• Title/Summary/Keyword: energy-saving degree

Search Result 62, Processing Time 0.027 seconds

A study on the saving of energy consumption load using electrical heat control system (전기적 열제어 시스템을 사용한 에너지 소비량 감소에 관한 연구)

  • Han, Kyu Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.49 no.1
    • /
    • pp.58-66
    • /
    • 2013
  • Most of steam power plant in Korea are heating the feed water system to prevent freezing water flowing in the pipe in winter time. The heating system is operated whenever the ambient temperature around the power plant area below 5 degree Centigrade. But this kind of heat supplying system cause a lot of energy consuming. If we think about the method that the temperature of the each pipe is controled by attaching the temperature measuring sensor like RTD sensor and heat is supplied only when the outer surface temperature of the pipe is under 5 degree Centigrade, then we can save a plenty of energy. In this study, the computer program package for simulation is used to compare the energy consumption load of both systems. Energy saving rate is calculated for the location of Youngweol area using the data of weather station in winter season, especially the January' severe weather data is analyzed for comparison. Various convection heat transfer coefficients for the ambient air and the flowing water inside the pipe was used for the accurate calculation. And also the various initial flowing water temperature was used for the system. Steady state analysis is done previously to approximate the result before the simulation. The result shows that the temperature control system using RTD sensor represents the high energy saving effect which is more than 90% of energy saving rate. Even in the severe January weather condition, the energy saving rate is almost 60%.

Energy-Saving Strategy for Green Cognitive Radio Networks with an LTE-Advanced Structure

  • Jin, Shunfu;Ma, Xiaotong;Yue, Wuyi
    • Journal of Communications and Networks
    • /
    • v.18 no.4
    • /
    • pp.610-618
    • /
    • 2016
  • A green cognitive radio network (CRN), characterized by base stations (BSs) that conserve energy during sleep periods, is a promising candidate for realizing more efficient spectrum allocation. To improve the spectrum efficiency and achieve greener communication in wireless applications, we consider CRNs with an long term evolution advanced (LTE-A) structure and propose a novel energy-saving strategy. By establishing a type of preemptive priority queueing model with a single vacation, we capture the stochastic behavior of the proposed strategy. Using the method of matrix geometric solutions, we derive the performance measures in terms of the average latency of secondary user (SU) packets and the energy-saving degree of BSs. Furthermore, we provide numerical results to demonstrate the influence of the sleeping parameter on the system performance. Finally, we compare the Nash equilibrium behavior and social optimization behavior of the proposed strategy to present a pricing policy for SU packets.

Influence of Authenticity on Electrical Energy Saving Behavioral Intention (진정성이 전기에너지 절약 행동의도에 미치는 영향)

  • Kim, Young-Doo
    • The Journal of Industrial Distribution & Business
    • /
    • v.9 no.11
    • /
    • pp.67-76
    • /
    • 2018
  • Purpose - Electrical energy saving is one of the practical virtues relating to sustainable living. Therefore, policy-makers has tried to find a way to change the behaviors of individuals to encourage them to actively practice electrical energy saving, even if they have never had this concern or have only passively practiced electrical energy saving to this point. Prior research related to electrical energy saving can be categorized into several types. The first is focused on consumer characteristics linked to electrical energy saving. These studies are based on individual or household socio-demographic variables (e.g., age, gender, household income, education level, occupants, marital status, number of households), and psycho-graphics (e.g., environmental consciousness, value, attitude, motivation, lifestyle). The second is focused on policies (e.g., monetary incentives, information sharing, social comparison, feedback), and technologies (e.g., energy-efficiency home appliances, energy-reduced products, renewable resources). People generally have a favorable attitude towards electrical energy saving, while electrical energy saving practices tend to be less favorable. Therefore, it is necessary for policy-makers to seek out gaps between attitudes and behaviors and find alternatives to reduce these gaps. This study investigates the influence of authenticity on the behavioral intention of electrical energy saving. It is supposed that electrical energy saving practices are likely to be stronger as authenticity of individual or household becomes stronger. This study reviews prior literature and examines various studies to provide an understanding of the relationships between authenticity and electrical energy saving behavioral intention. Research design, data, and methodology - Hypothesis was drawn from analysis based on previous research. The items related to authenticity and electrical energy saving were selected from items found in previous research. To verify this hypothesis, data were collected via experimental survey method and the resulting data were analyzed using reliability analysis, correlation analysis, and hierarchical regression analysis. Results - This study found that authenticity had a positive impact on the behavioral intention of electrical energy saving. The higher the perceived degree of authenticity, the higher the behavioral intention of electrical energy saving. Conclusions - This study assesses the impact of authenticity on the behavioral intention of electrical energy saving. In order to enhance the practice of electrical energy saving, it is efficient strategy for policy-maker to improve the perceived authenticity of individuals.

Prediction of Heating Energy Saving Rate on the Window Type-Focus on the Apartment House (창호 구성 요소에 따른 난방에너지 절감율 예측에 관한 연구-공동주택을 중심으로)

  • Kim, Kyung-Ah;Moon, Hyeun-Jun;Yu, Ki-Hyung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.54-61
    • /
    • 2013
  • This is study on the glazing performance of the apartment house to predict energy saving rate when the early design stage by calculating heating load. there are various factors of the window type in apartment building to save energy such as window's U-value, SC or SHGC, window wall ration, frame factor, sunshade coefficient and so on. In this study, we analyzed the heating load focused on the U-value, SC and window wall ration using variable heating degree days method for a small and middle size units $59m^2$, $84m^2$, respectively. Each cases were calculated heating load of the real models compared to standard model to predict energy saving rate. From those cases it was drew the conclusion that were window's U-value, SC and window wall ration for the small and middle size units to expect 10% energy saving rate at least.

A Study on Development of Evaluation Indicators to Energy Saving PR Activities (에너지절약 홍보활동 성과 평가지표 개발)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.236-244
    • /
    • 2016
  • Theoretical review of the PR activities was initiated using Lasswell's (1948) SMCRE model to evaluate the indicators of the collaborative programs with NGO and the outcome of the activities promoting energy-saving programs. The indicators were then set based on a case study by Nho Younhwoo (2012). This paper aims to develop evaluation indicators for the activities promoting energy-saving programs and evaluate how energy consumers recognize the reputations of PR agencies (sender), PR content (message), PR media outlets (channel), and the degree to which such PR activities induce energy-saving behaviors.

Suggestion of the Worth Evaluation of Cool Air and the Allocation Methodology of Cooling Cost (냉기의 가치평가 및 냉방비 배분방법론 제안)

  • Kim, Deok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.201-208
    • /
    • 2009
  • Our government will make a plan regulating the cooling limit temperature of the summer season to 26 degree and the heating limit temperature of the winter season to 20 degree for energy saving. Where, the key point of this politic pursuit can be the charge system on heating and cooling cost. We have suggested new cost allocation methodology as a worth evaluation method in the precedent study, and preformed the worth evaluation and cost allocation on four kind of warm air produced from a heating system as an example. In this study, we applied the suggested method to four kind of cool air, and preformed the worth evaluation and cost allocation on each cool air. As a result, similarly to the precedent study, the more energy a customer saved, the more cooling unit cost decreased, and the more energy a customer consumed, the more cooling unit cost increased. From this analysis, we hope that the suggested methodology can offer a theoretical basis to the energy charge policy of government, and induce the spontaneous energy saving of consumers.

Visual Performance Evaluation Study of a Scaled Light-Shelf Model (축소모형을 이용한 광선반의 시환경 특성 평가 연구)

  • Cho, Yil-Sik;Kim, Byoung-Soo;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.

A Suggestion for the Cost Allocation Methodology of Cool Air Produced from Cooling System (냉방시스템에서 생산된 냉기의 가격배분 방법론 제안)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.499-504
    • /
    • 2008
  • Our government will make a plan regulating the cooling limit temperature of the summer season to 26 degree and the heating limit temperature of the winter season to 20 degree for energy saving. Where, the key point of this politic pursuit can be the charge system on heating and cooling cost. We have suggested new cost allocation methodology as a worth evaluation method in the precedent study, and preformed the worth evaluation and cost allocation on four kind of warm air produced from a heating system as an example. In this study, we applied the suggested method to four kind of cooling air as an example, and preformed the worth evaluation and cost allocation on each cooling air. As a result, similarly to the precedent study, the more energy a customer saved, the more heating unit cost decreased, and the more energy a customer consumed, the more heating unit cost increased. From this analysis, we hope that the suggested methodology can offer a theoretical basis to the politic pursuit of government, and induce the spontaneous energy saving of consumers.

  • PDF

A Suggestion for the Worth Evaluation of Warm Air and the Allocation Methodology of Heating Cost (온기의 가치평가 및 난방비 배분방법론 제안)

  • Kim, Deok-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.654-661
    • /
    • 2008
  • Our government will make a plan regulating the cooling limit temperature of the summer season to 26 degree and the heating limit temperature of the winter season to 20 degree for energy saving. Where, the key point of this politic pursuit can be the charge system on heating and cooling cost. Currently, the heating and cooling cost are charged as much as the volume or heat flow rate regardless of the high and low room temperature. However, we have suggested new cost estimating methodology as a worth method in the precedent study, and preformed the worth evaluation and cost allocation of electricity and heat on various cogenerations. In this study, we applied the suggested worth method to four kind of warm air, and preformed the worth evaluation and cost allocation of each warm air. As a result, the more energy a customer saved, the more heating unit cost decreased, and the more energy a customer consumed, the more heating unit cost increased. From this analysis, we hope that the suggested worth methodology can offer a theoretical basis to the politic pursuit of government, and induce the spontaneous energy saving of consumers.

A study on Energy Saving Hydraulic System Using Hydraulic Transformer (유압 트랜스포머를 이용한 에너지 절감형 유압시스템에 관한 기초연구)

  • Lee, Min-Su;Ahn, Kyoung-Kwan;Cho, Yong-Rae;Jo, Woo-Keun;Hung, Ho Triet
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.917-922
    • /
    • 2008
  • In order to reduce energy consumption, secondary controlled system has been applied to many types of equipments. In lifting equipments or press machines using hydraulic cylinder, a hydraulic transformer is used as a control component instead of a valve for motion control and a component for recovering potential energy of load. The transformer is combination of a variable displacement pump/motor as a secondary controlled element and a fixed displacement pump/motor. Based on the nominal model derived from mathematical model, the feedback type two-degree-of-freedom controller is designed and implemented. From simulation results, the disturbances including nonlinear friction torque, leakage flow and load force can be compensated and good positioning accuracy is obtained. It show that the proposed controller is effective.

  • PDF