• Title/Summary/Keyword: environment condition

Search Result 6,762, Processing Time 0.03 seconds

Parallel Reservoir Analysis of Drought Period by Water Supply Allocation Method (공급량 배분기법을 이용한 갈수기 병렬저수지 해석)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2006
  • In this study, an optimization technique was developed from the application of allocation rule. The results obtained from the water supply analysis and reliability indices analysis of Andong dam and Imha dam which are consist of parallel reservoir system are summarized as the followings; Allocation rule(C) is effective technique at the parallel reservoir system because results of the water supply analysis, storage analysis and reliability indices analysis is calculated reasonable results. Also, reliability indices analysis results are not sufficient occurrence based reliability or quantity based reliability. Thus reliability indices analysis are need as occurrence based reliability, quantity based reliability vulnerability, resilience, average water supply deficits and average storage. And water supply condition is better varying water supply condition than constant water supply condition.

Condition Analysis of Ecological Planning Elements in Schools (학교시설의 생태계획요소 실태분석에 관한 연구)

  • Kang, Eun-Ju;Cho, Jin-Il
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.17 no.4
    • /
    • pp.3-12
    • /
    • 2010
  • In this paper, a current condition analysis of a certified environmentally-friendly school and a school forest demonstration school was made to understand how they have developed effective ecological environments and examine their specific technical methods for ecological planning. After taking into account the differences and current situations of the two types of schools this paper will present an effective method for the suitable implementation ecological environmental projects in domestic schools.

Practical Applications of Multi-Agent Transformer Condition Monitoring (다수 변압기의 온라인 모니터링을 위한 실제 적용)

  • Yun, Ju-Ho;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.96-99
    • /
    • 2008
  • On-line condition monitoring is a useful tool for maintaining and extending the longevity of power transformers. An intelligent diagnostic system is desirable for operational safety and reliability. Bringing these concepts together results in a powerful support tool for engineers, reducing the volume of data to deal with, and making the data more meaningful. This paper describes how a multi-agent system for diagnosing the cause of transformer partial discharge activity was coupled with a method of UHF partial discharge monitoring, creating an on-line condition monitoring system. The challenges presented by the on-site environment are discussed, along with the implications for the complete system.

  • PDF

Active vibration control of smart composite structures in hygrothermal environment

  • Mahato, P.K.;Maiti, D.K.
    • Structural Engineering and Mechanics
    • /
    • v.44 no.2
    • /
    • pp.127-138
    • /
    • 2012
  • The composite materials may be exposed to environmental (thermal or hygral or both) condition during their service life. The effect of environmental condition is usually adverse from the point of view of design of composite structures. In the present research study the effect of hygrothermal condition on the design of laminated composite structures is investigated. The active fiber composite (AFC) which may be utilized as actuator or sensor is considered in the present analysis. The sensor layer is used to sense the level of response of the composite structures. The sensed voltage is fed back to the actuator through the controller. In this study both displacement and velocity feedback controllers are employed to reduce the response of the composite laminate within acceptable limit. The Newmark direct time integration scheme is employed along with modal superposition method to improve the computational efficiency. It is observed from the numerical study that the laminated composite structures become weak in the presence of hygrothermal load. The response of the structure can be brought to the acceptable level once the AFC layer is activated through the feedback loop.

A Study on the Elasto-Plasticity Behaviour of a Ship's Plate under Thrust According to Boundary Condition (압축력을 받는 선체판의 경계조건에 따른 탄소성거동에 관한 연구)

  • 고재용;박주신;박영현
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2003.05a
    • /
    • pp.153-158
    • /
    • 2003
  • Design of general steel structure had applied and achieve elastic design concept mainly so far. Because elastic design supposes that whole structure complies with elasticity formula as that achieve via allowable stress of material is concept that calculate stress distribution of construction about action external load and estimate load of when the maximum stress reaches equally with allowable stress that is established beforehand by maximum safety load of the structure. But, absence that compose actuality structure by deal with external load increase small success surrender and structure hardness falls and tell structure in limit state finally on the whole as showing complicated conduct by interference between these breakdown at buckling by compression. Examined closely about conduct of place since initial buckling through carbon vocal cords transformation finite element analysis series (ANSYS) that place mending condition supposes case that is boundary condition in this investigation.

  • PDF

Analysis of Marine Leisure base condition for the Archipelago at the Southwest Sea Area (서남권 다도해 해역의 해양레저 기반여건분석)

  • Park Sung-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.30 no.3 s.109
    • /
    • pp.253-258
    • /
    • 2006
  • In this paper, we analyse the marine leisure base condition of the archipelago at the southwest sea area which has the natural advantage for marine leisure. We also discuss how to adapt the yacht business on the above area. At first, we analyse the current situation of the domestic marine leisure and draw up a plan to solve its problem. Finally we apply an environment friendly marina establishment to the archipelago at the southwest sea area and evaluate its validity.

Feasibility study of ground source heat pump system according to the local climate condition (지역 기후 특성에 따른 지열시스템의 도입경제성 차이에 관한 연구)

  • Nam, Yujin
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.127-131
    • /
    • 2014
  • The ground source heat pump (GSHP) system is a kind of the temperature differential energy system using relatively stable underground temperature as heat source of space heating and cooling. This system can achieve higher performance of system than it of conventional air source heat pump systems. However, its superiority of the system performance is different according to installation location or local climate, because the system performance depends on the underground condition which is decided by annual average air temperature. In this study, in order to estimate the feasibility of the ground source heat pump system according to the local climate, numerical simulation was conducted using the ground heat transfer model and the surface heat balance model. The case study was conducted in the condition of Seoul, Daejeon, and Busan, In the result, the heat exchange rate of Busan was 34.33 W/m as the largest in heating season and it of Seoul was 40.61 W/m as the largest in cooling.

The Factors of Choice of Residences of Small Household - Focused on Case of Seoul - (소규모가구의 거주지 설정요인에 관한 연구 - 서울시의 사례를 중심으로 -)

  • Kim, Jin-Soo;Kim, Jin-Mo
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.97-102
    • /
    • 2014
  • This study has an intention of investigating residential present condition of small households, and analysing the factors which have an influence on the choice of residence as a first step of the efficient plan of group residential facility providing a variety of residential present condition. The study defines the meaning of small households on the basis of statistical data that were presented at the National Statistical Office in order to analyse the factors influencing the choice of residence and investigate residential present condition. And the analysis range target is from 20 to 30 aged groups such as university students, social rookie year, and married couples without children. According to the result of analysing residential actual conditions of small households, The choice of residence has various factors. But the study supposes that it reflects three elements of workplace, University and housing price in the choice of residence. So the study investigated the related data.

The Effect of Drawing Conditions on the Tensile Strength of Optical Fiber (광섬유의 인장강도에 미치는 Drawing Condition의 영향)

  • 한택상;최상삼
    • Journal of the Korean Ceramic Society
    • /
    • v.19 no.1
    • /
    • pp.44-50
    • /
    • 1982
  • Drawing optical fibers in a graphite furnace is one of the most convenient and economical means of producing optical fiber. Since the flaw formation on optical fiber is mainly due to dust contaminations during drawing and surface corrosion by water vapor penetration through coating layer, the tensile strength of optical fiber drawn in a graphite furnace is greatly inflenced by the drawing conditions. The important factors found in this investigation were preform treatment (fire polishing), furnace interior environment (dust contamination, inert gas flows), primary coating condition (resin curing temperature, coating materials, method, thickness) and fiber pulling condition (furnace temperature, drawing speed, pulling tension). The tensile strength at optimum drawing conditions turned out to be 5 ~ 6 GPa.

  • PDF

A Study on Thermal Stress in T/G Wall of Containment Building (격납건물 텐던갤러리 벽체의 온도응력에 대한 연구)

  • 김진근;양은익;박영진;송영철;방기성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.193-198
    • /
    • 1998
  • In this study, the change of concrete temperature, strain and thermal stress were measured by using the embedded type concrete gauges in tendon gallery wall of containment building. A finite element analysis was performed to clarify the thermal behavior of concrete. The analytic and test results were investigated to improve the validity of analytic method. According to the test results, concrete temperature, strain and thermal stress were strongly affected by measuring point and environment condition of member. And the thermal stress was developed in the member which was not demoulded at early ages. This is caused by the change of internal temperature and restrained condition. A finite element effectively interpreted the test results by estimating the concrete properties and the site condition.

  • PDF