Numerical analysis of Multi-Strand Anchor (하중분산 인장형 앵커의 수치해석)

  • Kim, Sung-Kyu;Kang, Byung-Chul;Kim, Nak-Kyung;Kim, Jeong-Ryeol
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.1243-1249
    • /
    • 2010
  • Ground anchors can be good solution in large and deep excavation. Anchored supports generally provide larger workspace than strut supports and good performances. The major benefit provided by these anchored systems was the open excavation area created by eliminating horizontal or raked struts, which generally inhibit rapid construction within the site area. In loose soils, however, anchors are sometimes hard to get high pullout anchor capacity, so that the spacing of anchor both horizontally and vertically is frequently controlled, in which the construction costs of anchors are increased. In order to increase anchor capacity, therefore, conceptual introduction of the multi-strand anchor is presented in this paper. Also, this study shows an numerical study of predicting the load transfer of the multi-strand anchor and a beam-column analysis was performed by a Elastic-Plastic beam theory.

  • PDF

Characteristics of Literature Related to Environmental Friendliness for a Village-focused Green Index (마을형 친환경지표 설정을 위한 친환경관련 문헌 조사 연구)

  • Byun, Kyeong-Hwa;Yoo, Chang-Geun
    • Journal of the Korean housing association
    • /
    • v.25 no.2
    • /
    • pp.79-87
    • /
    • 2014
  • The purpose of this study is to research the characteristics of literature related to environmentally friendly for a village-focused green index. In order to make an assessment, keywords relating to green architecture were selected: environmental friendliness, ecology, sustainable, Noksaek (Green in Korean), green, and environmentally friendly. In addition, three keywords defining the scope of space were also selected: building, village, and city. Quantitative changes and contents of articles containing the keywords were analyzed. The result is as follows. First, 'sustainable' and 'ecology' were the terms most frequently used as parts of subjects and titles, respectively. Second, the studies relating to green architecture focused on villages mostly examine the actual conditions of the villages; criteria for environmental friendliness, analyses and evaluation of the environmentally friendly features of the village; and ways to establish a green, ecological, and sustainable village. Finally, when it came to establishing a village-focused green index, the environment, resources, and energy are shown to be very important elements. In addition, the term 'ecology' in a green index is shown to be significant for the management of the natural environment.

Utilization of Building Colors with the Energy-Oriented Algae Façade System

  • Jo, Han-Sol;Han, Seung-Hoon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • Purpose: Building owners or residents have concerns to strive for energy-saving and environmental conservation by utilizing with eco-friendlier energy resources for their physical environment. In this paper, an algae façade system is proposed as an energy-friendly building component to improve energy productivity and indoor environmental quality, and this study aims at verifying alternative technologies for implementing building elevations that contain various colors equipped with algae façade systems and suggesting design guidelines to enhance both building performance and design values. Method: The color of algae is basically ranged about the saturation green, and it is hardly converted to other variations. Such a problem can be resolved through the artificial lights like LED (Light Emitting Diode) lamps to mix the color from the algae and buildings could possibly change the elevation in many ways under the influence of daylight. Result: As a result, the suggested system may increase the aesthetic aspect of the building in response to environmental changes. The system cannot possibly be applied for only new construction, but also it can be utilized with the existing buildings as well. The proposed system is expected to be applied not only a new construction and any existing buildings as well, and it will cover from the environmentally friendly energy generation in the industry to a new application system for increasing energy efficiency and the beauty of building envelopes.

A Study on the Sustainable Characteristics of the London City Hall (런던 시청사의 지속가능적 특성에 관한 연구)

  • Chung, Tae-Yong
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.5
    • /
    • pp.3-12
    • /
    • 2011
  • The purpose of this study is to analyze the sustainable characteristics of London city hall designed by Norman Foster. The most important part of sustainable architecture might be the energy reduction including minimizing CO$_2$ emission but social and economical aspects of sustainability should not be neglected. London City Hall as a successful example of sustainable architecture depends its success on the harmony of social, environmental and economical aspects of sustainability. Social sustainability in London City Hall appears on appropriateness and public good in the facility. London City Hall act as a symbol of redevelopment and civic community. Environmental sustainability of London City Hall summarized as using unique building form, double skin and underground water cooling system for the purpose of energy saving. Computer modeling technology was introduced to save construction cost for economic aspect of sustainability. Rational configuration of mechanical system strengthen the durability of facility. In case of London City Hall, the function of building, site condition and architectural concept fulfill the every aspects of sustainability in architecture. Besides these conditions, Foster applied sustainability to London City Hall as active and concrete design concept to complete its design goals.

Elastic Shear Buckling Strength of Steel Composite Box Girder Web Panel (강합성 박스거더 복부판의 탄성전단강도 연구)

  • Kim, Dae-Hyeok;Han, Sang-Yun;Kim, Jung-Hun;Kang, Young-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.3
    • /
    • pp.30-37
    • /
    • 2013
  • It is same such as the provision of shear buckling strength of steel composite box girder web panel and plate girder web panel in Korea Highway Bridge Design Standards(2012). But the web panel of steel composite box girder is different from the web of plate girder in that the upper slab and lower flange are connected to the web. So a different shear behavior of the girders is expected. In this study, To calculate a reasonable elastic shear buckling strength of steel composite box girder web panel, ABAQUS program was used. The results from F.E.A and previous studies are compared. It is shown that the web shear buckling strength of steel composite box girder of Korea Highway Bridge Design Standards(2012) is the most conservative.

Occupant Characteristics Analysis based on Integrative IEQ Weighting Factor in Residential Buildings - Based on Occupant Survey of Residential Building in Chungbuk Province (주거건물에서의 통합 실내환경평가 가중치 분석을 통한 거주자 특성분석 - 충북지역 주거건물 거주자 설문조사를 바탕으로)

  • Yoon, Sung-Hoon;Yun, Hee-Jin
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.87-92
    • /
    • 2016
  • Purpose: The objective of this research is to investigate and analyze the relationship between physical residential conditions and occupants' responses in apartment buildings by POE(Post-Occupancy Evaluation). The analysis results from this research will help to identify the indoor residential problems and find design solutions for improving overall residential indoor residential environment. Method: The occupant survey was conducted at four different apartment complex area at Cheongju City, Chungbuk Province, Korea. Combination of unbalanced indoor environmental conditions in residential building had difference of occupants' responses according to occupants' characteristics, such as gender, age, and so on. The survey collected data regarding the occupants' EQ(Environmental Quality) priorities to determine the weight of each environmental-quality factor (lighting, acoustic, thermal and indoor air quality). A paired comparison method was used to determine the weight by comparing the relative importance of the two factors based on occupant's survey response. Result: The output from this research is useful to understand the residential environment, occupants' satisfaction, preference, and identifies the current residential problems and finds an architectural solution in apartment buildings.

Influence of Perceived Neighborhood Walking Environment on Satisfaction for the Elderly (노인의 거주지 주변 보행환경 인식이 만족도에 미치는 영향)

  • Park, Young-Eun;Jung, Sung-Gwan;Lee, Woo-Sung
    • Journal of Environmental Science International
    • /
    • v.28 no.12
    • /
    • pp.1111-1121
    • /
    • 2019
  • The purpose of this study is to analyze the effect of perceived walking environment around neighborhood on satisfaction for old adults in Daegu. The study was conducted using 407 questionnaires were collected through the survey. The walking environment was categorized into accessibility to neighborhood walking facilities and walking environment around path. Regarding perception of walking accessibility, access to 'public transit stops' and to 'medical facilities' was relatively high. For walking environment, 'pavement condition', 'continuity of sidewalk', and 'slope of sidewalk' were rated relatively high. Multiple regression analysis after factor analysis of walking environment variables showed that religious and convenient facilities, park and leisure facilities, and medical and welfare facilities had a significant effect on satisfaction in walking accessibility. For walking environment the convenience for walking, safety for walking, and amenities for walking had a significant effect on satisfaction. The findings from this study can be used for improving the walking environment for old adults.

Air Temperature Change by Vegetation Canopy in Urban Park (도시 공원 내 식생 수관에 의한 기온 변화)

  • Lee, Sang-Hwa;Lee, Kyoo-Seock;Zheng, Hai-Yan;Jin, Wen-Cheng
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.1
    • /
    • pp.44-51
    • /
    • 2009
  • In order to determine air temperature difference by canopy layer in the forest, air temperatures were observed at Seolleung Park, Gahngnam-ku, Seoul. from November 9, 2007 to November 8, 2008 by 10 minute interval. The data were analyzed in terms of diurnal variation based on annual and monthly temperature difference. Using calm, less cloudy and no rainy weather data, average air temperature difference between forest and grass was observed as $0.8^{\circ}C$. The maximum air temperature difference was observed at 22:10, 23:20, 23:30 and 23:40 by $2.13^{\circ}C$ and the minimum one observed at 13:00 by $-0.84^{\circ}C$ in diurnal variation. The maximum temperature difference occurred at 19 : 50 on September by $3.67^{\circ}C$, Overall the air temperature in the forest was higher than that of grass at night and lower in midday.

A Scale-Effect of O-Cell Pile Load Test with Variable End Plate (가변선단재하판을 이용한 양방향말뚝재하시험의 치수 효과)

  • Joo, Yong-Sun;Kim, Nak-Kyung;Kim, Ung-Jin;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.884-890
    • /
    • 2009
  • The bi-directional pile load test with variable end plate overcomes the shortcoming of the Osterberg cell test. It is possible that the ultimate bearing capacity of the bi-direction can be known by using the loading of the end plate and two step procedures. The first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell, operated with end plate of 3 type on sand layer according to the relative density, loose, medium and dense conditions.

  • PDF

Numerical Analyses of O-Cell Load Test on Pile (양방향말뚝재하시험의 수치해석)

  • Joo, Yong-Sun;Kim, Nak-Kyoung;Kim, Woong-Jin;Park, Jong-Sik
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.748-753
    • /
    • 2008
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurisation causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. Bi-directional load tests using O-cell are now becoming common practice around the world, particularly where the loads to be applied are high or where it is not convenient to perform top-down loading tests. In the study, calculate ultimate capacity of bi-directional load test using FEM and beam on elasto-plastic foundation theory.

  • PDF