• 제목/요약/키워드: environmental flow

검색결과 5,199건 처리시간 0.028초

전기집진기 내부 유동 균일도 평가 기준인 ICAC EP-7과 %RMS 간 상관관계 (Relationship between ICAC EP-7 and %RMS, Standards for Gas Flow Uniformity inside Electrostatic Precipitators)

  • 신완호;홍원석;송동근
    • 한국대기환경학회지
    • /
    • 제26권2호
    • /
    • pp.234-240
    • /
    • 2010
  • Gas flow uniformity is an important factor to guarantee particle removal performance of electrostatic precipitators (EP), and the gas flow uniformity is evaluated by a fraction of standard deviation to the mean of gas flow distribution (%RMS) or a technical standard, ICAC EP-7, provided by The Institute of Clean Air Companies. In this study, relationship between the ICAC EP-7 and %RMS in evaluation of gas flow uniformity was investigated in terms of flow velocity. The maximum values of %RMS for gas velocity distribution of normal distribution has been obtained, and the maximum values of %RMS with gas velocity distribution satisfying ICAC EP-7 standards were also evaluated. With gas flow distribution obtained from CFD analysis and physical model test of real EP, %RMS values were calculated and it was tested if those gas flow distribution satisfy the criteria specified in ICAC EP-7. The %RMS values satisfying criteria of ICAC have been appeared to have similar values with %RMS values calculated with normal distribution of gas velocities.

온산 항만 시스템에서 조류와 수질 변화 시뮬레이션 (Simulation of Tidal Flow and Water Quality in Onsan Harbor System)

  • 김소연;박석순
    • 환경영향평가
    • /
    • 제8권3호
    • /
    • pp.13-22
    • /
    • 1999
  • Tidal flow and water quality were simulated in this paper to assess environmental impact caused by pier construction projects in Onsan harbor system. The Surfacewater Modeling System (SMS) was applied to the Onsan harbor system, where coastal reclamation and dredging were planned to build the piers. A finite element mesh was constructed and refined to cover the complicated geometry of the Onsan harbor and the proposed reclamation area. The time variable change of tidal height at harbor inlet was given as an input condition to tidal simulation. The water quality simulation was based on the discharge rate of suspended solids at the reclamation area. The simulation results have shown reasonable agreements with real situations in both tidal flow and water quality. According to the proposed plan, tidal flow and water quality were predicted during and after the pier construction. The tidal simulation study showed that there would be no discernible change of tidal current in the harbor except for the dredged area. The water quality simulation, however, predicted that suspended solids would increase significantly near the reclaimed and dredged areas during construction.

  • PDF

Large Scale Stabilized Finite Element Simulation and Modeling for Environmental Flows in Urban Area

  • Kashiyama Kazuo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.21-26
    • /
    • 2006
  • A large-scale finite element simulation and modeling method is presented for environmental flows in urban area. Parallel stabilized finite element method based on domain decomposition method is employed for the numerical simulation. Several GIS and CAD data are used for the preparation of the shape model for landform and urban structures. The present method Is applied to the simulation of flood flow and wind flow In urban area. The present method is shown to be a useful planning and design tool for the natural disasters and the change of environments in urban area.

  • PDF

Batch and Flow-Through Column Studies for Cr(VI) Sorption to Activated Carbon Fiber

  • Lee, In;Park, Jeong-Ann;Kang, Jin-Kyu;Kim, Jae-Hyun;Son, Jeong-Woo;Yi, In-Geol;Kim, Song-Bae
    • Environmental Engineering Research
    • /
    • 제19권2호
    • /
    • pp.157-163
    • /
    • 2014
  • The adsorption of Cr(VI) from aqueous solutions to activated carbon fiber (ACF) was investigated using both batch and flow-through column experiments. The batch experiments (adsorbent dose, 10 g/L; initial Cr(VI) concentration, 5-500 mg/L) showed that the maximum adsorption capacity of Cr(VI) to ACF was determined to 20.54 mg/g. The adsorption of Cr(VI) to ACF was sensitive to solution pH, decreasing from 9.09 to 0.66 mg/g with increasing pH from 2.6 to 9.9; the adsorption capacity was the highest at the highly acidic solution pHs. Kinetic model analysis showed that the Elovich model was the most suitable for describing the kinetic data among three (pseudo-first-order, pseudo-second-order, and Elovich) models. From the nonlinear regression analysis, the Elovich model parameter values were determined to be ${\alpha}$ = 162.65 mg/g/h and ${\beta}$ = 2.10 g/mg. Equilibrium isotherm model analysis demonstrated that among three (Langmuir, Freundlich, Redlich-Peterson) models, both Freundlich and Redlich-Peterson models were suitable for describing the equilibrium data. In the model analysis, the Redlich-Peterson model fit was superimposed on the Freundlich fit. The Freundlich model parameter values were determined to be $K_F$ = 0.52 L/g and 1/n = 0.56. The flow-through column experiments showed that the adsorption capacities of ACF in the given experimental conditions (column length, 10 cm; inner diameter, 1.5 cm; flow rate, 0.5 and 1.0 mL/min; influent Cr(VI) concentration, 10 mg/L) were in the range of 2.35-4.20 mg/g. This study demonstrated that activated carbon fiber was effective for the removal of Cr(VI) from aqueous solutions.

The Investigation of COD Treatment and Energy Consumption of Urban Wastewater by a Continuous Electrocoagulation System

  • DEDE SAGSOZ, Yesim;YILMAZ, Alper Erdem;EKMEKYAPAR TORUN, Fatma;KOCADAGISTAN, Beyhan;KUL, Sinan
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권2호
    • /
    • pp.261-268
    • /
    • 2022
  • In this study, electrochemical treatment of urban wastewater with electrical conductivity of 1000 μS cm-1 and chemical oxygen demand of 250 mg L-1 was investigated using the variables of initial pH value, current density and flow rate. Electrocoagulation was used, in which aluminum and stainless steel were selected, as the electrochemical treatment process. The electrocoagulation process was operated in continuous mode. The data obtained in experimental studies show that the best COD removal efficiency occurred in experiments where the initial pH value was 6. The increase in current density from 5 A to 15 A decreased the removal efficiency from 79 to 67%. The increase in flow rate under constant current density also reduced the efficiency of removal as expected. In experiments in which current density and flow rate were examined together, the increase in flow rate allowed the application of higher current densities. This situation led to considerable reductions in energy consumption values, even if the COD removal efficiency did not significantly increase. The high COD removal obtained with the use of high flow rate and high current density indicates that the electrocoagulation process can be used for high flow rate municipal wastewater treatment.

오염총량관리 유량측정자료를 이용한 낙동강 유역 유황분석 (Flow Duration Curve Analysis for Nakdong River Basin using TMDL Flow Data)

  • 김재철;김상단
    • 한국물환경학회지
    • /
    • 제23권3호
    • /
    • pp.332-338
    • /
    • 2007
  • In this study the flow duration curves for Nakdong river basin are analyzed. The TANK model is used as a hydrologic simulation model whose parameters are estimated from 8-day intervals flow data measured by NIER Nakdong River Water Environment Laboratory. As a comparison result between generated natural and present river flow, the present river flow is higher than the natural river flow in the up- and mid-stream of Nakdong river, while the present river flow is lower than the natural river flow in the down stream of Nakdong river.

탈질촉매 내 열화특성과 유동상태에 관한 연구 (A Study on Degradation Characteristic and Flow Behavior in De-NOx Catalyst)

  • 황승민
    • 한국환경과학회지
    • /
    • 제19권9호
    • /
    • pp.1093-1101
    • /
    • 2010
  • In this study, the indirect correlation of degradation characteristic and flow behavior in the de-NOx catalyst is investigated experimentally. The inner flow behavior in the de-NOx catalyst is varied from turbulent flow to laminar flow and the degradation of the de-NOx catalyst is remarkably affected by the inner flow. The degradation of the catalyst is increased in the upstream region near the inlet because injected turbulent flow enhances the adhesion of ash particle on the catalyst surface. The degradation of the catalyst near the inlet also governs the overall efficiency of the catalyst. The amount of adhered ash particles on the catalyst surface decreases as they progress downstream. This is due to the inner flow transition from turbulent flow to laminar flow.

우리나라 하천유역 환경변화가 유황특성에 미치는 영향 분석 (Analysis of Flow Duration Characteristics due to Environmental Change in Korea River Basin)

  • 이재준;김영준
    • 한국방재학회 논문집
    • /
    • 제11권1호
    • /
    • pp.67-75
    • /
    • 2011
  • 본 연구에서는 우리나라의 남해안 및 서해안으로 유입되는 주요 하천인 낙동강, 섬진강, 금강을 대상으로 다목적 댐 건설과 같은 하천환경의 변화가 하천의 상 중 하류부에 미치는 영향에 대하여 검토하기 위하여 비교적 수위자료와 수위-유량곡선 자료가 잘 구비되어 있으며, 자료의 보유년수, 관측개시일 등 양질의 자료가 축적되어 있는 지점을 대상으로 다목적 댐의 건설 시점을 기준으로 유황분석을 실시하였다. 유황의 변화를 분석한 결과 낙동강 중류부에 위치한 적포교 지점을 제외한 모든 지점에서 풍수량, 평수량, 저수량, 갈수량이 증가한 것으로 나타났으며, 하류부의 유황개선효과가 중 상류부에 비해 큰 것으로 나타났다. 하상계수와 유황계수 또한 감소된 것으로 나타났으나 유황계수의 감소폭은 하상계수에 비해 작게 나타났다. 이는 유황계수가 유량의 극치값에 대한 영향을 하상계수에 비해 작게 받기 때문인 것으로 사료되며, 본 연구를 통해서 중 상류부에 위치한 다목적 댐의 긍정적인 효과를 확인할 수 있을 것이라 판단된다.

수문학적 접근법에 의한 환경유량 산정기법의 적용성 평가 (The Applicability Assessment of Environmental Flows Method by Hydrological Approach)

  • 김주철;최용준
    • 한국물환경학회지
    • /
    • 제26권2호
    • /
    • pp.208-214
    • /
    • 2010
  • This study aimed at the introduction of desktop method for assessment of environmental flows developed by International Water Management Institute (IWMI) recently and its application to Geum river basin. This scheme simulated the influence on aquatic ecosystem caused by watershed development and in turn the decrease of water quantity keeping the river's own flow regime. It was found to be as very effective method although it had simple structure. Flow duration curves for different environmental classes at Sutong and Gongjoo sites were estimated according to the natural conditional scenario of Geum river basin and the results were relatively compared well with the previous studies. The behaviors of monthly average runoff time series of both sites showed the level of A class. The results of this study would provide the fundamental data to establish the future plans of monitoring or management for aquatic ecosystem of Geum river basin.

Three-dimensional modelling of water flow due to leakage from pressurized buried pipe

  • Zhu, Hong;Zhang, Limin;Chen, Chen;Chan, Kit
    • Geomechanics and Engineering
    • /
    • 제16권4호
    • /
    • pp.423-433
    • /
    • 2018
  • A three-dimensional model is constructed to simulate water infiltration in an unsaturated slope from a leaking pipe. Adaptive mesh refinement and time stepping are used, assisted by an automatic procedure for progressive steepening of the hydraulic property function for better convergence. The model is justified by comparing the simulated results with experimental data. Steady-state flow is investigated considering various pipe water pressures, locations and sizes of the opening, and soil layering. The opening size significantly affects the soaked zone around the pipe. Preferential flow dominates along the pipe longitudinal direction in the presence of a loose backfill around the pipe.