• Title/Summary/Keyword: environment condition

Search Result 6,762, Processing Time 0.035 seconds

A study for the Improvement of Sanitary Condition in Korean style-restaurant in Seoul city area (I) - Evaluation on sanitation of working environment and facilities for the kitchen- (한식 제공 음식업소의 위생 및 시설 조사 연구 (I) -작업환경 위생 및 조리설비 평가-)

  • Kye, Seung-Hee;Moon, Hyun-Kyung;Chung, Hae-Rang;Hwang, Seong-Hee;Kim, Wu-Seon;Moon, Hae-Yeun
    • Journal of the Korean Society of Food Culture
    • /
    • v.9 no.5
    • /
    • pp.457-465
    • /
    • 1995
  • The purpose of the present study is to identify potentially hazardous factors which can contribute to the outbreak of foodborne disease and to represent more practical management methods in terms of environmental sanitation and facilities for the kitchen. 230 Korean-style restaurants in Seoul were assessed and analyzed by the restaurant total area. Facilities and sanitary check-lists were developed to evaluate the facilities and sanitary conditions of sampled restaurants. The sanitary condition of kitchen, guest room and other area were assessed by the sanitary score. The basic cooking machinery and utensil were properly facilitated but automation machinery were equiped below 10% sampled restaurants. The kitchen area were not properly sufficient to total area. Sanitary condition of kitchen, guest room, cooking appliance and stored foods were evaluated as the unsatisfactory state with potentially hazardous. Concrete guidelines should be made in terms of following item; establishment for the kitchen space expansion, facilities for the improvement of the working environment and sanitary condition of foods cooked. Additionaly, it need to practice the effective education and training program for the foodservice manager and employees.

  • PDF

Water Quality Characteristics and Fish Community of the Gucheon Reservoir and Yeoncho Reservoir in Geoge Island

  • Han, Jeong-Ho;Paek, Woon-Kee;An, Kwang-Guk
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.1
    • /
    • pp.29-45
    • /
    • 2015
  • Water chemistry and fish community, based on fish compositions and ecological characteristics(trophic/tolerance guilds and condition factor), were compared in Gucheon Reservoir($G_cR$) and Yeoncho Reservoir($Y_cR$). Chemical parameters of water quality such as BOD, COD, nutrient(N, P) and suspended solids indicated that water quality was better in the $Y_cR$ than $G_cR$, and the temporal variability in seasonal and interannual patterns were greater in the $Y_cR$. The greater variability was mainly attributed to intense dilutions of reservoir water by Asian monsoon rain during July-August. Fish guild analysis indicated that species diversity was higher in the $G_cR$ than the $Y_cR$, and that the proportion of tolerant and omnivore species were greater in the $Y_cR$. Regression analysis of body weight-total length showed that the regression coefficient(b value) was lower in the $G_cR$(2.15 ~ 2.40) than the $Y_cR$(2.59 ~ 3.14). Condition factor(K) of fish against the total length showed negative slope of Zacco temminckii, Carassius auratus, Pseudorasbora parva and Rhinogobius brunneus population in the $G_cR$, and a positive slope of Carassius auratus and Rhinogobius brunneus population in $Y_cR$. Overall, our data suggest that the growth of the fish populations, based on the length-weight relations and condition factor, reflected the trophic regime of nutrients and organic matter.

A Study for Durability Test of Dynamic Power Cable under Marine Operating Environment Condition (동적 파워 케이블의 해양운용환경 내구성 검증시험에 관한 연구)

  • Shim, Chunsik;Kim, Chulmin;Rho, Yuho;Lee, Jaebok;Chae, Kwangsu;Song, Hacheol;Kim, Hokyeong;Bae, Chulmin;Wi, Sungkuk;Im, Kichen
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.1
    • /
    • pp.49-57
    • /
    • 2021
  • In the production power transmitting of a floating production system like a wind offshore floating, the power cable should be connected from the surface system into the subsea system. The connection between the surface and the subsea system will make the power cable get a dynamic load like current and wave forces. Based on this condition, a dynamic power cable is required to endure external physical force and vibration in the long-term condition. It needs more requirements than static power cable for mechanical fatigue properties to prevent failures during operations in marine environments where the external and internal loads work continuously. As a process to verify, the durability test of dynamic power cables under the marine operation environment condition was carried out by using domestic technology development.

Clothing Microclimate and Subjective Sensations by Wearing Long Johns in Mildly Cold Air (겨울철 실내 온도에서 내복 착용에 따른 의복 기후와 주관적 감각)

  • Kim Myung-Ju;Lee Joo-Young
    • Journal of the Korean Home Economics Association
    • /
    • v.42 no.10 s.200
    • /
    • pp.91-104
    • /
    • 2004
  • The purpose of this study was to examine the differences of clothing microclimates and the subjective sensations according to age, gender and clothing weight for $19^{\circ}C$ air temperature. This study was done to gain fundamental data related to saving heating energy and to improve health through wearing underwear (long johns) in lower indoor temperatures. The subjects were divided into four groups (6 young males, 5 young females, 6 old males, 6 old females), and our experiment consisted of three conditions; the first condition was wearing long underwear in $19^{\circ}C$ air (19CUW condition); the second condition was without wearing long underwear in $19^{\circ}C$ air (19C condition); and the third condition was without wearing underwear in $24^{\circ}C$ air (24C condition). The experiment showed that the clothing microclimate temperature and humidity was the lowest in the 19C condition and the highest in the 24C condition irrespective of age and gender. The clothing microclimate in the 19CUW condition was not significantly distinguishable from the other conditions. Clothing microclimate temperature and humidity when the subjects responded thermal comfort was $28\~34^{\circ}C$ and $15\~40\%$RH without any significant difference according to age and gender. For the thermal sensation, the 24C condition was regarded as the warmest environment by the four groups, and the next preference was the 19CUW condition (p<0.001). Young females and old males showed a tendency to feel colder than young males and old females. For the thermal sensation of hands and feet, the young groups felt the warmest in the 24C condition and the coolest in the 19 C condition (p<0.001). However, old males felt neutral for the foot thermal sensation without any significant difference between the three conditions. Old females felt neutral for both the hands and feet thermal sensations without any significant difference between the three conditions. Thermal preference was the highest in the 24C condition for the 4 groups. In the 19CUW condition, for the thermal preference, most young males and females responded 'No change'; on the other hand, mea of the old responded 'Warmer'(p<0.001). It was the 24C condition that the 4 subject groups felt the most thermally comfortable. In the 19CUW condition, over $80\%$ of responses of each group expressed satisfaction and in the 19C condition, over $80\%$ of responses of each group, except young females, expressed satisfaction. In conclusion, in view of the clothing microclimate and subjective sensations, the 24C condition was the condition that gave subjects the least cold stress and the best subjective preference. However, the 19C condition and the 19CUW condition was not such a cold stress as to give healthy subjects a thermal burden.

The Influence of Dam Weight, Body Condition and Udder Scores on Calf Birth Weight and Preweaning Growth Rates in Beef Cattle

  • Paputungan, U.;Makarechian, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.4
    • /
    • pp.435-439
    • /
    • 2000
  • Records of weight, age, body condition at calving and udder characteristics scores of 425 beef cows and birth weights and periodical weights of their offspring from birth to weaning were analyzed to study the effect of body weight, condition and udder characteristic scores of dams on birth weight and Preweaning growth of their offspring. Dam's body condition (fat reserve) at calving were scored on a scale of 1 to 5 (1=extremely thin and 5=extremely fat) and dam's udder characteristics were scored on a scale of 1 to 7 (l=udder well attached with small teats and 7=at least one quarters not functional). Dams were from three distinct breed groups and were mated in single sire mating groups within each breed group for 45 days. Within each breed group and year, the dams were classified into high, medium and low based on their weights at the time of parturition. The data were analysed using covariance analysis. In general, calves born to heavier dams were heavier at birth and had higher rate of Preweaning growth. The effect of dam's body condition score on the calf birth weight was not significant. However, cows with average body condition score of 2.5 or 3.0 gave birth to calves that had higher pre weaning growth rates up to weaning than those born to calves with higher body condition score. The udder characteristics score did not affect calf birth weight as expected; however, cows with udder score of 3 (udder well attached with large teats) produced calves with higher preweaning growth rate than those with smaller teats. Based on the results, it can be concluded that maintaining animals with average body condition and weight would result in more efficient calf production. In addition, cows with well attached udder and large teats would provide a better maternal environment for Preweaning growth rates of their calves.

Effects of the Hip Internal Rotation Gait on Gluteal and Erector Spinae Muscle Activity (고관절 내회전 보행이 둔부 근육과 척추 기립근의 근활성도에 미치는 영향)

  • Kwon, Oh-Yun;Won, Jong-Hyuck;Oh, Jae-Seop;Lee, Won-Hwee;Kim, Soo-Jung
    • Physical Therapy Korea
    • /
    • v.13 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • The purpose of this study was to identify the effect of the hip internal rotation on gluteal and erector spinae muscle electromyographic (EMG) activity during treadmill walking. Eleven healthy subjects were recruited. All subjects performed treadmill walking while maintaining the hip in neutral position (condition 1) and in internal rotation (condition 2). Surface EMG activity was recorded from four muscles (gluteus maximus (GM), gluteus medius (GMED), tensor fascia latae (TFL), and erector spinae (ES)) and the hip internal rotation angle was measured using a three dimensional motion analysis system. The gait cycle was determined with two foot switches, and stance phase was normalized as 100% stance phase (SP) for each condition using the MatLab 7.0 program. The normalized EMG activities according to the hip rotation (neutral or internal rotation) were compared using a paired t-test. During the entire SP of treadmill walking, the EMG activities of GM in condition 1 were significantly greater than in condition 2 (p<.05). The EMG activities of TFL and ES in condition 2 were significantly greater than in condition 1 (p<.05). The EMG activities of the GMED in condition 1 were significantly greater than in condition 1 (p>.05) except for 80~100% SP. Further studies need randomized control trials regarding the effect of hip internal rotation on the hip and lumbar spine muscle activity. Kinetic variables during gait or going up and down stairs are also needed.

  • PDF

A Simulation Study on the Improvement of Lighting Condition on Sidewalks Considering the Type and Growth of Roadside Trees (가로수의 유형 및 성장을 고려한 보행로 조명환경 개선에 관한 시뮬레이션 연구)

  • Lee, Jong-Sung;Lee, Seok-Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.3
    • /
    • pp.93-103
    • /
    • 2013
  • In recently, a growing concern for the health of urban residents increased interests in a variety of outdoor activities simply be done in terms of cost and time. They are specially interested in low-impact and safe exercises around residential or working area. Walking is the one of easily doing exercise in daytime or nighttime near residential area. The sidewalks of boulevard near the residential area is the best place for exercise because of easy access and the green space with roadside trees. However, if the nighttime is not guaranteed the proper lighting condition, the possibility of exposure to crime and the threat to pedestrian safety can be increased. Because roadside trees are one of the potential obstacle for lighting condition, supplementary lightings are important to mitigate interruption for safety. To meet such a need, the purpose of this study is to propose a simulation approach which improves lighting condition on sidewalks of boulevard with variety of roadside trees. To do so, the simulation approach is applied for analyzing the interrupted condition by classified five standard types of roadside trees considering the growth of them and finding optimal layout of supplementary luminaires by lighting types. The results of this approach shows that it is useful for assessing the safety of pedestrian in nighttime.

Effect of Partial Oxidation of Wood and RDF in a Fluidized Bed (유동상 반응로 조건에서 목재와 RDF 부분 산화의 영향)

  • Kim, Tae-Hyun;Choi, Sang-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.2
    • /
    • pp.23-32
    • /
    • 2008
  • Gasification characteristics in the fluidized bed reactor are essential for the design of a gasification furnace to optimize the operation condition. Moisture content of the solid fuel is one of the important factors to influence directly the gasification characteristics. So it is necessary to investigate the effect of moisture content of solid fuel in partial oxidation condition. Gasification characteristics are investigated with results from thermogravimetric analyzer and lab-scale fluidized bed reactor for wood and RDF samples along with changing moisture contents. Additionally lab-scale fluidized bed reactor was run continuously and gas concentrations at the exit were measured. It is observed that the rate of reaction in partial oxidation condition is between the results from the combustion environment and from the inert condition. Moisture content in a particle slows down the heating rate of a particle. So, reaction is delayed by the moisture content. However, RDF samples those are easy to break-up don't show the effect of moisture content. The result of continuous operation condition shows that proper moisture content promotes gasification because steam from the particles helps gasification of the solid fuel. A simulation to predict the syn-gas composition was conducted by the Aspen Plus process simulator. The cold gas efficiency of the experiment was compared with results from the simulation.

  • PDF

Evaluation on Utilizing Systems of Incineration Heat as Resource cycling Type (자원순환형 소각열 이용시스템에 관한 평가)

  • 정용현
    • Journal of Environmental Science International
    • /
    • v.12 no.4
    • /
    • pp.503-510
    • /
    • 2003
  • How to plan the energy system is one of the keys f3r constructing the Environment -Friendly City. for this reason, a great number of surveys for utilizing unused energy have conducted by a planner. In regard to unused energy, the heat from incineration plants classify as a unused energy having high-exergy-energy. From this point of view, It is studied about the plant systems providing heat to district heating & cooling(D.H.C) and producing electric power. It is divided four system models as system I (10K [kgf/cm$^2$) vapor as outlet of boiler, supply far 10K vapor and return to 60$^{\circ}C$ as supply condition of district heating), system II (30 K vapor as outlet of boiler, supply for 5t vapor and return to 60f as supply condition of district heating), system 111 (30 K vapor as outlet of boiler, supply for 85$^{\circ}C$ hot water and return to 60$^{\circ}C$ as supply condition of district heating), system IV (30 K vapor as outlet of boiler, supply for 47$^{\circ}C$ hot water and return to 40t as supply condition of district heating). The results from the upper condition of four system, System II got a proper on economical benefits and system IV calculated as benefiting on energy saving effects, and suggest indifference curve as the total evaluation method of both economical benefits and energy saving.

Study on the selection of TBM in consideration of field conditions (시공여건을 반영한 TBM선정 방법에 대한 연구)

  • Oh, Joon-Geun;Sagong, Myung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.125-133
    • /
    • 2014
  • In this study, TBM selection methods to meet soil and site conditions were presented. Factors and excavation equipment affecting TBM selection by soil and environmental condition were selected and classified. Weights between equipment and influencing factors selected were calculated by applying the AHP (Analytic Hierarchy Process) method. The results of the analysis influence factors, Ground condition was a major factor in objective factors and strength was a major factor in the hard condition of criteria factors and water pressure was a major factor in the soft ground condition of criteria factors. In Environment condition, existence of adjacent structures was evaluated more important than existence of feasible site. Lastly, Adequacy was verified through the deduction of results that coincide with input equipment by applying derived weights to actual site conditions.