• Title/Summary/Keyword: environment condition

Search Result 6,761, Processing Time 0.036 seconds

Estimation of Surface Reflectance by Utilizing Single Visible Reflectance from COMS Meteorological Imager - Analysis of BAOD correction effect - (천리안위성 기상 탑재체의 가시 채널 관측을 이용한 지표면 반사도 산출 - 배경광학두께 보정의 효과 분석 -)

  • Kim, Mijin;Kim, Jhoon;Yoon, Jongmin
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.5
    • /
    • pp.627-639
    • /
    • 2014
  • Accurate correction of surface effect from back scattered solar radiance is one of key issue to retrieve aerosol information from satellite measurements. In this study, two different methods are applied to retrieve surface reflectance by using single visible channel measurement from meteorological imager onboard COMS. The first one is minimum reflectance method, which composes the minimum value among previously measured reflectances at each pixel over a certain search window length. This method assumes that the darkest pixel corresponds to the aerosol-free condition, and deduces surface reflectance by correcting atmospheric scattering from the measured visible reflectance. The second method, named as the "atmospheric correction method" in this study, estimates the result by correcting aerosol and atmospheric scattering with ground-based observation of aerosol optical properties. The purpose of this study is to investigate the retrieval accuracy of the widelyused minimum reflectance method. Also, the retrieval error caused by the loading of background aerosol is mainly estimated. The comparison between surface reflectances retrieved from the two methods shows good agreement with the correlation coefficient of 0.87. However, the results from the minimum reflectance method are slightly overestimated than the values from the atmospheric correction method when surface reflectance is lower than 0.2. The average difference between the two results is 0.012 without the background aerosol correction. By considering the background aerosol effect, however, the difference is reduced to 0.010.

Study on Retardation Effect of a Heavy Metal in Sandy Soils

  • Kim, Dong-Ju;Sung, Baek-Doo
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.06a
    • /
    • pp.43-49
    • /
    • 1998
  • Retardation effect of heavy metals in soils caused by adsorption onto the surfaces of solids particles is well known phenomena. The adsorption of metal ions has been recognized more strong in clay mineral and organic matter contents rather than sands and gravels. In this study, we investigated the retardation effect in two sandy soils by conducting batch and column tests. The column tests were conducted to obtain the relationship between concentration and time known as breakthrough curve (BTC). We applied pulse type injection of ZnCl$_2$solution on the inlet boundary and monitored the effluent concentration at the exit boundary under steady state condition using EC-meter and ICP-AES. Batch test consisted of an equilibrium procedure for fine fractions collected from two sandy soils for various initial ZnCl$_2$concentrations, and analysis of Zn ions in equilibrated solution using ICP-AES. The results of column test showed that i) the peak concentration of Zn analyzed by ICP was far less than that detected by EC-meter for both soils and ii) travel times for peak concentration were more less identical for two different monitoring techniques. The first result can be explained by ion exchange between Zn and other cations initially present in the soil particles since ICP analysis showed a significant amount of Ca, Mg ions in the effluent. From the second result, we found that retardation effect was not present in these soils due to strong cation exchange capacity of Zn ion over other cations since we did not apply a solution containing more adsorptive cations such as Al. The result of batch test also showed high distribution coefficients (K$_{d}$) for two soils supporting the dominant ion exchange phenomena. Based on the retardation factor obtained from the Kd, we predicted the BTC using CDE model and compared with the BTC of Zn concentration obtained from ICP The predicted BTC, however, disagreed with the monitored in terms of travel time and magnitude of the peak concentrations. The only way to describe the prominent decrease of Zn ion was to introduce decay or sink coefficient in the CDE model to account for irreversible decrease of Zn ions in liquid phase.e.

  • PDF

The Estimation of Groundwater Recharge with Spatial-Temporal Variability at the Musimcheon Catchment (시공간적 변동성을 고려한 무심천 유역의 지하수 함양량 추정)

  • Kim Nam-Won;Chung Il-Moon;Won Yoo-Seung;Lee Jeong-Woo;Lee Byung-Ju
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.5
    • /
    • pp.9-19
    • /
    • 2006
  • The accurate estimation of groundwater recharge is important for the proper management of groundwater systems. The widely used techniques of groundwater recharge estimation include water table fluctuation method, baseflow separation method, and annual water balance method. However, these methods can not represent the temporal-spatial variability of recharge resulting from climatic condition, land use, soil storage and hydrogeological heterogeneity because the methods are all based on the lumped concept and local scale problems. Therefore, the objective of this paper is to present an effective method for estimating groundwater recharge with spatial-temporal variability using the SWAT model which can represent the heterogeneity of the watershed. The SWAT model can simulate daily surface runoff, evapotranspiration, soil storage, recharge, and groundwater flow within the watershed. The model was applied to the Musimcheon watershed located in the upstream of Mihocheon watershed. Hydrological components were determined during the period from 2001 to 2004, and the validity of the results was tested by comparing the estimated runoff with the observed runoff at the outlet of the catchment. The results of temporal and spatial variations of groundwater recharge were presented here. This study suggests that variations in recharge can be significantly affected by subbasin slope as well as land use.

Treatment Kinetics of Wastewater and Morphological Characteristics of Biofilm in Upflow Biobead® Process (상향류식 바이오비드 공법을 이용한 오·폐수 처리특성 및 부착 생물막의 형태적 특징)

  • Yum, Kyu-Jin;Lee, Jeong-Hun;Kim, Sun-Mi;Choi, Weon-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.201-212
    • /
    • 2002
  • The objective of this study was to investigate the treatment efficiency, kinetics, and morphological characteristics of biofilm in upflow $Biobead^{(R)}$ process, a kind of biological aerated filter(BAF). The $Biobead^{(R)}$ system showed high removal rates of $COD_{Mn}$(76~83%), $BOD_5$(67~88%) and SS(71~91%) for food wastewater with high salt concentration ($>4,000mg/{\ell}$) under short reaction times(2~3hrs). Even at aerobic condition, the system had high treatment efficiency for both T-N (51~63%) and T-P(62~81%). The removal kinetics of $COD_{Mn}$, $BOD_5$, T-N, T-P, and $Cl^-$ in the $Biobead^{(R)}$ system showed a plug-flow pattern with reaction rate constants($hr^{-1}$) of 0.58, 0.63, 0,30, 0.48, and 0.38 respectively. A backwashing process to remove excess biomass and filtered solids was needed at least once during 22-hour operation at $0.5kg\;BOD\;m^{-3}{\cdot}d^{-1}$ loading. At the higher loading($1.0kg\;BOD\;m^{-3}{\cdot}d^{-1}$) the backwashing interval was shorten by 8 hours. The COD, BOD, T-N, and T-P were removed from 43 to 66% only by aerobic biodegradation. The SS was removed over 70% by the filtering of $Biobead^{(R)}$ media in the treatment system. The first one of three serial Biobead reactors showed the highest removal values for $COD_{\alpha}$(52.3%), $COD_{Mn}$(38.8%), BOD(62.5%), and T-N(40.0%). The SS and T-P had the highest removal values(47.5% and 29.2%) at the second one of the serial reactors. The biofilm had non-homogeneous spatial distribution and the colonies were embedded in the sunk area of the Biobead. The thickness of the biofilm was very thin ($5.0{\sim}29.4{\mu}m$) compared to the biofilm thickness($200{\sim}300{\mu}m$) used in other BAF systems.

Impact Analysis of Tributaries and Simulation of Water Pollution Accident Scenarios in the Water Source Section of Han River Using 3-D Hydrodynamic Model (3차원 수리모델을 이용한 한강 상수원구간 지류영향 분석 및 수질오염사고 시나리오 모의)

  • Kim, Eunjung;Park, Changmin;Na, Mijeong;Park, Hyeon;Kim, Bogsoon
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.4
    • /
    • pp.363-374
    • /
    • 2018
  • The Han River serves as an important water resource for the city of Seoul, Korea and in the neighboring metropolitan areas. From the Paldang dam to the Jamsil submerged weir, the 4 water intake stations that are located for the Seoul metropolitan population were under review in this study. Therefore the water quality management in this section is very important to monitor, analyze and review to rule out any safety concerns. In this study, a 3-D hydrodynamic model, EFDC (Environmental Fluid Dynamics Code), was applied to the downstream of the Paldang Dam in the Han River, which is about 23 km in length, to determine issues related to water resource management. The 3-D grid was composed of 2,168 horizontal grids and three vertical layers. In this case, the hydrodynamic model was calibrated and verified with an observed average daily water surface elevation, water temperature and flow rate data for 3 years (2013~2015). The developed EFDC model proved to reproduce the hydrodynamics of the Han River well. The composition ratios of the noted incoming flows at the monitored intake stations for 3 years and their flow patterns in the river were analyzed using the validated model. It was found that the flow of the Wangsuk Stream depended on the Paldnag dam discharge, and it was noted that the composition ratios of the stream at the intake stations changed accordingly. In a word, the Wangsuk Stream moved mainly along the right bank of the Han River under the condition of a normal dam flow. As can be seen, when the dam discharge rate was low, the incidence of lateral mixing was often seen. The scenario analyses were also conducted to predict the transport of conservative pollutants as in the case of a chemical spill accident. Generally speaking, when scenarios were applied, the arrival time and concentration of pollutants at each intake station was thus predicted.

Restriction of Ca2+ deficiency-like symptoms by co-expressing a Ca2+ transporter and a Ca2+-binding protein in tomato (토마토에서 칼슘수송체와 칼슘결합단백질 공동발현에 의한 칼슘결핍유사증상의 완화)

  • Han, Jeung-Sul;Kang, Ho-Ju;Kim, Chang-Kil
    • Journal of Plant Biotechnology
    • /
    • v.37 no.4
    • /
    • pp.549-555
    • /
    • 2010
  • Here we focused on tip-burn and blossom-end rot (BER) symptoms in the tomato plants expressing the constitutively active form of $Ca^{2+}/H^+$ antiporter (sCAX1) and/or a Ca-binding protein (calreticulin, CRT) genes during their whole growth period. Conclusively we demonstrated that CRT is able to suppress the tip-burn and BER symptoms that were induced by sCAX1. Under poor nutrition condition, tomato plants overexpressing sCAX1 showed severe necrotic collapses in both roots and shoot polar tissues, which are in accordance with $Ca^{2+}$ deficient symptoms frequently observed in an agricultural cultivation of tomato. Reciprocal grafting trials using sCAX1 and wild type plants revealed that the tip-burn symptom by sCAX1 overexpression is not caused by hindrance of $Ca^{2+}$ uptake from soil. We constructed CRT overexpressing transgenic tomatoes, and crossed them with sCAX1 transgenic plants to investigate the effects of CRT on the symptoms of sCAX1 transgenic plants. Co-expression of sCAX1 and CRT significantly suppressed the $Ca^{2+}$ deficient symptoms of sCAX1 transgenic plants. Those results suggest the model that $Ca^{2+}$ homeostasis disturbed by the overexpression of sCAX1 may be suppressed by the co-expression of CRT.

Effect of sampling volume on the breakthrough of charcoal tube during vinyl chloride monomer sampling (공기중 염화비닐단량체의 포집시 공기 포집량이 파과에 미치는 영향)

  • Yoon, Jon Jung;Lim, Nam Gu;Kim, Chi Nyun;Roh, Jaehoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.241-248
    • /
    • 2001
  • The main factors of breakthrough are known to sampling time, flow rate, concentration of the sample, temperature, humidity, and the physical characteristics of the solid sorbent tube. However, no study has been reported the effect of temperature and sampling volume on the breakthrough of acharcoal tube during vinyl chloride monomer (VCM) sampling. The objective of this study is to suggest the optimal sampling condition during VCM sampling based on National Institute for Occupational Safety and Health (NIOSH) method. To evaluate adequate sampling volume for VCM without breakthrough, volume of 1, 2, 3, 4, and 5 L each from VCM of 1, 5, 10, 15, and 20ppm at flow rate of 0.05 L/min were sampled in $22^{\circ}C$ and $40^{\circ}C$. At $22^{\circ}C$, in the case of 1, 5, 10, and 15ppm, VCM was adsorbed completely in first section of charcoal tube regardless of sampling volume. But in 20ppm, detection rates are 99.56% in first section and 0.44% in second section. At $40^{\circ}C$ of 1ppm, VCM was adsorbed completely in first section. In 10, 15, and 20ppm, detection rates of second, third, and forth sections were decreased significantly by reduction of sampling volume. In determination of breakthrough based on NIOSH method, no breakthrough was occurred in 20ppm at $22^{\circ}C$. At $40^{\circ}C$, breakthrough was occurred in 10, 15, and 20ppm when sampling volume was 5L. Although no breakthrough was occurred when sampling volume was 3L. Finally, in environment of temperature around $22^{\circ}C$, breakthrough may not occurred up to 20ppm during sampling for VCM. During sampling for VCM in environment of temperature around $40^{\circ}C$, no breakthrough occurred in 1-5ppm and 10-20ppm when sampling volume is 5L and 3L respectively. This result suggests that the sampling volume should be considered when VCM sampling under hot conditions (> $22^{\circ}C$) by the NIOSH method No. 1007.

  • PDF

Expanding the Substances of Water Quality Standard for the Protection of Human Health Based on Risk Assessment (인체 위해성기반 수질환경기준 항목 확대를 위한 연구)

  • An, Youn-Joo;Nam, Sun-Hwa;Lee, Jae-Kwan
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.1
    • /
    • pp.34-42
    • /
    • 2008
  • Water quality standards (WQS) are mandatory to guarantee the human health and protection of aquatic ecosystems, and maintain the condition of suitable water quality. The present WQS for the protection of human health in Korea contain nine substances (As, Cd, $Cr^{6+}$, CN, Pb, Hg, ABS, organophosphorus compounds and PCBs), but it is insufficient to preserve the human and aquatic ecosystem from a variety of chemicals. Therefore, it is necessary to expand the substance of WQS for the protection of human health. In this study, we chose the 20 chemicals from 43 chemicals of the project entitled 'Development of Integrated Methodology for Evaluation of Water Environment'. The methodology for calculating water quality criteria was amended from the US Environmental Protection Agency (US EPA)'s equation for deriving ambient water quality criteria for the protection of human health. The factors including fish intake, drinking water intake, and human body weight used in the equation reflected Korean situations. The monitoring values were derived from the water quality monitoring data in Korean four main rivers. The orders of priorities of chemicals were evaluated by human health risk assessment, and the proposed WQS was derived by technical and economic analyses. These results were reflected to expand the WQS for the protection of human health.

Effect of Long Day Period Before Short Day treatment on the Dry Matter Production and Flower Quality of Greenhouse-Grown Cut Chrysanthemum cv, Reagan Improved (단일처리전 장일처리 기간이 온실재배 스프레이 절화국의 건물생산과 절화품질에 미치는 영향)

  • 백철기;이정현;안규빈;한태호;정순주
    • Journal of Bio-Environment Control
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • This study was conducted under the condition of greenhouse to investigate the relationships between the period of long day (LD) treatment before short day treatment, the dry matter production and flower quality of cut chrysanthemum (Indicum group) cv. Reagan Improved at Wagenigen University in the Netherlands. Rooted cuttings of chrysanthemum (Indicum group) cv. Reagan Improved were transplanted on 6th, 13th, loth of September and all of them were treated with short-days (SD) on 21th September. The periods from planting until final harvest were 70, 77, 84 days after being planted for 1, 2, and 3 week-LD period, respectively. The time of flower initiation was similar in all treatments. The number of flowers per plant was greater in the plot of 3 week-LD period than that in the plot of 1 or 2 week-LD period. The fresh weight and dry weight of flowers also increased more in the plot of 3 week-LD period than that in the 1 week-LD period by 4g and 0.4g, respectively. The final dry matter production ($g{\cdot}m$^{-2}$ ) was greater in the treatment of 3 week-LD period than 1 or 2week-LD period. In this study, LD period before short day treatment did not affect the time of flower initiation and flower quality. As a result, 3 week-LD period before short day treatment was strongly recommanded for producing high quality cut flowers of greenhouse-grown chrysanthemum.

Optimized Handoff Scheme with Fuzzy logic in Heterogeneous Vehicular Mobile Networks (이종의 차량 모바일 네트워크에서 퍼지 로직을 이용한 최적의 핸드오프 기법)

  • Roh, Youngsam;Jeong, Jongpil
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.1
    • /
    • pp.35-46
    • /
    • 2012
  • The development of wireless communication systems has resulted in the availability of several access technologies at any geographic area, such as 3G networks, wireless local area networks (WLANs) and wireless broadband networks. The development of these technologies is provided for users who have experienced mobile network environments which are slow or fast-movement environment and change distance between the AP(Access Point). This paper describes network performance issues in various environmental changes. Also, Fuzzy logic is applied to evaluate the performance in vehicle networks around users' environmental factors to focusing on the minimizing of transfer time and costs. First, WLAN and 3G networks fixed distance between AP, Second, WLAN and 3G networks random distance between APs, finally above two environmental with vehicle Ad hoc networks is analyzed. These V2I and V2V environmental condition are assumed. Results which based on Fuzzy logic suggest an optimal performance in vehicle network environments according to vehicle speed and distance between APs. Proposed algorithm shows 21% and 13% improvement of networks performance in V2I and V2V environment.