Material Characteristics of White Wares from Yeongdong Province, Gangwon-do: Gangneung and Donghae Kiln Sites (강원 영동지역 백자의 재료과학적 특성 연구: 강릉 남양리 백자가마터와 동해 발한동2(사문동) 가마터를 중심으로)

  • Lee, Byeong Hoon;So, Myoung-Gi
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.181-192
    • /
    • 2015
  • This study aims to examine production technique of twelve white wares from the Gangneung Namyang-ri and Donghae Balhan-dong2(Samun-dong) kiln sites, Kangwon Province and characteristics of the used materials, and to find a correlation among materials of the excavated white wares. X-ray fluorescence sequential spectroscopy(XRF), X-ray diffraction(XRD), Dilatometer and Inductively coupled plasma mass spectrometry(ICP-MS), Inductively coupled plasma automic emission spectrometer(ICP-AES) were applied to determine the chemical composition, crystalline phase of samples, firing temperatures, trace elements and rare earth elements. When analyzing body crystalline phases of the white wares using the XRD method, quartz and mullite were extracted from all the samples. Though firing temperature of each sample was different, they were mostly fired at a temperature below $1200^{\circ}C$. Analyzing the excavated white wares using the Seger formula, compositional properties of white wares in Gangneung Namyang-ri kiln showed diffrently from the Donghae Balhan-dong2(Samun-dong) kiln. The body of white wares from Gangneung Namyang-ri kiln have higher raito of $RO_2$ and $RO+R_2O$ than of white wares from Donghae Balhan-dong2(Samun-dong) kiln site. The white wares from Gangneung Namyang-ri kiln and Donghae Balhan-dong2(Samun-dong) kiln were made of host rocks of the different geological origin, according to the result of rare earth elements analysis.

A Study on the Spatial Distribution of Medical Waste Generation and Treatment in Korea (한국의 의료폐기물 발생 및 처리의 공간적 분포에 관한 연구)

  • Oh, Se-Eun;Lee, Jinheon;Ahn, Hoki;Kim, Ki-Youn;Park, Seokhwan;Ha, Kwonchul;Ji, Kyunghee;Hwang, Sungho;Yoon, Oh-Sub;Hong, Young-Seoub;Lee, Eunil;Kim, Pangyi;Lee, Kyoung-Mu
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.6
    • /
    • pp.449-457
    • /
    • 2015
  • Objectives: In Korea, the system of management of medical waste largely relies on the incineration method. Our study aimed to identify any regional imbalances between the generation and treatment of medical waste, and provide reference data for future policy in Korea. Methods: We analyzed data on the amount of medical waste from 2,000 hospitals in 2012, 2013, and 2014 obtained from the Korea Environment Corporation. In the Arc GIS program (version 10.2.3), the addresses of hospitals and incinerators were transformed into map coordinates. The amount of waste generated by each hospital and the amount incinerated were represented by density and size of a triangle symbol, respectively. Results: As of 2014, the total amount of medical waste from the top 2,000 hospitals was 136,073 tons, out of which about half (49%) was generated in the capital area. Eleven incineration companies (three in the capital area, two in the Chungcheong Provinces area, one in the Jeolla Provinces area, and five in the Gyeongsang Provinces area) treated this waste. For the years 2012, 2013, and 2014, about 60% of the medical waste generated from the hospitals in the capital area was treated within the capital area and about 40% was transported to other areas, especially the Gyeongsang Provinces area, for treatment. On the other hand, about 90% of the medical waste incinerated in the capital area originated from the capital area. Conclusion: Our results suggest a spatial imbalance between the generation and treatment of medical waste in Korea and warrants multilateral policies, including the expansion of on-site treatment, strengthening regulation of the containment of medical wastes, promoting reductions in medical waste and more.

Study on the Hygenic Water Quality in Imha Dam (임하댐의 위생학적 수질조사 연구)

  • 이희무
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.1
    • /
    • pp.25-34
    • /
    • 1995
  • A Study on environmental Investigation in Imha Dam for the finding the degree of water quality and heavy metals was carried out at 4 sampling station during the period from August 15, 1993 to May 7, 1994. The results were as follows. 1. The ranges of values of pH for water were st. 1-7.56, st.2-7.77, st.3-7.9, st.4-7,7 on the average. Total average of pH values were 7.56-7.9 2. The ranges of values of DO for water were st.1-8.71($mg/{\ell}$), st.2-8.64($mg/{\ell}$), st.3-10. 25($mg/{\ell}$), st.4-9.01($mg/{\ell}$) on the average. Total average of DO of values were 8.64-10.25($mg/{\ell}$). 3. The ranges of values of BOD for water were st.1-1.1($mg/{\ell}$), st.2-1.0($mg/{\ell}$), st.3-0 86($mg/{\ell}$), st.4-0.99($mg/{\ell}$) on the average. Total average of BOD of values were 0.86-1.1($mg/{\ell}$). 4. The ranges of values of COD for water were st.1-1.12($mg/{\ell}$), st.2-1.4($mg/{\ell}$), st.3-0 98($mg/{\ell}$), st.4-1.46($mg/{\ell}$) on the average. Total average of COD of values were 0.98-1.46($mg/{\ell}$). 5, The ranges of values of T- N for water were st.1-0.36($mg/{\ell}$), st.2-0.49($mg/{\ell}$), st.3-0 23($mg/{\ell}$), st.4-0.83($mg/{\ell}$) on the average. Total average of T-N of values were 0.23-0.83($mg/{\ell}$). 6. The ranges of values of T-P for water were st.1-0.053($mg/{\ell}$), st.2-0.06($mg/{\ell}$), st.3-0.02($mg/{\ell}$), st.4-0.07($mg/{\ell}$) on the average. Total average of T-P of values were 0.02-0.07($mg/{\ell}$). 7. In the E. soli group distribution were counted st.1-1130, st.2-1113, st.3-152.3, st.4-1253 by the MPN test. Total distribution of E. soil group were 152.3-1253. 8. The concentration of heavy metals of Cu, Mn, Pb, Zn were measured st.1-0.59, 0.18, 0 04, 74.6( ${\mu}g/{\ell}$), st.2-0.39,0.29,0.03, 54.3(${\mu}g/{\ell}$), st.3-0.1,0.3, ND, 8(${\mu}g/{\ell}$), st.4-0.96, 0 26,0.23,45.6(${\mu}g/{\ell}$) on the average. Cd, Hg, Cr were not detected in the sampling site.

  • PDF

The Ages of Fault Activities of the Ilkwang Fault in Southeastern Korea, Revealed by Classification of Geomorphic Surfaces and Trench Survey

  • Ho, Chang;Ree, Jin-Han;Joo, Byung-Chan
    • The Korean Journal of Quaternary Research
    • /
    • v.18 no.2 s.23
    • /
    • pp.1-2
    • /
    • 2004
  • The Ilkwang Fault is NNE-striking, elongated 40 Km between Ulsan and Haendae-ku, Busan in southeastem part of the Korean Peninsula(Kim, D.H. et al., 1989; Kim, J.S. et al., 2003). This paper is mainly concemed about the ages of the fault activities especially in the Quatemary, infered from classification of geomorphic surface and trench excavation for the construction of Singori nuclear power plant. The geomorphi surfaces are classified into the Beach and the Alluvial plain, the 10 m a.s.l. Marine terrace, the 20 m a.s.l. Marine terrace, the Reworked surface of 45 m a.s.l. Marine terrace and the Low relief erosional surface, from lower to higher altitude. The Beach and the Alluvial plain are elongated to the Holocene terrace(ist terrace, choi, 2003). The 10 m a.s.l. Marine terrace is correlated to 2nd terrace (MIS 5em 125 Ka. y. B.P., Choi, 1998). The 45 m a.s.l. Marine terace is correlated to the Lower marine terrace (MIS 7,220 Ka. y. B.P., Choi, 2003 or MIS 9,320 y. B.P.) to the Gwanganri terrace(Penultimate interglacial age, 200-200 Ka. Y. B.P., Oh, 1981). The Low relief erosional surface is distributed coastal side, the Reworked surface of 45 m a.s.l. Marine terrace inland side by the Ilkwang Fault Line as the boundary line. But the former is above 10 m higher in relative height than the latter. The 20 m a.s.l. Marine terrace on the elongation line of the Ilkwang Fault reveals no dislocation. A site was trenched on the straight contract line with $N30^{\circ}$ E-striking between the 10 m a.s.l. Marine terrace and the 20 m a.s.l. Marine terrace. Fault line or dislocation was not observable in the trench excavation. Accordingly, the straight contact line is inferred as the ancient shoreline of the 10 m a.s.l. Marine terrace. The Ages of the Fault activities are inferred after the formation of the Ichonri Formation - before the formation of the 45 m a.s.l. Marine terrace (220 Ka. y. B.P. or 320 Ka. y. B.P.). The Low relief erosional surface was an island above the sea-level during the formation of the 45 m a.s.l. Marine terrace in the paleogeography.

  • PDF

Enhancement of photoluminescence and electrical properties of Ga doped ZnO thin film grown on $\alpha$-$Al_2O_3$(0001) single crystal substrate by RE magnetron sputtering through rapid thermal annealing (RF 마그네트론 스퍼터링 법으로 사파이어 기판 위에 성장시킨 ZnO: Ga 박막의 RTA 처리에 따른 photoluminescence 특성변화)

  • Cho, Jung;Na, Jong-Bum;Oh, Min-Seok;Yoon, Ki-Hyun;Jung, Hyung-Jin;Choi, Won-Guk
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.335-340
    • /
    • 2001
  • $Ga_2O_3$(1 wt%)-doped ZnO(GZO) thin films were grown on ${\alpha}-Al_2O_3$ (0001) by rf magnetron sputtering at $510^{\circ}C$, whose crystal structure was polycrystalline. As-grown GZO thin film shows poor electrical properties and photoluminescence (PL) spectra. To improve these properties, GZO thin films were annealed at 800-$900^{\circ}C$ in $N_2$atmosphere for 3 min. After the rapid thermal annealing(RTA), deep defect-level emission disappears and near-band emission is greatly enhanced. Annealed GZO thin films show very low resisitivity of $2.6\times10^{-4}\Omega$/cm with $3.9\times10^{20}/\textrm{cm}^3$ carrier concentration and exceptionally high mobility of 60 $\textrm{cm}^2$/V.s. These improved physical properties are explained in terms of translation of doped-Ga atoms from interstitial to substitutional site.

  • PDF

Compressive Strength and Chloride Permeability of High Strength Concrete according to the Variety of Mineral Admixtures (광물질혼화재 종류별 고강도콘크리트의 압축강도 및 촉진 염소이온침투 특성)

  • Moon Han-Young;Kim Byoung-Kwon
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.407-414
    • /
    • 2004
  • The purpose of this study is to evaluate the ability to resist chloride ions penetration of the concrete structure under marine environment in south-east asia especially. In this study, high strength concrete(HSC) with various combination of ordinary portland cement(OPC), blast-furnace slag(SG) and silica fume(SF) are cured 23 and $35^{\circ}C$ considering the site weather, and are cured in water for 3, 7 or 56 days respectively. And to investigate the fundamental properties and the resistance of chloride penetration of various HSC, setting time, slump flow, compressive strength, void and ASTM C 1202 test were conducted. Test results show that the compressive strength of HSC is similar regardless of SG replacement ratio and total charge passed of chloride is the smallest at 40% replacement of SG. The compressive strength of G4FS HSC is, besides, outstandingly high at early age compare with other HSC, but the compressive strength of G4F HSC, which is vary according to curing temperature and condition, most high at the age after 7 days. Total passed charge of HSC get larger in the order G4FS

Experimental Study on the Cracking Loads of LB-DECKs with Varied Cross-Section Details (단면 상세가 변화된 LB-DECK의 균열하중에 대한 실험적 연구)

  • Youn, Seok-Goo;Cho, Gyu-Dae
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.657-665
    • /
    • 2011
  • LB-DECK, a precast concrete panel type, is a permanent concrete deck form used as a formwork for cast-in-place concrete pouring at bridge construction site. LB-DECK consists of 60 mm thick concrete slab and 125 mm height Lattice-girders partly embedded in the concrete slab. These decks have been applied to the bridges, which girder spacings are short enough to resist longitudinal cracking caused by construction loads. This paper presents experimental research work conducted to evaluate the cracking load of LB-DECKs designed for long span bridge decks. Twenty four non-composite beams and four composite beams are fabricated considering three design variables of thickness of concrete slab, height of lattice-girder, and diameter of top-bar. Static loads controlled by displacements are applied to test beams to obtain cracking and ultimate loads. Vertical displacements at the center of beams, strains of top-bar, crack propagation in concrete slab, and final failure modes are carefully monitored. The obtained cracking loads are compared to the analytical results obtained by elastic analyses. Long-term analyses using age-adjusted effective modulus method (AEMM) are also conducted to investigate the effects of concrete shrinkage on the cracking loads. Based on the test results, the tensile strength and the design details of LB-DECKs are discussed to prevent longitudinal cracking of long span bridge decks.

Estimation of Earth Pressures Acting on Box Structures Buried in Ground (지중에 매설된 박스구조물에 작용하는 토압 산정)

  • Hong, Won-Pyo;Yun, Jung-Mann;Song, Young-Suk
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.2
    • /
    • pp.23-33
    • /
    • 2015
  • The earth pressure acting on underground structure was measured by application of the instrumentation system in the subway construction site constructed by the method of cut-and-cover tunnel. The measured earth pressure was compared with the earth pressure obtained from the existed theoretical equation, and the actual earth pressure diagram acting on the underground structure was investigated. As a result of investigation, the vertical earth pressure is mainly affected by the embankment height, and the lateral earth pressure is significantly affected by whether the existence of earth retaining structures or not. The measured vertical earth pressure is very similar to the theoretical earth pressure proposed by Bierbaumer. The measured lateral earth pressure is closed to the active earth pressure proposed by Rankine rather than the earth pressure at rest. The coefficient of earth pressure in soil deposit layer is about 0.35, and the coefficient in soft rock deposit layer is about 0.21. For design and construction the underground structures, therefore, it is reasonable estimation that the lateral earth pressure acting on structures installed in soil deposit layers is an average value between active earth pressure and earth pressure at rest. In rock deposit layers, the lateral earth pressure acting on structure is an active earth pressure only.

An Experimental Study on the Performance and Field Application of Low Noise Beam-slab Formwork using Table Type Multi-stage Drop System (테이블형 다단 드롭 시스템을 이용한 저소음 보-슬래브 거푸집의 구성부재 성능 및 현장적용에 관한 실험적 연구)

  • Ryu, Hwa-Sung;Jeong, Woo-Jin;Kim, Deuck-Mo;Song, Seong-Yong;Shin, Sang-Heon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.4
    • /
    • pp.349-360
    • /
    • 2017
  • In concrete construction work, formwork is an important process that accounts for 10% of the total construction cost. Recent buildings are becoming bigger and higher. In order to maximize the efficiency and safety of this formwork, the system of formworking has been systematized. However, the human accidents and the noise complaints arise from dismantling processes frequently occur. In order to solve these problems, most of them are dependent on foreign technology, but they do not take into consideration the conditions of domestic construction site. In this study, we developed a table type multi-drop system form for a slab and beam which can improve the process, safety and reduction of disassembly noise, and evaluated the physical properties of the main members which are used in the system. The results of this study show that there is sufficient strength to be used as a slab and a laying material for both a yoke beam and a supporting post. The noise level is improved compared to existing method.

An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old (20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.539-547
    • /
    • 2019
  • Recently, the international community signed a climate change agreement to prevent global warming. Yet currently, the fossil fuels have been widely used in to supply building energy for cooling and heating. The Green Building certification (G-SEED), an energy efficiency rating for new or existing buildings requires that buildings meet certain conditions. Insulation is used as a building material to reduce the energy supply to buildings and to improve the thermal insulation, and it accounts for more than 90% of the total heat resistance provided by the building surface components that meet the energy-saving design standards of new buildings. In this investigation, a performance evaluation study was conducted through an experimental study by directly extracting the foam polystyrene insulation on-site during the remodeling of a building that was in the range of 22~38 years old. Through tests, it was found that the thermal conductivity of the extrusion method insulation (XPS) was reduced by 48% and the compressive strength of XPS decreased by 36% compared to KS M 3808, which is the initial quality standard. For bead method insulation (EPS) with a thickness of 50mm, the thermal conductivity, the compressive strength, and flexural failure load were similar to the initial quality standard. Therefore, in the calculation of the primary energy requirement per unit area per year, the performance of bead method insulation can be estimated simply by considering the thickness of the insulation, while a correction factor that considers its performance deterioration should be applied when extrusion method insulation is used.