• Title/Summary/Keyword: environment condition

Search Result 6,759, Processing Time 0.038 seconds

Efficient Outlier Detection of the Water Temperature Monitoring Data (수온 관측 자료의 효율적인 이상 자료 탐지)

  • Cho, Hongyeon;Jeong, Shin Taek;Ko, Dong Hui;Son, Kyeong-Pyo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.5
    • /
    • pp.285-291
    • /
    • 2014
  • The statistical information of the coastal water temperature monitoring data can be biased because of outliers and missing intervals. Though a number of outlier detection methods have been developed, their applications are very limited to the in-situ monitoring data because of the assumptions of the a prior information of the outliers and no-missing condition, and the excessive computational time for some methods. In this study, the practical robust method is developed that can be efficiently and effectively detect the outliers in case of the big-data. This model is composed of these two parts, one part is the construction part of the approximate components of the monitoring data using the robust smoothing and data re-sampling method, and the other part is the main iterative outlier detection part using the detailed components of the data estimated by the approximate components. This model is tested using the two-years 5-minute interval water temperature data in Lake Saemangeum. It can be estimated that the outlier proportion of the data is about 1.6-3.7%. It shows that most of the outliers in the data are detected and removed with satisfaction by the model. In order to effectively detect and remove the outliers, the outlier detection using the long-span smoothing should be applied earlier than that using the short-span smoothing.

Soil Physiochemical Properties in Leaf-yellowing Black Locust (Robinia Pseudo-acacia L.) Stands (아까시나무 황화현상 발생임분의 토양 이화학적 특성)

  • Lee, Seung-Woo;Byun, Jae-Kyoung;Ji, Dong-Hun;Kwon, Young-Dae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.42 no.6
    • /
    • pp.409-414
    • /
    • 2009
  • In 1970's Black locust(Robinia pseudoacacia) had been widely planted Korea as an important forest greening species for erosion control afforestation. Since 2000, however, the tree's leaf-yellowing symptom has often been observed at a limited region and then spreaded out over the country in 2006. This study was conducted to study soil physiochemical properties of black locust stands with and without the leaf-yellowing symptom in Osan, Gyeonggi province. Most of soils in sampling sites were mostly slightly eroded, dry, and moderately dry. Available soil depth(16cm) and total soil depth(26cm) in leaf-yellowing (LY) site were significantly lower than in non leaf-yellowing (Non-LY) site's soil depths which were 30cm and 56cm, respectively. And solid phase proportion and bulk density in soils were lower in LY site than in non-LY site soils, while soil liquid phase proportion was also low. It could reflect that LY site soils might have a lower air and moisture movement in the rhizosphere of black locust stand compared with non-LY site soils. Soil acidity in both sites was very strong acid, soil pH (4.42) of LY site was slightly lower than non-LY site's (pH 4.54). Content of available phosphorous, exchangeable $Ca^{2+}$ and $Mg^{2+}$ and percent base saturation were less than LY site. These results indicated that soil physiochemical condition in LY site, more deteriorated than non-LY site, should adversely affect the retention and supply capacity of soil nutrients and moisture. Therefore the black locust may be more sensitive to other environmental stresses.

Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy (화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가)

  • Lee, Chan Young;Lee, Sang Hun;Park, Jin Hwan
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • In this study, both evaluations by visual imaging for exterior view of coating and by EIS were executed for epoxy primer coated specimens deteriorated by accelerated test, and comparison and analysis were carried out for 2 evaluation methods. In the comparison between total damaged area ratio acquired by image processing method and deterioration point, higher deterioration points were appeared for rusted specimens than for non-rusted specimens. It is attributed that deterioration point per unit area ratio given for rust is higher than for peeling. In the comparison between total damaged area ratio and EIS result, impedance of coating was largely decreased as about TEX>$10^4{\Omega}{\cdot}cm^2$ or less when rust area ratio is more than about 0.1%, and blistering area ratio is more than about 3%. Charge transfer resistance ($R_{ct}$) and double layer capacitance ($C_{dl}$) values were appeared for all specimens except 2 ones, which shows that water is accumulated and steel substrate is corroded at coated film-steel interface. In the comparison between deterioration point and EIS result, more than 10 points as deterioration point were given for specimens of below $10^6{\Omega}{\cdot}cm^2$ of impedance at low frequency. For specimens deteriorated by NORSOK cyclic test, impedance was lowest of all, though deterioration point was not high. It is thought to be attributed that coating system and accelerated deterioration condition of cyclic tested specimens were different from those of main specimens. From the result, it is thought that coating resistance can be relatively more decreased than deterioration degree estimated from exterior view under more severe corrosion environment or in the present of more complex deterioration factors.

Minimized Radiation Dose of Patients Receiving High Dose Radioiodine(I-131) Therapy (고용량 방사성옥소(I-131) 치료환자의 피폭선량 저감화 연구)

  • Lee, Gui-Won
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.435-442
    • /
    • 2007
  • The number of thyroid diseases treated with radioiodine(I-131) is increasing steadily. The sharp increase in patients who require high dose radioiodine therapy greatly increased the need for new therapy rooms. Accordingly, interest in radiation exposure is rising as well, and is a major psychological stress factor for the patient and those who come in close contact with the patient. This study aimed to minimize the radiation exposure on discharge. Based on various previous reports, the decision for discharge should be individualized depending on many factors related to the patient's living or working environment. Educating patients repeatedly on the importance of sufficient oral hydration, while the adequate amount was relative to the patient's individual condition, greatly lowered the detected radiation measurement within the same admission period. In some cases, the period of admission could be abbreviated.

  • PDF

A Study of Impacts of Human Interference on the Gapcheon River Basin in Daejeon City (도시하천에 대한 인위적 간섭 특성 및 하천 관리 방안 - 대전시 갑천유역을 중심으로 -)

  • Kim, Doo-Il
    • Journal of the Korean association of regional geographers
    • /
    • v.14 no.1
    • /
    • pp.1-18
    • /
    • 2008
  • If there is no choice but to be urbanized, we should examine how human interference has had influences on the area to keep the river environment safe and stable. This study is aimed at finding improvement by examining the effect of human interference in Gapcheon river in Daejeon, which is developing fast. Distinctive features of human interference in Gapcheon river are followings. First, middle and upper reaches of Gapcheon river are being maintained and restored focusing on flood control but are scheduled to develop city and channel. Second, the rear area of middle and lower reaches of Gapcheon river is already developed into an urban district and solidified into artificial stream for leisure activities installing the artificial structure for fun. Third, lower reaches of Gapcheon river are in an unstable condition because of straightening waterway and developing rear area of river. Up to now, geographical features and bio-diversity of Gapcheon river has been ruined by the artificial management of river centered for technical engineering. From now on, followings should be considered for management of urban river. First, it is focused on maintaining eco system by itself than usage for human. Second, natural features of rear area of river should be taken into consideration and should be preserved before developing urban city and hills, back marsh, channel deposit and swamp to directly have an influence on river.

  • PDF

Characteristics of CaCO3 Sorbent Particles for the In-furnace Desulfurization (로 내 탈황을 위한 CaCO3 흡착제 입자의 분위기 기체와 체류 시간의 변화에 따른 특성)

  • Lee, Kang-Soo;Jung, Jae-Hee;Keel, Sang-In;Lee, Hyung-Keun;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.121-127
    • /
    • 2010
  • The in-furnace desulfurization technique is applied to the $O_2/CO_2$ combustion system for the carbon capture and storage (CCS) process because this combustion system does not need an additional chamber for the desulfurization. $CaCO_3$ sorbent particles, which have a wide range in size from a few nanometers to several tens of micrometers, are used for this process. In this study, an experimental system which can simulate the $O_2/CO_2$ combustion system was developed. $CaCO_3$ sorbent particles were exposed to the high temperature reactor at $1200^{\circ}C$ with various residence times (0.33-1.46 s) in air and $CO_2$ atmospheric conditions, respectively. The sorbent particles were then sampled at the inlet and outlet of the reactor and analyzed qualitatively/quantitatively using SMPS, XRD, TGA, and SEM. The results showed that the residence time and atmospheric condition in a high temperature reactor can affect the characteristics of the $CaCO_3$ sorbent particles used in the in-furnace desulfurization technique, such as the calcination rate and reaction mechanism.

Determination of Short-term Bioconcentration Factor and Partition Coefficient on Chlorothalonil in Carassius auratus(goldfish) (Carassius auratus(goldfish)를 이용한 Chlorothalonil의 단기간 생물농축계수와 분배계수의 측정)

  • 차춘근;전봉식;민경진
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.3
    • /
    • pp.38-47
    • /
    • 1995
  • The Bioconcentration factor (BCF) is used as an important criterion in the risk assessment of environmental contaminants. Also it can be used as indicator of biomagnification of environmentally hazardous chemicals through food-chain as well as a tool for ranking the bioconcentration potential of the chemicals in the environment. This paper reports the measured BCF value on Chlorothalonil in Carassius auratus(goldfish), under steady state, and examined correlation between the BCF value and the partition coefficient or acute toxicity or physicochemical properties. Carassius auratus(goldfish) was chosen as test organism and test period were 3-day, 5-day. Experimental concentrations were 0.005, 0.01 and 0.05 ppm. Chlorothalonil in fish tissue and in test water were extracted with n-hexane and acetonitrile. GC-ECD was used to detecting and quantitating of Chlorothalonil. Partition coefficient was determined by stir-flask method. $LC_{50}$ was determined on Chlorothalonil. Carbaryl and BPMC. The obtained results were as follows. 1. It was possible to determine short term BCFs of Chlorothalonil through relatively simple procedure in environmental concentrations. 2. $BF_3$ of Chlorothalonil in concentration of 0.005, 0.01 and 0.05 ppm were 2.1866$\pm$0.23446, 3.5269$\pm$0.23517, 10.2045$\pm$0.18053 and BCFs were 6.6543$\pm$0.55257, 6.9774$\pm$0.02500, 23.4576$\pm$2.06884, respectively. 3. Chlorothalonil concentration in fish extract and BCFs of Chlorothalonil were increased as increasing test concentration and prolonging test period. 4. Fate of test-water concentration on Chlorothalonil was greater than that of control-water con-centration. It is considered that greater fate of test-water concentration on Chlorothalonil is due to hydrolyzing nitrile group under the mild condition and substituting chloro group by some aromatic compounds in test water. 5. Determined logP of Chlorothalonil was 2.80. And determined $LC_{50}$ of Chlorothalonil in time of 24, 48, 72 and 96 hr were 0.1684, 0.1402, 0.1400, 0.1352(mg/l) respectively. And $LC_{50}$ of Carbaryl in above times were 19.918, 18.635, 18.466, 18.12(mg/l) respectively. $LC_{50}$ of BPMC were 10.248, 9.166, 9.087, 8.921(mg/l) respectively. 6. It is suggested that the BCF of Carbamates depend on partition coefficients. But BCF of Chlorothalonil, organochlorine pesticide, would be strongly influenced by steric, electronic effect of substituents than partition coefficient.

  • PDF

Water Quality Management of Simple Piped Water Supply System and Its Satisfaction of the Residents (簡易上水道의 水質管理實態와 給水利用住民의 滿足度)

  • Chae, Han-Uk;Park, Jae-Yong;Moon, Hyo-Jung
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.13-22
    • /
    • 1999
  • For the purpose of inquiring into the actual conditions of water quality management of Simple Piped Water Supply(SPWS) and the satisfaction and attitudes of inhabitants about utilizing water-supply, this research was done through the questionnaires, the investigation of surrounding environment and water quality analysis in the Sangju city, Kyungsang-pookdo during 4 months from March to June, 1998. The fountainhead of SPES using ground water accounted for 65.3%, which was the highest rate in the group. Most of them was at least 10 years in the number of utilization year. 79.6% of them were exposed to many sorts of surrounding pollution origins. The examination of water was performed only through a test about water purification and 24.5% of them disinfection by chlorine also no residual chlorine was detected at all. All the waterworks did not have any education to the managers of water quality and 81.5% of them held physical examination. As a result of the water examination about SPWS, 65.3% of them were found incongruity and the valley and springing water accounted for higher than the underground water in the rate of incongruity. Looking into the details of the result in the water examination, a category of colon bacilli was ranked in the highest rate and the next one was general bacilli, nitric acid nitrogen and turbidity in order. In the satisfaction degree of the water quality, the satisfied accounted for 44.6%, and 29.2% each. Over the state of satisfaction about the ways of water examination, satisfaction accounted for 44.6%, and unsatisfaction 28.3%. Summarizing the result of the above-stated, the state of Water Quality Management of the SPWS was in a poor condition. Thus for the water Quality Management, systematic and scientific water Quality Management mainly by the administrative organization other than voluntary management by the village should be done beyond doubt. Additionally the opinions and demands of inhabitants utilizing the water supply have to be positively reflected in the affairs of water Quality Management so that the distrust of inhabitants to the SPWS should be settled.

  • PDF

Evaluation of fire-proofing performance of reinforced concrete tunnel lining coated by newly developed material (신개발 내화재료에 피복된 철근콘크리트 터널라이닝의 내화성능평가)

  • Park, Hae-Genn;Kim, Jang-Ho Jay
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.329-336
    • /
    • 2008
  • Efficient traffic network is required in urban area for good living condition. However, dense traffic network creates traffic jam and gives bad influences to the ground environment. Therefore, advanced use of underground and tunnel is required. But, in the last 20 years many tunnel fire accidents have occurred all over the world. Increase of tunnels and increase of traffics result in increase of tunnel fire. Tunnel fire creates damage to people and to the tunnel structure. Also, tunnel fire creates a big economical loss. In a mountain tunnel, the stability of the tunnel will not be disturbed by fire although the tunnel lining will get a severe damage. However, in a shield tunnel or immersed tube tunnel, cut and cover tunnel, there is a high possibility that tunnel itself will collapse by fire because their tunnel concrete lining is designed as a structural member. The aim of this experimental research is to verify the fire protection performance of newly developed cementitious material compared with the broadly used existing products in Europe and Japan. For the experiments, the general NATM tunnel concrete linings with the newly developed material were tested using fire loading curve of RABT (Maximum peak temperature is $1,200^{\circ}C$) and RWS (Maximum peak temperature is $1,350^{\circ}C$). From the test results, the newly developed fire protection material applied with 30 mm thickness showed good fire-proofing performance under RABT fire loading.

  • PDF

Runoff Analysis for Weak Rainfall Event in Urban Area Using High-ResolutionSatellite Imagery (고해상도 위성영상을 이용한 도시유역의 소강우 유출해석)

  • Kim, Jin-Young;An, Kyoung-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.6
    • /
    • pp.439-446
    • /
    • 2011
  • In this research, enhanced land-cover classification methods using high-resolution satellite image (HRSI) and GIS in terms of practicality and accuracy was proposed. It aims for understanding non-point pollutant origin/loading, assessment the efficiency of rainfall storage/infiltration facilities and sounds water-environment management. The result of applying enhanced land-cover classification methods to the urban region verifies that roof and road area are including various vegetations such as roof garden, flower bed in the median strip and street tree. This accounts for 3% of total study area, and more importantly it was counted as impervious area by GIS alone or conventional indoor work. The feasibility of the method was assessed by applying to rainfall-runoff analysis for three weak rainfall in the range of 7.1-10.5 mm events in 2000, Chiba, Japan. A good agreement between simulated and observed runoff hydrograph was obtained. In comparison, the hydrograph simulated with land-use parameters by the detailed land-use information of 10m grid had an error between 31%~71%, while enhanced method showed 4% to 29%, and showed the improvement particularly for reproducing observed peak and recession flow rate of hydrograph in weak rainfall condition.