• Title/Summary/Keyword: environmental durability

Search Result 836, Processing Time 0.026 seconds

Evaluation of Chloride Behavior and Service Life in Long-Term Aged FA Concrete through Probabilistic Analysis (장기재령 FA 콘크리트에 대한 염화물 거동 및 확률론적 염해 내구수명 평가)

  • Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.3
    • /
    • pp.276-285
    • /
    • 2020
  • In this study, accelerated chloride diffusion tests were performed on OPC(Ordinary Portland Cement) and FA(Fly Ash) concrete considering three levels o f W/B(Water to Binder) ratio o n 1,095 curing days. The accelerated chloride diffusion coefficient and the passed charge were evaluated in accordance with Tang's method and ASTM C 1202, and the resistance performance to chloride attack improved over time. FA concrete showed excellent resistance performance against chloride penetration with help of pozzolanic reaction. As the result of the passed charge, FA concrete showed durability improvement, "low" grade to "very low" grade, but OPC concrete changed "moderate" grade to "low" grade at 1,095 curing days. After assuming the design variables used for durability design as normal distribution functions, the service life of each case was evaluated by the probabilistic analysis method based on MCS(Monte Carlo Simulation). In FA concrete, the increase of probability of durability failure was lower than that of OPC concrete with increasing time, because the time-dependent coefficient of FA concrete was up to 3.2 times higher than OPC concrete. In addition, the service life by probabilistic analysis was evaluated lower than the service life by deterministic analysis, since the target probability of durability failure was set to 10%. It is considered that more economical durability design will be possible if the mo re suitable target probability of durability failure is set for various structures through researches on actual conditions and indoor tests under various circumstances.

Evaluation of Environmental Stability and Durability of Cementitious Mixed Soil (시멘트계 혼합토의 환경안정성 및 내구성 평가)

  • Oh, Sewook;Bae, Wooseok;Kim, Hongseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.9
    • /
    • pp.17-23
    • /
    • 2022
  • Using cement as a road subbase is economical, easily modified and supplemented and has excellent road pavement quality control. In addition, cement adheres well to sandy soils without adhesion, and it plays a role of permanently preserving adhesion in viscous soils with adhesion, so it can be widely applied as stable treatment with the advantages of increased strength, reduced compressibility. and improved durability. However, while cement is excellent in terms of strength for a road subbase, the material properties mean that it is difficult to maintain and reinforce when cracks or fractures occur due to dry shrinkage, and the pH increases in the ground due to hexavalent chromium eluting from cement. which can cause environmental problems such as groundwater contamination. Therefore, this study evaluates the usability of alternatives in the road base layer such as environmentally cementitious stabilizer and on-site soil generated from the site. We intend to reduce the environmental damage and evaluate the durability. To evaluate the applicability of the site, Environmental stability test and freeze-thaw test and wetting-drying test was conducted to evaluate the strength characteristics of alternative materials on the road through the limited performance evaluation of environmentally cementitious stabilizer. The test ranges were set at mixing ratios of 10%, 20%, and 30% and ages of three days, and 28 days old to evaluate the early strength and reference strength according to the mixing ratio of the environmentally cementitious stabilizer.

Secondary Mineral Formation and Concrete Deterioration Caused by Certain Environmental Conditions (특정환경조건하에서의 콘크리트 내 이차광물생성과 그에 수반된 성능저하현상)

  • 이효민;황진연;진치섭;이진성;전쌍순
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.651-656
    • /
    • 2003
  • Durability of concrete is possibly related to externally-induced chemical attacks in addition to internally-induced deterioration. Externally-induced chemical attacks can be derived from various sources according to environmental conditions under which concrete structures are existing. The present study investigates the characteristic concrete deterioration and formation of secondary minerals by external chemical attacks under certain environmental condition. Petrographic microscope, SEM, EDAX, XRD analyses were conducted to identify secondary mineral formation and micro-structural analyses.

  • PDF

Shear Cracking of Prestressed Girders with High Strength Concrete

  • Labib, Emad L.;Mo, Y.L.;Hsu, Thomas T.C.
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.1
    • /
    • pp.71-78
    • /
    • 2013
  • Prestressed concrete (PC) is the predominant material in highway bridge construction. The use of high-strength concrete has gained wide acceptance in the PC industry. The main target in the highway industry is to increase the durability and the life-span of bridges. Cracking of elements is one aspect which affects durability. Recently, nine 7.62 meter long PC I-beams made with different concrete strength were designed according to a simple, semi-empirical equation developed at the University of Houston (UH) (Laskar et al., ACI Journal 107(3): 330-339, 2010). The UH Method is a function of shear span-to-depth ratio (a/d), concrete strength $\sqrt{f^{\prime}_c}$, web area $b_wd$, and amount of transverse steel. Based on testing these girders, the shear cracking strength of girders with different concrete strength and different shear span-to-depth ratio was investigated and compared to the available approaches in current codes such as ACI 318-11 (2011) and AASHTO LRFD Specifications (2010).

Physical and Chemical Weathering Indices for Biotite Granite and Granitic Weathered Soil in Gyeongju

  • Ban, Jae-Doo;Moon, Seong-Woo;Lee, Seong-Won;Lee, Joo-Gong;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.451-462
    • /
    • 2017
  • Physical weathering caused by external forces and chemical weathering caused by the decomposition or alteration of constituent materials are the two factors that dominate the mechanical properties of rocks. In this study, a field investigation was undertaken to identify the physical and chemical weathering characteristics of the biotite granite and granitic weathered soils in Gyeongju, South Korea. Samples were collected according to their grade of weathering and subjected to modal analysis, XRD analysis, XRF analysis, physical property tests, particle size distribution tests, and slake durability tests. Modal and XRD analysis identified these rocks as biotite granite; secondary alteration minerals were not observed. Physical property tests and particle size distribution analyses indicate an average porosity of 41.28% and a sand content of > 90 wt.%. These values are somewhat higher than those of granites in general. The results of the slake durability test and XRF analyses show that the physical and chemical weathering indices of the samples vary with the degree of weathering.

The Research on Environmental-Friendly Manhole Repair and Construction Technology (친 환경적 맨홀 보수 및 시공 기술개발에 대한 연구)

  • Seo, Jeong-Hwan;Yang, Hae-Jeong;Kim, Kwang
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.836-841
    • /
    • 2012
  • The repair of road pavement and manhole has been resulted long construction times and traffic jams, environmental pollution from construction wastes, and budget waste due to excessive construction costs. In order to resolve such problems, we have developed the new construction method using C-ring, which can fix and raise the manhole securely. This technology is the method by driving in a wedge after inserting C-ring and expanding it in order to raise manhole to the regular height. This has been approved by the test reports of KOLAS(Korea Laboratory Accreditation Scheme), and was confirmed safety, durability and reliabilty in result. In this paper we approved this technology was able to short working times to around 20% and construction costs to around 50% with compare other construction methods. Also, environmental pollution and civil complaints will be prevented because there will be no longer any noises, vibrations, dust, or construction wastes.

Concrete properties prediction based on database

  • Chen, Bin;Mao, Qian;Gao, Jingquan;Hu, Zhaoyuan
    • Computers and Concrete
    • /
    • v.16 no.3
    • /
    • pp.343-356
    • /
    • 2015
  • 1078 sets of mixtures in total that include fly ash, slag, and/or silica fume have been collected for prediction on concrete properties. A new database platform (Compos) has been developed, by which the stepwise multiple linear regression (SMLR) and BP artificial neural networks (BP ANNs) programs have been applied respectively to identify correlations between the concrete properties (strength, workability, and durability) and the dosage and/or quality of raw materials'. The results showed obvious nonlinear relations so that forecasting by using nonlinear method has clearly higher accuracy than using linear method. The forecasting accuracy rises along with the increasing of age and the prediction on cubic compressive strength have the best results, because the minimum average relative error (MARE) for 60-day cubic compressive strength was less than 8%. The precision for forecasting of concrete workability takes the second place in which the MARE is less than 15%. Forecasting on concrete durability has the lowest accuracy as its MARE has even reached 30%. These conclusions have been certified in a ready-mixed concrete plant that the synthesized MARE of 7-day/28-day strength and initial slump is less than 8%. The parameters of BP ANNs and its conformation have been discussed as well in this study.

Growth Response and Durability of Landscape of Ornamental Miscanthus sinensis Cultivars to Drought, Rain Fall and Low Temperature Condition (건조, 강우, 저온 환경에서 관상용 억새 원예품종의 생장 반응과 경관의 지속성)

  • Ki-Dong Kim;Young-Sun Kim;Jeong-Ho Lee
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.4
    • /
    • pp.311-323
    • /
    • 2023
  • Miscanthus sinensis Andersson (Poaceae) cultivars exhibit excellent visual appeal as ornamental grasses and adapt well to diverse environmental conditions. This study focused on assessing the growth response and landscape durability of seven popular Miscanthus cultivars ('Gold Breeze', 'Strictus', 'Morning Light', 'Variegatus', 'Gracillimus', 'Kleine Fontäne', 'Common') under drought, rainfall and low temperature condition. The test cultivars were transplanted and cultivated on research plots in 2013, with data collected from June 2017 to February 2018. Plant materials were categorized into three types based on the amount of the water lost; group I ('Kleine Fontäne', 'Variegatus', 'Strictus'), experiencing the most significant water loss; group II ('Common', 'Gracillimus'); and group III ('Gold Breeze', 'Morning Light') where the least water loss occurred. The drought resistance index (DRI) remained low as water shortage conditions persisted. The lodged angle underwent more pronounced changes in reproductive growth stage than in vegetative growth stage, notably decreasing after heading. Discoloration patterns were classified into two types: group I ('Common', 'Gold Breeze', 'Kleine Fontäne', 'Strictus') and group II ('Gracillimus', 'Morning Light', 'Variegatus') based on the periods of peak duration.

Recommendations of Environmental Reduction Factor of FRP Rebar for Durability Design of Concrete Structure (콘크리트 보강용 FRP 보강근의 내구성 설계를 위한 환경영향계수의 제안)

  • Park Chan-Gi;Won Jong-Pil;Kang Joo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.529-539
    • /
    • 2004
  • The corrosion of steel rebars has been the major cause of reinforced concrete deterioration. FRP(Fiber-reinforced polymer) rebar has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. However, FRP rebar is prone to deteriorate due to other degradation mechanisms than those for steel. The high alkalinity of concrete, for instance, is a possible degradation source. Therefore, the USA, Japan, Canada, UK. etc are using environmental reduction factor. Although difference design guidelines were drawn in many, including USA, Japan, Canada, UK etc, recommendations and coefficients that could take into account the long-term behavior of FRP reinforcement were not well defined. This study focuses on recommendation of environmental reduction factor of FRP rebar. Environment reduction factor were decided using durability test result. FRP rebars were subjected to twelve type of exposure conditions including alkaline solution, acid solution, salt solution and deionized water etc. The water absorption behavior was observed by means of simple gravimetric measurements and durability properties were investigated by performing tensile, compressive and short beam tests. Based on the experimental result, environmental reduction factor of hybrid FRP rebar(A), and (C) and CFRP rebar was decided as 0.85. Also, hybrid FRP rebar(B) and GFRP rebar were decided as 0.7 for the environmental reduction factor

Research on Durability Assessment of Asbestos Stabilizer for Asbestos-containing Ceiling Materials (석면 함유 천장재에 대한 석면 안정화제 내구성 평가 연구)

  • Ha, Joo-Yeon;Shin, Hyun-Gyoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.18-27
    • /
    • 2020
  • Objectives: For testing asbestos stabilizer products which are used for the maintenance and management of asbestos-containing materials, durability assessment should accompany the evaluation of basic properties and performance. Therefore, in this study we designed a testing method and constructed a database of durability performance, thereby providing basic data for reliability studies of asbestos stabilizer. Methods: Since the ceiling materials targeted in this study are interior materials, test conditions of 95% relative humidity and 60℃ temperature were designed in consideration of the effect of high relative humidity in summer and seasonal indoor temperatures. Plate-shaped specimens treated with asbestos stabilizers were maintained in a thermo-hygrostat for 5, 10, and 20 days, and then the asbestos scattering prevention rate was measured by air erosion testing. Results: The scattering concentration tended to increase with time under the single humidity condition, and exceeded the indoor air quality standard of 0.01 f/cc, during the 20 days of maintenance. On the other hand, there was little change according to the temperature condition. In the case of a complex condition with temperature and humidity, the results were similar to the humidity test, but the scattering concentration increased more sharply at 20 days. Conclusions: The main deterioration factor that affects the durability of asbestos stabilizer is humidity, and the deterioration is caused by a mechanism in which the stabilizer coated on the surface is re-dissolved by moisture and evaporates or the coating layer is peeled off, which is accelerated by high temperatures.