• 제목/요약/키워드: environment of pipe

검색결과 516건 처리시간 0.027초

Numerical Study on the formation of an injectable barrier in the subsurface

  • 김미정;박주양
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 총회 및 춘계학술발표회
    • /
    • pp.98-101
    • /
    • 2002
  • Numerical experiments were performed to investigate horizontal barrier formation in unsaturated soils by permeation grouting through multiple vertical injection pipes. The results were compared with the horizontal barrier formation achieved by using multiple horizontal injection pipes. It was observed that tile point injection of the vertical pipe system generates a gel barrier that has a less lateral area than the injection through the horizontal pipe.

  • PDF

설비배관에서 용접봉에 따른 환경오염 (Environments Pollution Caused by Welding Rod in the Process of Pipe Working)

  • 윤영묵;이우람;이철구;김주한
    • 한국생산제조학회지
    • /
    • 제18권3호
    • /
    • pp.300-306
    • /
    • 2009
  • Welding technology is applicable in many kinds of fields, with the help of its advantages such as easy operational procedure and structural simplification. However, in the process of welding, hazardous materials and fumes cause huge fire broke-outs, explosions, and health-conscious problems. Also, as heavy metals in fumes have a harmful effect on the environment, recently, this has emerged as a urgent social issue. This study has been aimed at the recommendation of the most environment-friendly, among materials currently used in plumbing welding, and it has been done at the result of the analysis of amount, ingredient, and size in collected fumes created in the experiment of welding five rods to galvanized steel pipes and steel pipe ones. At the test result, due to the effect of Zn-coating, galvanized steel pipes, when welded to rods, created more fumes than steel pipe ones. In the mean time, when it comes to welding rods, among five, WR-03 produced fumes the least. Therefore, a combination of the test results clearly indicates that the case of welding WR-03 to cast-iron pipes turned out to be the most environment-friendly.

  • PDF

파이프하우스의 구조안전에 관한 실험적 연구 (Experimental Studies on the Structural Safety of Pipe-Houses)

  • 김문기;남상운
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.17-24
    • /
    • 1995
  • 본 연구는 파이프하우스의 구조적 안전성을 검토하는데 필요한 기초자료를 구축하기 위하여 실시하였다. 지반에 매입된 파이프의 지점상태를 검토하여 적합한 구조해석 모델을 찾고, 파이프를 말뚝기초로 가정했을 때의 파이프의 지지력 및 인발 저항력을 구하기 위하여 모형 실험을 실시하였으며, 그 결과를 요약하면 다음과 같다. 1. 파이프하우스의 지점상태를 검토해본 결과 단동 하우스에서는 수평 및 연직하중 모두 고정으로, 연동하우스에서는 수평하중 재하시 힌지, 연직 하중 재하시 고정으로 해석하는 것이 실험치에 더 가까운 것으로 나타났다. 2. 지반에 매입된 파이프의 인발저항력은 파이프 직경 및 매입깊이에 따라 논의 연한지반에서는 35-54kg, 밭의 보통지반에서는 61-98kg, 단단한 지반에서는 108-120kg이상으로 나타났으며, 파이프와 흙사이의 주변마찰력은 1.51-4.76t/$m^2$정도의 범위를 보였다. 3. 파이프 직경 및 매입깊이에 따른 기초 지지력은 연한지반의 경우 35-76kg, 보통지반은 88-158kg, 단단한 지반은 131-305kg의 범위를 보였으며, 파이프의 선단지지력은 연한지반 0-22kg, 단단한 지반 22-140kg으로 나타났다. 4. 국내에서 많이 보급되어 있는 대표적인 파이프하우스의 경우, 적설심 30cm 까지는 파이프의 매입깊이가 30cm이면 지지력이 충분하지만 그 이상의 적설심에서는 지반의 종류에 따라 매입깊이를 증가시켜야 하고, 인발저항의 경우도 풍속 30㎧까지는 매입깊이 30cm이면 충분하지만 그 이상의 풍속에 대하여는 매입깊이를 증가시키거나 보강이 필요한 것으로 나타났다.

  • PDF

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가 (Assessment of Daylight Environment on Light Pipe System Under Different Solar Position)

  • 신화영;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

상수도관망에서 분리한 잔류염소 내성균에 관한 연구 (Study on the Chlorine-Resistant Bacteria Isolated from Water Pipe Network)

  • 현재열;윤종호
    • 한국물환경학회지
    • /
    • 제27권3호
    • /
    • pp.334-341
    • /
    • 2011
  • The free residual chlorine of tap water samples, collected from 266 faucets on the water pipe network in Daegu City, was between 0.1 and 0.79 mg/L. On microorganic tests, general bacteria and the coliform goup were not detected and thus the tap water was turned out to be fit to drink. In particular, samples of which free residual chlorine was 0.1 mg/L and over were cultured in R2A agar media at $25^{\circ}C$ for 7 days, and as a result heterotrophic bacteria were detected in 65.9% of samples; (1). The closer tap water got to the faucet from the stilling basin, the lower residual chlorine concentration became but the more the bacterial count became. And, more bacteria were detected in the R2A agar medium than in the PCA medium. (2). In the case of separated strains, most colonies were reddish or yellowish. 16S rRNA sequence was identified as Methylobacterium sp. and Williamsia sp., and yellow strain was identified as Sphingomonas sp., Sphingobium sp., Novosphingobium sp., Blastomonas sp., Rhodococcus sp. and Microbacterium sp. White strain was identified as Staphylococcus sp. (3). Sterilized tap water in polyethylene bottles was inoculated with separated strain and was left as it was for 2 months. As a result, bio-film was observed in tap water inoculated with Methylobacterium sp. and Sphingomonas sp. It was found that heterotrophic bacteria increased when free residual chlorine was removed from tap water in the water pipe network. Thus, there is a need to determine a base value for heterotrophic bacteria in order to check the cleanliness of tap water in the water pipe network.

복사효과를 포함하는 수평관 표면의 온도제어 (Surface Temperature Control of an Insulated Horizontal Pipe under Thermal Radiation Environment)

  • 강병하;피창헌;김석현
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.54-60
    • /
    • 2011
  • Procedures for estimation of insulation thickness for a horizontal pipe for condensation control or personnel protection has been investigated, parallel to the previous work of a vertical wall case. Parameters include pipe diameter, emissivity, thermal conductivity, and operating temperatures. The results indicated that the surface emissivity plays a very important role in the design of insulation, specially for the case of high temperature application with low Bi. The effect of surface radiation in such case could be up to 65% of the total. Required insulation thickness for the surface temperature control increases as pipe diameter increases and as surface emissivity decreases. Adequate revision of specifications or standards to include newly invented insulation materials with high emissivity has been also suggested.

Structural Integrity Evaluation of Fuel Test Loop Submerged in Water Subjected to Postulated Pipe Rupture

  • Lee, Choon-Yeol;Kwon, Jae-Do;Lee, Yong-Son;Kim, Kil-Soo;Kim, Jun-Yeun
    • Journal of Mechanical Science and Technology
    • /
    • 제14권2호
    • /
    • pp.215-225
    • /
    • 2000
  • The structural integrity of the fuel test loop (FTL) in a Korean experimental reactor is evaluated when the FTL, submerged in a water environment, is subjected to a postulated pipe rupture. The analyses are performed under static and dynamic conditions, imposing the thrust force history at each postulated pipe rupture section. Through analysis the following results are found: l) A double ended guillotine can not be expected based on the toughness of the material, 2) the structural integrity of the chimney surrounding the FTL would not impede the structural integrity by the pipe whip. All analyses are performed by finite element methods.

  • PDF

폴리머 시멘트 모르타르를 이용한 철근콘크리트 흄관 라이닝에 관한 연구 (A Study on the Lining of Reinforced Concrete Pipe Using Polymer-Modified Mortar)

  • 김영집;김한엽;조영구;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.333-338
    • /
    • 2000
  • At present, reinforced concrete pipe has been widely used as drain pipe. However, many reinforced concrete pipe is exposed at deteriorated environment by the growth of a sulfur-oxidizing bacterium isolated from corroded concrete. The purpose of this study is to evaluate the effects of lining by polymer-modified mortar on the development in durability of reinforced concrete pipe. Polymer-modified mortars ate prepared with various polymer typer as cement modifier and polymer-cement ratio and rested for compressive and flexural strengths, adhesion in tension, acid resistance test, freezing and thawing test, and lining test of product in the field. From the rest results, it is apparent that polymer-modified mortars have good mechanical properties and durability as lining material. In practice, all polymers can be used as lining materials for reinforced concrete pip, and type of polymer, and polymer-cement ratio and curing conditions are controlled for good lining product.

  • PDF

U형 히트파이프의 작동 특성에 관한 연구 (A Study on the Operational Characteristics of a U-shape Heat Pipe)

  • 강환국;김철주;이용수
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1711-1720
    • /
    • 2001
  • In this study, the heat transfer characteristics of a U-shape heat pipes were investigated. Heat is supplied to the U heat pipe through its middle zone(evaporator), and is released to the environment through its both arms(condensers). Both heat transfer coefficients and heat transport limitations were measured and compared with correlations previously developed for straight type heat pipes. Special concerns were focused to the cases, when each of condensers were submitted to a different cooling conditions, relatively. As a result. the heat transfer limitation of a U-shape heat pipe was found out to be 10∼15% less than the value for a straight heat pipe with an equivalent size.

현장중심형 하수도용 연성관의 거동특성에 대한 고찰 - 다짐도·변형률·강성 간의 관계정립 - (A Case Study of Flexible Sewer Pipes Behaviors - Compaction Ratio·Inner Deflection Ratiov·Ring Stiffness -)

  • 김영진
    • 복합신소재구조학회 논문집
    • /
    • 제4권2호
    • /
    • pp.31-38
    • /
    • 2013
  • As the Sewer Pipe is transformed by the expansion of life cycle as a result of the technology development, flexible pipe is developed by the transformed environmental conditions. To change pipe design, three phases(compaction ration - inner deflection ratio - ring stiffness) should be considered in design conditions. The input data of pipe design were provided by compaction-inner deflection ratio-ring stiffness. M oreover, The guidelines of sewerage pipes should be considered by flexible pipes design criteria.