• Title/Summary/Keyword: equipment safety performance

Search Result 566, Processing Time 0.028 seconds

Performance Based Design of Passive Fire Protection Using Consequence Analysis (사고 영향 분석을 이용한 성능위주의 내화설계)

  • Han, Dong-Hoon;Lee, Jong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.1
    • /
    • pp.102-107
    • /
    • 2004
  • Performance based design is a recent evolutionary step in the process of designing fire protection systems. In essence, it is a logical design process resulting in a solution that achieves a specified performance. Sometimes the prescriptive solutions presented in various codes and standards are too expensive or inflexible. Often the solutions do not and enables optimization of a solution for cost and function. In this study, performance based design was carried out to determine the extent of passive fire protection for oil terminal facilities. The results of performance based design were compared with those of prescriptive code based design. Performance based design is not always more economic than prescriptive code based design but provides more reliable and effective design that is fit for the purpose.

Validity Analysis of Scale Model Experiment for Wetting Agent Performance Evaluation (침윤소화약제 성능평가를 위한 축소실험의 타당성 분석)

  • Kim, Nam-Kyun;Lim, Kyung-Bum;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.14-19
    • /
    • 2014
  • A current standard exist only on the surface tension in the current domestic wetting agent technology standards, so it is difficult to the performance evaluation of the wetting agent through the standard. So this study presents the optimized performance evaluation methods by scale model experimental equipment in order to present techniques for performance evaluation of wetting agents. The purpose of this study is to investigate validity of experimental results of the self-designed scale model experiment equipment by a comparative analysis of experimental results of the NFPA 18 experiment and the experiment using the self-designed scale model experiment equipment. As a result of a comparative analysis of experimental results of the NFPA 18 experiment that evaluate only the permeation performance on the contton and the experiment using the self-designed scale model experiment equipment that evaluate the permeation performance and fire extinguishing performance on wood flour, the discrimination of the permeation performance was confirmed in both the NFPA 18 experiment and the self-designed scale model experiment equipment. And a result of self-designed experiment equipment have clear discriminatory more than NFPA 18 by internal temperature measurement using the thermocouples.

Performance Evaluation Method of Tunnel Scanner for Lining Crack Detection (터널 균열 검출에 활용되는 터널스캐너의 성능검증 방법론)

  • Bae, Sung-Jae;Jung, Wook;Chamrith, Sereivatana;Kim, Chan-Jin;Kim, Young-Min;Hong, Sung-Ho;Kim, Jung-Gon;Kim, Jung-Yeol
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.39-52
    • /
    • 2021
  • Purpose: Recently, due to increasing usage of high-tech equipment for facility inspection, the need of verifying high-tech equipment is being emphasized. Therefore, the purpose of this paper is to develop performance evaluation methodology of tunnel scanners that inspect tunnel facilities. Method: This paper describes literature reviews regarding the performance evaluation methodology of high-tech based equipment for facility inspection. Based on these investigations and expert advisory meetings, this paper suggests a performance evaluation methodology of tunnel scanner. Result: First evaluation indicator states minimum performance standards of tunnel scanners. Second evaluation indicator is related to tunnel scanner quality. Conclusion: The performance evaluation methodology can provide reliable equipment performance catalogues, helping users to make a proper selection of equipment. Also, developers of equipment can get authorized verification of performances, preventing poor maintenance of facilities.

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

A study on structural integrity and dynamic characteristic of inertial load test equipment for performance test of railway vehicle propulsion control system (철도차량 추진제어장치 성능시험을 위한 관성부하 시험설비의 구조안전성 및 동특성 평가 연구)

  • Jang, Hyung-Jin;Shin, Kwang-Bok;Lee, Sang-Hoon;Lee, Dae-Bong
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1389-1394
    • /
    • 2010
  • This paper describes the evaluation of structural integrity and dynamic characteristic of inertial load test equipments for performance test of railway vehicle propulsion control system. The propulsion control system of railway vehicle has to be confirmed of safety and reliability prior to it's application. Therefore, inertial load test equipments were designed through theoretical equation for performance test of propulsion control system. The structural analysis of inertial load test equipments was conducted using Ansys v11.0 and it's dynamic characteristic was evaluated the designed using Adams. The results showed that the structural integrity of inertial load test equipment was satisfied with a safety factor of 10.2. Also, the structural stability was proved by maximum dynamic displacement of 0.82mm.

  • PDF

The Study on Equipment Qualification of Emergency Diesel Generator Excitation Control System for Nuclear Power Plant (I) (원전 디젤발전기 여자시스템 기기검증시험에 관한 연구(I))

  • Lee, Joo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.143-145
    • /
    • 2007
  • The development of excitation control system (ECS) for emergency diesel generator in nuclear power plant is the replacement project of existing control system to resolve the maintenance problems caused by aging and obsolescence, The excitation control system is classified as a safety-related system. To guarantee the performance of developing excitation control system is equal to or higher than that of other systems, establishing the quality assurance scheme, doing software verification and validation activities, and planning equipment qualification. In this paper, we'd like to introduce the equipment qualification of excitation control system.

  • PDF

Development of Railway Platform Safety Equipment using Laser Radar Sensor (레이저 레이더 센서를 이용한 철도 승강장 안전설비의 개발)

  • Kim, Yoo-Ho;Hwang, Jong-Gyu;Jo, Hyun-Jeong;Baek, Jong-Hyun;Kim, Baek-Hyun;Ko, Tae-Kuk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.57-64
    • /
    • 2013
  • Many accidents are being occurred due to many missteps, etc. at the railway platform. Recently in Korea, efforts to prevent casualties fundamentally are being made by installing and operating the PSD(Platform Screen Door) with underground station building as its center to prevent these casualties of passengers. Although this PSD can solve the problem of public casualties at platform fundamentally, it is impossible to install it at whole station buildings since its installation cost is high, and in case of the ground station building of general railway whose operation speed is higher, installation of PSD is impossible due to the characteristics of railway system. This paper proposes the novel safety equipment using Laser radar sensors for the prevention against casualties of passengers at station buildings where the PSDs are not installed like this. The safety equipment using Laser radar sensors is the safety equipment making an approaching train stopped if the falling object is a person by detecting the obstacle at platform through, and it has the merit possible to apply it to station buildings not only in the underground section but also in the ground section since it may detect accurately under ambient environmental elements such as the snow, rain and yellow dust, etc. also. We developed the prototype of the safety equipment to reduce public casualties at platform by using Laser radar sensors and carried out its performance test, and the result is presented in this paper.

Development of Performance Test Equipment for Easy-Hill Assist Valve (EHA 밸브 성능시험 장치 개발)

  • Jung, G.H.
    • Journal of Drive and Control
    • /
    • v.11 no.4
    • /
    • pp.61-67
    • /
    • 2014
  • When a manual transmission equipped car stops on an incline where the nose of the car is higher than the rear, hill-start control or hill-holder could prevent the vehicle from rolling backward as the car moves forward. The easy-hill assist valve consists of a check valve and a needle type ON/OFF solenoid valve connected in parallel; it is a hydraulic actuator that can maintain brake pressure using an electrical signal from the ECU. As the EHA valve is a safety-related component of the brake system, high reliability as well as superior dynamic performance is required for it to be applied in commercial vehicles. This paper presents the design of the EHA valve as a piece of equipment that can simulate the brake actuation pressure with a pressurizing piston. Following specific test standards, the experimental results validate the implemented functions of the test equipment, proving the test stand to be effective for the performance and endurance of the EHA valve.

Characteristic Analysis and Implementation of 30kW Portable Test Equipment for Performance Evaluation in Energy Storage System (30kW급 ESS용 이동형 성능평가 시험장치의 구현 및 특성분석)

  • Park, Jea-Bum;Kim, Mi-Sung;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.715-723
    • /
    • 2018
  • The energy storage system consists of batteries, power conditioning system and energy management system. If ESS is installed and operated in the field, SAT(Site Acceptance Test) of ESS is being essentially required for the safety and performance of ESS. Furthermore, in order to more accurately and reliably validate the performance of the ESS in advanced countries, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool. Therefore, this paper proposes the modeling of portable test equipment in order to evaluate the performance and reliability of ESS by using the PSCAD/EMTDC S/W. And also, the prototype of 30[kW] scaled portable test equipments is implemented based on the S/W modeling. From the results of various simulations and testings such as power quality, LVRT and anti-islanding tests, it is confirmed that 30[kW] scaled portable test equipment is useful for SAT of ESS, because the simulation results of PSCAD/EMTDC are identical to them of 30[kW] test equipment at the same test conditions.

Importance-Performance Analysis (IPA) of Cyber Security Management: Focused on ECDIS User Experience

  • Park, Sangwon;Chang, Yeeun;Park, Youngsoo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.3
    • /
    • pp.429-438
    • /
    • 2021
  • The mandatory installation of the ECDIS (Electronic Chart Display and Information System) became an important navigational equipment for navigation officer. In addition, ECDIS is a key component of the ship's digitalization in conjunction with various navigational equipment. Meanwhile, cyber-attacks emerge as a new threat along with digitalization. Damage caused by cyber-attacks is also reported in the shipping sector, and IMO recommends that cybersecurity guidelines be developed and included in International Security Management (ISM). This study analyzed the cybersecurity hazards of ECDIS, where various navigational equipment are connected. To this end, Importance-Performance Analysis (IPA) was conducted on navigation officer using ECDIS. As a result, the development of technologies for cyber-attack detection and prevention should be priority. In addition, policies related to 'Hardware and Software upgrade', 'network access control', and 'data backup and recovery' were analyzed as contents to be maintained. This paper is significant in deriving risk factors from the perspective of ECDIS users and analyzing their priorities, and it is necessary to analyze various cyber-attacks that may occur on ships in the future.