• Title/Summary/Keyword: error equation

Search Result 1,572, Processing Time 0.033 seconds

Respiratory air flow transducer calibration technique for forced vital capacity test (노력성 폐활량검사시 호흡기류센서의 보정기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Jang, Jong-Chan;Kim, Seong-Sik;Lee, Su-Ok;Jung, Jae-Kwan;Park, Kyung-Soon;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1082-1090
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is a very important diagnostic parameter obtained from the forced vital capacity(FVC) test. The expiratory flow rate increases during the short initial time period and may cause measurement error in PEF particularly due to non-ideal dynamic characteristic of the transducer. The present study evaluated the initial rise slope($S_r$) on the flow rate signal to compensate the transducer output data. The 26 standard signals recommended by the American Thoracic Society(ATS) were generated and flown through the velocity-type respiratory air flow transducer with simultaneously acquiring the transducer output signal. Most PEF and the corresponding output($N_{PEF}$) were well fitted into a quadratic equation with a high enough correlation coefficient of 0.9997. But only two(ATS#2 and 26) signals resulted significant deviation of $N_{PEF}$ with relative errors>10%. The relationship between the relative error in $N_{PEF}$ and $S_r$ was found to be linear, based on which $N_{PEF}$ data were compensated. As a result, the 99% confidence interval of PEF error was turned out to be approximately 2.5%, which was less than a quarter of the upper limit of 10% recommended by ATS. Therefore, the present compensation technique was proved to be very accurate, complying the international standards of ATS, which would be useful to calibrate respiratory air flow transducers.

The Effect of Geometric Factors When Measuring Standard Count for Radioactive Iodine Thyroid Uptake Rate (표준계수 측정 시 기하학적 요인이 방사성 요오드 갑상선 섭취율에 미치는 영향)

  • Oh, Joo Young;Kim, Jung Yul;Oh, Ki Baek;Oh, Shin Hyun;Kim, Jae Sam;Lee, Chang Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.53-61
    • /
    • 2013
  • Objectives: It is certain that Radioactive iodine thyroid uptake(RAIU) rate should be measured with the standard counts considering the thyroid gland depth in enlarged thyroid patients for the variation from geometric factors. The purpose of this paper is to consider the effects of geometric factors according to detector to source distance and the effective thyroid depth on RAIU rate with experiment test. Materials and Methods: I-131 370 kBq ($10{\mu}Ci$) point source was measured by Captus-3000 thyroid uptake system (Capintec, NJ, USA) with a change Detector-Source Distance from 20 cm to 30 cm at an interval of 1 cm. And we changed the Neck phantom surface-Source Depth in the phantom with 1 cm, 2 cm, 5 cm using the neck phantom in order to reproduce the effective thyroid depth. Results: Every experimental group follows power curve as inverse square curve ($$R2{\geq_-}0.915$$). The average count rates in the case not using a phantom and the every case applied the effective thyroid depth using a phantom was not identical each other. There was significant fluctuations upon the effective thyroid depths applied the effective thyroid depth above 1 cm in $364.4 keV{\pm}10%$ energy ROI (p<0.01). There was not significant difference between the count rates of 1 cm and 2 cm in $364.4keV{\pm}20%$ and $637.1keV{\pm}6.2%$ (p=0.354, p=0.397). In assumed RAIU rate from regression equation, $364.4keV{\pm}20%$ was lower difference than $364.4keV{\pm}10%$ as 6.42% and 5.09% per 1 cm. Every change of count rate upon depth appears decreased line on Linear Regression, but the case of $284.3keV{\pm}10%$ increased only. And also, The graphs of coefficient of variation upon depth increased as straight line on every experimental group. Conclusion: The result appears that application of $364.4keV{\pm}20%$ energy ROI is more suitable for reducing error from the effective thyroid depth. And also, we can estimate the error of 20 cm should be highly reduced than 30 cm for Inverse Square Law. Therefore, If there is not information of the thyroid depth, it is considered that the error from thyroid depth can reduce through set up energy ROIs for $364.4keV{\pm}20%$, and increase Detector-Source Distances.

  • PDF

Predicting the Progression of Chronic Renal Failure using Serum Creatinine factored for Height (소아 만성신부전의 진행 예측에 관한 연구)

  • Kim, Kyo-Sun;We, Harmon
    • Childhood Kidney Diseases
    • /
    • v.4 no.2
    • /
    • pp.144-153
    • /
    • 2000
  • Purpose : Effects to predict tile progression of chronic renal failure (CRF) in children, using mathematical models based on transformations of serum creatinine (Scr) concentration, have failed. Error may be introduced by age-related variations in creatinine production rate. Height (Ht) is a reliable reference for creatinine production in children. Thus, Scr, factored for Ht, could provide a more accurate predictive model. We examined this hypothesis. Methods : The progression of of was detected in 63 children who proceeded to end-stage renal disease. Derivatives of Scr, including 1/Scr, log Scr & Ht/Scr, were defined fir the period Scr was between 2 and 5 mg/dl. Regression equation were used to predict the time, in months, to Scr > 10 mg/dl. The prediction error (PE) was defined as the predicted time minus actual time for each Scr transformation. Result : The PE for Ht/Scr was lower than the PE for either 1/Scr or log Scr (median: -0.01, -2.0 & +10.6 mos respectively; P<0.0001). For children with congenital renal diseases, the PE for Ht/Scr was also lower than for the other two transformations (median: -1.2, -3.2 & +8.2 mos respectively; P<0.0001). However, the PEs for children with glomerular diseases was not as clearly different (median: +0.9, +0.5 & +9.9 respectively). In children < 13 yrs, PE for Ht/Scr was tile lowest, while in older children, 1/Scr provided the lowest PE but not significantly different from that for Ht/Scr. The logarithmic transformation tended to predict a slower progression of CRF than actually occurred. Conclusion : Scr, floored for Ht, appears to be a useful model to predict the rate of progression of CRF, particularly in the prepubertal child with congenital renal disease.

  • PDF

Adsorption Characteristics and Parameters of Acid Black and Quinoline Yellow by Activated Carbon (활성탄에 의한 Acid Black과 Quinoline Yellow의 흡착특성 및 파라미터)

  • Yi, Kyung Ho;Hwang, Eun Jin;Baek, Woo Seung;Lee, Jong-Jib;Dong, Jong-In
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.186-195
    • /
    • 2020
  • The isothermal adsorption, dynamic, and thermodynamic parameters of Acid black (AB) and Quinoline yellow (QY) adsorption by activated carbon were investigated using the initial concentration, contact time, temperature, and pH of the dyes as adsorption parameters. The adsorption equilibrium data fits the Freundlich isothermal adsorption model, and the calculated Freundlich separation factor values found that activated carbon can effectively remove AB and QY. Comparing the kinetic data showed that the pseudo second order model was within 10% error in the adsorption process. The intraparticle diffusion equation results were divided into two straight lines. Since the slope of the intraparticle diffusion line was smaller than the slope of the boundary layer diffusion line, it was confirmed that intraparticle diffusion was the rate-controlling step. The thermodynamic experiments indicated that the activation energies of AB and QY were 19.87 kJ mol-1 and 14.17 kJ mol-1, which corresponded with the physical adsorption process (5 ~ 40 kJ mol-1). The adsorption reaction was spontaneous because the free energy change in the adsorption of AB and QY by activated carbon was negative from 298 to 318 K. As the temperature increased, the free energy value decreased resulting in higher spontaneity. Adsorption of AB and QY by activated carbon showed the highest adsorption removal rate at pH 3 due to the effect of anions generated by dissociation. The adsorption mechanism was electrostatic attraction.

A study on the estimation of bubble size distribution using an acoustic inversion method (음향 역산법을 이용한 기포의 크기 분포 추정 연구)

  • Park, Cheolsoo;Jeong, So Won;Kim, Gun Do;Moon, Ilsung;Yim, Geuntae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.151-162
    • /
    • 2020
  • This paper presents an acoustic inversion method for estimating the bubble size distribution. The estimation error of the attenuation coefficient represented by a Fredholm integral equation of the first kind is defined as an objective function, and an optimal solution is found by applying the Levenberg-Marquardt (LM) method. In order to validate the effectiveness of the inversion method, numerical simulations using two types of bubble distribution are performed. In addition, a series of experiments are carried out in a water tank (1.0 m × 0.54 m × 0.6 m), using bubbles generated by three different generators. Images of the distributed bubbles are obtained by a high-speed camera, and the insertion losses of the bubble layer are measured using a source and a hydrophone. The image is post-processed to glance a distribution characteristics of each bubble generator. Finally, the size distribution of bubbles is estimated by applying the inversion method to the measured insertion loss. From the inversion results, it was observed that the number of bubbles increases exponentially as the bubble size decreases, and then increases again after the local peak at 70 ㎛ - 120 ㎛.

A Design for Realtime Monitoring System and Data Analysis Verification TA to Improve the Manufacturing Process Using HW-SW Integrated Framework (HW-SW 통합 프레임워크를 활용한 제조공정 개선을 위한 실시간 모니터링 시스템과 데이터 분석검증 TA설계)

  • Kim, Jae Chun;Jin, Seon A;Park, Young Hee;Noh, Seong Yeo;Lee, Hyun Dong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.9
    • /
    • pp.357-370
    • /
    • 2015
  • Massive data occurred in a manufacturing place is able to fulfill very important roll to improve the manufacturing process. Domestic manufacturing business has been making an multilateral effort to react the change of manufacturing circumstance, but it undergoes many difficulties due to technical weakness. Coatings is a type of paint. It protect products by forming a film layer on the products and assigns various properties to those. The research of coatings is one of the fields studied actively in the polymer industry. The importance of the coatings in various industries is more increased. However, the industry still performs a mixing process in dependence on operator's experiences. In this paper, we propose a design for realtime monitoring system and data analysis verification TA to improve the manufacturing process using HW-SW integrated framework. Analysis results from the proposed framework are able to improve the coatings formulation process by collecting more quantitative reference data for work and providing it to work place. In particular, the framework may reduce the deterioration and loss cost which are caused by absence of a standard data as a accurate formulation criteria. It also may suggest a counterplan regarding errors which can be occurred in the future by deriving a standard calibration equation from the analysis using R and Design of Experiments about an error data generated in the mixing step.

Optimization of LC-MS/MS for the Analysis of Sulfamethoxazole by using Response Surface Analysis (반응표면분석법을 이용한 설파메톡사졸의 액체크로마토그래프-텐덤형 질량분석 최적화)

  • Bae, Hyo-Kwan;Jung, Jin-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.9
    • /
    • pp.825-830
    • /
    • 2009
  • Pharmaceutical compounds enter the water environment through the diverse pathways. Because their concentration in the water environment was frequently detected in the level of ppt to ppb, the monitoring system should be optimized as much as possible for finding appropriate management policies and technical solutions. One Factor At a Time (OFAT) approach approximating the response with a single variable has been preferred for the optimization of LC-MS/MS operational conditions. However, it is common that variables in analytical instruments are interdependent. Therefore, the best condition could be found by using the statistical optimization method changing multiple variables at a time. In this research, response surface analysis (RSA) was applied to the LC-MS/MS analysis of emerging antibiotic compound, sulfamethoxazole, for the best sensitivity. In the screening test, fragmentation energy and collision voltage were selected as independent variables. They were changed simultaneously for the statistical optimization and a polynomial equation was fit to the data set. The correlation coefficient, $R^2$ valuerepresented 0.9947 and the error between the predicted and observed value showed only 3.41% at the random condition, fragmentation energy of 60 and collision voltage of 17 eV. Therefore, it was concluded that the model derived by RSA successfully predict the response. The optimal conditions identified by the model were fragmentation energy of 116.6 and collision voltage of 10.9 eV. This RSA can be extensively utilized for optimizing conditions of solid-phase extraction and liquid chromatography.

Analysis of Photoluminescence of Eu3+ in YOBr and Investigation of Critical Distance (YOBr:Eu3+ 형광체의 발광특성과 임계거리 연구)

  • Kim, Gyeong Hwa;Park, Jong Gyu;Park, Hui Dong;Han, Jeong Hwa
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.6
    • /
    • pp.570-576
    • /
    • 2001
  • The europium doped yttrium oxybromide phosphors were synthesized by solid-state reaction method. The YOBr: $Eu^{3+}$ phosphor showed a strong and narrow red emission band at 621 nm and maximum emission intensity obtained when 0.05 mol Eu ions were doped. The red emission of $Eu^{3+}$ originated from $^5D_0$ ${\rightarrow}$ $^7F_2$electric dipole transition. In order to investigate on photoluminescence behavior, several experimental skills and numerical fittings are conducted to the YOBr: $Eu^{3+}$ phosphor. The emission spectrum was measured in the UV range and then decay curve of $^5D_0$ ${\rightarrow}$ $^7F_j$transitions was examined. The energy interaction type of YOBr: $Eu^{3+}$ phosphor was dipole-dipole interaction. In addition to the calculating by critical concentration, the critical distance ($R_0$) was calculated by decay curve fitting parameter from Inokuti-Hirayamas equation, and spectral overlap method. The critical distance was 17.03, 10.51 and 7.18$\AA$ for those methods, respectively. As considering systematic error of measurements, these values are within the same order, so that the above fitting methods are plausible and recommendable.

  • PDF

APPLICATION STUDY OF CHEMOINFOMETRICAL NEAR-INFRARED SPECTROSCOPY IN PHARMACEUTICAL INDUSTRY

  • Otsuka, Makoto;Kato, Fumie;Matsuda, Yoshihisa
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2111-2111
    • /
    • 2001
  • A chemoinfometrical method for evaluating the quantitative determination of crystallinity one polymorphs based on fourie-transformed near-infrared (FT-NIR) spectroscopy was established. A direct comparison of the data with the ones collected from using the and compared with the conventional powder X-ray diffraction method was performed. [Method] The pPure a and g forms of indomethacin (IMC) were prepared by reportedusing published methods. Six kinds of standard samples obtained by physically mixing of a and g forms. After the powder X-ray diffraction profiles of samples have been measured, the intensity values were normalized to against the intensity of silicon powder as the as an external standard. The calibration curves for quantification of crystal content were based upon the total relative intensity of four diffraction peaks from of the form g crystal. FT-NIR spectra of six calibration sample sets were recorded 5 times with the NIR spectrometer (BRAN+LUEBBE). Chemoinfometric analysis was performed on the NIR spectral data sets by applying the principal component regression (PCR). [Results] The relation between the actual and predicted polymorphic contents of form g IMC measured using by the X-ray diffraction method shows a good straight linen linear relation., and it has slope of 0.023, an intercept of 0.131 and a correlation coefficient of 0.986. PCR analyses wereis was performed based on normalized NIR spectra sets offer standard samples of known content of IMC g form. IMC. A calibration equation was determined to minimize the root mean square error of the predictionthe prediction. Figure 1 shows a plot of the calibration data obtained by NIR method between the actual and predicted contents of form g IMC. The predicted values were reproducible and had a smaller standard deviation. Figure 2 shows that the plot for the predicted transformation rate (%) of form a IMC to form g as measured by X-ray diffractomeoy against to those as measured by NIR method. The plot has a slope of 1.296, an intercept of 1,109, and a correlation coefficient of 0.992. The line represents a satisfactory correlation between the two predicted values of form g IMC content. Thus NIR spectroscopy is an effective method for the evaluation to the pharmaceutical products of quantitative of polymorph.

  • PDF

Evaluation of Dry Matter Intake and Average Daily Gain Predicted by the Cornell Net Carbohydrate and Protein System in Crossbred Growing Bulls Kept in a Traditionally Confined Feeding System in China

  • Du, Jinping;Liang, Yi;Xin, Hangshu;Xue, Feng;Zhao, Jinshi;Ren, Liping;Meng, Qingxiang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.23 no.11
    • /
    • pp.1445-1454
    • /
    • 2010
  • Two separate animal trials were conducted to evaluate the coincidence of dry matter intake (DMI) and average daily gain (ADG) predicted by the Cornell Net Carbohydrate and Protein System (CNCPS) and observed actually in crossbred growing bulls kept in a traditionally confined feeding system in China. In Trial 1, 45 growing Simmental${\times}$Mongolia crossbred F1 bulls were assigned to three treatments (T1-3) with 15 animals in each treatment. Trial 2 was conducted with 60 Limousin${\times}$Fuzhou crossbred F2 bulls allocated to 4 treatments (t1-4). All of the animals were confined in individual stalls. DMI and ADG for each bull were measured as a mean of each treatment. All of the data about animals, environment, management and feeds required by the CNCPS model were collected, and model predictions were generated for animals on each treatment. Subsequently, model-predicted DMI and ADG were compared with the actually recorded results. In the three treatments in Trial 1, 93.3, 80.0 and 73.3% of points fell within the range from -0.4 to 0.4 kg/d for DMI mean bias; similarly, in the four treatments in Trial 2, about 86.7, 73.3, 73.3 and 80.0% of points fell within the same range. These results indicate that the CNCPS model can accurately predict DMI of crossbred bulls in the traditionally confined feeding system in China. There were no significant differences between predicted and observed ADG for T1 (p = 0.06) and T2 (p = 0.09) in Trial 1, and for t1 (p = 0.07), t2 (p = 0.14) and t4 (p = 0.83) in Trial 2. However, significant differences between predicted and observed ADG values were observed for T3 in Trial 1 (p<0.01) and for t3 in Trial 2 (p = 0.04). By regression analysis, a statistically different value of intercept from zero for the regression equation of DMI (p<0.01) or an identical value of ADG (p = 0.06) were obtained, whereas the slopes were significantly different (p<0.01) from unity for both DMI and ADG. Additionally, small root mean square error (RMSE) values were obtained for the unbiased estimator of the two variances (DMI and ADG). Thus, the present results indicated that the CNCPS model can give acceptable estimates of DMI and ADG of crossbred growing bulls kept in a traditionally confined feeding system in China.