• Title/Summary/Keyword: enhanced dynamic wedge

Search Result 17, Processing Time 0.023 seconds

Estimated Risk of Radiation Induced Contra Lateral Breast Cancer Following Chest Wall Irradiation by Conformal Wedge Field and Forward Intensity Modulated Radiotherapy Technique for Post-Mastectomy Breast Cancer Patients

  • Athiyaman, Hemalatha;M, Athiyaman;Chougule, Arun;Kumar, HS
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.12
    • /
    • pp.5107-5111
    • /
    • 2016
  • Background: Epidemiological studies have indicated an increasing incidence of radiation induced secondary cancer (SC) in breast cancer patients after radiotherapy (RT), most commonly in the contra-lateral breast (CLB). The present study was conducted to estimate the SC risk in the CLB following 3D conformal radiotherapy techniques (3DCRT) including wedge field and forward intensity modulated radiotherapy (fIMRT) based on the organ equivalent dose (OED). Material and Methods: RT plans treating the chest wall with conformal wedge field and fIMRT plans were created for 30 breast cancer patients. The risks of radiation induced cancer were estimated for the CLB using dose-response models: a linear model, a linear-plateau model and a bell-shaped model with full dose response accounting for fractionated RT on the basis of OED. Results: The plans were found to be ranked quite differently according to the choice of model; calculations based on a linear dose response model fIMRT predict statistically significant lower risk compared to the enhanced dynamic wedge (EDW) technique (p-0.0089) and a non-significant difference between fIMRT and physical wedge (PW) techniques (p-0.054). The widely used plateau dose response model based estimation showed significantly lower SC risk associated with fIMRT technique compared to both wedge field techniques (fIMRT vs EDW p-0.013, fIMRT vs PW p-0.04). The full dose response model showed a non-significant difference between all three techniques in the view of second CLB cancer. Finally the bell shaped model predicted interestingly that PW is associated with significantly higher risk compared to both fIMRT and EDW techniques (fIMRT vs PW p-0.0003, EDW vs PW p-0.0032). Conclusion: In conclusion, the SC risk estimations of the CLB revealed that there is a clear relation between risk associated with wedge field and fIMRT technique depending on the choice of model selected for risk comparison.

고선량율 근접조사치료용 이리듐-192 방사성동위원소의 교정방법 비교 ${\cdot}$ 연구

  • Heo, Hyeon-Do;Park, Seong-Yong;Lee, Re-Na;Sin, Dong-O;Gwon, Su-Il;No, Jun-Gyu;Choe, Jin-Ho
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.78-80
    • /
    • 2004
  • 본 연구에서는 쐐기형태의 선량분포를 구현할 수 있도록 고안된 미국 Varian사 동적쐐기(EDW ; Enhanced Dynamic Wedge)의 표면선량(surface dose)과 주변선량(peripheral dose) 특성을 분석하였다. 쐐기각도 15${\circ}$, 30${\circ}$, 45${\circ}$, 50${\circ}$를 대상으로 금속쐐기를 사용했을 경우와 동적쐐기를 사용했을 경우에 대해 해당 선량특성을 비교, 분석하였다. 표면선량 측정 결과, 동적쐐기가 금속쐐기보다 더 높은 선량 분포를 보였으며, 주변선량의 경우, 금속쐐기가 동적쐐기보다 더 높은 선량분포를 보였다. 이는 금속쐐기의 빔 필터링에 의한 빔 경화(hardening) 현상과 광자선과의 산란 현상에 기인한 결과로 방사선치료 계획 시 동적쐐기의 적용에 있어 고려해야 할 주요 특성이라 사료된다.

  • PDF

Experimental investigation of dynamic trim control devices in fast speed vessel (고속선의 트림제어 장치가 항주 자세 및 저항 성능에 미치는 영향)

  • Seo, Kwang-Cheol;Gopakumar, Nithin;Atlar, Mehmet
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.137-142
    • /
    • 2013
  • The displacement Deep-V catamaran concept was developed in Newcastle University(UNEW) through development of the systematic Deep-V catamaran series. One of the most important Deep-V catamaran launched to date is Newcastle University's own multi-purpose research vessel, The Princess Royal. The vessel was launched in 2011 and enhanced the Deep-V catamaran concept further with the successful adoption of a novel anti-slamming bulbous bow and tunnel stern for improved efficiency. It was however identified that the vessel has substantial amount of dynamic trim that limited the visibility of the captain. The dynamic trim also increased the wave-making resistance thereby preventing the vessel from attaining its maximum speed in certain sea states. This paper therefore presents the application of devices such as Trim Tabs, Interceptors, Transom Wedges and Integrated Transom Wedges-Tabs to control the dynamic trim and improvement of fuel efficiency of the vessel. All of these energy saving devices were fitted into a model for tests in Newcastle University's Towing Tank. Model test verification confirmed that the optimum appendage was the interceptors, they produced a 5% power saving and 1.2 degree trim reduction at 15 knots, and investigations of full scale trials will be scheduled with and without application of device to compare the improvement of performance.

Evaluation of Contralateral Breast Surface Dose in FIF (Field In Field) Tangential Irradiation Technique for Patients Undergone Breast Conservative Surgery (보존적 유방절제 환자의 방사선치료 시 종속조사면 병합방법에 따른 반대편 유방의 표면선량평가)

  • Park, Byung-Moon;Bang, Dong-Wan;Bae, Yong-Ki;Lee, Jeong-Woo;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.401-406
    • /
    • 2008
  • The aim of this study is to evaluate contra-lateral breast (CLB) surface dose in Field-in-Field (FIF) technique for breast conserving surgery patients. For evaluation of surface dose in FIF technique, we have compared with other techniques, which were open fields (Open), metal wedge (MW), and enhanced dynamic wedge (EDW) techniques under same geometrical condition and prescribed dose. The three dimensional treatment planning system was used for dose optimization. For the verification of dose calculation, measurements using MOSFET detectors with Anderson Rando phantom were performed. The measured points for four different techniques were at the depth of 0cm (epidermis) and 0.5cm bolus (dermis), and spacing toward 2cm, 4cm, 6cm, 8cm, 10cm apart from the edge of tangential medial beam. The dose calculations were done in 0.25cm grid resolution by modified Batho method for inhomogeneity correction. In the planning results, the surface doses were differentiated in the range of $19.6{\sim}36.9%$, $33.2{\sim}138.2%$ for MW, $1.0{\sim}7.9%$, $1.6{\sim}37.4%$ for EDW, and for FIF at the depth of epidermis and dermis as compared to Open respectively. In the measurements, the surface doses were differentiated in the range of $11.1{\sim}71%$, $22.9{\sim}161%$ for MW, $4.1{\sim}15.5%$, $8.2{\sim}37.9%$ for EDW, and 4.9% for FIF at the depth of epidermis and dermis as compared to Open respectively. The surface doses were considered as underestimating in the planning calculation as compared to the measurement with MOSFET detectors. Was concluded as the lowest one among the techniques, even if it was compared with Open method. Our conclusion could be stated that the FIF technique could make the optimum dose distribution in Breast target, while effectively reduce the probability of secondary carcinogenesis due to undesirable scattered radiation to contra-lateral breast.

  • PDF

Clinical and Radiological Features of Diffuse Lacrimal Gland Enlargement: Comparisons among Various Etiologies in 91 Biopsy-Confirmed Patients

  • Sae Rom Chung;Gye Jung Kim;Young Jun Choi;Kyung-Ja Cho;Chong Hyun Suh;Soo Chin Kim;Jung Hwan Baek;Jeong Hyun Lee;Min Kyu Yang;Ho-Seok Sa
    • Korean Journal of Radiology
    • /
    • v.23 no.10
    • /
    • pp.976-985
    • /
    • 2022
  • Objective: To compare the clinical and radiological features of various etiologies of chronic diffuse lacrimal gland enlargement. Materials and Methods: We retrospectively reviewed 91 consecutive patients who underwent surgical biopsy for chronic diffuse lacrimal gland enlargement and were diagnosed with non-specific dacryoadenitis (DA) (n = 42), immunoglobulin G4-related dacryoadenitis (IgG4-RD) (n = 33), and lymphoma (n = 16). Data on patient demographics, clinical presentation, and CT imaging findings (n = 73) and MRI (n = 43) were collected. The following radiologic features of lacrimal gland enlargement were evaluated: size, unilaterality, wedge sign, angle with the orbital wall, heterogeneity, signal intensity, degree of enhancement, patterns of dynamic contrast-enhanced, and apparent diffusion coefficient value. Radiological features outside the lacrimal glands, such as extra-lacrimal orbital involvement and extra-orbital head and neck involvement, were also evaluated. The clinical and radiological findings were compared among the three diseases. Results: Compared to the DA and IgG4-RD groups, the lymphoma group was significantly older (mean 59.9 vs. 46.0 and 49.4 years, respectively; p = 0.001) and had a higher frequency of unilateral involvement (62.5% vs. 31.0% and 15.2%, respectively; p = 0.004). Compared to the IgG4-RD and lymphoma groups, the DA group had significantly smaller lacrimal glands (2.3 vs. 2.8 and 3.3 cm, respectively; p < 0.001) and a lower proportion of cases with a wedge sign (54.8% vs. 84.8% and 87.5%, respectively; p = 0.005). The IgG4-RD group showed more frequent involvement of the extra-orbital head and neck structures, including the infraorbital nerve (36.4%), paranasal sinus (72.7%), and salivary gland (58.6%) compared to the DA and lymphoma groups (4.8%-28.6%) (all p < 0.005). Conclusion: Patient age, unilaterality, lacrimal gland size, wedge sign, and extra-orbital head and neck involvement differed significantly different between lymphoma, DA, and IgG4-RD. Our results will be useful for the differential diagnosis and proper management of chronic lacrimal gland enlargement.

Customer Acceptance Procedure for Clinac (21EX-Platinum)

  • Hong, Dong-Ki;Lee, Woo-Seok;Kwon, Kyung-Tae;Park, Kwang-Ho;Kim, Chung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.43-61
    • /
    • 2004
  • Purpose : For qualify improvement in radiotherapy, it is important to set up and evaluate equipment (linac) accurately. In addition, technicians are needed to be fully aware of the equipment's detailed quality and its manual. Therefore, the result of ATP is evaluated and introduced, in order that the technicians are skilled by participating in quality assurance (QA) and understanding the quality of the equipment before clinical use. Method and Material : QA for LINAC 21EX (Varian, US) was done with suppliers its procedure was divided into radiation survey, mechanical test, radiation isocenter test, bean performance, dosimetry, and enhanced dynamic wedge and using X-omat film (Kodak), multidata, densitometer, and electrometer. QA of MLC (Millennium, 120 leaf) attached to LINAC and EPID (Portal vision) were done separately. Result : The leakage dose by survey meter was below the tolerance. In mechanical test, collimater, gantry, and couch rotation were less than 1mm, and the angles were ${\pm}0.1^{\circ}$ for digital and ${\pm}0.5^{\circ}$ for mechanical. The alignment test of the light field and crosshair were evaluated less than 1mm. The (a)symmetrical jaw field was less than ${\pm}0.5mm$. The radiation isocenter test using X-mat film was less than 1mm. The consistency of light field and radiation field was less than ${\pm}0.1mm$. PDD for photon energy was less than ${\pm}1\%$ and for electron energy of $90\%,\;80\%,\;50\%,\;and\;30\%$ were evaluated within the tolerance. Flatness for photon and electron energy was evaluated $2.3\%$ (tolerance $3\%$) and $3\%$ (tolerance $4.5\%$), respectively, and symmetry was $0.45\%$ (tolerance $2\%$) and $0.3\%$ (tolerance $2\%$), respectively. Dosimetry test for short term, MU setting, rep rate, and dose rate accuracy of photon and electron energy was within the tolerance depending on energy, MU, and gantry angle. Conclusion : Accuracy and safety for clinical use of Clinac 21EX was verified through customer acceptance procedure and the quality of the equipment was found out. These can reduce the difficulties in using the equipment. Furthermore, it is useful for clinically treatment of patients by technicians' active participations.

  • PDF

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF