• Title/Summary/Keyword: environment condition

Search Result 6,762, Processing Time 0.04 seconds

Smart Power Management System for Leisure-ship

  • Park, Do-Young;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.35 no.9
    • /
    • pp.749-753
    • /
    • 2011
  • A leisure ship has a stand-alone type power system, and a generator is in use on this condition. But the generator cannot be operated in condition of leisure activity, ocean measurement and etc, because of environment and noise. Recently, renewable energy system is connected with power system of the leisure-ship for saving energy. The renewable energy system can not supply the stable power to leisure-ship because power generation changes according to weather condition. And most of the leisure ship is operated without methodical power management system. This study's purpose is to develop SPMS(Smart Power Management System) algorithm using the renewable energy (photovoltaic, wind power and etc.). The proposed algorithm is able to supply stable the power according to operation mode. Furthermore, the SPMS manages electric load (sailing and communication equipment, TV, fan, etc.) and reduces operating times of the generator. In this paper, the proposed algorithm is realized and executed by using LabVIEW. As a result, the hour for operating the generator is minimized.

Faultproof Design in Space for Monopropellant Rocket Engine Assembly (단일추진제 로켓 엔진 어셈블리를 위한 우주 공간에서의 과실 방지 설계)

  • Han, Cho-Young;Kim, Jeong-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1377-1384
    • /
    • 2003
  • An analysis has been performed for active thermal control of the KOMPSAT monopropellant rocket engine assembly, i.e., dual thruster module(DTM). The main efforts of this work have been directed at determining proper heater sizes for propellant valves and catalyst beds necessary to maintain their temperatures within specified temperature ranges under KOMPSAT environment and operational conditions. The TAS incorporated with TRASYS thermal radiation analyzer was used to establish a complete heat transfer model which allows to predict the DTM temperature as a function of time. The thermal analysis has been performed in transient mode to verify the appropriate power for catalyst bed heaters necessary to increase catalyst bed temperature to the required value within a specified period of time. Similar analysis has been executed to validate the heater power for the thermostatically controlled primary and redundant heater circuits used to prevent hydrazine freezing, i.e., single fault. Moreover the effect of the radiative property of thermal control coating of heat shield was examined. Thruster firing condition was also simulated for the heat soakback condition. As a consequence, all thermal analysis results for DTM satisfactorily met the thermal requirements for the KOMPSAT DTM under the worst case average voltage, i.e. 25 volt.

Distribution and Ecological Characteristics of Native Iris Odesanensis in Mt. Naeyon

  • Ahn, Young-Hee;Lee, Sang-Hyun;Lee, Sung-Je;Kang, Ki-Ho
    • Journal of Environmental Science International
    • /
    • v.15 no.12
    • /
    • pp.1103-1107
    • /
    • 2006
  • Iris odesanensis Y.N. Lee is one kind of species among 54 endangered plant species designated by the Ministry of Environment in Korea. It is very rare native plant throughout the country. Therefore, this study was conducted to investigate the native Iris odesanensis in Mt. Naeyon for their distribution and ecological characteristics. They were mostly distributed mid-slope of the mountain from 443m to 498m altitude. They were located lower part of valley and provided enough humid condition. They had proper light and humidity conditions as they faced south south west, south south east, and south. They were also located at the places deciduous woody plants were distributed for proper light conditions for spring blooming. Iris flowered to use light at the period before the trees thickly covered with foliage. However this unfavorable light condition caused low percentage as 7.04% of blooming individuals in this study. In herbaceous, Vioia chaerophylloides(Regel) W. Hocker, Carex siderosticta Hance, Erythronium japonicum Decne., Oxalis obtriangulata Max., Hepatica asiatica Nakai, Lilium tsingtauense Gilg et cetera were appeared well. We propose that proper pruning of upper branches of the deciduous trees is needed for suitable light condition of management of native sites.

A Study of Board the Train Designed for Wheelchair Users on Welding Condition (휠체어 사용자를 위한 열차 탑승 장치 설계와 용접 조건)

  • Lee, Chul Ku;Kim, Incheol;Lee, Wooram
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.92-99
    • /
    • 2013
  • The ratio of mobility handicapped was 12,110,000 in late 2009 about 24.4% of total population. The number of handicapped population is increasing continuously due to traffic accidents and industrial disasters. Therefore, the purpose of this research is to suggest a design for passengers on wheelchairs to get into and off to raise handicapped or elderly people's right of mobility. The scope of this research is mobility handicapped especially wheelchair passengers who use vans, small buses, and trains. The ramp design of vans is module form. The ramp is moved with screw jack and guides are installed on each side to increase stability. Moreover, a bridge was installed for smooth getting in and off of the van. The ramp design for small bus is lowed by 200m in order not to have obstacle such as speed bump when getting in or off. In order to reduce vulnerable environment and administration, air slide cylinder was chosen. Lastly, for the ramp design of train, the principle of link was used that the simpler structure made the weight lighter and installation in the train became easier. If we look at the conjugation condition of heterogeneous materials to produce a ramp, proper welding condition for cold steel plate and stainless plate is 3kW output and 3-5m/min of welding speed using laser beam seems proper.

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

Experimental Studies on Comparison of Stress Corrosion Cracking Generation Due to Pipe Material Degradation in the Primary Stage of the Nuclear Power Plant (원전 1차 측 배관재질의 열화에 따른 응력부식균열 발생 비교 실험 연구)

  • Park, Kwang-Jin;Lee, Gyu-Young;Bae, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.108-113
    • /
    • 2007
  • In this report, stress corrosion cracking generation due to pipe material degradation in the primary stage of the nuclear power plant was investigated. Firstly, after artificially degrading the CF8A steel during 2, 4, and 6 months in actual temperature, $400^{\circ}C,$ assessed corrosion susceptibility of the degraded material following ASTM G5 standard. And next, the S.C.C. tests for the degraded material were conducted under the condition of $60^{\circ}C,$ 2wt.% H2BO3+Li70H solution, 0.8 oy. From the results, Corrosion rates linearly increased with degradation period and solution temperature increase. And both the raw material and the degraded materials were not failed in the S.C.C. test condition. In spite of long time test (about 3,900 hrs) under S.C.C. condition, surface pits or surface corrosion by the electro chemical reaction were not observed. And also, even though the nondestructive DCPD and ACPD methods were applied to on-line monitor the S.C.C. failure processes it was impossible because the surface pits and cracks were not generated.

  • PDF

Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy (태양열 시설원예 난방시스템 장기실증 성능분석 연구)

  • Lee Sang-Nam;Kang Yong-Heack;Yu Chang-Kyun;Kim Jin-Soo
    • New & Renewable Energy
    • /
    • v.1 no.2 s.2
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

A Study on the Clothing Composition to the Comfortable Clothing Climate; Clothing Weights and Thermal Sensation( I ) (쾌적한 의복기후를 위한 피복구성에 관한 연구 ( I ) -착의양과 한서감각을 중심으로-)

  • Park Woo Mee;Lee Soon Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.7 no.1
    • /
    • pp.37-43
    • /
    • 1983
  • The objective of the study is to obtain the basic data to establish the standard value of proper clothing weights in the change of thermal environment. For the purpose of this research, clothing weight and thermal sensation have been collected from 160 college student in Seoul and Kwangju area in April, July, October. Results are as follows : 1. Subjects were in Comfortable condition, particularly in Spring and Autumn. But in summer they were in warm condition and the case were reversed in winter when they were under cool condition. 2. The frequency of comfortable thermal sensation were low below 16.5 degree, above 27.5 degree, and were high between 16.5 degree and 23 degree on room temperature. 3. Generally, the positive correlation were found between clothing weights and thermal sensation. 4. Clothing weights and thermal comfort were as follows. Season : Spring, Autumn, Room Temperature(${\circ}C$) : 16.3$\~$23, Clothing Weights($g/m^2$) : 589.9$\~$750.6, Season : Summer Room Temperature(${\circ}C$) : 27$\~$32, Clothing Weights($g/m^2$) : 362.4$\~$432.5, Season : Winter, Room Temperature(${\circ}C$) : 12.5$\~$19.3, Clothing Weights($g/m^2$) : 913.7$\~$1206.2

  • PDF

PHOSPHORUS RELEASE AND UPTAKE ACCORDING TO NITRATE LOADING IN ANOXIC REACTOR OF BNR PROCESS

  • Kim, Kwang-Soo
    • Environmental Engineering Research
    • /
    • v.10 no.5
    • /
    • pp.257-263
    • /
    • 2005
  • A batch and a continuous type experiments were conducted to test the conditions for simultaneous phosphorus release and uptake, and denitrification, taking place in one process. The bacteria able to denitrify as well as to remove phosphorus were evaluated for the application to biological nutrient removal(BNR) process. In the batch-type experiment, simultaneous reactions of phosphorus release and uptake, and also denitrification were observed under anoxic condition with high organic and nitrate loading. However the rate and the degree of P release were lower than that occurred under anaerobic condition. BNR processes composed of anaerobic-anoxic-oxic(AXO), anoxic-anaerobic-oxic(XAO) and anoxic-oxic(XO) were operated in continuous condition. The anoxic reactors in each process received nitrate loading. In the AXO process, P release in anaerobic reactor and the luxury uptake in oxic reactor proceeded actively regardless to nitrate loading. However in XAO and XO processes, P release and luxury uptake occurred only with the nitrate loading less than $0.07\;kg{NO_3}^--N$/kgMLSS-d. With higher nitrate load, P release increased and the luxury uptake decreased. Therefore, it appeared that the application of denitrifying phosphorus-removing bacteria (DPB) to BNR process must first resolve the problem with decrease of luxury uptake of phosphorus in oxic reactor.

Corrosive Wear of Alloy 690 Tubes in Alkaline Water

  • Hong, Seung Mo;Jang, Changheui;Kim, In Sup
    • Corrosion Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.126-131
    • /
    • 2009
  • The interaction between wear and corrosion can significantly increase total material losses in water chemistry environment. The corrosive wear tests of a PWR steam generator tube material (Alloy 690) against the anti vibration bar material (409 SS) were performed at room temperature. The tests were performed in alkaline water chemistry conditions. NaOH solution was selected for test condition to investigate the corrosive wear effect of steam generator tube material in alkaline pH condition without other factors. The flow induced vibration can caused tube damage and the corrosion can be occurred by water chemistry. The test results showed that, in the alkaline solution at pH 13.9, the corrosion current density was increased about ten times than that in the distilled water. And wear rate at pH 13.9 was increased about ten times from that at neutral condition. However, the wear rate was decreased with time. The decrease would be attributed to the change in roughness of specimen or sub-layer of the worn surface with time. From microstructure observation, severe abrasive shape and several wear debris were found. From those results, it could infer that the oxide film on Alloy 690 changed to easily breakable one in the alkaline water, and then abrasion with corrosion became the main wear mechanism.