• Title/Summary/Keyword: environmental cleaner

Search Result 146, Processing Time 0.025 seconds

Cleaner Production : Basic Principles And Development

  • Overcash, Michael
    • Clean Technology
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 1996
  • Cleaner production is of substantial importance in changing the environmental approach within advanced industrialized countries. The critical principles involve fundamental understanding of diverse industrial processes, adherence to the earliest techniques of a hierarchy for reducing wastes, and utilization of an underlying thought process to achieve pollution prevention successes that are both technically feasible and cost-effective. Chemical engineering has played a major and unique role in this environmental field. Improving the sustainability of cleaner production will rest on including this subject in the curriculum of university engineering.

  • PDF

The Flow Analysis for Vibration and Noise Diagnostic of Vacuum Cleaner Fan Motor (진공청소기 팬 모터의 진동 및 소음원인 분석을 위한 유동해석)

  • 김재열;곽이구;안재신;양동조;송경석;박기형
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.56-63
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

The Analysis of Vibration characteristics for Vacuum Cleaner Fan Motor Using 3-D Laser Vibrator (3차원 레이저 진동 측정기를 이용한 초고속 진공청소기 모터의 진동특성분석)

  • 김재열;김우진;심재기;김영석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.399-405
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000 rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

  • PDF

Development of Municipal Vehicle Safety System (환경미화원 산업재해방지를 위한 청소차량 안전시스템 개발에 대한 연구)

  • Lee, Man-Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.3
    • /
    • pp.57-61
    • /
    • 2009
  • Garbage cause an environmental pollution, unsightly mess, fouls an odor, and unpleasant feeling. Various measures to solve the problems are studying. And the garbage are collected and treated by the street cleaner. Street cleaner is working for long time in the street from dawn to the night. And many kind of accidents are aroused, like traffic and crushing accident by garbage truck. This kind of accidents is increased every year. To prevent the accident, street cleaner wear a fluorescent light uniform But a count measures for the fallen accident and crushing accident from the garbage truck are insufficient. In addition, a street cleaner dose not like to wear a working uniform because of inconvenience. Therefore this study try to find a safety system of garbage truck for reducing measure of accidents of street cleaner.

Field tests of indoor air cleaners for removal of PM2.5 and PM10 in elementary school's classrooms in Seoul, Korea (서울 초등학교 교실의 PM2.5 및 PM10 제거를 위한 학교용 공기청정기 실증)

  • Han, Bangwoo;Hong, Keejung;Shin, Dongho;Kim, Hakjoon;Kim, Yongjin;Kim, Sangbok;Kim, Sangwoo;Hwang, Cheongha;Noh, Kwangchul
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.79-90
    • /
    • 2019
  • It is important to control fine particles in children care centers, elementary schools, elderly care facilities and so on where vulnerable children and the aged stay during most of their time. This study has investigated $PM_{2.5}$ and $PM_{10}$ concentrations in two classrooms equipped with an air cleaner and two air cleaners, respectively and they were compared to those in a classroom without an air cleaner as well as those outdoors. Eight air cleaners which have various clean air delivery rates (CADRs) between 9.9 and $21.3m^3/min$ were tested in classrooms in two elementary schools in Seoul. Average $PM_{2.5}$ and $PM_{10}$ were $7.3{\pm}0.7$ and $45.5{\pm}4.1{\mu}g/m^3$ in classrooms equipped with an air cleaner and $4.2{\pm}0.6$ and $24.6{\pm}2.5{\mu}g/m^3$ in classrooms with two air cleaners, whereas they were $22.1{\pm}2.6$ and $109.1{\pm}9.6{\mu}g/m^3$ in classrooms without an air cleaner and $36.9{\pm}5.1$ and $74.1{\pm}10.6{\mu}g/m^3$ outdoors, respectively. $PM_{2.5}$ in classrooms could be reduced effectively by using an air cleaner or two air cleaners, because $PM_{2.5}$ was mainly infiltrated from outdoors, however $PM_{10}$ could not because $PM_{10}$ was mainly caused indoors by students' activities. Air cleaners were more effective for removal of $PM_{2.5}$ and $PM_{10}$ in classrooms with a high airtightness than those in classrooms with a relatively low one. Average $CO_2$ in classrooms was about 1500 to 2000 ppm for class hours dependent on the student number per a classroom, which was about 1.5 to 2 times higher than the standard, regardless of the use of air cleaner.

A study on the Behavior of Fine Particle used the HEPA Filer (HEPA Filter를 이용한 미세입자 거동에 관한 연구)

  • Kim, Won-Gang
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.3
    • /
    • pp.16-27
    • /
    • 2009
  • In this paper, I examined the level of fine dust in medical institutions, educational institutions and multi-purposed facilities to grasp the exact state of the present, and decided the level of air-borne particulate(KSM ISO Standard and ISO Standard 14644-1). We compared new proposed cleaner equipped with HEPA Filter with general cleaner and analyzed the rate of removal according to height, air volume and the equipment with the compulsive air intake. Through this comparison, I reached the conclusion as follows: 1. According to the examination, the fine dust of medical institutions, educational institutions and multi-purposed facilities in Kwang Ju is class 9. 2. The filter used in general cleaner on the market is that of HEPA-type, and its removal efficiency for fine particles($0.3{\sim}0.5{\mu}m$) is very low. 3. In the removal efficiency of new proposed cleaner equipped with HEPA Filter, the higher it is, the better, especially more than 180cm in height. 4. In case it is operated for 5 minutes under the condition of the space of $9.4m^{3}$ and the maximum air volume equipped with two induction pipes, we can keep the air cleanness level of 5 ~ 6. 5. To maintain the air cleanness for a long time, if we first operate for 5 minutes at maximum air volume and then operate at medium maximum air volume, we can keep the air cleanness with low energy.

Analysis on the Optimum Location of an Wet Air Cleaner in a Livestock House using CFD technology (전산유체역학 기법을 이용한 돈사 내 습식 공기 정화기의 적정 위치 설계)

  • Kwon, Kyeong-Seok;Lee, In-Bok;Hwang, Hyun-Seob;Bitog, Jessie.P.;Hong, Se-Woon;Seo, Il-Hwan;Choi, Ji-Sun;Song, Sang-Hyeon;Moon, Oun-Kyung
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.3
    • /
    • pp.19-29
    • /
    • 2010
  • In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.