• Title/Summary/Keyword: environment condition

Search Result 6,759, Processing Time 0.035 seconds

Effect of multiple-failure events on accident management strategy for CANDU-6 reactors

  • YU, Seon Oh;KIM, Manwoong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3236-3246
    • /
    • 2021
  • Lessons learned from the Fukushima Daiichi nuclear power plant accident directed that multiple failures should be considered more seriously rather than single failure in the licensing bases and safety cases because attempts to take accident management measures could be unsuccessful under the high radiation environment aggravated by multiple failures, such as complete loss of electric power, uncontrollable loss of coolant inventory, failure of essential safety function recovery. In the case of the complete loss of electric power called station blackout (SBO), if there is no mitigation action for recovering safety functions, the reactor core would be overheated, and severe fuel damage could be anticipated due to the failure of the active heat sink. In such a transient condition at CANDU-6 plants, the seal failure of the primary heat transport (PHT) pumps can facilitate a consequent increase in the fuel sheath temperature and eventually lead to degradation of the fuel integrity. Therefore, it is necessary to specify the regulatory guidelines for multiple failures on a licensing basis so that licensees should prepare the accident management measures to prevent or mitigate accident conditions. In order to explore the efficiency of implementing accident management strategies for CANDU-6 plants, this study proposed a realistic accident analysis approach on the SBO transient with multiple-failure sequences such as seal failure of PHT pumps without operator's recovery actions. In this regard, a comparative study for two PHT pump seal failure modes with and without coolant seal leakage was conducted using a best-estimate code to precisely investigate the behaviors of thermal-hydraulic parameters during transient conditions. Moreover, a sensitivity analysis for different PHT pump seal leakage rates was also carried out to examine the effect of leakage rate on the system responses. This study is expected to provide the technical bases to the accident management strategy for unmitigated transient conditions with multiple failures.

A Study on the Feasibility Assessment for Selecting Recreation Forest Sites: The Case of Gwangju-si in Gyeonggi-do (휴양림 조성 대상지 선정을 위한 타당성 평가 연구 - 경기도 광주시를 중심으로 -)

  • Seo, Jung-young;Yeom, Sung-Jin
    • Journal of Environmental Science International
    • /
    • v.28 no.11
    • /
    • pp.959-969
    • /
    • 2019
  • This study sought to contribute to the revitalization of local economy by developing a natural recreation forest, which is the base of ecotourism recreation, through utilizing forest resources and the natural environment of Gwangju-si. The study conducted a feasibility assessment through on-site surveys such as the suitability of the candidate sites, location analysis, and possibility of damage to the forest, before developing recreation forest sites in Gwangju-si and, based on the result, selected appropriate subject sites. The candidates for this study were 5 forest sites such as one site in the Mokheon-dong area, two in the Docheok-myeon area, and one in the Toechon-myeon area. For this study, the current status of the natural recreation forest was surveyed, its feasibility index and assessment process were investigated, and the local status and related regulations of Gyeonggi-do and Gwangju-si were reviewed. The final subject sites were selected after feasibility assessment utilizing assessment index in order to evaluate the candidate sites. The feasibility assessment was conducted after three separate on-site surveys for each candidate site between October 2018 and January 2019 utilizing "The Feasibility Assessment Criteria for Natural Recreation Forest (Notification 2018-71)" of the Korean Forest Service. The items instrumental to the feasibility assessment were classified into landscape, location, water system, induction of recreation, and development condition; the assessment was made after redefining each item into detailed items. Through this process, the Usan-ri area was selected as the final site for developing natural recreation forest, having obtained more than 100 points according to "The Feasibility Assessment Criteria for Natural Recreation Forest" of the Korean Forest Service. In order to develop natural recreation forest in the Usan-ri area in the future, further discussion is necessary with the relevant departments in consideration of the degree of ecological zoning map.

Response Analysis of MW-Class Floating Offshore Wind Power System using International Standard IEC61400-3-2

  • Yu, Youngjae;Shin, Hyunkyoung
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.454-460
    • /
    • 2020
  • In 2019, the Korean government announced the 3rd Basic Plan for Energy, which included expanding the rate of renewable energy generation by 30-40% by 2040. Hence, offshore wind power generation, which is relatively easy to construct in large areas, should be considered. The East Sea coast of Korea is a sea area where the depth reaches 50 m, which is deeper than the west coast, even though it is only 2.5 km away from the coastline. Therefore, for offshore wind power projects on the East Sea coast, a floating offshore wind power should be considered instead of a fixed one. In this study, a response analysis was performed by applying the analytical conditions of IEC61400-3-2 for the design of floating offshore wind power generation systems. In the newly revised IEC61400-3-2 international standard, design load cases to be considered in floating offshore wind power systems are specified. The upper structure applied to the numerical analysis was a 5-MW-class wind generator developed by the National Renewable Energy Laboratory (NREL), and the marine environment conditions required for the analysis were based on the Ulsan Meteorological Buoy data from the Korea Meteorological Administration. The FAST v8 developed by NREL was used in the coupled analysis. From the simulation, the maximum response of the six degrees-of-freedom motion and the maximum load response of the joint part were compared. Additionally, redundancy was verified under abnormal conditions. The results indicate that the platform has a maximum displacement radius of approximately 40 m under an extreme sea state, and when one mooring line is broken, this distance increased to approximately 565 m. In conclusion, redundancy should be verified to determine the design of floating offshore wind farms or the arrangement of mooring systems.

Adaptation Types of Urban Tissue in Ipjeong-dong Area, Seoul (서울 입정동 일대 도시조직의 적응 유형)

  • Woo, Don-Son;Cho, Yun-O
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.99-106
    • /
    • 2018
  • The purpose of this study is to examine adaptation types of urban tissue in Ipjeong-dong area, Seoul. Ipjeong-dong area has urban tissue those were made during Joseon dynasty and this is remaining even in the present time. This area was originally urban hanok residential districts till late 1950s. However, it has changed into machinery manufacture business area after demolition of Cheonggyechon shantytown. After several workshops and stores moved in this area, manufacturer and merchants required for more spaces due to lack of room for machinery. To place more workshops in the block, lot alteration were happened and accessibility to workshops inside the block were required. Adaptive road network which is main form of adaptative urban tissue were made to adapt in this kind of poor urban condition. To research about adaptive urban tissue making, distribution were explored and comparison tasks between various cadastral map of 1940, 1964, 1970s and 2017 were conducted. From these tasks, certain types of adaptive urban tissues and characteristics of these elements were found. First of all, forms of adaptive road depend on the surrounded environment. Connecting internal building corridor with original road system is categorized as Type A. Altering a portion of the buildings to make adaptive roads is categorized as Type B. Second, there were two types of formation of adaptive road. Type 1 is for adaptive road which is independent gesture from original road network. Type 2 is for adaptive road which is altering the form of original road network by lengthening or connecting two different dead-end roads.

Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings (외기 중 미세먼지의 공동주택 실내 유입에 관한 연구)

  • Bang, Jong-Il;Jo, Seong-Min;Sung, Min-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.

Soil Characterization of the Field where Rice has been Cultivated during Five Years (최근 5년간 벼농사 논의 토양 특성 연구)

  • Cha, Eun-Jin;Lee, Jin-Kyeong;Jang, Min-Ho;Choi, Min-A;Kim, Jae-Hyun;Han, Seung-Je;Park, Jin-Hee;Shin, Chang-Seop
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.8-13
    • /
    • 2021
  • The study for soil has been conducted separately by several areas such as soil mechanics and soil chemistry. Soil is important in terms of prediction of how the plant grow with nutrient requirement. Also, soil is important for machines to work on to solve labor shortage and save farmers from harsh environment during farm work. To meet diverse needs related to soil in agriculture, the soil related study needs to be conducted synthetically. Thus, we tried to obtain the data related to soil chemistry including pH and Electrical Conductivity (EC) with data related to soil mechanics including Cone Index (CI), moisture content, soil classification. Specifically, the condition of the field was set to be cultivated at least for five years continuously at a first step. The soil was taken from 30 sites. CI was obtained using the soil penetrometer and soil classification was conducted using sieve analysis with eight kinds of sieve. The soil was taken on December when is during winter in Korea. There was variation of data including moisture content and CI.

Feeding ratio affects growth, body composition, and blood chemistry of mandarin fish (Siniperca scherzeri) in recirculating aquaculture system

  • Kim, Yi-Oh;Oh, Sung-Yong;Lee, Who-Seung
    • Fisheries and Aquatic Sciences
    • /
    • v.24 no.6
    • /
    • pp.219-227
    • /
    • 2021
  • The effects of various feeding ratios on the growth, body composition, and blood chemistry of the juvenile mandarin fish Siniperca scherzeri (initial body weight 9.6 g) were examined in recirculating freshwater system equipped with 21, 300 L tanks at 20 fish per tank. The triplicate groups of seven feeding ratios treatments were prepared: 100% (control), 95%, 90%, 85%, 80%, 75%, and 70% of satiation. The feed amount of control group was determined by supplying with apparent satiation and then the feed amounts of the other six feeding groups were determined based on the feed amount of the control group. Fish were hand-fed with test diet (55.4% crude protein) for 10 weeks. Weight gain (WG) and specific growth rate of fish fed to 100% satiation were not significantly (p > 0.05) different from those of fish fed to ≥ 80% satiation but were significantly higher than those of fish fed to 75% and 70% satiation. Feed efficiency, protein efficiency ratio, and protein retention of 100% satiation were not significantly different from those of 95% and 90% satiation but were significantly (p <0.05) lower than ≤ 85% satiation. Condition factor, hepatosomatic index, and coefficient variation were not significantly (p > 0.05) affected by feeding ratio. Whole body composition and contents of hematocrit, glutamic oxaloacetic transaminase, glutamic pyruvic transaminase, glucose, total protein, and high-density lipoprotein cholesterol in blood serum were not significantly (p > 0.05) affected by the feeding ratio; however, content of total cholesterol tended to decrease as the feeding ratio decreased. Using broken-line analysis of WG, it was suggested that the optimum feeding ratio of juvenile mandarin fish, ranging from 9.0 g to 37.0 g, appeared to be 87.7% of satiation without growth inhibition.

Effects of soil water content and light intensity on the growth of Molinia japonica in montane wetlands in South Korea

  • Choi, Yu Seong;Park, Hyun Jun;Kim, Jae Geun
    • Journal of Ecology and Environment
    • /
    • v.45 no.1
    • /
    • pp.17-23
    • /
    • 2021
  • Background: Montane wetlands are unique wetland ecosystems with distinct physicochemical characteristics, and Molinia japonica often makes dominant communities in montane wetlands in South Korea. In order to figure out the environmental characteristics of M. japonica habitats and the major factors for the growth of M. japonica, field surveys were conducted in five wetlands from September to October 2019. Also, soil was collected at every quadrats installed in surveyed wetlands to analyze the physicochemical features. Results: The relative coverage of M. japonica was higher in low latitude wetlands than in high latitude. Redundancy analysis showed that soil water content had the strongest effect on the growth of M. japonica (F = 23.0, p < 0.001). Soil water content, loss on ignition, and relative light intensity showed a high correlation with the density (R = 0.568, 0.550, 0.547, respectively, p < 0.01) and the coverage of M. japonica (R = 0.495, 0.385, 0.514, respectively, p < 0.01). Soil water content, loss on ignition, and pH were highly correlated with each other. Conclusions: Molinia japonica lives in acidic wetlands at high altitude in temperate zone of low latitude, with peat layer placed on the floor. Also, M. japonica prefers open spaces to secure enough light for photosynthesis. High shoot production of M. japonica resulted in adding new peat material in every year, and this layer enforces the environmental characteristics of M. japonica habitats. This study may provide insights for further understanding of the method how wetlands maintain acidic condition by itself in montane wetlands in temperate zone.

A Secure Yoking-Proof Protocol Providing Offline Verification (오프라인 검증을 지원하는 안전한 요킹증명 프로토콜)

  • Ham, Hyoungmin
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.2
    • /
    • pp.113-120
    • /
    • 2021
  • RFID (Radio Frequency Identification) yoking authentication provides methods scanning a pair of RFID tags with a reader device and verifying them to ensure the physical proximity of objects. In the first yoking proof protocols, a verifier connected to a reader device online is essential to verify the yoking proof, and this condition limits the environment in which yoking proof can be applied. To solve this limitation, several studies have been conducted on offline yoking proof protocol that does not require the online connection between a reader and a verifier. However, the offline yoking proof protocols do not guarantee the basic requirements of yoking proof, and require relatively more operations on the tag compared to the previous yoking proof protocols. This paper proposes an efficient offline yoking proof protocol that supports offline verification without the need for an online verifier. The proposed protocol provides a secure yoking proof with fewer number of operations than the existing ones, and it also can be extended to the group proof for more than a pair of tags without additional devices. The analysis in this paper shows that the proposed protocol provides offline verification securely and effectively.

Development of Molecular Diagnostic System with High Sensitivity for the Detection of Human Sapovirus from Water Environments

  • Lee, Siwon;Bae, Kyung Seon;Lee, Jin-Young;Joo, Youn-Lee;Kim, Ji-Hae;You, Kyung-A
    • Biomedical Science Letters
    • /
    • v.27 no.1
    • /
    • pp.35-43
    • /
    • 2021
  • Human Sapovirus (HuSaV) is one of the major causes of acute gastroenteritis in humans, and it is used as a molecular diagnostic technique based on polymerase chain reaction (PCR) from humans, food, shellfish, and aquatic environments. In this study, the HuSaV diagnosis technique was used in an aquatic environment where a number of PCR inhibitors are included and pathogens, such as viruses, are estimated to exist at low concentration levels. HuSaV-specific primers are improved to detect 38 strains registered in the National Center for Biotechnology Information (NCBI). The established optimal condition and the composition, including the RT-nested PCR primers and SL® Non-specific reaction inhibitor, were found to have 100 times higher sensitivity based on HuSaV plasmid than the previously reported methods (100 ag based on HuSaV plasmid 1 ng/μL). Through an artificial infection test, the developed method was able to detect at least 1 fg/μL of HuSaV plasmid contaminated with total nucleic acid extracted from groundwater. In addition, RT-nested PCR primer sets for HuSaV detection can react, and a positive control is developed to verify false positives. This study is expected to be used as a HuSaV monitoring method in the future and applied to the safety response to HuSaV from water environments.