• Title/Summary/Keyword: environment condition

Search Result 6,759, Processing Time 0.044 seconds

Characteristics of agronomy to vitamin A strengthening rice at large scale GMO field (대규모 GMO 포장에서 비타민 A 강화 벼의 농업특성 검정)

  • Lee, Hyun-Suk;Ryu, Tae-Hun;Jung, Hee-Young;Park, Soon-Ki;Park, Gyu-Hwan;Sohn, Jae-Keun;Kim, Kyung-Min
    • Korean Journal of Breeding Science
    • /
    • v.42 no.1
    • /
    • pp.56-60
    • /
    • 2010
  • This study was carried out to develop of macro-protocol and the biosafety guide Golden Rice, modified vitamin A at large scale GMO field. Commercialization of genetically modified (GM) plants will be required the assessment of risks associated with the release of GM plants that should include a detailed risk assessment of their impacts in the environment and human health. Prior to GM plant release, applicants should provide the information on GM crops for approval. A total of $4,700m^2$ GM field, each of Golden Rice and 'Nakdong' were used for further analysis on agronomic traits and pathogenesis. Generally plant growth and panicle number in the transgenic lines were lower than in the wild type under field condition. The major agronomic traits such as plant growth, grain quality in Golden Rice were similar than in 'Nakdong'. The yield difference was due to reduced ripened rate and the 1,000 grain weight. The grain shape was similar donor plant, however, color of brown rice was different from segregation. Also the difference of pathogenesis reaction was not significant in the leaf blast and sheath blight between Golden Rice and 'Nakdong'. These results provided the agronomic data and pathogenesis for risk assessment analysis of Golden Rice and suggested that the macro-protocol could be useful to detect GM plants.

Development of the Dredged Sediments Management System and Its Managing Criteria of Debris Barrier (사방댐 준설퇴적물 관리시스템 개발 및 관리기준 제안)

  • Song, Young-Suk;Yun, Jung-Mann;Jung, In-Keun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.267-275
    • /
    • 2018
  • The dredged sediment management system was developed to have an objective, quantitative and scientific decision for the optimum removal time of dredged sediments behind debris barrier and was set up at the real site. The dredged sediment management system is designed and developed to directly measure the dredged sediments behind debris barrier in the field. This management system is composed of Data Acquisition System (DAS), Solar System and measurement units for measuring the weight of dredge sediments. The weight of dredged sediments, the water level and the rainfall are measured in real time using the monitoring sensors, and their data can be transmitted to the office through a wireless communication method. The monitoring sensors are composed of the rain gauge to measure rainfall, the load cell system to measure the weight of dredged sediments, and water level meter to measure the water level behind debris barrier. The management criteria of dredged sediments behind debris barrier was suggested by using the weight of dredged sediments. At first, the maximum weight of dredged sediments that could be deposited behind debris barrier was estimated. And then when 50%, 70% and 90% of the maximum dredged sediments weight were accumulated behind debris barrier, the management criteria were divided into phases of Outlooks, Watch and Warning, respectively. The weight of dredged sediments can be monitored by using the dredged sediment management system behind debris barrier in real time, and the condition of debris barrier and the removal time of dredged sediments can be decided based on monitoring results.

Research on Development of a Customized Nursery School for Nurses (간호사를 위한 맞춤보육어린이집의 개발에 관한 연구)

  • Kang, Ki-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.407-416
    • /
    • 2019
  • This study is about a Customized Nursery School where working women can support work - life balance and a reduction in retirement or turnover. The research method is to identify the current status of Customized Nursery services and to recognize the recognition and need of the operation of Customized Nursery School. The importance of securing skilled nurses and preventing them from changing their jobs for the health and safety of people cannot be emphasized enough. A Customized Nursery School must be opened to reduce the retirement or change of jobs of working women nurses and to provide care for continuous work in three shifts from 365days to support the balance between the working mother and family. It is considered that nurses will put their children in relief when using retired nurses who have the ability to work 24hour rotation in a Customized Nursery School and when a Customized Nursery School be ran suited for the condition and demand of working women nurses, it is expected to reduce retirement and the change of jobs, also to give positive effect on marrige and family planning which would make improvement in low birthrate. To activate the Customized Nursery School, Creating a secure learning environment and qualification of educators great effort should be put. A program curriculum based on 'basic life and habits' should be the center of education. Continuous management and effort will need to be placed in continuous development of educators.

A Study on Stabilization of Underwater TAS Winch System Deploy/Recover Operation Performance (수중용 TAS윈치 전개/회수 성능 안정화 방안에 관한 연구)

  • Chang, Ho-Seong;Cho, Kyu-Lyong;Hwang, Jae-Gyo;Lee, Sang-Yong;Kim, Yong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.472-482
    • /
    • 2019
  • This paper describes the stabilization of underwater TAS winch system Deploy/Recover operation performance. TAS winch installed on the stern of submarine performs to deploy/recover sensor, towing cable and rope tail which is deployed from the stern and separated from submarine itself. Also TAS winch provides transmission path of power to the sensor and data transmitting/receiving path which data are acquired from underwater environment like sound, depth and temperature. At the step of TAS winch evaluation test, sporadic standstill and rotating speed oscillation phenomenon were occurred. Winch motor provides the available torque to deploy/recover TAS and root cause analysis to the winch motor was done to find exact reason to sporadic malfunction. When winch motor was disassembled, eccentricity of rotor, slip-ring and the other composition part for winch motor were found. These might cause magnetic field distortion. To make TAS winch system more stable and block magnetic field distortion, this paper suggests methods to enhance fixing status installed in winch motor. For reliable data acquisition for TAS winch operation, the deploy/recover function of the improved type of TAS winch was verified in LBTS making similar condition with sea status. At the end of stage, improved type of TAS winch was tested on some functions not only deploy/recover function, but sustainability of TAS operation on specific velocity, steering angle of submarine in the sea trial. Improved type of TAS winch was verified in accordance with design requirement. Also, validity of suggested methods were verified by the sea trial.

A Study on the Site Acceptance Test(SAT) Evaluation Algorithm of Energy Storage System using Li-ion Battery (리튬이온전지를 이용한 전기저장장치의 SAT용 성능평가 알고리즘에 관한 연구)

  • Park, Jea-Bum;Kim, Byung-Ki;Kim, Mi-Sung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.26-37
    • /
    • 2019
  • Recently, standardization of installation progress and technology of site acceptance test(SAT) for energy storage system(ESS) are being required due to performance of ESS depending on working condition and environment even though the quality and safety of each component of ESS is guaranteed. And also, it has been required to perform not only performance testing by H/W equipments but also performance verification by S/W tool, in order to more accurately and reliably validate the performance of the ESS in advanced countries. Therefore, this paper proposes evaluation algorithm for SAT to evaluate performance of ESS and presents modeling of SAT test equipment for ESS by using PSCAD/EMTDC. Furthermore, 30[kW] scaled portable test equipments is implemented based on the proposed algorithm and modeling. From the various simulation and test results, it is confirmed that performance of ESS related to characteristics of capacity and Round-trip efficiency, Duty-cycle efficiency, low voltage ride through(LVRT) and Anti-islanding can be accurately evaluated and that the simulation results of PSCAD/EMTDC are identical to test results of 30[kW] test equipment.

An Integrated Review on Main Caregiver's Burden of Elderly in Korean Nursing Home (한국 요양시설 노인의 주 돌봄자 부담감에 대한 통합적 고찰)

  • Kim, Eun Jeong;Sung, Kyung Mi
    • Journal of Digital Convergence
    • /
    • v.17 no.6
    • /
    • pp.267-277
    • /
    • 2019
  • The purpose of this study is to investigate the burden of caring for the care-givers of the elderly in Korea by using an integrated literature review method. A total of 23 studies were analyzed using a search database. When care-givers had higher sense of filial and guilt or more than two diseases, they showed high level of feeling of burden. Also, they had high level of feeling of physical burden by their oldness, service period (especially at the period of 1-3 years). In the feeling of economic burden, they had high level of feeling of burden by their oldness, or elderly's disease periods. The feeling of burden by psychological condition was found in elderly in aged and the beginning of admission of nursing home. The feeling of burden by environment situation was found when the functional status of the elderly was bad. Therefore, we need to concern care-givers's feeling of burden with elderly people in the nursing home. In the future, I believe that the findings of this study will be helpful for development of the intervention program for alleviate burden for the care-giver.

Development of Performance Analysis 80 kW High-efficiency Permanent Magnet Generator for Radar System Power Supply (레이더 체계 전원공급용 80 kW급 고효율 영구자석형 발전기 개발 및 성능분석)

  • Ryu, Ji-Ho;Cho, Chong-Hyeon;Chong, Min-Kil;Park, Sung-Jin;Kang, Kwang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.60-71
    • /
    • 2019
  • Electrical power supply is needed to operate the radar system in the field. In addition, it should not cause performance deterioration under the environmental factors due to characteristics of military equipment, and should not cause malfunction due to electromagnetic waves generated in radar, and then should not cause malfunction in radar equipment. Therefore, By applying a permanent magnet to the rotor of the generator, light weighting and high efficiency of generator were achieved. As a result, electrical performance test of the generator, the rated output power was 80.8 kW, the maximum output power was 88.1 kW, and the output power efficiency was 98.1 % under the full load condition. When the load capacity of the generator was changed from no load to full load, the maximum voltage variation was 3.6 % and the frequency variation was 0.3 %. As a result of the transient response test for measuring the output power of the generator according to the load characteristics change, the maximum voltage variation of 7.9 %, frequency variation of 0.5 % were confirmed, and the transient response time was 2.1 seconds. Environmental tests were conducted in accordance with MIL-STD-810G and MIL-STD-461F to evaluate the operability of the generator groups. Normal operation of radar system generator group was confirmed under high temperature and low temperature environment conditions. Electromagnetic tests were conducted to check if electromagnetic wave generated from both radar system and generator group in operation caused any performance deterioration to each other. As a result, it was confirmed that the performance deterioration due to electromagnetic wave inflow, radiation, and conduction did not occur. It is expected that it should be possible to provide high efficiency power supply and stable power supply by applying to various military system as well as radar system.

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

Survey on the Relationship between the Number of Medical Technologists and the Medical Test Count (검사건수에 따른 임상병리사의 인원편성에 관한 설문조사 분석)

  • Kim, Junghyun;Kim, Dae-Eun;Yoon, Joong-Soo;Lee, Jeong Soo;Park, Tae-Wha
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.1
    • /
    • pp.93-104
    • /
    • 2019
  • This study examined the relationship between the number of medical technologists and the medical test count. Data was obtained from 441 medical technologists in a hospital through a self-reported questionnaire. The Pearson correlation test, student's t-test, ANOVA or descriptive statistics were performed for data analysis. The distribution of medical technologist according to the size of hospitals was small 5.8, medium 14.9, large 25.8, and super 45.4. The analysis demonstrated a relationship between the number of medical technologists and the number of medical tests in the field, number of clinical tests per MT, and number of optimal medical test per MT according to the hospital size (P<0.001). The average time for quality control by the department at a higher hospital was less than two hours. In terms of the satisfaction of salary, work environment, test accomplishment, and welfare service, the dissatisfaction of medical technologists in small and medium hospitals was higher than those in large and super hospitals. Overall, a focus on intensifying systemic supplementation and improving the condition of medical technologists is needed to provide reliable data for medical examinations in medical areas.

Acute Toxicities of Emulsifiable Concentrates and Granules of Valeriana fauriei Briquet and Alpinia galangal Swartz Essential Oils against Cyprinus carpio (길초근(Valeriana fauriei Briquet) 및 양강근(Alpinia galangal Swartz) 정유의 유제 및 입제제형의 잉어(Cyprinus carpio)에 대한 급성독성)

  • Jeon, Hwang-Ju;Kim, Kyeongnam;Kim, Yong-Chan;Lee, Sung-Eun
    • Korean Journal of Environmental Biology
    • /
    • v.36 no.4
    • /
    • pp.659-664
    • /
    • 2018
  • In this study, two essential oils (EOs) extracted from Aleriana fauriei and Alpinia galangal were formulated as an emulsifiable concentrate (EC) and a granule. In the evaluation of their acute toxicity on fishes, Cyprinus carpio adults were used and the toxicities were determined in a static condition. The formulations were prepared from the essential oil extracted by three different methods namely steam distillation (SD), solvent extraction (SE) and supercritical fluid extraction (SFE). The acute toxicities were calculated using $LC_{50}$ values. Among EOs, only the EO extracted by solvent showed acute toxicities on carps. Some of the EC, EOs of Aleriana fauriei did not exhibit toxicity, while EOs from Alpinia galangal showed potent acute toxicities on carps. Among the granules, granules formulated with Aleriana fauriei EO extracted by SD method and Alpinia galangal EO extracted by SFE method showed acute toxicities on fishes. Nevertheless, $LC_{50}$ of ECs and granules formulated with all types of EOs in this study was higher than the fish toxicity level III for pesticides suggested by Korea Rural Development Administration. Furthermore, cytochrome P450 1A and glutathione S-transferase were confirmed as biomarkers in carps in response to the exposure to Alpinia galangal EO extracted by SD and SFE method, tracking Alpinia galangal EO in the aquatic environment.