• 제목/요약/키워드: energy storing

검색결과 179건 처리시간 0.023초

고체상 수소저장기술 동향 (Review : Hydrogen Storage in Solid State)

  • 이준웅
    • 한국군사과학기술학회지
    • /
    • 제13권6호
    • /
    • pp.1153-1171
    • /
    • 2010
  • Hydrogen is the most abundant element in the universe. Although hydrogen can produce three times more energy than gasoline and seven times than coal, the most challenging problem in utilizing hydrogen as energy carrier is its storage problem. In contrast to the liquid hydrocarbon, hydrogen can not be stored or transported easily and safely because of its extremely low boiling point(21K). Recently scientists have made a tremendous achievement in storing hydrogen capacity in solid state materials such as carbon based and metal organic frameworks materials as well as metal hydrides. In this review the author reviewed the status of the hydrogen storage technologies in solid state, the advantages and disadvantages in each category of materials and the future prospects of hydrogen storage.

Fat Cell Formation and Obesity-Related Diseases

  • Kawada, Teruo
    • Preventive Nutrition and Food Science
    • /
    • 제8권1호
    • /
    • pp.105-112
    • /
    • 2003
  • Animals possess a highly sophisticated mechanism of storing energy in adipose tissue inside their bodies. However, in humans it has been clarified that adipocyte (fat cell), which composes the body fat (adipose) tissues, development and the extent of subsequent fat accumulation are closely associated with the occurrence and advancement of various common diseases (e.g., type-2 diabetes, coronary artery disease, and hypertension) resulting from obesity. Recent exciting progress in clinical and biochemical studies of adipocytes has rapidly clarified the functions of adipocytes and adipose tissue. Interesting findings are the function of white adipocytes as "secreting cells" and the molecular mechanism undelying adipocyte differentiation at the transcriptional level in relation to nuclear receptors. Consequently, the adipose tissue is being targeted for the prevention or treatment of many common diseases. In this review, I will focus on recent information on characteristics of adipocytes and the relationship between obesity and common obesity-related diseases. diseases.

AHP를 이용한 $CO_2$ 저감 및 처리기술 분석 (An Analysis on the $CO_2$ Reduction and Sequestration Technology using the AHP)

  • 이덕기;최상진;박수억;하영진;이정태
    • 에너지공학
    • /
    • 제13권3호
    • /
    • pp.219-227
    • /
    • 2004
  • 본 연구에서는 기후변화에 따른 온실가스 감축을 위해 추진되고 있는 이산화탄소 저감 및 처리기술개발의 성과제고를 위해 개발기술들을 대상으로 기술개발 동향 및 향후 발생될 여러 가지 영향요인(impact factor)을 발굴하여 분석하였다. 이를 위해 평점법(Scoring Models Method, SMM)과 분석적계층과정(Analytic Hierarchy Process, AHP)을 이용하여 $CO_2$저감 및 처리기술에 대한 분석을 수행하였으며 평가요인별 중요도의 계량적 제시와 함께 각각의 기술들에 대한 평가요인별 우선순위를 제시하였다.

Approaches for Improving Bloom Filter-Based Set Membership Query

  • Lee, HyunYong;Lee, Byung-Tak
    • Journal of Information Processing Systems
    • /
    • 제15권3호
    • /
    • pp.550-569
    • /
    • 2019
  • We propose approaches for improving Bloom filter in terms of false positive probability and membership query speed. To reduce the false positive probability, we propose special type of additional Bloom filters that are used to handle false positives caused by the original Bloom filter. Implementing the proposed approach for a routing table lookup, we show that our approach reduces the routing table lookup time by up to 28% compared to the original Bloom filter by handling most false positives within the fast memory. We also introduce an approach for improving the membership query speed. Taking the hash table-like approach while storing only values, the proposed approach shows much faster membership query speed than the original Bloom filter (e.g., 34 times faster with 10 subsets). Even compared to a hash table, our approach reduces the routing table lookup time by up to 58%.

PoW-BC: A PoW Consensus Protocol Based on Block Compression

  • Yu, Bin;Li, Xiaofeng;Zhao, He
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권4호
    • /
    • pp.1389-1408
    • /
    • 2021
  • Proof-of-Work (PoW) is the first and still most common consensus protocol in blockchain. But it is costly and energy intensive, aiming at addressing these problems, we propose a consensus algorithm named Proof-of-Work-and-Block-Compression (PoW-BC). PoW-BC is an improvement of PoW to compress blocks and adjust consensus parameters. The algorithm is designed to encourage the reduction of block size, which improves transmission efficiency and reduces disk space for storing blocks. The transaction optimization model and block compression model are proposed to compress block data with a smaller compression ratio and less compression/ decompression duration. Block compression ratio is used to adjust mining difficulty and transaction count of PoW-BC consensus protocol according to the consensus parameters adjustment model. Through experiment and analysis, it shows that PoW-BC improves transaction throughput, and reduces block interval and energy consumption.

수막재배 단동비닐하우스의 태양열 축열이용 효과분석 (Analysis of Solar Energy Storage Using Effectiveness on Single Span Plastic Greenhouse with Water Curtain System)

  • 이성현;유영선;문종필;윤남규;이수장;김경원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.200.2-200.2
    • /
    • 2010
  • This study was carried out in order to reduce the amount of underground water which is used in the water curtain system for retaining heat. To proceed to the research, two plastic green houses of water curtain system were installed. One was equipped of internal small tunnel for keeping warm air in the interior of the house. Then the internal small tunnel for keeping warm air was fitted with PVC duct of 50cm in diameter filled with subsurface water. Storing surplus solar energy in the water filled in PVC duct was the method used to this house. Another was installed with FCU in the middle of the house, and was fitted a circulation motor in water tank for heat storage which was operated from 10 a.m. to 4 p.m. in order to interchange heat with FCU. The latter was installed with four FCUs which has a capacity of 8000kcal per hour. Consequently about 5 degrees celsius could be maintained in the interior of the internal small tunnel for keeping warm air with the external temperature of more than minus 5 degrees celsius. It appeared that the alteration of an internal temperature of the house was flexible depending on the sunlight during daytime. It happened that to prevent the water from freezing, mixing antifreezing liquid in the flowing water of FCU or changing the operating method of FCU was a suitable measure. Also, in order to use the surplus solar thermal energy on plastic green house of water curtain system efficiently, storing the surplus heat during daytime simultaneously finding a method of using water curtain systematic underground water happened to be important. As a result of this research, when the house's interior temperature is below zero the operation of FCU appeared to be impossible. Therefore when supposed that the amount of water used in the house is 150~200ton for stable operation of FCU, using the system mentioned in the above research happened to be appropriate of reducing the amount of subsurface water from 80% to 100% when maintaining the interior of internal small tunnel's temperature for keeping warm air of 5 degrees celsius at the extreme temperature of minus 5 degrees celsius.

  • PDF

A Teleoperated Cleaning Robot for a High Radioactive Environment

  • Kim, Ki-Ho;Park, Jang-Jin;Yang, Myung-Seung;Oh, Chae-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.849-854
    • /
    • 2003
  • The Korea Atomic Energy Research Institute has developed a teleoperated cleaning robot for use in the radioactive zone of the isolation room of the Irradiated Material Examination Facility where direct human access to the interior is strictly limited. The teleoperated cleaning robot that was designed to completely eliminate human interaction with the hazardous radioactive contaminants has five remotely replaceable submodules - a mobile module for navigation, a cleaning module for dislodging and sucking contaminated waste, a sensing module for obstacle avoidance, a collection module for storing the acquired waste, and a cover module for protecting the collection module. This cleaning robot is capable of cleaning the contaminated floor surface of the isolation room and collecting loose dry spent nuclear fuel debris and other radioactive waste fixed or scattered on the floor surface. The developed cleaning robot is operated either by a manual control or by autonomous control in conjunction with a graphical simulator, by which the human operator can monitor and intervene the robot performing cleanup tasks in the isolation room. In this paper, we present the mechanical and environmental design considerations and development of the teleoperated cleaning robot for radioactive isolation room use. We also demonstrate its mock-up performance test results from the viewpoint of a remote cleanup operation and remote maintenance.

  • PDF

A15083-O GMAW 용접시 불활성가스 혼합비가 용접부의 인성에 미치는 영향에 관한 연구 (The Influence of Shield Gas Ratio on the Toughness of A15083-0 GMAW Weld Zone)

  • 이동길;김건호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.113-199
    • /
    • 2002
  • In this study, the toughness was evaluated by using the instrumented Charpy impact testing procedures for A15083-O aluminum alloy used in the LNG carrying and storing tank. The specimens were GMAW welded with four different mixing shield gas ratios (Ar100%+He0%, Ar67%+He33%, Ar50%+He50%, and Ar33%+He67%), and tested at four different temperatures(+25, -30, -85, and -196$^{\circ}C$ ) in order to investigate the influence of the mixing shield gas ratio and the low temperature. The specimens were divided into base metal, weld metal, fusion line, and HAZ specimen according to the worked notch position. From experiment, the maximum load increased a little up to -85$^{\circ}C$, and the maximum load and maximum displacement were shown the highest and the lowest at -196$^{\circ}C$ than the other test temperatures. The absorption energy of weld metal notched specimens was not nearly depends on test temperature and mixing shield gas ratio because the casting structure was formed in weld metal zone. In the other hand, the others specimens was shown that the lower temperature, the higher absorption energy slightly up to -85$^{\circ}C$ but the energy was decreased so mush at -196$^{\circ}C$

  • PDF

태양열원 난방기의 수축열조 효율개선에 관한 연구 (The Study on Efficiency Improvement of a Thermal Storage Tank for Solar Combined Heating System)

  • 류남진;한유리;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.43-49
    • /
    • 2007
  • This study is conducted to improve the efficiency of a thermal storage tank. The thermal storage tank was designed to store heat energy that obtained from the solar or the others heat sources. However, it has difficulties in storing heat with nonuniform temperature through the entire tank with respect to the vertical direction, This study is focused on the thermal stratification to improve thermal comfort for the resident in house. To enhance temperature stratification of the tank, a distributor was designed and installed in the middle of the storage tank vertically. The vertically designed distributor could supply the return water with stratified temperature in the storage tank with respect to the height. The water velocity from the distributor hole is the same with the other outlet in the distributor. However, gravity effect on the flow in the storage tank is much higher than that of the velocity effect due to that Froude Number is less than 1. During the heat charging process in the storage tank, temperature maintained with little difference with respect to the height. However the charging process takes long time to get a effective temperature for the heating or hot water supply because of all of water in the storage tank needs to be heated.

Al5083-O GMA 용접시 불활성가스 혼합비가 용접부의 인성에 미치는 영향에 관한 연구 (The Influence of Shield Gas Ratio on the Toughness of Al5083-O GMA Welding Zone)

  • 이동길;조상곤;김건호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권6호
    • /
    • pp.653-660
    • /
    • 2002
  • In this study, the toughness was evaluated by using the instrumented Charpy impact testing procedures for A15083-O aluminum alloy used in the LNG carrying and storing tank. The specimens were GMAW welded with four different mixing shield gas ratios (Ar100%+He0%, Ar67%+He33%, Ar50%+He50%, and Ar33%+He67%), and tested at four different temperatures(+25, -30, -85, and $-196^{\circ}C$) in order to investigate the influence of the mixing shield gas ratio and the low temperature. The specimens were divided into base metal, weld metal, fusion line, and HAZ specimen according to the worked notch position. From experiment, the maximum load increased a little up to -$85^{\circ}C$ , and the maximum load and maximum displacement were shown the highest and the lowest at -$196^{\circ}C$ than the other test temperatures. The absorption energy of weld metal notched specimens was not nearly depends on test temperature and mixing shield gas ratio because the casting structure was formed in weld metal zone. In the other hand, the other specimens were shown that the lower temperature, the higher absorption energy slightly up to $-85^{\circ}C$ but the energy was decreased so mush at $-196^{\circ}C$.