• 제목/요약/키워드: equipment-based facility

검색결과 240건 처리시간 0.022초

건축 설비기기 소음의 특성 및 평가에 관한 연구 (A Study on the Evaluation and Characteristics of Architectural Facility-equipment Noise in Building)

  • 변운섭;최둘;김재수
    • 설비공학논문집
    • /
    • 제21권10호
    • /
    • pp.537-544
    • /
    • 2009
  • On account of the technological development, intelligent building is on increasing where the artificial regulation on indoor environment is possible, thence the concern about those facilities such as water-supply facility, water-heater and drainage facility has becomes higher. However, due to diversification and complicated system of the facility-equipments, the noise generating from such facility equipment is gradually becoming a problem, and since especially equipment noises arising at the machine room frequently infringe into the resident's pleasant living environment with the complex types of an air-borne sound and a structure-borne sound, it is becoming the civil complaint. On such viewpoint, this Study ever observed the characteristics of noise generating from various facility-equipments in the building, and intended to evaluate the facility-noises by use of the valuation index such as PSIL, N, NC, NR. As result of, the facilities noise which happens in the machine room makes normal conversation very difficult due to high sound pressure level. Based on such data, this study is willing to present it as an essential material for establishment an efficient measure against the facility-noises arising at machine room hereafter.

공공기관 연구시설장비 효율성 향상을 위한 온라인 일정계획 시스템 개발 (Developing an On-line Scheduling System for Increasing Effectiveness of Public Research Facility)

  • 이채윤;김기홍;신승준
    • 대한안전경영과학회지
    • /
    • 제19권1호
    • /
    • pp.181-189
    • /
    • 2017
  • The systematic management of technology infrastructure increasingly becomes critical as it represents the driving power for creating competitive advantage of nations and enterprises. In this sense, public facility and equipment, which is one major asset of technology infrastructure, should be managed effectively, systematically and efficiently to increase its overall equipment effectiveness. However, the manual and off-line communication was the unique way to communicate between the suppliers who provide facilities in the public sector and the customers who utilize the facilities in the industrial sector. This communication way caused invisibility of available usage time and increase of idle time, thereby decreasing the equipment effectiveness. This paper presents an web-based scheduling system that enables real-time collaboration and information sharing for increasing the equipment effectiveness. The designed system performs scheduling, facility management, order management and customer relationship management in an on-line platform, and carries out the processing and storing of relevant information in an integrated database. The paper includes a development approach to identify business process models and standardized system models by using object-modeling technique. The deliverable of the present work will contribute to increasing the equipment effectiveness by enhancing visibility, transparency and predictability by means of the integration with a legacy Enterprise Resource Planning.

설비 운영의 에러 분석을 통한 인자 및 모델연구 -반도체 산업중심- (The study on factor and model through error analysis to equipment operation (Focused on the Semiconductor industry))

  • 윤용구;박범
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2009년도 추계학술대회
    • /
    • pp.187-201
    • /
    • 2009
  • Semiconductor industry is based on equipment industry and timing industry. In particular, semiconductor process is very complex and as semiconductor-chip width tails and is becoming equipment gradually more as a high technology. Equipment operation is primarily engaged in semiconductor manufacturing (engineers and operator) of being conducted by, equipment errors have also been raised. Equipment operational data related to the error of korea occupational safety and health agency were based on data and production engineers involved in the operator's questionnaire was drawn through the error factor. Equipment operating in the error factor of 9 big item and 36 detail item detailed argument based on the errors down, and 9 big item the equipment during operation of the correlation error factor was conducted. Each of the significance level was correlated with the tabulation and analysis. Using the maximum correlation coefficient, the correlation between the error factors to derive the relationship between factors were analyzed. Facility operating with the analysis of error factors (big and detail item) derive a relationship between the model saw. The end of the operation of the facility in operation on the part of the two factors appeared as prevention. Safety aspects and ergonomics aspects of the approach should be guided to the conclusion.

  • PDF

Preliminary design of a production automation framework for a pyroprocessing facility

  • Shin, Moonsoo;Ryu, Dongseok;Han, Jonghui;Kim, Kiho;Son, Young-Jun
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.478-487
    • /
    • 2018
  • Pyroprocessing technology has been regarded as a promising solution for recycling spent fuel in nuclear power plants. The Korea Atomic Energy Research Institute has been studying the current status of equipment and facilities for pyroprocessing and found that existing facilities are manually operated; therefore, their applications have been limited to laboratory scale because of low productivity and safety concerns. To extend the pyroprocessing technology to a commercial scale, the facility, including all the processing equipment and the material-handling devices, should be enhanced in view of automation. In an automated pyroprocessing facility, a supervised control system is needed to handle and manage material flow and associated operations. This article provides a preliminary design of the supervising system for pyroprocessing. In particular, a manufacturing execution system intended for an automated pyroprocessing facility, named Pyroprocessing Execution System, is proposed, by which the overall production process is automated via systematic collaboration with a planning system and a control system. Moreover, a simulation-based prototype system is presented to illustrate the operability of the proposed Pyroprocessing Execution System, and a simulation study to demonstrate the interoperability of the material-handling equipment with processing equipment is also provided.

병원급식에 일반위생관리기준과 HACCP 제도 적용을 위한 시설모델 개발 (Development of a Hospital Foodservice Facility Plan and Model based on General Sanitation Standards and RACCP Guidelines)

  • 이정숙;곽동경;강영재
    • 한국식품조리과학회지
    • /
    • 제19권4호
    • /
    • pp.477-492
    • /
    • 2003
  • The purposes of the study were to establish HACCP-based standards and guidelines for conducting a plan review to build, or renovate, hospital food service establishments, and ensure the safety of foodservice and reduce the risk of food borne illness. The scope of the study included suggestion for the planning of hospital foodservice facilities: layout, design, equipment and modeling. The results of this study can be summarized as follows: 1) The development of a foodservice facility plan based on the results of a survey, literature reviews and the results of interviews with foodservice managers from 9 general hospitals. This was composed of operational policies in foodservices, layout characteristics, space allocation, selection, design, specification standards for equipment and the construction principles of foodservice facilities. 2) Two foodservice facility models were developed, one for general hospitals with 900 beds (2,000 patients and 2,500 employee meals per day) and the other for general hospitals with 300 beds (600 patients and 650 employees meals per day). 3) The suggested kitchen space requirements for the foodservice facility models were 341.2 ㎡ (W 17,100mm x L 23,700mm) and 998.8㎡ (W 35,600mm x L 32,800mm) for the 300 and 900 beds hospitals, respectively, with both designs being rectangular. The space requirements for the equipment, in relation to the total operational area, in terms of ratios were 1:3.5 and 1:3.8 for the 300 and 900 beds hospitals, respectively. The recommended space allowances per bed for the developed foodservice facility models were 1.15 ㎡ and 1.11 ㎡ for the 300 and 900 beds hospitals, respectively, which were increased by more than 30% compared to those suggested in the precedent study, and considered appropriate for the implementation of the HACCP system. 4) The hospital foodservice facilities plans and models were developed based on the general sanitation standards, guidelines and the HACCP system, and included foodservice facility layout, product flow, physical separation between contaminated and sanitary areas, foodservice facility specifications with a 1/300 scale for a 300 bed, and a 1/400 scale for a 900 beds blueprint. 5) The main features of the developed foodservice facility plans and models were; physical separation between contaminated and sanitary areas to prevent cross contamination, product flow in one direction from the arrival of the raw material to the finished product, and separation of different work areas and the process of receiving & preparation of products, refrigeration & storage, cooking, assembly, cleaning & disinfection, employee areas and janitorial facilities. The proposed models from this study were presented as examples for those wanting to build, or renovate, their facility for the production of foods.

터널 균열 검출에 활용되는 터널스캐너의 성능검증 방법론 (Performance Evaluation Method of Tunnel Scanner for Lining Crack Detection)

  • 배성재;정욱;짬릿 스레이와타나;김찬진;김영민;홍성호;김정곤;김정렬
    • 한국재난정보학회 논문집
    • /
    • 제17권1호
    • /
    • pp.39-52
    • /
    • 2021
  • 연구목적: 최근 시설물 점검 및 진단에 있어 활용되는 첨단장비들이 증가하여 첨단장비의 검·인증제도의 필요성이 대두되고 있다. 본 연구는 시설물 점검 및 진단에 활용되는 터널스캐너의 성능검증 방법론을 제시하는 것을 목적으로 한다. 연구방법: 시설물 점검 및 진단에 활용되는 첨단장비의 성능검증 사례를 조사하고 전문가 자문회의를 통해 터널스캐너 성능검증 방법론을 제시하였다. 연구결과: 본 연구에서 제안하는 터널스캐너 성능검증 방법론은 1차 평가와 2차 평가로 구성된다. 1차 평가지표는 최소요구성능을 기준으로 구성되고, 2차 평가지표는 터널스캐너의 품질에 관여된 지표들로 구성된다. 결론: 본 연구에서 제시한 터널스캐너의 성능검증 방법론은 장비 사용자에게 공인된 성능 카탈로그를 제공할 수 있으며, 장비 개발자는 장비의 공인된 검증을 받을 수 있어 부실한 유지관리를 예방할 수 있을 것으로 기대된다.

하둡 기반의 통합설비 모니터링시스템 설계 및 구현 사례 연구 (Case Study of Design and Implementation for Hadoop-Based Integrated Facility Monitoring System)

  • 김상락;장길상;조지운
    • 대한산업공학회지
    • /
    • 제40권1호
    • /
    • pp.34-42
    • /
    • 2014
  • SCADA and DCS that have performed automatic control and monitoring activities increase the productivity of enterprise in industries. In such systems, although their performance had been improved, there are still many deficiencies in predictive maintenance which can foresee the risk of any kinds of accidents. Because the data acquisition systems of main facilities are being distributed throughout the whole plant and therefore, integration of data obtained from the systems is very difficult. Accordingly, techniques that acquire meaningful information from the gathered data through realtime analysis still need to be improved. This paper introduces a developed facility monitoring system which can predict equipment failure and diagnose facility status through big data analysis to improve equipment efficiency and prevent safety accidents.

GIS를 이용한 대학시설물 관리시스템 개발 - 경북대학교를 중심으로 - (Development of Campus Facility Management System using GIS - Focused on Kyungpook National University -)

  • 이승엽;임용호;최현상
    • 한국지리정보학회지
    • /
    • 제1권1호
    • /
    • pp.18-27
    • /
    • 1998
  • 본 연구는 GIS를 이용하여 대학시설물 관리시스템의 개발을 수행한 결과를 다룬 것으로 시설물 관리에 GIS를 적용했을때의 장, 단점과 시스템의 개발과정에 대해 설명하고자 한다. 먼저, 시설물 관리란 사람들과 조직의 작업을 물리적인 작업공간과 하나로 통합하는 작업으로 볼 수 있다. 오늘날 시설물의 관리비용이 높아지고 합리적인 관리가 요구되기에, 이러한 조직들은 기존의 시설과 집기의 사용을 최대한 활용함으로써 더 이상의 불필요한 투자를 방지할 필요가 생겼다. 이러한 관점에서 본 연구의 목적은 GIS를 이용한 대학 시설물 관리 시스템 구축하는데 있다. 먼저 국립지리원의 1/5,000지도와 1/600의 측량도를 바탕으로 베이스 맵을 구축하고 제나시스의 제니어스 프로그램을 이용하여 학교내 각종 시설물관리 시스템을 개발하였다. 본 시스템은 지형정보관리, 지하매설물관리 그리고 시설물 관리의 3가지로 구분되며 각각의 속성정보를 이용함으로서 현재의 합리적인 관리뿐만 아니라 미래 지향적인 개발의 방향을 제시할 수 있다.

3D 모델링 기반 빌딩관제시스템의 설계 및 구현 (Design and Implementation of Building Control System based 3D Modeling)

  • 문상호;김병목;이계은
    • 한국멀티미디어학회논문지
    • /
    • 제23권5호
    • /
    • pp.673-682
    • /
    • 2020
  • Buildings are becoming more and more high-rise and large-scale in recent years, so in the event of a disaster such as a fire, enormous human and economic damage is expected. Therefore, management, security, and fire control are essential for large buildings in the city. Because these large buildings are very complex outside and inside, they need a three-dimensional control based on 3D modeling rather than a simple flat-oriented control. To do this, this paper designed and implemented a building control system based on 3D modeling. Specifically, we designed a 3D building / facility editing module for 3D modeling of buildings, a 3D based control module for building control, and a linkage module that connects information such as firefighting equipment, electrical equipment and IoT equipment. Based on this design, a building control system based on 3D modeling was implemented.

생물안전 3등급 연구시설의 구성 및 이용 (Composition and Use of Biosafety Level 3 Facility)

  • 김창환;허경행;이완걸;정성태
    • 한국군사과학기술학회지
    • /
    • 제18권3호
    • /
    • pp.335-342
    • /
    • 2015
  • Laboratory facilities for biology are designed as biosafety level 1, biosafety level 2, biosafety level 3, and biosafety level 4. Biosafety level designations are based on a composite of the design features, construction, containment facilities, equipment, practice and operation procedures required for working with agents from the various risk groups. Generally, biosafety level 3 means the facility that is appropriate for the experiments using pathogens which can cause serious diseases by aerosol transmission. The biosafety level assigned for the specific work to be done is driven by professional judgement based on a risk assessment, rather than by automatic assignment according to the particular risk group designation of the pathogenic agents to be used. In this paper, we introduced the biosafety level 3 facility operated in ADD(Agency for defense development). It contains the overview of facility, microbiological experiment, animal experiment, decontamination and waste disposal. Biosafety level 3 laboratory in ADD has served the vital role in the research of biological agents and antidote development.