• Title/Summary/Keyword: energy space

Search Result 3,298, Processing Time 0.032 seconds

Development of Low-Cost and Low-Power Picosatellite Electrical Power Subsystem (저비용/저전력의 초소형위성 전력계의 개발)

  • Park, Je-Hong;Kim, Young-Hyun;Moon, Byoung-Young;Chang, Young-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.105-116
    • /
    • 2004
  • The design of pico-/nano-satellites is particularly challenging due to constraints in mass, volume, power, and surface area. An efficient low-cost picosatellite HAUSAT-1 Electrical Power Subsystem (EPS) is developed to supply the power for various loads during the full mission life. This paper addresses design and analysis results of solar arrays, batteries, power conditioning and distribution units. The component selection, manufacturing and test results are presented by considering appropriate development cost and performance. The simulation results of power system are also illustrated, according to operational modes, through energy balance analysis. Finally, the EFS design feasibility is verified by comparing analysis results with functional and environmental test results at the system and component levels, respectively.

Implementation of an Optimal Many-core Processor for Beamforming Algorithm of Mobile Ultrasound Image Signals (모바일 초음파 영상신호의 빔포밍 기법을 위한 최적의 매니코어 프로세서 구현)

  • Choi, Byong-Kook;Kim, Jong-Myon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.8
    • /
    • pp.119-128
    • /
    • 2011
  • This paper introduces design space exploration of many-core processors that meet high performance and low power required by the beamforming algorithm of image signals of mobile ultrasound. For the design space exploration of the many-core processor, we mapped different number of ultrasound image data to each processing element of many-core, and then determined an optimal many-core processor architecture in terms of execution time, energy efficiency and area efficiency. Experimental results indicate that PE=4096 and 1024 provide the highest energy efficiency and area efficiency, respectively. In addition, PE=4096 achieves 46x and 10x better than TI DSP C6416, which is widely used for ultrasound image devices, in terms of energy efficiency and area efficiency, respectively.

A Study of the Reaction Characteristics on Hydrocarbon Selective Catalytic Reduction of NOx Over Various Noble Metal Catalysts (다양한 귀금속 촉매를 이용한 NOx의 탄화수소 선택적촉매환원 반응 특성에 관한 연구)

  • Kim, Sung-Su;Jang, Du-Hun;Hong, Sung-Chang
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.225-230
    • /
    • 2011
  • Characteristics of hydrocarbon selective catalytic reduction of NOx using various noble metal catalysts were investigated. The best active metal is Pt, supports are $CeO_2$ and $TiO_2$ by strong interactions between active metals, and 55% of conversion rate of NOx is shown. Pd, Rh and Ag catalysts presented a conversion of less than 20% as active metals, and supports also showed the poor activity compared to $SiO_2$ and $ZrO_2$. Experiments were performed with different types of reducing agents, amount, concentration of oxygen and space velocity in order to investigate the performance of catalysts according to operating conditions. The results confirm that the methane is better than propane as a reducing agent, and as the ratio of methane/nitrogen oxide increases, the catalytic activity increased, as the concentration of oxygen increases and space velocity decreases, the performance of catalysts increased.

Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate (도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석)

  • Yeo, In-Ae;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

Suggestion of empirical formula between FPI and specific energy through analysis of subsea tunnel excavation data (해저 터널 굴진자료 분석을 통한 FPI와 비에너지의 경험식 제시)

  • Kim, Kyoung-Yul;Bae, Du-San;Jo, Seon-Ah;Ryu, Hee-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.687-699
    • /
    • 2018
  • The construction of subsea tunnel differs from that of inland tunnel because of high water pressure due to sea water level and difficulties to reinforce the ground under construction. Therefore, it is very important to prevent trouble in advance when the subsea tunnel is constructed. In this paper, we established lots of databases about characteristics of geological and mechanical parameters on the construction of subsea tunnel using micro slurry TBM which depth is about 60 m. The correlation analysis is conducted to confirm the effect of thrust, torque and RPM among the excavation database on the net penetration rate. Also, An empirical formula is suggested to predict the net penetration rate through the correlation analysis between FPI (Field Penetration Index) and specific energy from the subsea tunnel excavation database.

Efficient Analysis of the Aerodynamic Characteristics of Rotor Blade Using a Reduced Order Model Based on Proper Orthogonal Decomposition Method (적합직교분해를 이용한 로터 블레이드의 차수축소모델 구축 및 공력특성 분석)

  • Jung, Sung-Ki;Duc, NgoCong;Yang, Young-Rok;Cho, Tae-Hwan;Myong, Rho-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.11
    • /
    • pp.1073-1079
    • /
    • 2009
  • The proper orthogonal decomposition (POD) method can identify principal modes that optimally capture the energy content from large multi-dimensional data set. In this study unsteady pressure fields on the rotor blade surface of a helicopter in forward flight are expressed by a reduced order model based on the POD method. Special modes containing high energy are analyzed to investigate the aerodynamic characteristics in more efficient way. The CFD simulation of flowfields around helicopter rotor blade in hovering motion is also conducted to validate its prediction with experimental result. In the process 7 modes containing energy ratio 99% from 240 snapshots information are identified and utilized to construct a reduced order model.

Energy Balance and Constraints for the Initial Sizing of a Solar Powered Aircraft (태양광 추진 항공기의 초기 사이징을 위한 에너지 균형 및 구속조건 연구)

  • Hwang, Ho-Yon;Nam, Tae-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.6
    • /
    • pp.523-535
    • /
    • 2012
  • Solar powered aircraft are becoming more and more interesting for future long endurance missions at hight altitudes, because they could provide surveillance, earth monitoring, telecommunications, etc. without any atmospheric pollution and hopefully in the near future with competitive costs compared with satellites. However, traditional aircraft sizing methods currently employed in the conceptual design phase are not immediately applicable to solar powered aircraft. Hence, energy balance and constraint analyses were performed to determine how various power system components effect the sizing of a solar powered long endurance aircraft. The primary power system components considered in this study were photovoltaic (PV) modules for power generation and regenerative fuel cells for energy storage. To verify current research results, these new sizing methods were applied to HALE aircraft and results were presented.

Analysis of In-situ Temperature Measurement at Gonjiam Cold Storage Cavern (곤지암 지하암반 저장고 온도계측 결과 분석)

  • Lee Gyu-Sang;Lee Chung-In
    • Tunnel and Underground Space
    • /
    • v.15 no.3 s.56
    • /
    • pp.169-176
    • /
    • 2005
  • The decreasing pattern of underground temperature measured at 'Gonjiam cold storage cavern' during 7 years which was the first commercial scale underground food storage cavern in Korea was analyzed. The variation of energy consumption was discussed by comparing the consumed energy at the initial operation stage with that at later stage, when the temperature distribution reached a stabilized condition. The point to be considered at the design stage was also discussed by comparing the required refrigerator capacity at the initial operation stage with that at later stage. The extra energy to freeze the groundwater contained in pore space was discussed by analyzing the changing pattern of the rock temperature. The variation of measured rock temperature was compared with the estimated temperature using a numerical code, FLAC. The accuracy of the numerical estimation was discussed by comparing the heat flux measured by the operation time of the refrigerator with that estimated numerically.

Current Status of Rock Cutting Technique Using Undercutting Concept (언더커팅 개념을 적용한 암반절삭기술의 현황 분석)

  • Jeong, Hoyoung;Choi, Seungbeom;Jeon, Seokwon
    • Tunnel and Underground Space
    • /
    • v.29 no.3
    • /
    • pp.148-156
    • /
    • 2019
  • In urban area, the use of mechanical excavators (e.g., TBM and roadheader) has been increasing in construction of tunnelling and underground space. The undercutting technology, which is modified from the conventional rock-cutting concept, has been developed by advanced countries. Therefore, research on the latest technology of mechanical excavation is required, and keeping carrying out research on conventional mechanical tunneling methods at the same time. In this study, as a fundamental study of the undercutting technique, the principle and concept of the undercutting were introduced, as well as the current status of the research of advanced countries. The undercutting is applicable as a full-face excavation method for the tunnels and underground spaces, as well as an auxiliary(partial-face excavation) method for extension of the existing tunnels.

Hydrogen Recombination over Pt/TiO2 Coated Ceramic Honeycomb Catalyst (Pt/TiO2 코팅 세라믹 허니컴 촉매를 이용한 수소 제어)

  • Kang, Youn Suk;Kim, Sung Su;Seo, Phil Won;Lee, Seung Hyun;Hong, Sung Chang
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.648-652
    • /
    • 2011
  • Passive autocatalytic recombiner (PAR) is considered as an explosive gas control system in operating NPP plants. This work investigates and evaluates hydrogen recombination performance over manufactured $Pt/TiO_2$ catalysts. When the space velocity increases, the hydrogen conversion decreased, while hydrogen depletion rate (g/sec) increases highly in $35000{\sim}100000hr^{-1}$ Gas Hourly Space Velocity (GHSV). Hydrogen conversion and depletion rate with Pt loading is investigated. As a result, there were no differences in the hydrogen conversion, but exothermic heating rate (K/sec) is increases as Pt loading increases. The catalyst showes a high hydrogen conversion efficiency of 80% under atmospheric conditions.