• Title/Summary/Keyword: engineering technique

Search Result 22,457, Processing Time 0.044 seconds

A practical subcritical rod worth measurement technique based on the improved neutron source multiplication method

  • Jiahe Bai;Chenghui Wan;Ser Gi Hong;Hongchun Wu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1398-1406
    • /
    • 2024
  • The control rod worth is a key safety parameter required to be measured in commercial pressurized water reactors (PWRs). Conventionally, the control rod worth is measured after reaching the critical state, which occupies the considerable time in the zero-power physics test. In this study, an efficient control-rod worth measurement technique has been proposed based on the improved neutron-source multiplication method, which can be implemented with the source-range detector count rates in the subcritical states. Moreover, the noise reduction technique has been adopted to smooth the large fluctuation existing in the original signals. In order to verify the engineering performance of the proposed measurement technique, the measured source-range detector count rates during the rod withdrawal process before reaching critical state in a CNP1000 reactor have been employed. It demonstrated that almost all estimated results of control rod worth satisfy the engineering acceptance criteria, except one control rod with the relative difference over 10 %, which indicates the capability of the proposed method in estimating control rod worth.

Development, validation and implementation of multiple radioactive particle tracking technique

  • Mehul S. Vesvikar;Thaar M. Aljuwaya;Mahmoud M. Taha;Muthanna H. Al-Dahhan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4213-4227
    • /
    • 2023
  • Computer Automated Radioactive Particle Tracking (CARPT) technique has been successfully utilized to measure the velocity profiles and mixing parameters in different multiphase flow systems where a single radioactive tracer is used to track the tagged phase. However, many industrial processes use a wide range of particles with different physical properties where solid particles could vary in size, shape and density. For application in such systems, the capability of current single tracer CARPT can be advanced to track more than one particle simultaneously. Tracking multiple particles will thus enable to track the motion of particles of different size shape and density, determine segregation of particles and probing particle interactions. In this work, a newly developed Multiple Radioactive Particle Tracking technique (M-RPT) used to track two different radioactive tracers is demonstrated. The M-RPT electronics was developed that can differentiate between gamma counts obtained from the different radioactive tracers on the basis of their gamma energy peak. The M-RPT technique was validated by tracking two stationary and moving particles (Sc-46 and Co-60) simultaneously. Finally, M-RPT was successfully implemented to track two phases, solid and liquid, simultaneously in three phase slurry bubble column reactors.

CONSERVATIVE OVERSET MESH TECHNIQUE ON 2-D UNSTRUCTURED MESHES (이차원 비정렬 격자계에서의 보존적 중첩 격자 기법)

  • Jung, M.S.;Kwon, O.J.;Kang, H.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.27-32
    • /
    • 2008
  • In the present study, a conservative overset mesh technique has been developed on 2-D unstructured meshes. A new domain connection technique between independent mesh blocks was proposed to satisfy the conservation of mass, momentum, or energy in entire computational domain. The present technique was applied to several classical computational problems to validate the superiority of the conservative method to the non-conservative method.

  • PDF

CONSERVATIVE OVERSET MESH TECHNIQUE ON 2-D UNSTRUCTURED MESHES (이차원 비정렬 격자계에서의 보존적 중첩 격자 기법)

  • Jung, M.S.;Kwon, O.J.;Kang, H.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.27-32
    • /
    • 2008
  • In the present study, a conservative overset mesh technique has been developed on 2-D unstructured meshes. A new domain connection technique between independent mesh blocks was proposed to satisfy the conservation of mass, momentum, or energy in entire computational domain. The present technique was applied to several classical computational problems to validate the superiority of the conservative method to the non-conservative method.

  • PDF

Analyses of requirements for Network Security Technology

  • Kim, Jung-Tae
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.1
    • /
    • pp.64-67
    • /
    • 2007
  • IT industry strategy trend and home network security technology is presented. First, we consider the development strategy to improve next generation IT industry. Second, we have analyzed the technique for implementing home network. Last, we have analyzed the technique to security home network field.

Accuracy Validation of Urinary Flowmetry Technique Based on Pressure Measurement (수압 측정에 기반하는 요류검사의 정확도 검증)

  • Choi, Sung-Soo;Lee, In-Kwang;Kim, Kun-Jin;Kang, Seung-Bum;Park, Kyung-Soon;Lee, Tae-Soo;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.3
    • /
    • pp.198-204
    • /
    • 2008
  • Uroflowmetry is a non-invasive clinical test useful for screening benign prostatic hyperplasia(BPH) common in the aged men. The current standard way to obtain the urinary flow rate is to continuously acquire the urine weight signal proportional to volume over time. The present study proposed an alternative technique measuring pressure to overcome noise problems present in the standard weight measuring technique. Experiments were performed to simultaneously acquire both weight and pressure changes during urination of 9 normal men. Noise components were separated from volume signals converted from both weight and pressure signals based on the polynomial signal model. Signal-to-noise ratio was defined as the ratio of the energies between signal and noise components of the measured volume changes, which was 8.5 times larger in the pressure measuring technique, implying that cleaner signal could be obtained, more immune to noisy environments. When four important diagnostic parameters were estimated, excellent correlation coefficients higher than 0.99 were resulted with mean relative errors less than 5%. Therefore, the present pressure measurement seemed valid as an alternative technique for uroflowmetry.

A review of the application of acoustic emission technique in engineering

  • Gholizadeh, S.;Leman, Z.;Baharudin, B.T.H.T.
    • Structural Engineering and Mechanics
    • /
    • v.54 no.6
    • /
    • pp.1075-1095
    • /
    • 2015
  • The use of acoustic emission (AE) technique for detecting and monitoring damages and the progress on damages in different structures is widely used and has earned a reputation as one of the most reliable and well-established technique in non-destructive testing (NDT). Acoustic Emission is a very efficient and effective technology used for fracture behavior and fatigue detection in metals, fiberglass, wood, composites, ceramics, concrete and plastics. It can also be used for detecting faults and pressure leaks in vessels, tanks, pipes, as well as for monitoring the progression of corrosion in welding. This paper reviews major research developments over the past few years in application of acoustic emission in numerous engineering fields, including manufacturing, civil, aerospace and material engineering.

Synthesis of four-bar linkage motion generation using optimization algorithms

  • Phukaokaew, Wisanu;Sleesongsom, Suwin;Panagant, Natee;Bureerat, Sujin
    • Advances in Computational Design
    • /
    • v.4 no.3
    • /
    • pp.197-210
    • /
    • 2019
  • Motion generation of a four-bar linkage is a type of mechanism synthesis that has a wide range of applications such as a pick-and-place operation in manufacturing. In this research, the use of meta-heuristics for motion generation of a four-bar linkage is demonstrated. Three problems of motion generation were posed as a constrained optimization probably using the weighted sum technique to handle two types of tracking errors. A simple penalty function technique was used to deal with design constraints while three meta-heuristics including differential evolution (DE), self-adaptive differential evolution (JADE) and teaching learning based optimization (TLBO) were employed to solve the problems. Comparative results and the effect of the constraint handling technique are illustrated and discussed.

Fast Response Technique 2 Quadrant DC Motor Speed Control

  • W. Piyarat;V. Tipsuwanporn;W. Sawangsinkasikit;Lee, M. lajindarairerk;P. Thepsatorn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.244-247
    • /
    • 1999
  • This paper presents a methodology of the technique for controlling DC motor drive by implementation of 2-quadrant operating mode which can ensure the torque controlling and speed with response time less than 2 seconds at all loading conditions. By implementation of BRM technique, energy is fed with definite values of BRM 256 bits, with different patterns of high accuracy, and fixing scan time at 0.667 ms, the ripple is less than 1%, thus high efficiency can be achieved, from the consequence of the accuracy of energy feeding at low current. The stability of the whole system can be determined from circle criterion by root locus method . The instant reverse direction of rotation can be done by decreasing the energy to the lowest level while motor is running with no load and variable load at the speed about 100-120 rpm and 50-60 rpm.

  • PDF

Surface Plasmon Resonance Immunosensor for Detection of Legionella pneumophila

  • Oh, Byung-Keun;Lee, Woochang;Bae, Young-Min;Lee, Won-Hong;Park, Jeong-Woo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.2
    • /
    • pp.112-116
    • /
    • 2003
  • An immunosensor based on surface plasmon resonance (SPR) onto a protein G layer by Self-assembly technique was developed for detection of Legionella pneumophila. The protein G layer by self-assembly technique was fabricated on a gold (Au) surface by adsorbing the 11-mercaptoundecanoic acid (MUA) and an activation process for the chemical binding of the free amino (-NH$_2$) of protein G and 11-(MUA) using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDAC) in series. The formation of the protein G layer by self-assembly technique on the Au Substrate and the binding of the antibody and antigen in series were confirmed by SPR spectroscopy. The Surface topographies of the fabricated thin films on an Au substrate were also analyzed by using an atomic force microscope (AFM). Consequently, an immunosensor for the detection of L. pneumophila using SPR was developed with a detection limit of up to 10$^2$CFU per mL.