• 제목/요약/키워드: environmental fatigue analysis

Search Result 190, Processing Time 0.04 seconds

Multi-fidelity Data-fusion for Improving Strain accuracy using Optical Fiber Sensors (이종 광섬유 센서 데이터 융합을 통한 변형률 정확도 향상 기법)

  • Park, Young-Soo;Jin, Seung-Seop;Yoo, Chul-Hwan;Kim, Sungtae;Park, Young-Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.547-553
    • /
    • 2020
  • As aging infrastructures increase along with time, the efficient maintenance becomes more significant and accurate responses from the sensors are pre-requisite. Among various responses, strain is commonly used to detect damage such as crack and fatigue. Optical fiber sensor is one of the promising sensing techniques to measure strains with high-durability, immunity for electrical noise, long transmission distance. Fiber Bragg Grating (FBG) is a point sensor to measure the strain based on reflected signals from the grating, while Brillouin Optic Correlation Domain Analysis (BOCDA) is a distributed sensor to measure the strain along with the optical fiber based on scattering signals. Although the FBG provides the signal with high accuracy and reproducibility, the number of sensing points is limited. On the other hand, the BOCDA can measure a quasi-continuous strain along with the optical fiber. However, the measured signals from BOCDA have low accuracy and reproducibility. This paper proposed a multi-fidelity data-fusion method based on Gaussian Process Regression to improve the fidelity of the strain distribution by fusing the advantages of both systems. The proposed method was evaluated by laboratory test. The result shows that the proposed method is promising to improve the fidelity of the strain.

Comparative Study on the Bond Strength between Direct Tensile Test and Indirect Tensile Test for Bonded Concrete Overlay (직접인장 및 간접인장 실험방법에 따른 접착식 콘크리트 덧씌우기의 부착강도 비교 고찰)

  • Kim, Young Kyu;Lee, Seung Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1153-1163
    • /
    • 2013
  • Bonded concrete overlay is a favorable maintenance method since the material properties are similar to existing concrete pavements. In addition, bonded concrete overlay has advantage of structural performance based on being bonded together, both for the overlay layer and the existing pavement which perform as one monolithic layer. Therefore, it is important to have a suitable bond strength criteria for long term performance of bonded concrete overlay. This study aimed to investigate the affecting of bond strength on various bond characteristics, and to compare the bond strength between direct tensile test and indirect tensile test due to various conditions such as overlay materials, compressive and flexure strength of existing pavement, and deterioration status of existing pavement. As a result of this study, bond strength occurred by both of direct and indirect tensile test due to monotonic load is highly correlated such as coefficient of determination of 0.75 and P-value of 0.002. However, bond strength by indirect tensile test was relatively higher than bond strength by direct tensile test. It was known that correlation between direct and indirect tensile test was possible to use the characteristics analysis of bond fatigue behavior based on bond strength due to cyclic load which can simulate real field behavior of bonded concrete overlay.

A Study on Development of ECS for Severly Handicaped (중증 장애인을 위한 생활환경 제어장치개발에 관한 연구)

  • 임동철;이행세;홍석교;이일영
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.427-434
    • /
    • 2003
  • In this paper, we present a speech-based Environmental Control System(ECS) and its application. In the concrete, an ECS using the speech recognition and an portable wheelchair lift control system with the speech synthesis are developed through the simulation and the embodiment. The developed system apply to quadriplegic man and we evaluate the result of physical effect and of mental effect. Speech recognition system is constructed by real time modules using HMM model. For the clinical application of the device, we investigate the result applied to 54-years old quadriplegic man during a week through the questionnaires of Beck Depression Inventory and of Activity Pattern Indicator. Also the motor drive control system of potable wheelchair lift is implemented and the mechanical durability is tested by structural analysis. Speech recognition rate results in over 95% through the experiment. The result of the questionnaires shows higher satisfaction and lower nursing loads. In addition, the depression tendency of the subject were decreased. The potable wheelchair lift shows good fatigue life-cycle as the material supporting the upper wheelchair and shows the centroid mobility of safety. In this paper we present an example of ECS which consists of real-time speech recognition system and potable wheelchair lift. Also the experiments shows needs of the ECS for korean environments. This study will be the base of a commercial use.

Thickness Design of Composite Pavement for Heavy-Duty Roads Considering Cumulative Fatigue Damage in Roller-Compacted Concrete Base (롤러전압콘크리트 기층의 누적피로손상을 고려한 중하중 도로의 복합포장 두께 설계)

  • Kim, Kyoung Su;Kim, Young Kyu;Chhay, Lyhour;Lee, Seung Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.537-548
    • /
    • 2022
  • It is important to design the pavement thickness considering heavy-duty traffic loads, which can cause excessive stress and strain in the pavement. Port-rear roads and industrial roads have many problems due to early stress in pavement because these have a higher ratio of heavy loads than general roads such as national roads and expressways. Internationally, composite pavement has been widely applied in pavement designs in heavy-duty areas. Composite pavement is established as an economic pavement type that can increase the design life by nearly double compared to that of existing pavement while also decreasing maintenance and user costs. This study suggests a thickness design method for composite pavement using roller-compacted concrete as a base material to ensure long-term serviceability in heavy-duty areas such as port-rear roads and industrial roads. A three-dimensional finite element analysis was conducted to investigate the mechanical behavior and the long-term pavement performance ultimately to suggest a thickness design method that considers changes in the material properties of the roller-compacted concrete (RCC) base layer. In addition, this study presents a user-friendly catalog design method for RCC-base composite pavement considering the concept of linear damage accumulation for each container trailer depending on the season.

A Study on the Working Conditions of Agricultural Workers through a Comparison of Agricultural and General Workers: The 6th Korean Working Conditions Survey (농업군과 비농업군의 비교를 통한 농업취업자의 근로환경에 관한 연구: 제6차 근로환경조사 원시자료 이용)

  • Hyeseon, Chae;Sooin, Park;Insoo, Kim;Kyungran, Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.287-301
    • /
    • 2022
  • Objectives: This study compared the characteristics of the work environment between agricultural and general workers and analyzed the effects of agricultural working characteristics on work-related health problems. Methods: The participants of this study were 2,347 agricultural workers and 48,042 general workers who were selected by applying standardized weights to the raw data of 50,538 respondents from the 6th Korean Working Condition Survey (KWCS). Variables applicable to both worker groups and related to exposure to hazardous risk factors in the working environment, working hours and intensity of work, health problems and work-related status, and satisfaction with the work environment were selected. Chi-square tests and independent sample t-tests were performed to evaluate the differences in the variables between the two groups. Multivariate logistic regression analysis was conducted to analyze the effects of work environment characteristics on work-related health problems. Results: Compared to general workers, agricultural workers were more exposed to hazardous environments, irregular work patterns such as working on Saturday/Sunday, and short repetitive tasks. They reported more work-related and general health problems, including back pain, upper extremity muscle pain, lower extremity muscle pain, and general fatigue. Agricultural workers showed lower satisfaction with their work environment than general workers. Factors affecting one or more work-related health problems included gender, working years, hazardous factors, irregular work pattern, working hours, and labor intensity. Conclusions: Our findings showed that agricultural workers were relatively more vulnerable to safety issues compared to other occupational groups. Therefore, it is necessary to establish standardized safety and health standards and strengthen systematic safety and health management policies and services for agriculture.

Experimental Analysis of Large Size Concrete-Filled Glass Fiber Reinforced Composite Piles Subjected to the Flexural Compression (대구경 콘크리트 충전 복합소재 파일의 휨-압축 거동에 대한 실험적 분석)

  • Lee, Sung Woo;Choi, Sokhwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5A
    • /
    • pp.519-529
    • /
    • 2009
  • Fiber reinforced composite materials have various advantages in mechanical and chemical aspects. Not only high fatigue and chemical resistance, but also high specific strength and stiffness are attained, and therefore, damping characteristics are beneficial to marine piles. Since piles used for marine structures are subjected to compression and bending as well, detailed research is necessary. Current study examine the mechanical behavior under flexural and/or compressive loads using concrete filled fiber reinforced plastic composite piles, which include large size diameter. 25 pile specimens which have various size of diameters and lengths were fabricated using hand lay-up or filament winding method to see the effect of fabrication method. The inner diameters of test specimens ranged from 165 mm to 600 mm, and the lengths of test specimens ranged from 1,350 mm to 8,000 mm. The strengths of the fill-in concrete were 27 and 40 MPa. Fiber volumes used in circumferential and axial directions are varied in order to see the difference. For some tubes, spiral inner grooves were fabricated to reduce shear deformation between concrete and tube. It was observed that the piles made using filament winding method showed higher flexural stiffness than those made using hand lay-up. The flexural stiffness of piles decreases from the early loading stage, and this phenomenon does not disappear even when the inner spiral grooves were introduced. It means that the relative shear deformation between the concrete and tube wasn't able to be removed.

Shear Force Variation of Stiffening Girder caused by Vibration of Stay Cable (사장 케이블 진동에 의한 보강형의 전단력 변화)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.1-8
    • /
    • 2009
  • Stay cable is easily exposed to vibration induced rainy wind effects. There are some problems for not only unexpected vibration but also well-known vibration. An outbreak of displacement by the said effects brings damages such as over-tension of cables and barriers, fatigue of anchorages and dampers, and additional shear force variation of stiffening girders. This study suggests analytic methodology for dynamic tension variation of cables and shear force variation of stiffening girders. Additionally this study announces with dynamic problems for cable stayed bridge briefly. To realize this subject, we divide restoring force into chord component and normal component and then make up the differential equations which can satisfy physical phenomenon for each component. Finally we apply adequate functions such as sinusoidal and parabola in order to reduce these differential equations. Therefore we can meet with good results through a series of above process. As a remarkable result, CIP recommendations (2002) give inadequate solution with over 10% error. However it gives very good solution if parts of our study are reflected at the said recommendations. The fact means that CIP recommendations (2002) well-known as international standard of stay cables are not even concern about this subject yet. For verification of this study, F.E. analysis using E.C.C. with external forces was fulfilled, and the accuracy and conciseness of this study were shown.

Wave Analysis and Spectrum Estimation for the Optimal Design of the Wave Energy Converter in the Hupo Coastal Sea (파력발전장치 설계를 위한후포 연안의 파랑 분석 및 스펙트럼 추정)

  • Kweon, Hyuck-Min;Cho, Hongyeon;Jeong, Weon-Mu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.3
    • /
    • pp.147-153
    • /
    • 2013
  • There exist various types of the WEC (Wave Energy Converter), and among them, the point absorber is the most popularly investigated type. However, it is difficult to find examples of systematically measured data analysis for the design of the point absorber type of power buoy in the world. The study investigates the wave load acting on the point absorber type resonance power buoy wave energy extraction system proposed by Kweon et al. (2010). This study analyzes the time series spectra with respect to the three-year wave data (2002.05.01~2005.03.29) measured using the pressure type wave gage at the seaside of north breakwater of Hupo harbor located in the east coast of the Korean peninsula. From the analysis results, it could be deduced that monthly wave period and wave height variations were apparent and that monthly wave powers were unevenly distributed annually. The average wave steepness of the usual wave was 0.01, lower than that of the wind wave range of 0.02-0.04. The mode of the average wave period has the value of 5.31 sec, while mode of the wave height of the applicable period has the value of 0.29 m. The occurrence probability of the peak period is a bi-modal type, with a mode value between 4.47 sec and 6.78 sec. The design wave period can be selected from the above four values of 0.01, 5.31, 4.47, 6.78. About 95% of measured wave heights are below 1 m. Through this study, it was found that a resonance power buoy system is necessary in coastal areas with low wave energy and that the optimal design for overcoming the uneven monthly distribution of wave power is a major task in the development of a WEF (Wave Energy Farm). Finding it impossible to express the average spectrum of the usual wave in terms of the standard spectrum equation, this study proposes a new spectrum equation with three parameters, with which basic data for the prediction of the power production using wave power buoy and the fatigue analysis of the system can be given.

Study on Operating Strategy for Recreation Forests through Comparing the Level of User Satisfaction according to Clusters (군집별 만족도 비교를 통한 자연휴양림의 효율적 운영 방안 연구)

  • Gang, Kee-Rae;Lee, Kee-Cheol
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.1
    • /
    • pp.39-48
    • /
    • 2010
  • Recreation forests are in the spotlight as the place for personality development, mind and body comfort, companionship, and environment education in forests and valleys. Visitors to recreation forests have been on the increase along with booming in recreation forest building since 1988. Recreation forests are being categorized according to some features such as regional and environmental condition. Recreation forests, however, have not met the expectations of some visitors who want to take a rest with calmness due to the influence of the 5-day-work-week system, increasing interest in rest, leisure, and well-being, and users converge during weekends, summer, and the tourist season. In order to improve visitors' satisfaction efficiently, this study surveyed the level of satisfaction in each cluster based on the precedent study which had classified 85 national or public recreation forests in Korea into clusters. Questionnaires were distributed properly to each cluster and, of the 1,132 questionnaires collected, 1,015 were valid and used for analysis. Reliability of questionnaires and statistical validity of the model were verified. As a result, there are meaningful differences in the ranking of independent variables which affect the level of satisfaction according to clusters. Variables in rest and fatigue recovery have the strongest influence on the level of satisfaction in the clusters of potential factor, internal activation factor, and mixed potential capacity factor. In the use performance and visiting condition factor cluster, appropriateness of visit cost is most influential and, in the education cluster, connectivity with tourist attractions around it is most affective. These results can provide priority in services and maintenance of recreation forests for improving the level of satisfaction and differentiate the distribution of resources according to clusters.

The Psychological Relaxation Effects of College Students in Location Targeting Seonyudo Park in Autumn (가을철 선유도공원의 주제공간이 대학생들의 심리적 안정에 미치는 영향)

  • Yoon, Yong-Han;Oh, Deuk-Kyun;Kim, Jeong-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.2
    • /
    • pp.13-22
    • /
    • 2015
  • The study discovers mood state and enhancement effect of users by scenery of location targeting Seonyudo Park; where is widely recognized as the representative recycling environmental park as well as theme experience space and scenery admiration in Korea. Also, the influence level of park and thematic space upon wellness was researched for future park design and its base data. As a result of semantic differential(SD), the most items showed low point in positive way when people admiring the scenery in Seonyudo. Also, a subject experienced differently depending on each inside scenery element of the park. As a result of profile of mood states(POMS), a tension and anxiety points were shown in order of Urban (7.78) > Water Purification Basin(3.33) > Gardens of Water Plants(2.11) > Garden of Green Pillar(2.00) > Garden of Time (0.89). The depression points were shown in order of Urban(4.94) > Water Purification Basin(3.50) > Garden of Green Pillar(2.94) > Garden of Time(1.61) > Gardens of Water Plants(1.38). The anger and hostility points were shown in order of Urban(4.22) > Water Purification Basin(3.33) > Garden of Green Pillar(2.22) > Garden of Time(1.39) > Gardens of Water Plants(1.11). The fatigue points were shown in order of Urban(6.5) > Water Purification Basin(3.39) > Garden of Green Pillar(2.78) > Garden of Time(2.28) > Gardens of Water Plants (2.06). The vigor points were shown in order of Gardens of Water Plants(11.39) > Garden of Time(11.00) > Garden of Green Pillar(8.39) > Water Purification Basin(7.77) > Urban(5.28). Also, as a result of statistics analysis, difference value of scenery type is significant. The result of total emotional disturbance(TED) was analyzed in order of Urban(24.5) > Water Purification Basin(9.5) > Garden of Green Pillar(4.67) > Garden of Time(-1.39) > Gardens of Water Plants(-1.22).