• Title/Summary/Keyword: equivalent power

Search Result 1,750, Processing Time 0.028 seconds

A Study on Voltage Collapse Mechanism using Equivalent Mechanical Model

  • Kim, Do-Hyung;Ryu, Heon-Su;Lee, Jong-Gi;Moon, Young-Hyun
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.6-14
    • /
    • 2002
  • In this paper, an EMM(Equivalent Mechanical Model) Is developed to explain the voltage collapse mechanism by reflecting the effects of reactive powers. The proposed EMM exactly represents the voltage instability mechanism described by the system equations. By the use of the EMM model, the voltage collapse mechanism has been illustrated by showing the exactness of the results. The stable region has been investigated with a reactive-power-controlled two-bus system, which shows that special alerts are required when the system operates with leading power factor. It is also discussed a system transform technique to eliminate the resistance component of the Thevenin equivalent impedance for practical applications. Finally, the results adopting the proposed method fur sample systems which were transformed are listed

Control Strategy Based on Equivalent Fundamental and Odd Harmonic Resonators for Single-Phase DVRs

  • Teng, Guofei;Xiao, Guochun;Hu, Leilei;Lu, Yong;Kafle, Yuba Raj
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.654-663
    • /
    • 2012
  • In this paper, a digital control strategy based on equivalent fundamental and odd harmonic resonators is proposed for single-phase DVRs. By using a delay block, which can be equivalent to a bank of resonators, it rejects the fundamental and odd harmonic disturbances effectively. The structure of the single closed-loop control system consists of a delay block, a proportional gain and a set of zero phase notch filters. The principle of the controller design is discussed in detail to ensure the stability of the system. Both the supply voltage and the load current feedforwards are used to improve the response speed and the ability to eliminate disturbances. The proposed controller is simple in terms of its structure and implementation. It has good performances in harmonic compensation and dynamic response. Experimental results from a 2kW DVR prototype confirm the validity of the design procedure and the effectiveness of the control strategy.

Modeling and Analysis of Three Phase PWM Converter (3상 PWM 컨버터의 모델링 및 해석)

  • 조국춘;박채운;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.328-335
    • /
    • 1999
  • Three phase full bridge rectifier has been used to obtain dc voltage from three phase ac voltage source. The rectifier system has drawbacks that power factor is low and power flow is unidirectional. Therefore, when dc voltage increases due to regeneration of power the dynamic resister for dissipation of regeneration power must be installed. But three phase PWM converter can be controlled to operate with unity power factor and bidirectional power flow. Therefore when the PWM converter is used as do supply system, the dissipating resistor is not necessary. On this thesis, in order to design a controller having good performance, the hee phase PWM converter is completely modeled by using circuit DQ-transformation and thus a general and simple instructive equivalent circuit is obtained; the inductor set becomes a second order gyrator-coupled system and three phase inverter becomes a transformer as well. Under given phase angle(${\alpha}$) and modulation index(MI) of the three phase inverter, the dc and ac characteristics are obtained by analysis of the transformed equivalent circuit The validity of the equivalent circuit is confirmed through PSPICE simulation. And based on the dc and ac characteristics a controller with unity power factor is proposed.

  • PDF

Accounting for the Atmospheric Stability in Wind Resource Variations and Its Impacts on the Power Generation by Concentric Equivalent Wind Speed (동심원 등가풍속을 이용한 대기안정도에 따른 풍력자원 변화에 관한 연구)

  • Ryu, Geon-Hwa;Kim, Dong-Hyeok;Lee, Hwa-Woon;Park, Soon-Young;Yoo, Jung-Woo;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.1
    • /
    • pp.49-61
    • /
    • 2016
  • The power production using hub height wind speed tends to be overestimated than actual power production. It is because the hub height wind speed cannot represent vertical wind shear and blade tip loss that aerodynamics characteristic on the wind turbine. The commercial CFD model WindSim is used to compare and analyze each power production. A classification of atmospheric stability is accomplished by Monin-Obukhov length. The concentric wind speed constantly represents low value than horizontal equivalent wind speed or hub height wind speed, and also relevant to power production. The difference between hub height wind speed and concentric equivalent wind speed is higher in nighttime than daytime. Under the strongly convective state, power production is lower than under the stable state, especially using the concentric equivalent wind speed. Using the concentric equivalent wind speed considering vertical wind shear and blade tip loss is well estimated to decide suitable area for constructing wind farm.

Analysis of Refractive Status between Urban and Rural Region in 13-year-old Children (도시와 농촌의 13세 어린이에 대한 굴절상태 분석)

  • Kim, Douk-Hoon;Kim, Jung-Sook
    • Journal of Korean Clinical Health Science
    • /
    • v.5 no.1
    • /
    • pp.808-815
    • /
    • 2017
  • Purpose. To analyze the refractive status between urban and rural regions, of children in Korea, in the age group of 13. Methods. From October 2016 to January 2017, forty subjects( 20 male subjects, 20 female subjects; 13 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+1.00D$, cylinder error ${\geq}0.75D$ and SE difference${\geq}1.00D$ between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 76.25%, astigmatism 35%, emmetropia 16.25%, anisometropia 8.75%, and hyperopia 5%. The prevalence of myopia and astigmatism were much more common in urban than rural region although the difference was not statically significant. Emmetropia and astigmatism were much more common in rural region than urban although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to -4.00 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between OD and OS of rural region in the spherical equivalent power(p<.000). Also, There was a statistical significance between OD and OS of urban region in the spherical equivalent power(p<.004). Therefore, there was a significant statistical similarity between urban and rural regions on the OD and OS in the spherical equivalent power. On the other hand, There was a significant statistical similarity between urban and rural regions of the OD and OS in the astigmatism power(p<0.000). However, in the rural and urban regions there was not statistical significance in the OD and OS concerning the spherical equivalent power and astigmatism power (p>0.1). Conclusions. Myopia was the most common refractive error in Korea young children. while hyperopia was few. There was not a statistical significance as age between rural and urban at spherical equivalent power( P> 0.01). These results suggested that the analysis of the refractive status at young children can give the useful diagnosis data for the correction of visual acuity.

Analysis of Refractive Error according to Aging in Young Children in South Korea (한국 어린이의 연령에 따른 굴절이상 분석)

  • Kim, Douk-Hoon;Kim, Dae-Nyoun
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose. to describe the prevalence of refractive error according to aging in young children in South Korea. Methods : From July 2013 to June 2014, five hundred subjects( 250 male subjects, 250 female subjects; aged between 7 and 12 years) were performed in refraction test using the Auto-Refraction. Myopia, hyperopia, astigmatism, and anisometropia were defined as spherical equivalent(SE)${\leq}-0.50$ diopters, SE ${\geq}+2.00$ D, cylinder error ${\geq}0.75$ D and SE difference${\geq}1.00$ D between binocular eyes, respectively. Results. The refractive error by spherical equivalent among all subjects was myopia 80.41%, astigmatism 44.89%, emmetropia 18.27%, anisometropia 16.92%, and hyperopia 1.32%. The prevalence of myopia increased with age. but hyperopia was decrease. Myopia and astigmatism were much more common in male than females although the difference was not statically significant. Emmetropia and hyperopia were much more common in female than males although the difference was not statically significant. The prevalence of spherical equivalent was much common from -1.00 diopter to 0.99 diopter. On the other hand, the prevalence of myopia was much more than hyperopia. There was a statistical significance between 9 year and 10 year of female in the spherical equivalent power(p>0.05). In all another group of age, there was not a statistical significance as aging in spherical equivalent power(p>0.5). However, there was a statistical significance between male and female as age in the spherical equivalent power(P>0.01). Conclusions: Myopia was the most common refractive error in Korea young children, while hyperopia was decreased after 7 years. There was a statistical significance as age between male and female at spherical equivalent power(P> 0.01). these results suggested that the analysis of the refractive error as age at young children can give the useful diagnosis data for the correction of visual function.

Review on Regulatory and Technical Standards of Radiation Protection for Lens of the Eye (수정체 방사선 방호에 관한 규제기준 및 기술기준 검토)

  • Si Young Kim;Seok-Ju Hwang;Jae Seong Kim;Jung-Kwon Son
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • The International Commission on Radiological Protection (ICRP) lowered the annual equivalent dose limit of lens of the eye for radiation workers from 150 to 20 mSv in April 2011. This trend of lowering the equivalent dose limit for radiation workers has been observed worldwide, including international organizations such as the International Atomic Energy Agency (IAEA), International Organization for Standardization (ISO) and the European Commission (EC). In 2016, the Nuclear Safety and Security Commission of South Korea published research results that included a proposal for lowering the equivalent dose limit of lens of the eye for radiation workers in line with the ICRP recommendation. However, as of now, South Korea's Nuclear Safety Act and related regulations still specify an annual equivalent dose limit of lens of the eye as 150 mSv for radiation workers. The IAEA and ISO have issued guidelines regarding radiation protection for lens of the eye and recommended a dose level for the lens of the eye at 5 or 6 mSv per year for periodic monitoring of the equivalent dose for the lens of the eye.

Study on the Analysis of Corneal Variation by Refractive Error (굴절이상에 의한 각막 변화도 분석에 관한 연구)

  • Lee, Hae-Jung;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.485-490
    • /
    • 2014
  • The purpose of this Study investigated corneal power, corneal astigmatism and corneal axis according to spherical equivalent of refractive error. We measured spherical equivalent, corneal power and corneal astigmatism in 100 subjects from January 2014 to July 2014. Measured spherical equivalent of refractive error were $-3.01{\pm}3.79D$, corneal power of $43.79{\pm}1.60D$ and corneal astigmatism of $-1.17{\pm}0.79D$ respectively. Prevalence of spherical equivalent of refractive error were as follows : myopes (61%), emmetropes (22%), hyperopes(17%). Corneal astigmatism of refractive error greater than +0.75D was 63% and prevalence of corneal astigmatism were as follows : with-the-rlue astigmatism (84.13%), against-the-rule astigmatism(9.52%) respectively. Corneal power by spherical equivalent increased from hyperopia to myopia. Between spherical equivalent of refractive error and the mean corneal power was significant correlation(r=-0.25, p=0.01). A correlation were found between corneal power and spherical equivalent of refractive error in adults. They have the highest distribution of prevalence myopia among the refractive error. When the refractive error was increased, we found that corneal power was steeper. It is recognized that this can be refractive error factor and correct visual function is considered.

High-Frequency Equivalent Circuit Model for Differential Mode Noise Analysis of DC-DC Buck Converter (DC-DC 벅 컨버터의 차동모드 노이즈 분석을 위한 고주파 등가회로 모델)

  • Shin, Juhyun;Kim, Woojung;Cha, Hanju
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.473-480
    • /
    • 2020
  • In this paper, we proposed a high frequency equivalent circuit considering parasitic impedance components for differential noise analysis on the input stage during DC-DC buck converter switching operation. Based on the proposed equivalent circuit model, we presented a method to measure parasitic impedance parameters included in DC bus plate, IGBT, and PCB track using the gain phase method of a network analyzer. In order to verify the validity of this model, a DC-DC prototype consisting of a buck converter, a signal analyzer, and a LISN device, and then resonance frequency was measured in the frequency range between 150 kHz and 30 MHz. The validity of the parasitic impedance measurement method and the proposed equivalent model is verified by deriving that the measured resonance frequency and the resonance frequency of the proposed high frequency equivalent model are the same.

Refractive Error in 7-9 Year-old Korea Children (7세부터 9세 사이의 한국인 어린이의 굴절 이상)

  • Kim, Douk-Hoon;Alberto, Mercedita O.
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.3
    • /
    • pp.203-208
    • /
    • 2014
  • Purpose. To analysis the refractive error in 7-9 year-old Korea children. Methods. From July 2013 to June 2014, two hundred eighty two subjects were performed in refraction test using the Auto-Refractometry. Results. The refractive error by spherical equivalent among all subjects was myopia 47.58%, emmetropia 42.35%, astigmatism 32.33%, and hyperopia 8.76%. Myopia was more common in female than males although the difference was not statically significant. The axis of astigmatism was with the rule in 65%, against the rule in 31.5%, and oblique in 3.5% There was a statistical significance between 7 year and 9 year of male in the spherical equivalent power(p=0.010). Also there was a statistical significance between 7 years and 9 years of female in the spherical equivalent power(p=0.036). However, there was not a statistical significance between male and female in spherical equivalent power(p>0.5). Conclusions. In this study, myopia was the most common refractive error. On the other hand, The prevalence of the axis of astigmatism was the with- the- rule. The spherical equivalent of refractive error was similar results between male and female. However The refractive error was different style with aging. these data suggested that the analysis of the refractive error at young children can provide the information of useful diagnosis for the correction of visual acuity.