• 제목/요약/키워드: entrainment flow rate ratio

검색결과 15건 처리시간 0.019초

사각 천장형 루버 디퓨저의 토출 각도에 따른 실내유동에 관한 연구 (Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser)

  • 장헌덕;이대희;이진호
    • 대한기계학회논문집B
    • /
    • 제36권7호
    • /
    • pp.683-687
    • /
    • 2012
  • 본 연구는 CFD 해석을 이용하여 사각 천장형 루버 디퓨저의 토출각도와 토출 유량에 따른 실내 공기유동 특성에 관한 것이다. CFD 툴은 상용프로그램인 ANSYS 13.0의 CFX를 이용하였다. 연구에 사용된 디퓨저는 적은 유량에서도 충분한 도달거리를 확보할 수 있도록 모델링하였으며, 실내 크기는 $6{\times}6{\times}2.7m$로 디퓨저의 대각선 방향으로 원형 배기구를 모델링 하였다. 토출 공기의 체적유량은 5.1CMM, 7.4CMM이며, 디퓨저의 토출각도를 $30^{\circ}$에서부터 $60^{\circ}$까지 $10^{\circ}$씩 변화하여 실내의 유동특성에 대하여 고찰하였다.

The Characteristic Modes and Structures of Bluff-Body Stabilized Flames in Supersonic Coflow Air

  • Kim, Ji-Ho;Yoon, Young-Bin;Park, Chul-Woung;Hahn, Jae-Won
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권3호
    • /
    • pp.386-397
    • /
    • 2012
  • The stability and structure of bluff-body stabilized hydrogen flames were investigated numerically and experimentally. The velocity of coflowing air was varied from subsonic velocity to a supersonic velocity of Mach 1.8. OH PLIF images and Schlieren images were used for analysis. Flame regimes were used to classify the characteristic flame modes according to the variation of the fuel-air velocity ratio, into jet-like flame, central-jet-dominated flame, and recirculation zone flame. Stability curves were drawn to find the blowout regimes and to show the improvement in flame stability with increasing lip thickness of the fuel tube, which acts as a bluff-body. These curves collapse to a single line when the blowout curves are normalized by the size of the bluff-body. The variation of flame length with the increase in air flow rate was also investigated. In the subsonic coflow condition, the flame length decreased significantly, but in the supersonic coflow condition, the flame length increased slowly and finally reached a near-constant value. This phenomenon is attributed to the air-entrainment of subsonic flow and the compressibility effect of supersonic flow. The closed-tip recirculation zone flames in supersonic coflow had a reacting core in the partially premixed zone, where the fuel jet lost its momentum due to the high-pressure zone and followed the recirculation zone; this behavior resulted in the long characteristic time for the fuel-air mixing.

다중효용 담수설비용 열압축기의 디퓨져 입구부 형상에 관한 연구 (A Study on the Diffuser Inlet Shape of Thermocompressor for MED Desalination Plant)

  • 김창복;송영호;김경근;박기태;정한식;최두열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.869-876
    • /
    • 2008
  • A thermocompressor is the equipment which compresses a vapor to a desired discharge pressure. Since it was first used as the evacuation pump for a surface condenser, it has been widely adopted for energy saving systems due to its high working confidence. In the present study, the geometrical analysis of the shape between the jet nozzle and the diffuser inlet, the drag force was calculated by means of the integrated equation of motion and the computational fluid dynamic (CFD) package called FLUENT. The computer simulations were performed to investigate the effects by the various suction flow rates, the distance from jet nozzle outlet to the diffuser inlet and the dimensions of the diffuser inlet section through the iterative calculation. In addition, the results from the CFD analysis on the thermocompressor and the experiments were compared for the verification of the CFD results. In the case of a jet nozzle, the results from the CFD analysis showed a good agreement with the experimental results. Furthermore, in this study, a special attention was paid on the performance of the thermocompressor by varying the diffuser convergence angle of $0.0^{\circ}$, $0.5^{\circ}$, $1.0^{\circ}$, $2.0^{\circ}$, $3.5^{\circ}$ and $4.5^{\circ}$. With the increase of the diffuser convergence angle. the suction capacity was improved up to the degree of $1.0^{\circ}$ while it was decreased over the degree of $1.0^{\circ}$.

수중초음속제트의 불안정성에 대한 실험적 고찰 (Experimental Observation of Instability of Supersonic Submerged Jets)

  • 정재권;이대훈;차홍석;박승오;권세진
    • 한국추진공학회지
    • /
    • 제6권2호
    • /
    • pp.45-52
    • /
    • 2002
  • 2차원 수중 초음속 제트의 구조 및 유동 불안정성에 대한 실험적 연구를 수행하였다. 제트의 구조 및 시간에 따른 변화를 관찰하기 위하여 고속 디지털 카메라 촬영과 정압을 측정하였다. 공기 유량의 변화에 따른 제트의 구조를 초고속 촬영하여 이로부터 얻어진 장면에서 확산각을 구했다. 일련의 제트의 주기적인 특성에 따른 구조를 관찰하였고 불안정성의 초당 주기 발생 횟수가 5-6회 정도로 측정되었다. 세 가지 특성 길이 $L_1$, $L_2$, $L_3$를 정의하였다. $L_1$은 불안정적 주기가 발생할 경우 최대제트의 폭 스케일, $L_2$는 2차적인 유동이 유입되는 곳의 제트의 폭 스케일, $L_3$는 노즐 출구로부터 2차적으로 유도된 유동이 유임되는 곳까지의 길이다. $L_1$/$L_2$는 전압 즉, 탱크 압력이 증가함에 따라 감소하는 경향성을 가지고 있고 $L_3$는 전압이 증가함에 따라 증가하는 경향성을 띄었다. 시간에 따른 정압 변화를 측정하였으며 FFT결과를 통해서 불안정성으로 인해 발생하는 주파수와 유사한 값인 5Hz에서 고유진동이 발생하는 것을 확인하였다.

가로흐름 수역으로 방출되는 2차원 표면온배수 수치모형 비교연구 (A Comparative Study of Two-Dimensional Numerical Models for Surface Discharge of Heated Water into Crossflow Field)

  • 이남주;최흥식;이길성
    • 한국해안해양공학회지
    • /
    • 제6권1호
    • /
    • pp.40-50
    • /
    • 1994
  • 가로흐름이 존재하는 천해역으로 방출되는 표면온배수에 의한 온도장의 정확한 예측을 위한 근해역 2차원 수치모형을 개발하였다. 개발된 모형은 4-방정식 난류모델로서 열적 시간상수에 대한 정보를 얻을 수 없는 2-방정식 난류모델의 단점을 극복하기 위하여 변동온도 자승 평균항 및 그것의 감쇠율에 대한 전달방정식을 2-방정식 모델의 전달방정식에 추가한 모델이다. 또한, 부력생성항 및 난류 열플럭스항을 도입하여 연직방향 확산현상을 고려하고자 하였다. 개발된 수치모형을 간단한 단면을 갖는 개수로 정상류의 경우에 대하여 적용하였으며, 그 결과를 기존의 실험결과 및 2-방정식 난류모델을 사용한 수치계산결과와 비교하였다. 4-방정식 모형에 의한 계산결과가 2-방정식 모형보다 실험결과와 잘 일치하였으며, 제트 포획 및 안정화 영역에서 온배수의 물리적 특성을 잘 재현하였다.

  • PDF