Acoustic Properties of Three-room Coupled System by Connected Two Apertures (개구부로 연결된 3중 커플룸의 음향특성)

  • Na, Hae Joong;Lim, Byoung-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.340-349
    • /
    • 2016
  • A coupled room system consists of adjacent rooms and apertures where the sound energy is exchanged between the two rooms. Acoustically, a coupled room system shows a non-exponential decay profile. Most of the related researches have been to analyze the acoustic properties of two-room coupled system so far whereas three-room coupled system were seldom studied. In this regard, this paper aims to analyse the distribution of sound pressure level, sound decay curve of three-room coupled system and sound energy flow between them by using the acoustic diffusion model and to further verify them through experiments. Firstly, the sound pressure level distribution and mean sound pressure level in the steady-state condition are analyzed at various frequencies and source locations. Good agreements are observed in both experiments and analysis results. Secondly, two double slope effect quantifiers of sound attenuation, LDT/EDT and LDT/T10 are compared at various frequencies and for different source locations. The result indicates that LDT/T10, less affected by the early reflection patterns than LDT/EDT, is more suitable to the analysis and experiments of a multi-slope sound decay curve. Lastly, the sound energy flow in each room is analyzed based on the acoustic diffusion model. After the early decay stage, the sound energy is observed to flow from the room with a long reverberation time to the room with a short one.

Investigation of the Indoor Noise of Naval Vessel according to the Sound Absorption and Reverberation Time in a Cabin (함정 격실에 적용되는 흡음재와 잔향시간에 따른 실내 소음 분석)

  • Han, Hyung-Suk;Park, Mi-Yoo;Cho, Heung-Gi;Kim, Joong-Gil;Im, Dong-Been;Son, Yoon-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.586-591
    • /
    • 2010
  • The sound field can be classified to the direct and reverberant sound field. If the sound absorption material in a room is not applied sufficiently, the reverberant sound field increases and the sound pressure in a room also increases when the sound source exists in a room. Therefore, the reverberation time should be controled in order to reduce the reverberant sound as well as sound pressure level in a room. Even though the reverberation time is specified and researched widely in architectural engineering, it is rarely performed in a marine engineering. Therefore, in this research, the reverberation time in a navel vessel is researched related to the noise reduction in a cabin.

  • PDF

Development of shipboard large-sized low-noise room unit with multiple outlets (다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발)

  • Kim, Sang-Ryul;Kim, Hyun-Sil;Lee, Sung-Hyun;Park, Geun-Hyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.600-605
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlet. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

  • PDF

Development of Shipboard Large-sized Low-noise Room Unit with Multiple Outlets (다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발)

  • Kim, Sang-Ryul;Kim, Hyun-Sil;Lee, Sung-Hyun;Park, Keun-Hyo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.468-473
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlets. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

3-D Simulation of Air Flow in Cold Storage Room for Uniform Temperature Distribution (저온저장고 내부의 균일한 온도분포를 위한 3차원 공기유동 분석)

  • 성제중;고학균;조성인;양길모
    • Journal of Biosystems Engineering
    • /
    • v.25 no.4
    • /
    • pp.279-286
    • /
    • 2000
  • Most of the domestic cold storage rooms are inefficient for agricultural products because of temperature gradients inside the storage rooms. Temperature gradients are developed mainly by improper airflow pattern inside the storage room, which is a main cause of the spoilage of the agricultural products. There proper airflow pattern is essential to minimize these temperature gradients and the spoilage. The performance and characteristics of a cold storage room were determined as a function of airflow pattern and temperature distribution in forced circulation cold storage room. A commercial CFD(computational fluid dynamics) code was used to simulate 3-D airflow in the cold storage room. Solving the flow equations for the storage room, a standard k-$\varepsilon$ turbulent model was implemented to calculate steady state turbulent velocity distribution. The CFD prediction results were compared with temperature measurements inside the cold storage room. In case of pallet storage, Temperature gradients inside pallet storage was reduced because the contact area of cold air expanded through an alley of airflow in storage. But is case of bulk storage, the last temperature of storage considerably rose more than the initial temperature of storage. The reason was that bulk storage didn't include any alley of airflow in storage.

  • PDF

A Study on Improvement According to Korea and China Evacuation Laws in Office Building (오피스 빌딩의 한국과 중국 피난관련 법 검토에 따른 개선 연구)

  • Lee, Byung-Hyun;Lee, Kyung-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.51-56
    • /
    • 2017
  • In the case of office buildings, domestic and Chinese evacuation laws were compared regarding the evacuation of horizontal and vertical buildings and evacuation to refuge safety areas. A simulation was conducted based on a refuge safety area in China. In the case of evacuating 1 floor, there was no significant difference in the flow of occupants to an ancillary room area in a domestic or Chinese building, but in China, the corridor width was narrower and the occupants have saw a long. In the case of evacuating 15 floors, the flow of occupants to an ancillary room area was different. In the case of China, it was possible for occupants to enter the ancillary room more quickly because the ancillary room area was wider than those found in domestic buildings, allowing quickly passage the ancillary room door. The results of this study found that if corridor width and ancillary room area were wider, evacuation times could be reduced.

The Comparison Study of Radiative and Convective Heat Transfer in a Room Air Ventilation (환기구를 가진 실내공간에서 복사 및 대류열전달의 비교 연구)

  • 정효민;정한식;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.3
    • /
    • pp.229-235
    • /
    • 1997
  • The comparison of radiative and convective heat transfer in a room air ventilation is investi¬gated by a numerical simulation. The room air temperature distributions with radiation are appeared more uniform than without radiation at Gr= 1460 and Re=50. The mean Nusselt number in the radiative heat transfer shows less value than convective heat transfer. The total mean Nusselt number is found Wall 1> Wall 3${\fallingdotseq}$Wall 2 7 Wall 4.

  • PDF

Room Acoustic Properties of Coupled Rooms Connected by an Aperture in the Steady State Condition (정상상태조건에서의 개구부로 연결된 커플룸의 음향 특성)

  • Na, Hae Joong;Lim, Byoung-Duk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.3
    • /
    • pp.315-322
    • /
    • 2016
  • Room acoustic properties of coupled rooms connected by an aperture has been analyzed using statistical acoustic model based on the diffused sound field assumption, which has limitation in dealing with the parameters such an room geometries and non uniform absorptivity of the boundary surfaces. In order to overcome these difficulties the acoustic diffusion model has been introduced, by which distribution of the acoustic energy density can be analyzed for various shapes and wall absorptivity. In this study acoustic properties of coupled rooms connected by an aperture(e.g. door) is analyzed using acoustic diffusion equation, which is solved numerically. The mean energy densities of two rooms obtained by the diffusion model are compared with those from the statistical model. The results show good agreement for various coupling aperture sizes and absorption coefficients. For a limiting case when the partition wall is substituted by an aperture and the two rooms eventually forms a single room, results of coupled room analysis using diffusion model show good agreement with those of a single room.

Effectiveness of Ventilation Control in a Dry Room with a Heat and Moisture Source

  • Lee, Kwan-Soo;Lim, Kwang-Ok;Ahn, Kang-Ho;Jung, Young-Sick
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.4
    • /
    • pp.1-9
    • /
    • 2001
  • The temperature and moisture distributions in a dry room with a heat and moisture source -i.e., workers- are studied numerically by using a standard $k-\varepsilon$ turbulence model. In order to evaluate the effectiveness of heat and moisture ventilation inside the room, the heat removal capacity and the moisture exhaust efficiency are introduced. The effectiveness of ventilation control is analyzed by evaluating the temperature and humidity distributions in the room quantitatively. It is found that the mean absolute humidity inside the room is almost constant regardless of the models and the heat generation rates in this study range. This results from the fact that the moisture generation by the workers was relatively small. Through the modification of the design, 40% improvement in critical decay time was achieved.

  • PDF

An Experimental Study on the Floor Impact Sound Insulation of Apartment depending on the Plane Shape of Living-Room (거실평면형태에 따른 공동주택 바닥충격음 차음특성 변화에 관한 실험적 연구)

  • Park, Hyeon-Ku;Park, Chan-Wong;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.844-847
    • /
    • 2008
  • As customer's demands are varying, the type of floor plan of apartment is changed into expanded type with balcony unified to living room from general type with balcony separated from living room and so is changing the layout of L(living room), D(dining room) and K(kitchen). This study aims to examine how the type of floor plan of living room affects the floor impact sound insulation performance and to propose fundamental idea to floor plan layout of apartment in terms of floor impact sound reduction.