. Type I error rates and power are reported for the F test and two tests designed for use when multisample sphericity is violated: the $\widetilde{\xi}$-adjusted test and the Corrected Improved General Approximation(CIGA) test.The results indicate that even though the F test and the $\widetilde{\xi}$-adjusted test have better power than the CIGA test in some conditions, the F test and the $\widetilde{\xi}$-adjusted test do not control Type I error rates when the design is unbalanced and the F test dose not have a good control of Type I error rates when sphericity assumption is severely violated.

  • PDF

A Study on the ACC Safety Evaluation Method Using Dual Cameras (듀얼카메라를 활용한 ACC 안전성 평가 방법에 관한 연구)

  • Kim, Bong-Ju;Lee, Seon-Bong
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.2
    • /
    • pp.57-69
    • /
    • 2022
  • Recently, as interest in self-driving cars has increased worldwide, research and development on the Advanced Driver Assist System is actively underway. Among them, the purpose of Adaptive Cruise Control (ACC) is to minimize the driver's driving fatigue through the control of the vehicle's longitudinal speed and relative distance. In this study, for the research of the ACC test in the real environment, the real-road test was conducted based on domestic-road test scenario proposed in preceding study, considering ISO 15622 test method. In this case, the distance measurement method using the dual camera was verified by comparing and analyzing the result of using the dual camera and the result of using the measurement equipment. As a result of the comparison, two results could be derived. First, the relative distance after stabilizing the ACC was compared. As a result of the comparison, it was found that the minimum error rate was 0.251% in the first test of scenario 8 and the maximum error rate was 4.202% in the third test of scenario 9. Second, the result of the same time was compared. As a result of the comparison, it was found that the minimum error rate was 0.000% in the second test of scenario 10 and the maximum error rate was 9.945% in the second test of scenario 1. However, the average error rate for all scenarios was within 3%. It was determined that the representative cause of the maximum error occurred in the dual camera installed in the test vehicle. There were problems such as shaking caused by road surface vibration and air resistance during driving, changes in ambient brightness, and the process of focusing the video. Accordingly, it was determined that the result of calculating the distance to the preceding vehicle in the image where the problem occurred was incorrect. In the development stage of ADAS such as ACC, it is judged that only dual cameras can reduce the cost burden according to the above derivation of test results.

Developement of Measuring System of Circular Motion Accuracy in Machining Center (머시닝 센터에서 원운동정도 측정시스템의 개발)

  • 김영석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.4 no.3
    • /
    • pp.58-66
    • /
    • 1995
  • It is very important to test motion accuracy and performance of NC machine tools as they affect that of all other machines machined by them in industry. In this paper, in has become possible to detect errors of linear displacement of radial direction for circular motion test using newly assembled magnetic type of linear scales so called Magnescale ball bar system, and to calculate time interval getting error motion data and revolution angle of circular motion in machining center using tick pulses come out from computer. And a set of error data gotten from test is expressed to a plot by computer treatment and to numerics of error motion by statistical treatment and results of test are compared with those of Renishaw ball bar system.

  • PDF