• Title/Summary/Keyword: engineering room

Search Result 4,561, Processing Time 0.033 seconds

A study on the food clean room system observing the regulations of HACCP (HACCP의 환경 최적화를 위한 식품 클린룸 설계에 관한 연구)

  • Won, Young-Jae;Suh, Kee-Won
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.520-526
    • /
    • 2009
  • This study proposed the optimum design values for the biological clean room system observing the regulations of Hazard Analysis Critical Control Point (HACCP). Even though the standard for industrial clean room system has been well established, the basis for biological food clean room system is the first stage. In order to prevent the contaminations in advance for food storages, processes, and distributions, the criterion of Hazard Analysis Critical Control Point is positively required. This study also suggested the possible ways of how to avoid the hazardous contaminations.

  • PDF

Design of Semiconducting Gas Sensors for Room-Temperature Operation

  • Song, Young Geun;Kim, Gwang Su;Ju, Byeong-Kwon;Kang, Chong-Yun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • Gas sensors that operate at room temperature have been extensively studied because of sensor stability, lift time, and power consumption. To design effective room-temperature gas sensors, various nanostructures, such as nanoparticles, nanotubes, nanodomes, or nanofibers, are utilized because of their large-surface-to-volume ratio and unique surface properties. In addition, two-dimensional materials, including MoS2, SnS2, WS2, and MoSe, and ultraviolet-activated methods have been studied to develop ideal room-temperature gas sensors. Herein, a brief overview of state-of-the-art research on room-temperature gas sensors and their sensing properties, including nanostructured materials, two-dimensional materials, the ultraviolet-activated method, and ionic-activated gas sensors, is provided.

Investigation of influence of linear diffuser in the ventilation of operating rooms

  • Keshtkar, Mohammad Mehdi;Nafteh, Maryam
    • Advances in Energy Research
    • /
    • v.4 no.3
    • /
    • pp.239-253
    • /
    • 2016
  • Air quality in hospitals has always concerned hospitals' health officials due to its dangerous particles and gases. Because of the importance of air conditioning in the operating room, a system must be embedded in operating rooms to direct the contaminated air outside, and inject fresh filtered air from outside back into the room. In this study, laminar flow air conditioning system is implemented in the operating room by slot linear diffusers and with the help of air curtain. For this, stimulation Computational Fluid Dynamic (CFD) was used due to its efficiency. The aim of the present study was to find a proper solution to overcome the unfavorable factors, namely, contamination, humidity, and also temperature, velocity and pressure inside the room. These factors were implemented with different values and then stimulated through FLUENT software program. Results showed that the aforementioned factors can be overcome using air curtain and slot linear diffusers.

A Study on Acoustic Characteristics of Music Practice Room in the University (대학교내 음악연습실의 음향특성에 관한 연구)

  • Jung, Chul-Woon;Jung, Eun-Jung;Ju, Duck-Hoon;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.715-719
    • /
    • 2007
  • Recently, since there appear the quality improvement in both educational and cultural level at the college campus also, thus the lecture room is requiring by the students where the intimacy degree among the students can be raised, also a smoother interaction between the professor and the student is able to be generated. Particularly in case of College of Music, the Practical Technique Training Rooms such as Orchestral Music Room, Pipe Music Concert Room, Music-Part Practice Room are more important for the interaction between Professor and Student or Student attends at the lesson, than the lecture rooms of any other colleges. Likewise, while such music practice room should be designed with consideration of the acoustic characteristics, so as to obtain the feel as if hear it performs at a music hall, but since the most of music practice room was designed with consideration of the convenience of construction work and its economical efficiency only, it has been exposed with many acoustic defects after the completion of construction. Therefore in this thesis, it has grasped the physical acoustic characteristics on the object of the two orchestral music rooms, pipe music concert room and ensemble practice room, among the newly constructed practice rooms of the Music College, W University, and it is considered that it could be utilized as the fundamental data on the base of this material when designing of the college music practice room, for the future.

  • PDF

A Study on the Rehabilitation Room of Firefighters at Disaster Spot (재난현장 소방공무원의 회복실에 관한 연구)

  • Chae, Jin;Yim, Dong-Kyun
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.116-125
    • /
    • 2020
  • This study intends to provide a model for the establishment of a rehabilitation room for the safety and rehabilitation of firefighters by proposing a basis for the establishment of a firefighter rehabilitation room at disaster sites. To achieve the research objectives, a questionnaire, frequency analysis, and variance analysis were conducted to assess the effectiveness of rehabilitation rooms for firefighters. Based on the results of the research, the policy suggestions for operating an effective rehabilitation room are as follows. An organization of the operation of the rehabilitation room should be established at each firefighting headquarters, and human resources must be secured for the operation of the rehabilitation room. In addition, detailed operating standards such as the operation contents of the rehabilitation room's operation manager and its operator, as well as its operation procedures should be prepared. Additionally, training to improve the rehabilitation room and its understanding is needed.

A Study on Thermal and Fluid Characteristics inside Engine Room of Auxiliary Power Unit for Tracked Vehicle (궤도차량용 보조동력장치 엔진룸 내부 열유동 특성에 관한 연구)

  • Lee, Tae-Eui;Suh, Jeong-Se;Jeong, Sang-Hwan;Park, Young-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.85-93
    • /
    • 2009
  • This research is intended to grasp the characteristics of heat flow inside auxiliary power device engine room to obtain the design basic data through numerical analysis and experiment. For experiment cost reduction, numerical analysis was done to obtain quantitative data by observing the change in temperature distribution of major parts according to changes in normal condition, incompressible condition, engine surface heat emission rate and absorption temperature with the use of commercial STAR-CD. The experiment was done by grasping the temperature distribution of major interested parts inside engine room in loaded and unloaded conditions during engine operation. The temperature distribution data here will serve as useful design data during APU engine room designing.

Room-temperature Magnetotransport in Degenerately Doped GaAs:(Mn,Be) by Virtue of the Embedded Ferromagnetic Clusters

  • Yu, Fu-Cheng;Kim, Do-Jin;Kim, Hyo-Jin;Ihm, Young-Eon
    • Journal of Magnetics
    • /
    • v.10 no.3
    • /
    • pp.103-107
    • /
    • 2005
  • Magnetotransport is a prerequisite to realization of electronic operation of spintronic devices and it would be more useful if realized at room temperature. The effects of Be codoping on GaMnAs on magnetotransport were investigated. Mn flux was varied for growth of precipitated GaMnAs layers under a Be flux for degenerate doping via low-temperature molecular beam epitaxy. Magnetotransport as well as ferromagnetism at room temperature were realized in the precipitated GaAs:(Mn,Be) layers. Codoping of Be was shown to promote formation of MnGa clusters, and annealing process further stabilized the cluster phases. The room-temperature magnetic properties of the layers originate from the ferromagnetic clusters of MnGa and MnAs embedded in GaAs. The degenerately doped metallic GaAs matrix allowed the visualization of the magnetotransport through anomalous Hall effect.

Developing of an extinguishing system for a fire at an early stage in Unmanned Engine Room for small vessels (소형선박용 무인기관실 초기화재 진압시스템 개발)

  • Kim, Sung-Yoon;Kim, Dong-Seuk;Kim, You-Taek
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.333-334
    • /
    • 2006
  • Extinguishing a fire at an early stage is most important to prevent spreading of a fire in Unmanned Engine Room. The most proper fire extinguish system was analyzed after examining the Automatic spread Extinguish System, which is mostly installed in Unmanned Engine Room, reproduced in the condition of real Unmanned Engine Room.

  • PDF