Design of Telecommunications Office Building with Passive Solar Schemes (태양열이용 전화국 기본 설계 연구)

  • Korean Solar Energy Society, Korean Solar Energy Society
    • Solar Energy
    • /
    • v.12 no.1
    • /
    • pp.40-47
    • /
    • 1992
  • The present study has been carried out to investigate various passive solar technologies for the possible application to telecommunications office buildings. HVAC systems utilizing the solar energy are analyzed in this regard to elicit the most feasible design. The proposed design is unique, for it has been devised to promote the working spirit with an efficient space planning as well.

  • PDF

Energy Saving System Based on the Human Sensing Technique (인체감지를 통한 에너지절약 시스템 개발)

  • Lee, Jong-Pil;Ji, Pyeong-Shik;Shin, Kwan-Woo;Lim, Jae-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.4
    • /
    • pp.205-209
    • /
    • 2004
  • This research is investigated an energy saving system based on human detecting technique. It saves a lot of energy by automatic switching method of lighting, appliance, and so on. Existence of people on space is detected by infrared ray sensor. If there is not anybody during definite time, then main controller of system sends "power off" signal to lighting switches, and outlets. When people are detected again, turn on lighting switches and outlets. Result of this research is adaptable for classrooms and offices, and great effect of energy saving is expected.

A Study on the Thermal Performance of a Solar House by a F-chart Method (F-chart 설계법(設計法)에 의한 태양열주택(太陽熱住宅)의 난방성능(暖房性能)에 관(關)한 연구(硏究))

  • Lee, Young-Soo;Seoh, Jeong-Ill;Yim, Jang-Soon
    • Solar Energy
    • /
    • v.2 no.2
    • /
    • pp.1-9
    • /
    • 1982
  • This paper presents a method. for estimating the useful output of solar heating sys-terns. Heating load calculations, climatic data and various conditions are used in this procedure to estimate the fraction of the monthly heating load supplied by solar energy for a particular system the design procedure presented in this paper referred to the f-chart method. The results of this study are as follows; 1) The collected energy is not rised lineary to collector area. 2) If the heating area has equivalent solar collector area, the solar energy utilization for space heating is over 90%. 3) Transmittance- absorptance product for radiation at normal incidence, (${\tau}{\alpha}$)/(${\tau}{\alpha}$)n, during most of the heating season is 0.92 for a two-cover collector. 4) Orientation of the collector has little effect on the annual performance of solar heating system within the $15^{\circ}$.

  • PDF

Analysis of Building Energy by the Typical Meteorological Data (표준기상데이터(부산지역) 비교 및 분석)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Kang, Hyun-Gu
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.13-18
    • /
    • 2009
  • Building is a major energy consumer, and now many efforts are made to save energy in the design and using equipments. The most noticeable achievement in those efforts is a building energy performance assessment program. But most programs are not satisfying enough to provide exact meteorological data, and data source and calculation, and data collection period are not clearly defined. That is common in most of domestic programs. This study collects typical meteorological data in 16 items and analyzes them with Visual DOE 4.0 to compare with existing data. The comparison found that revised data shows a 11% increase on average during cooling period from June to September, and a 13% decrease on average during heating period from December to February, in terms of building heating and cooling load in a monthly basis.

  • PDF

NON CONVENTIONAL METHOD FOR SOFT STARTING OF THREE PHASE INDUCTION MOTORS

  • Ahmed Nabil A.;Kim Sung-Jun;Suh Ki-Young;Kown Soon-Kurl;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.27-31
    • /
    • 2004
  • This paper presents a nonconventional method for oft starting of three-phase induction motors, which achieved by flux weakening technique. flux weakening is not done by reducing the applied voltage as in the conventional methods, Flus weakening is achieved y increasing the supply frequency over the rated value while the voltage amplitude is kept constant. This method has advantage of reducing the stress on the electrical and mechanical systems. The feasibility of this basic idea has been confirmed through investigating the starting transient corresponding to this mode of operation. For this purpose, a rigorous state space mathematical model has been developed and simulated. The validity of the proposed method through the results from the mathematical model have been confirmed experimentally.

  • PDF

Analysis and Improvement of Cooling System for Energy Saving in Data Center Building (데이터센터의 냉방에너지 절감을 위한 냉각시스템 분석 및 개선 방안)

  • Jung, Yong-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.314-319
    • /
    • 2011
  • Energy Cost has been rapidly increased with the internal heat gain of data center to keep the temperature condition. But the cooling units for server systems are fully operated to satisfy the indoor temperature condition, it results in the excessive energy consumption. In this study, various cooling systems were studied for data center and cold aisle containment system was proved to be the best solution for server cooling system. Because it protects the cooling zone from the hot aisle space. Effective cooling and prohibition of recirculation air from hot aisle was possible by the cold aisle containment system.

  • PDF

Iginition energy effects and noxious product gases of combustible premixed gas in closed space (밀폐공간내의 가연성가스의 점화외 유독성 가스 발생에 대한 연구)

  • 김한석;오규형;최연석;문정기
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.3
    • /
    • pp.35-42
    • /
    • 1992
  • Ignition energy effects of concentration of mixed gas In closed cylindrical vessel(1, 832㎤) are studied. The ignition energy ranged from 25 Joule to 110 Joule, and hidrogen and methane gases were used for flammable gas at stoichiometric condition with oxygen gas and nitrogen gas (N2) was for inert gas, which concentration was maximum 60% . The explosion pressure, temperature, concentration of product gases were calculated. It is found that - The explosion pressure and explosion velocity increase with ignition energy. - The gradience of explosion velocity with ignition energy is steeper than explosion pressure. - The results of calculation are similiar with results of experiment. - NOx is not serious product gas for methane and hydrogen gas, but CO is serious at certain concentration for methane in asphyxiation.

  • PDF

The characteristics of bending collapse of aluminum/GFRP hybrid tube (알루미늄/GFRP 혼성튜브의 굽힘붕괴 특성)

  • 송민철;이정주
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.84-87
    • /
    • 2000
  • Square tubes used for vehicle structure components have an important role on keeping its stiffness and preserving occupant safety in vehicle collision and rollover in which it experience axial collapse, bending collapse or both. Bending collapse, which absorbs kinetic energy of the impact and retains a survival space for the occupant, is a dominant failure mode in oblique collision and rollover. Thus, in this paper, the bending collapse characteristics such as the maximum bending moment and energy absorption capacity of the square tube replaced by light-weight material were evaluated and presented. The bending test of cantilever tubes which were fabricated with aluminum, GFRP and aluminum/ GFRP hybrid by co-curing process was performed. Then the maximum bending moment and the energy absorption capacity from the moment-angle curve were evaluated. Based on the test results, it was found that aluminum/ GFRP hybrid tube can show better specific energy absorption capacity compared to the pure aluminum or GFRP tube and can convert unstable collapse mode which may occur in pure GFRP tube to stable collapse mode like a aluminum tube in which plastic hinge is developed.

  • PDF

Transient Analysis of Self-Powered Energy-Harvesting using Bond-Graph

  • Makihara, Kanjuro;Shigeta, Daisuke;Fujita, Yoshiyuki;Yamamoto, Yuta
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.1
    • /
    • pp.47-52
    • /
    • 2015
  • The transient phenomenon of self-powered energy-harvesting is assessed using a bond-graph method. The bond-graph is an energy-based approach to describing physical-dynamic systems. It shows power flow graphically, which helps us understand the behavior of complicated systems in simple terms. Because energy-harvesting involves conversion of power in mechanical form to the electrical one, the bond-graph is a good tool to analyze this power flow. Although the bond-graph method can be used to calculate the dynamics of combining mechanical and electrical systems simultaneously, it has not been used for harvesting analysis. We demonstrate the usability and versatility of bond-graph for not only steady analysis but also transient analysis of harvesting.

Development of a Microwave Discharge Ion Engine using Multi-Monopole Antenna

  • Nakashima, H.;Miyamoto, T.;Mii, K.;Nishijima, T.;Ijiri, H.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.314-317
    • /
    • 2004
  • On 9/5/2003, the planet probe “HAYABUSA” as MUSES-C project was launched by The Institute of Space and Astronautical Science. “HAYABUSA” has microwave discharge ion engines and these engines are characterized by their high efficiency and specific impulse in comparison with chemical engine. A large ion engine can be used as a planet explorer, while a small ion engine can be used as attitude control of small satellite. We have been developing a high thrust density microwave discharge ion engine using “Multi-Monopole Antenna”. The performance of this engine are: ion cost of 344W/A, propellant utilization efficiency of 52% and thrust density of 0.055mN/$\textrm{cm}^2$ for Kr gas flow rate of 2.5sccm, microwave(2.45㎓) power of 32W and acceleration voltage of l.4㎸.

  • PDF