• Title/Summary/Keyword: environmental standards

Search Result 1,990, Processing Time 0.032 seconds

A Study on Assessment Standard for Environmental Impact Assessment (한국에서의 환경영향평가 평가기준에 대한 연구)

  • Lee, Mu-Choon
    • Journal of Environmental Impact Assessment
    • /
    • v.2 no.2
    • /
    • pp.111-116
    • /
    • 1993
  • The EIA system was developed during ten odd years of introduction. On the other hand, the contentional development representing systematical fidelity does not match to it. I surveyed the problems of EIA on the point of environmental items with no legal standards. EIA is being executed only once on the planning stage. If the present EIA system has two times of execution, the quality of EIA will be much better. First, on the stage of deciding location of the project, EIA should be done. And next, detailed EIA should be done on the stage of executing the project. To describe the problems of EIA, I surveyed the legislations on the point of the former stages, investigation of present status and anticipation. And I tried a theoretical approach to EIA. The knowledge of things, the subject's standpoint and his valuation are all put together in the EIA. The knowledge of relationship between air and water pollutants and their impact on human is accumulated much. On the other hand, the knowledge of the compounded item, fauna-flora(natural ecology) is partial and causes many difficulties. I pointed out the absurdities of assessment technique dealing the standards and introduced assessment technique being applied to items with no physico-chemical standards such as wild lives.

  • PDF

Development of Patients Environmental Sustainability Performance in Healthcare Sector: A Conceptual Framework and Further Research Directions

  • KIM, Eunsung
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.99-109
    • /
    • 2019
  • Purpose - The purpose of this development the business model of the healthcare sector in order to promote patents satisfaction towards medical sector services improvement for the medical business model innovation to possess a competitive advantage in the medical and pharmaceutical industry. Research design, data, and methodology - Safety standard protocol from existing multidisciplinary literature is a process of theorization, which uses grounded theory methodology rather than a description of the data and the targeted phenomenon by using Jabareen (2009). The first task is to map the spectrum of food safety literature regarding the phenomenon in safety management. This process includes developing the implementation factors and other sources such as existing business models and practices into the protocol design. Results - The study suggests the conceptual framework to improve the safety management for patients' environmental sustainability performance. Conclusion - The business model may support the beneficial aspect to healthcare government's policymakers, hospital employees, and medical specialist who can apply the practical perspective of its value regarding an educational protocol. Originality/value - This study contributes to and extends our understanding of environmental sustainability performance, identifying the rationale for safety standards performance in the healthcare industry with suggested hybrid safety standards market consumer interconnector.

An Assessment Study for the Urban Air Monitoring Network in Seoul (서울지역 도시대기측정망 평가 연구)

  • Ghim, Young Sung;Choi, Yongjoo;Park, Ji Soo;Kim, Chan Hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.5
    • /
    • pp.504-509
    • /
    • 2014
  • Twenty-five stations of the urban monitoring network in Seoul were assessed with a focus on surveillance function of the exceedances of 8-hour ozone and 24-hour $PM_{10}$ standards. The two standards were selected because their attainment rates were particularly low. Two hierarchical cluster analyses were performed to group stations with similar atmospheric environments-one using daily highest 8-hour [$O_3+NO_2$], 8-hour $O_3$ concentrations plus corresponding 8-hour $NO_2$ concentrations considering the interconversion of $O_3$ and $NO_2$, and the other using 24-hour $PM_{10}$ concentrations. An index to measure higher concentration and exceedances of the standards was introduced. Within a cluster, sufficiently high score was assigned to the trends station or the station with higher index. Scores for $O_3+NO_2$ and $PM_{10}$ of a given station were added and ranked in the descending order to determine the relative importance.

Periodic Safety Review of Wolsong Unit 1 - Environmental Impact as gaseous and liquid effluents (월성 1호기 주기적안전성평가 - 기체 및 액체 방사성폐기물에 의한 환경영향)

  • 김성민;이은미;김미자;이갑복;정양근;엄희문
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.455-462
    • /
    • 2003
  • According to Korean nuclear code requires Periodic Safety Review(PSR) every 10 years should be perform for operating reactor, and selects the eleven PSR safety factors. Among them the review objective of the environmental impact is to determine whether the operator has an adequate programme for surveillance of the environmental impact of the nuclear power plant based on current safety standards. In this paper, the environmental impact in PSR of Wolsong Unit 1 was reflected current safety standards as of the evaluation date. As a result, all items generally satisfied the standards, and the staff also verified that the population dose due to the operation of Wolsong Unit 1 was controlled safely as of the evaluation date.

  • PDF

A Study on the Mock up Test for Reduction of HCHO Using the Functional Gypsum Board (기능성 석고보드의 폼알데히드(HCHO) 저감성능 평가를 위한 실물시험(Mock up test)연구)

  • Kim, Hea-Jeong;Song, Kyoo-Dong;Lee, Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.814-819
    • /
    • 2008
  • The purpose of this study was developing the building materials for creation the comfortable IAQ. By reducing formaldehyde(HCHO) known as the main factors of Sick House Syndrome. This material must be revealed the physical and eco-friendly performance, so this study set up the basic standards for building materials. The source of physical performance evaluation is Korea Industrial Standards and the base of environmental ability is the Eco Label considering certificated system related to an apartment house. Because the developed material was satisfied with the established standards, it was tested in mock-up room for obtaining the real date from indoor air. The mock-up test was conducted according environmental standard method for indoor air Quality of the ministry of environment. The result of this study were as follows; the functional building materials had a effect to reduce the formaldehyde concentration for a initial period without wall paper, so additional development is needed for application with the wall paper and the available period.

ENVIRONMENTAL NOISE POLICIES AND NOISE CONTROL PRACTICE IN CHINA

  • Tian, Jing
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.25-32
    • /
    • 2005
  • In China, environmental noise policies are composed of correlated laws adopted by the Standing Committee of the National People's Congress and promulgated by the President of the country, regulations promulgated by the State Council and/or local government, standards issued by the Standardization Administration Committee (SAC) under the State Council. The laws mainly include the 'Environmental Protection Law' and the 'Law on Prevention and Control of Pollution From Environmental Noise' Regulations are often applied to a special noise pollution phenomenon of wide influence. They are generally only effective in a given area and/or a specific period. Tens of correlated standards specify the noise level limits of different functional zones of land use and of different equipment, machines, devices, appliances etc., and the measurement methods. In this presentation, a brief introduction to these policies and their operations is given and discussed. The conclusion is that the policies supply an effective legislative basis for environmental noise prevention and control in China, but still a lot of work should be conducted and completed to strive for a quiet society.

  • PDF

The Studies of Biodegradabilities, Phosphates and Heavy Metals for Shampoos (샴푸중 계면활성제의 생분해도와 인산염 및 중금속 함유에 대한 연구)

  • 김영펄;김세경;임종완;유찬주;박선민
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.3
    • /
    • pp.136-141
    • /
    • 1997
  • The biodegradabilities of surfactants were measured for six kinds of shampoos in domestic market at present, and the phosphates and heavymetals are analyzed. Analysis results show that though they all come up to KS(Korean Industrial Standards), samples containing plenty of AOS and synthetic SLES have the lower biodegradability than the others. We knew the fact that thease smples are petroleum surfactants have the lower biodegradability than surfactants extracted naturally. All of them the contents of phosphates and heavymetals are excellent for limitation of the cosmetic standards.

  • PDF

Standardization Plan for Activation of Environmental Impact Assessment based on Spatial Information (공간정보 기반 환경영향평가 활성화를 위한 표준화 방안)

  • Jang, Jung-yoon;Cho, Namwook;Lee, Moung Jin
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.433-446
    • /
    • 2019
  • Environmental impact assessment has been performed as preliminary assessment system in order to conserve environment value and minimize negative effect from development. Assessment based on data has been necessary to strengthen objectivity in process of Environmental impact assessment process. Furthermore extended use of spatial information in Environmental impact assessment system has been required through spatial information provided at government level and possibility connected with spatial information in Environmental impact assessment. However spatial information has not been systematically utilized in current Environmental impact assessment. Also the environmental impact assessment workers including assessment government employees, agencies of Environmental impact assessment document and review agencies lack an understanding in the concept of spatial information, so there is limit about their use to efficiently. In order to improve these limits in use of spatial information, this study suggested measures to standardize spatial information (coordinate and attribute table). To do so, based on coordinate and standards certified by the government, this study defined standard coordinates (GRS-80, central datum point, False East: 100000, False North: 200000) and established 9 default items. Lastly, the aforementioned standards were tested for actual environmental impact assessment projects. Standardization measures suggested in this study are expected to contribute to invigorate spatial information utilization in Environmental impact assessment and expand the scope of the assessment.

The Estimation of Environmental Capacity in the Gamak Bay Using an Eco-hydrodynamic Model (생태계모델을 이용한 가막만 해역의 환경용량 산정)

  • Kang, Hoon;Kim, Jong-Gu
    • Journal of Environmental Science International
    • /
    • v.15 no.10
    • /
    • pp.951-960
    • /
    • 2006
  • The eco-hydrodynamic model was used to estimate the environmental capacity in Gamak Bay. It is composed of the three-dimensional hydrodynamic model for the simulation of water flow and ecosystem model for the simulation of phytoplankton. As the results of three-dimensional hydrodynamic simulation, the computed tidal currents are toward the inner part of bay through Yeosu Harbor and the southern mouth of the bay during the flood tide, and being in the opposite direction during the ebb tide. The computed residual currents were dominated southward flow at Yeosu Harbor and sea flow at mouth of bay, The comparison between the simulated and observed tidal ellipses at three station showed fairly good agreement. The distributions of COD in the Gamak bay were simulated and reproduced by an ecosystem model. The simulated results of COD were fairly good coincided with the observed values within relative error of 1.93%, correlation coefficient(r) of 0.88. In order to estimate the environmental capacity in Gamak bay, the simulations were performed by controlling quantitatively the pollution loads with an ecosystem model. In case the pollution loads including streams become 10 times as high as the present loads, the results showed the concentration of COD to be $1.33{\sim}4.74mg/{\ell}(mean\;2.28mg/{\ell})$, which is the third class criterion of Korean standards for marine water quality In case the pollution loads including streams become 30 times as high as the present loads, the results showed the concentration of COD to be $1.38{\sim}7.87mg/{\ell}(mean\;2.97mg/{\ell})$, which is the third class criterion of Korean standards for marine water quality. In case the pollution loads including streams become 50 times as high as the present loads, the results showed the concentration of COD to be $1.44{\sim}9.80mg/{\ell}(mean\;3.56mg/{\ell})$, which is the third class criterion of Korean standards for marine water quality.

Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures (오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구)

  • Park, Sun Hwan;Chang, Yoon Young;Jeong, Jeong Ho;Son, Jeong Ho;Park, Seok Hyo
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.2
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.