• Title/Summary/Keyword: error distribution

Search Result 2,057, Processing Time 0.03 seconds

Study on the measuring system of power quality for transmission system (송전계통의 전기품질 측정 시스템에 관한 연구)

  • Kim, Yeoung-Noh;Shin, Bong-Il;Lee, Hee-Chul;Kwak, No-Hong;Jeon, Young-Soo;Park, Sang-Ho;Lee, Il-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.107-109
    • /
    • 2006
  • The additional matters appear to be considered in several aspects for building up power-quality measuring system of transmission system(high voltage system) compared to distribution system(middle or low voltage system). Like in distribution system, input signals are also received from PT and CT source of voltage and current respectively in transmission system and applied in accordance with a certain rate. In this case, very big error rate can be occurred according to the specification of the measuring system as the applying rate is bigger than in distribution system beyond comparison. In addition, when the abnormal signal occurred such as sag/swell, interruption, transient etc., power quality of other sites linked to the system also should be checked to find the accurate cause of the abnormal power-quality signals from the corresponding site. Accordingly, the accurate diagnosis on the condition of Power quality for the system depends on the way how the synchronization system is brought along for each site. This paper will suggest the solution for the most effective system building focused on how to solve the problem of the error rate and synchronization described in the above when building up the measuring system of power quality for transmission system.

  • PDF

Study on the measuring system of power quality for transmission system (송전계통의 전기품질 측정 시스템에 관한 연구)

  • Kim Yeoung-Noh;Shin Bong-Il;Lee Hee-Chul;Kwak No-Hong;Jeon Young-Soo;Park Sang-Ho;Lee Il-Moo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.432-434
    • /
    • 2006
  • The additional matters appear to be considered in several aspects for building up power-quality measuring system of transmission system(high voltage system) compared to distribution system(middle or low voltage system). Like in distribution system, input signals are also received from PT and CT source of voltage and current respectively in transmission system and applied in accordance with a certain rate. In this case, very big error rate can be occurred according to the specification of the measuring system as the applying rate is bigger than in distribution system beyond comparison. In addition, when the abnormal signal occurred such as sag/swell, interruption, transient etc., power quality of other sires linked to the system also should be checked to find the accurate cause of the abnormal power-quality signals from the corresponding. site. Accordingly, the accurate diagnosis on the condition of power quality for the system depends on the way how the synchronization system is brought along for each site. This paper will suggest the solution for the most effective system building focused on how to solve the problem of the error rate and synchronization described in the above when building up the measuring system of power quality for transmission system.

  • PDF

Evaluation of Absorbed Dose for the Right Lung and Surrounding Organs of the Computational Human Phantom in Brachytherapy by Monte Carlo Simulation (근접방사선치료 시 몬테카를로 전산모사를 이용한 인체전산팬텀의 우측 폐와 주변 장기 선량평가)

  • Lee, Jun-Seong;Kim, Yang-Soo;Kim, Min-Gul;Kim, Jung-Soo;Lee, Sun-Young
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.443-451
    • /
    • 2020
  • This study is to evaluate absorbed dose from right lung for brachytherapy and to estimate the effects of tissue heterogeneities on dose distribution for Iridium-192 source using Monte Carlo simulation. The study employed Geant4 code as Monte Carlo simulation to calculate the dosimetry parameters. The dose distribution of Iridium-192 source in solid water equivalent phantom including aluminium plate or steel plate inserted was calculated and compared with the measured dose by the ion chamber at various distances. And the simulation was used to evaluate the dose of gamma radiation absorbed in the lung organ and other organs around it. The dose distribution embedded in right lung was calculated due to the presence of heart, thymus, spine, stomach as well as left lung. The geometry of the human body was made up of adult male MIRD type of the computational human phantom. The dosimetric characteristics obtained for aluminium plate inserted were in good agreement with experimental results within 4%. The simulation results of steel plate inserted agreed well with a maximum difference 2.75%. Target organ considered to receive a dose of 100%, the surrounding organs were left the left lung of 3.93%, heart of 10.04%, thymus of 11.19%, spine of 12.64% and stomach of 0.95%. When the statistical error is performed for the computational human phantom, the statistical error of value is under 1%.

How to Set an Appropriate Scale of Traffic Analysis Zone for Estimating Travel Patterns of E-Scooter in Transporation Planning? (전동킥보드 통행분포모형 추정을 위한 적정 존단위 선정 연구)

  • Kyu hyuk Kim;Sang hoon Kim;Tai jin Song
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.3
    • /
    • pp.51-61
    • /
    • 2023
  • Travel demand estimation of E-Scooter is the start point of solving the regional demand-supply imbalance problem and plays pivotal role in a linked transportation system such as Mobility-as-a-Service (a.k.a. MaaS). Most focuses on developing trip generation model of shared E-Scooter but it is no study on selection of an appropriate zone scale when it comes to estimating travel demand of E-Scooter. This paper aimed for selecting an optimal TAZ scale for developing trip distribution model for shared E-Scooter. The TAZ scale candidates were selected in 250m, 500m, 750m, 1,000m square grid. The shared E-Scooter usage historical data were utilized for calculating trip distance and time, and then applying to developing gravity model. Mean Squared Error (MSE) is applied for the verification step to select the best suitable gravity model by TAZ scale. As a result, 250m of TAZ scale is the best for describing practical trip distribution of shared E-Scooter among the candidates.

An Improvement of Still Image Quality Based on Error Resilient Entropy Coding for Random Error over Wireless Communications (무선 통신상 임의 에러에 대한 에러내성 엔트로피 부호화에 기반한 정지영상의 화질 개선)

  • Kim Jeong-Sig;Lee Keun-Young
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.3 s.309
    • /
    • pp.9-16
    • /
    • 2006
  • Many image and video compression algorithms work by splitting the image into blocks and producing variable-length code bits for each block data. If variable-length code data are transmitted consecutively over error-prone channel without any error protection technique, the receiving decoder cannot decode the stream properly. So the standard image and video compression algorithms insert some redundant information into the stream to provide some protection against channel errors. One of redundancies is resynchronization marker, which enables the decoder to restart the decoding process from a known state in the event of transmission errors, but its usage should be restricted not to consume bandwidth too much. The Error Resilient Entropy Code(EREC) is well blown method which can regain synchronization without any redundant information. It can work with the overall prefix codes, which many image compression methods use. This paper proposes EREREC method to improve FEREC(Fast Error-Resilient Entropy Coding). It first calculates initial searching position according to bit lengths of consecutive blocks. Second, initial offset is decided using statistical distribution of long and short blocks, and initial offset can be adjusted to insure all offset sequence values can be used. The proposed EREREC algorithm can speed up the construction of FEREC slots, and can improve the compressed image quality in the event of transmission errors. The simulation result shows that the quality of transmitted image is enhanced about $0.3{\sim}3.5dB$ compared with the existing FEREC when random channel error happens.

Evaluation of Quality Improvement in Inpatient's Medication System through the Implementation of Unit Dose Drug Distribution System (Unit Dose Drug Distribution System의 도입을 통한 투약시스템의 질 향상 평가)

  • Lee, In Hyang;Lee, Soonsil;Lee, Byung Koo;Choi, Won Ja;Hong, Sung Sun
    • Quality Improvement in Health Care
    • /
    • v.8 no.1
    • /
    • pp.22-42
    • /
    • 2001
  • Background : A study comparing unit dose drug distribution system(UDS) versus traditional drug distribution system(TDS) was conducted in Seoul National University Hospital. The objectives of this study were to identify safer drug distribution system and to measure the efficiency of both systems in utilizing nursing and pharmacist's time. Methods : The study was designed to compare the data on medication errors, nursing time and pharmacists' time before and after implementation of the UDS in the internal medicine and otorhinolaryngology care units. The data on actual medications administered to patients were obtained by a disguised observer during the study period. The data collected were then compared with the physicians' orders to determine the rate of medication errors. In addition, using ten-minute interval work-sampling method nursing and pharmacists' time were measured. Results : About 6% of medications were administered incorrectly in the TDS, in comparison to 1.6% in the UDS. The rate of medication error decreased significantly in the UDS compared with the TDS. Mean times spent on medication-related activities by nurses were 34.1% in the TDS and 28.5% in the UDS. In the internal medicine care unit, nursing time associated with medications decreased significantly after the implementation of the UDS, but the reduction in medication-related nursing time in the otorhinolaryngology care unit was not significant. Pharmacist's medication-related work activities, increased from 2% in the TDS to 20% in the UDS. Pharmacist's time spent on therapy-related activities increased significantly. Conclusion : The rate of medication errors in the UDS decreased significantly compared with the TDS. Time spent on medication-related activities decreased for nurses while it increased for pharmacists. In summary, the UDS was estimated to be safer and to utilize of pharmacists' and nursing time more efficiently than the TDS.

  • PDF

A New Remeshing Technique of Tetrahedral Elements by Redistribution of Nodes in Subdomains and its Application to the Finite Element Analysis (영역별 절점 재분포를 통한 사면체 격자 재구성 방법 및 유한요소해석에의 적용)

  • Hong J.T.;Lee S.R.;Yang D.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.607-610
    • /
    • 2005
  • A remeshing algorithm using tetrahedral elements has been developed, which is adapted to the mesh density map constructed by a posteriori error estimation. In the finite element analyses of metal forging processes, numerical error increases as deformation proceeds due to severe distortion of elements. In order to reduce the numerical error, the desired mesh sizes in each region of the workpiece are calculated by a posteriori error estimation and the density map is constructed. Piecewise density functions are then constructed with the radial basis function in order to interpolate the discrete data of the density map. The sample mesh is constructed based on the point insertion technique which is adapted to the density function and the mesh size is controlled by moving and deleting nodes to obtain optimal distribution according to the mesh density function and the quality optimization function as well. After finishing the redistribution process of nodes, a tetrahedral mesh is constructed with the redistributed nodes, which is adapted to the density map and resulting in good mesh quality. A goodness and adaptability of the constructed mesh is verified with a testing measure. The proposed remeshing technique is applied to the finite element analyses of forging processes.

  • PDF

Segmental Analysis Trial of Volumetric Modulated Arc Therapy for Quality Assurance of Linear Accelerator

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Huh, Hyun Do;Kim, Seonghoon
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.128-138
    • /
    • 2019
  • Purpose: Segmental analysis of volumetric modulated arc therapy (VMAT) is not clinically used for compositional error source evaluation. Instead, dose verification is routinely used for plan-specific quality assurance (QA). While this approach identifies the resultant error, it does not specify which machine parameter was responsible for the error. In this research study, we adopted an approach for the segmental analysis of VMAT as a part of machine QA of linear accelerator (LINAC). Methods: Two portal dose QA plans were generated for VMAT QA: a) for full arc and b) for the arc, which was segmented in 12 subsegments. We investigated the multileaf collimator (MLC) position and dosimetric accuracy in the full and segmented arc delivery schemes. A MATLAB program was used to calculate the MLC position error from the data in the dynalog file. The Gamma passing rate (GPR) and the measured to planned dose difference (DD) in each pixel of the electronic portal imaging device was the measurement for dosimetric accuracy. The eclipse treatment planning system and a MATLAB program were used to calculate the dosimetric accuracy. Results: The maximum root-mean-square error of the MLC positions were <1 mm. The GPR was within the range of 98%-99.7% and was similar in both types of VMAT delivery. In general, the DD was <5 calibration units in both full arcs. A similar DD distribution was found for continuous arc and segmented arcs sums. Exceedingly high DD were not observed in any of the arc segment delivery schemes. The LINAC performance was acceptable regarding the execution of the VMAT QA plan. Conclusions: The segmental analysis proposed in this study is expected to be useful for the prediction of the delivery of the VMAT in relation to the gantry angle. We thus recommend the use of segmental analysis of VMAT as part of the regular QA.

A Study on Effect of Various Cooling Methods in Motion of High-Precision Ball Screw (고속 고정밀 볼 스크류 구동에 따른 강제 냉각방식의 효과에 관한 연구)

  • Kim, Su-Sang;Xu, Zhe-Zhu;Kim, Hyun-Koo;Lyu, Sung-Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.3
    • /
    • pp.254-259
    • /
    • 2013
  • Ball screw system is widely used as a precision mechanical linear actuator that translates rotational motion to linear motion for its high efficiency, great stiffness and long life. Recently, according to the requirements of high accuracy and stiffness, the pre-load on the ball screw which means of remove the backlash in the ball screw is usually used. Because of the preload which means the frictional resistance between the screw and nut, becomes a dominating heat source and it generates thermal deformation of ball screw which is the reason for low accuracy of the positioning decision. There are several methods to solve the problem that includes temperature control, thermal stable design and error compensation. In the past years, researchers focused on the error compensation technique for its ability to correct ball screw error effectively rather than the capabilities of careful machine design and manufacturing. Significant amounts of researches have been done to real-time error compensation. But in this paper, we developed a series of cooling methods to get thermal equilibrium in the ball screw system. So we find the optimum cooling type for improving positioning error which caused by thermal deformation in the ball screw system.

A Study on the Diversity Reception Performance of Spread Spectrum Signals in Interference and Fading Environments (간섭과 페이딩환경에서 스펙트럼 확산(SS) 통신 신호의 다이버시티 수신 특성에 관한 연구)

  • 강희조;이권현;조성준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.5
    • /
    • pp.901-911
    • /
    • 1994
  • The error performance of M-ary differential phase shift keying (MDPSK) through m-distribution fading channel in hybrid direct sequence/slow frequency hopped spread spectrum multiple access (DS/SFH-SSMA) systems has been evaluated, and also the error probability has been evaluate when adopting diversity technique and coding technique. From the results, we know that the error performance more deteriorates as depth of fading becomes deeper. In Rayleigh fading environment (m=1), increasing of the number of frequency hopping (q) reduces the effect of multiple access interference, because it decreases the probability a hit. When q is much larger than the number of user (K), the probability of error in high E/N region is dominated by the multipath interference while the multiple access interference is negligible. In lower E/N region, the probability of error is independent of q because the effect of gaussian noise becomes dominat.

  • PDF