• 제목/요약/키워드: envelopes

검색결과 274건 처리시간 0.024초

경골어류 잉어과 3종의 수정란 난막 미세구조 비교 (Comparative Ultrastructure of the Fertilized Egg Envelope in Three Species, Cyprinidae, Teleost)

  • 김동희;류동석;등영건
    • Applied Microscopy
    • /
    • 제28권2호
    • /
    • pp.237-253
    • /
    • 1998
  • The structures of the fertilizedegg envelope in threespecies of cyprinidae, leoparddanio (Brachydanio frankei), cherry barb (Barbustitteya) and white cloudmountain fish (Tanichthys albonubes) were investigated by light and electron microscopy. The fertilized eggs of all three species have colorless, transparent, spherical and non-floted type. The egg envelopes have a single micropylewhich is thought to the pathway of sperm in the area of the animal pole. Also, an outer layersof both cherry barband white cloud mountain fish areadhesive types, but in that of leoparddanio has non-adhesivetype. In leopard danio, an outer surface ofegg envelope is covered by mushroom-likestructure, that of cherry barb is arranged by button-like structure, and that of white cloud mountain fish isarranged by rod-likestructure. Inboth leopard danioand cherrybarb, the eggenvelopes consist of three distinct layers; an outer layer, a middle layer and an inner layer, and that of white cloud mountain fish hastwo layers. An innerlayer of egg envelopein leopard danio consist of 10 layers, cherry barb has 8 layers, and white cloud mountain fish has $5\sim6$ layers.

  • PDF

알고리듬 변화에 따른 직/간접 조명시스템에 대한 디밍제어 효과분석 (Analysis on Dimming Control Effect by Algorithm Variation for Direct/Indirect Lighting in a Small Office)

  • 김수영
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.36-48
    • /
    • 2008
  • This study examines the influence of control algorithms on dimming performance to determine appropriate control setting when direct/indirect lighting is controlled by a daylight dimming system. Computer simulation were performed for a small office with double skin envelope under various daylight conditions. A retractable fabric shading and Venetian blind were applied for internal and external envelopes under three CIE standard sky conditions. Unshielded and partially-shielded photosensors were used, and three control algorithms were applied for the sensors. In general, dimming level was too excessive due to the direct impact of light from lighting fixture to the photosensor. Providing insufficient lighting output, the unshielded photosensor completely failed to secure required illuminance under any daylight condition. When a partially-shielded photosensor was applied under clear sky, three setting points functioned effectively. Less sensitivity for the partially-shielded photosensor was effective to control the dimming system optimally with reasonable energy saving. However, the daylight dimming control system for direct/indirect lighting does not appear to be energy effective when photosensors without enough shielded area is installed on ceiling where light from fixtures reaches directly.

Electrochromic 창호 적용시 지역별 건물 냉난방 에너지 소비량 절감성능 (Performance Evaluation of Electrochromic Window System by Different Orientations and Locations in Korea)

  • 신재윤;채영태
    • 한국태양에너지학회 논문집
    • /
    • 제38권5호
    • /
    • pp.75-84
    • /
    • 2018
  • The most crucial point of reducing building energy is application of high performance envelope. The amount of heat exchange through window is highest in comparison of other envelopes so that heat exchange through window influence directly with building energy consumption. The window energy performance can be define with thermal, leakage and optical performance. In previous study we can confirmed that not only thermal performance but also optical performance are considered, 11% to 15% of building energy consumption can be reduced. Smart window system has potential of energy saving so that many industry field use smart window system including architectural area and these aspect causes smart window market continuous growth year by year. In this study, building energy consumption has been analyzed which consist of smart window that dynamically control optical states. The consideration of standard commercial building model for research, the reference medium size commercial building model of DOE (Department Of Energy, USA) has been used. The building energy simulation result of 4 axis in 8 regions in Korea shows 8% to 22% reduction of building energy consumption by application of smart window system.

Variation in wind load and flow of a low-rise building during progressive damage scenario

  • Elshaer, Ahmed;Bitsuamlak, Girma;Abdallah, Hadil
    • Wind and Structures
    • /
    • 제28권6호
    • /
    • pp.389-404
    • /
    • 2019
  • In coastal regions, it is common to witness significant damages on low-rise buildings caused by hurricanes and other extreme wind events. These damages start at high pressure zones or weak building components, and then cascade to other building parts. The state-of-the-art in experimental and numerical aerodynamic load evaluation is to assume buildings with intact envelopes where wind acts only on the external walls and correct for internal pressure through separate aerodynamic studies. This approach fails to explain the effect of openings on (i) the external pressure, (ii) internal partition walls; and (iii) the load sharing between internal and external walls. During extreme events, non-structural components (e.g., windows, doors or rooftiles) could fail allowing the wind flow to enter the building, which can subject the internal walls to lateral loads that potentially can exceed their load capacities. Internal walls are typically designed for lower capacities compared to external walls. In the present work, an anticipated damage development scenario is modelled for a four-story building with a stepped gable roof. LES is used to examine the change in the internal and external wind flows for different level of assumed damages (starting from an intact building up to a case with failure in most windows and doors are observed). This study demonstrates that damages in non-structural components can increase the wind risk on the structural elements due to changes in the loading patterns. It also highlights the load sharing mechanisms in low rise buildings.

사질토 지반에 위치한 해상풍력발전기 석션기초의 복합하중에 대한 안전성 평가 (Safety Evaluation of the Combined Load for Offshore Wind Turbine Suction Foundation Installed on Sandy Soil)

  • 박정선
    • 한국해안·해양공학회논문집
    • /
    • 제33권5호
    • /
    • pp.195-202
    • /
    • 2021
  • 해상풍력발전기는 바람 및 파도, 구조물 자중에 의해 수직-수평-모멘트의 복합하중을 받는다. 본 연구에서는 유한요소해석으로 사질토 지반에 설치된 해상풍력발전기 석션기초의 복합하중에 대한 지지력을 산정하였다. 또한 복합하중이 작용하는 중의 석션기초 주변 지반의 응력상태를 상세하게 분석하였다. 최종적으로 유한요소해석 결과를 토대로 수평 및 모멘트 지지력 산정식과 복합하중에 대한 안전성을 평가하는 지지력 포락선 식을 제안하였다.

The Six Dimensions of Resident Satisfaction and Their Impact on Word-of-Mouth (WOM) Intention in a Continuing Care Retirement Community (CCRC): A Case Study

  • Lee, Ji-Eun
    • 아태비즈니스연구
    • /
    • 제11권4호
    • /
    • pp.49-63
    • /
    • 2020
  • Purpose - This study aims to assess six aspects of resident satisfaction (satisfaction with room, home, social interaction, meals service, staff care, and resident involvement) and to identify the most influential aspect of satisfaction upon word-of-mouth (WOM) intention in a continuing care retirement community (CCRC). Design/methodology/approach - A total of 293 paper survey questionnaires with a cover letter and postage paid envelopes were mailed to the CCRC residents. To test reliability and validity of the multidimensional resident satisfaction, exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were used. Then, the structural equation modeling technique (SEM) was applied to test causal relationship between resident satisfaction and WOM intention. Multiple regression was used to identify the most influential aspect of resident satisfaction on WOM intention in the CCRC. Findings - The results of EFA and CFA on the 157 responses received out of the total 293 surveys indicated that six dimensions of resident satisfaction were statistically distinct. Among the six dimensions, satisfaction with resident involvement, social interaction, and staff care significantly influenced their WOM intention. Furthermore, the most influential aspect of satisfaction upon WOM intention was resident involvement. Research implications or Originality - This study empirically tested the six dimensions of CCRC resident satisfaction, and identified resident involvement as the most influential factor upon WOM intention in a CCRC where WOM intentions plays a crucial role during the selection process of prospective residents.

Strengthening of deficient RC joints with diagonally placed external C-FRP ropes

  • Karayannis, Chris G.;Golias, Emmanouil
    • Earthquakes and Structures
    • /
    • 제20권1호
    • /
    • pp.123-132
    • /
    • 2021
  • Deficient beam-column joints of reinforced concrete (RC) structures designed to older practices and codes often lead to destructive local or global failures. A strengthening technique for these joints based on the use of the new and innovative Carbon-FRP (C-FRP) ropes is presented and investigated. The C-FRP ropes are diagonally placed in superficial notches on the two sides of the joint. Two full scale external substandard joint subassemblages with the same characteristics, one unstrengthened and one strengthened with diagonally applied C-FRP ropes, are constructed and tested in cyclic loading. Special attention has been given to the elaboration of the acquired test measurements. The extracted conclusions are based on the comparative study of the hysteretic responses of the specimens, the observed maximum load envelopes, the comparisons of the joint body shear deformations as measured using diagonally mounted LVTDs, the calculated nominal principal stresses developed in the joint regions, the assessed joint damage as expressed by the damage index by Park and Ang and finally the calculated values of the equivalent damping ratio. From these comparisons it is concluded that application of diagonally mounted C-FRP ropes on the two sides of the joint body of exterior connections is an efficient easy-to-apply technique for the strengthening of substandard RC joints.

국내 표준계사의 냉난방부하 특성 연구 (A Study on the Characteristics of Heating and Cooling Loads of Standard Chicken Houses in South Korea)

  • 권영철
    • 대한건축학회논문집:구조계
    • /
    • 제35권10호
    • /
    • pp.235-243
    • /
    • 2019
  • In South Korea, millions of poultry have died due to repeated heat waves every year. The purpose of this study is to analyze the characteristics of heating and cooling loads of chicken houses in Korea and to present an effective insulation and ventilation measures to minimize the damage of poultry due to summer heat wave and to save energy in chicken houses in winter. The heating and cooling loads of standard chicken house were calculated. As a result of the calculation of maximum heating load based on the minimum ventilation rate in winter, the outdoor air temperature requiring heating was $6{\sim}7^{\circ}C$ to keep the indoor air temperature of chicken houses as $24^{\circ}C$. The peak cooling load of chicken houses was mostly taken by the heat generated by chickens and the heat gain due to ventilation. The heat gain through building envelopes was as small as neglectable. Most of chicken houses is usually cooled by gigantic forced ventilation in summer in Korea. When the chicken houses are cooled by electric cooling machine such as cooler or air conditioner, it is more effective to keep minimum ventilation rate to reduce the maximum cooling load. To lower the temperature of supplying water to cooling pad, it is recommended to use the underground water below 10 meters from the ground if there is abundant underground water.

New records of the genus Cyanobium and Cyanobium gracile (Synechococcales, Cyanophyceae) in Korean freshwater

  • Kwon, Dae Ryul;Jo, Bok Yeon;Jang, Seok Won;Lee, Chang Soo;Nam, Seung Won
    • 환경생물
    • /
    • 제39권1호
    • /
    • pp.32-38
    • /
    • 2021
  • Cyanobium is a genus of picoprokaryotic cyanophytes, which includes species worldwide. The present study investigated the morphology, ultrastructure, and molecular phylogeny of the unrecorded genus Cyanobium Rippka & Cohen-Bazire 1983 and species Cyanobium gracile Rippka & Cohen-Bazire 1983. A C. gracile culture from a freshwater sample collected from the Adongji pond was established by single-cell isolation. Morphological data were analyzed using light and transmission electron microscopy. C. gracile lives as solitary cells without gelatinous envelopes and is ovate, oval, or shortly rod-shaped. Thylakoids are laid along the cell walls, with three thylakoid membranes parallel to each other. Nucleoplasm was observed in the center of the cell. Molecular phylogeny performed with data from 16S small subunit ribosomal DNA gene (SSU rDNA) sequences showed that the three strains of C. gracile, including the type strain (PCC6307) and a newly recorded strain (Adong101619), formed a distinct clade with a high supporting value (maximum-likelihood=100, pp=1.00). Based on morphology and molecular data, we report the newly recorded C. gracile in Korea.

Investigation of the effects due to a permeable double skin façade on the overall aerodynamics of a high-rise building

  • Pomaranzi, Giulia;Pasqualotto, Giada;Zassso, Alberto
    • Wind and Structures
    • /
    • 제35권3호
    • /
    • pp.213-227
    • /
    • 2022
  • The design of a building is a complex process that encompasses different fields: one of the most relevant is nowadays the energetic one, which has led to the introduction of new typologies of building envelopes. Among them, the Permeable Double Skin Façades (PDSF) are capable to reduce the solar impact and so to improve the energetic performances of the building. However, the aerodynamic characterization of a building with a PDSF is still little investigated in the current literature. The present paper proposes an experimental study to highlight the modifications induced by the outer porous façade in the aerodynamics of a building. A dedicated wind tunnel study is conducted on a rigid model of a prismatic high-rise building, where different façade configurations are tested. Specifically, the single-layer façade is compared to two PDSFs, the former realized with perforated metal and the latter with expanded metal. Outcomes of the tests allow estimating the cladding loads for all the configurations, quantifying the shielding effects ascribable to the porous layers that are translated in a significant reduction of the design pressure that could be up to 50%. Moreover, the impact of the PDSFs on the vortex shedding is investigated, suggesting the capability of the façade to suppress the generation of synchronised vortices and so mitigate the structural response of the building.