• Title/Summary/Keyword: energy space

Search Result 3,298, Processing Time 0.03 seconds

Analysis on the Strategic Bidding of the Generation Capacity in an Electricity Market by Using Game Theory (전력시장에서 발전가능용량의 전략적 입찰에 대한 게임이론적 해석)

  • 이광호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.5
    • /
    • pp.302-307
    • /
    • 2004
  • As deregulation of power industry is becoming a reality, there has been an intense interest in the strategic bidding for suppliers to maximize their profits. The profit gained by a supplier is related not only to its energy-price bid curve but also to its submitted operational parameters such as generation capacity, etc. So suppliers are willing to use those strategic parameters that can be manipulated by themselves and are effective to their profit. This paper deals with the competition model with compound strategies: generation capacity and bidding curve. The parameter space is modeled by dividing into the two strategies, so the problem is made up of the four types of sub-game in a two player game. This paper analyzes the global Nash Equilibrium (NE) over the whole divisions by computing the sub-game NEs in some divisions and by deriving the best response curves which have discontinuities in other divisions. The global NE is shown to correspond to the Cournot NE where the quantity variable is realized by a constraints of a generation capacity.

Energy Band Schemes in Organic Electroluminescent Devices Using Terbium Complexes Prepared by Vacuum Evaporation Method (진공 증착법에 의한 Terbium Comp1exes를 이용한 유기 전기 발광 소자의 에너지 밴드에 관한 연구)

  • 표상우;김옥병;이한성;최돈수;이승희
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.582-588
    • /
    • 1999
  • 정보화 사회의 발전과 함께 멀티미디어에 대한 관심이 집중되고 있으며, 점유 공간이 작고 가벼우며 대면적이 가능한 정보 표시 디스플레이에 대한 기술은 고부가가치 산업으로 인식되어 지고 있다. 이러한 정보 표시 디스플레이들 중, 전기 발광 소자 (Electroluminescence Display : ELD), 액정 표시 디스플레이 (Liquid Crystal Display LCD), 플라즈마 디스플레이 (Plasma Display Panel) 등의 대한 연구가 세계적으로 매우 활발하게 진행되고 있다. 본 연구에서는 란탄 계열의 금속 착 화합물인 Tb(ACAC)$_3$(Phen)과 Tb(ACAC)$_3$(Phen-Cl)를 이용해 다비이스를 제작한후 광학적 및 전기적 특성을 조사하였다. 또한 luminous efficiency와 cyclic voltametric 방법을 이용해 에너지 밴드로 두 발광 물질인 Tb(ACAC)$_3$(Phen)과 Tb(ACAC)$_3$(Phen-Cl)을 비교.분석하였다. 본 연구의 디바이스 구조를 보면 anode/hole transporting layer (HTL)/emitting material layer (EML)/electron transporting layer (ETL)/cathode와 같고 ETL를 aluminum-tris- (8-hydroxyquinoline) (Alq$_3$)와 bis(10-hydroxybenzo(h)quinolinato)beryllium (Bebq$_2$)를 사용하였으며 HTL 로 N,N'-diphenyl-N,N'-bis(3-methylphenyl)-1,1'-biphenyl-4,4'-diamine (TPD)를 사용하였다.

  • PDF

EL Devices for LCD Backlight Based on ZnS:Cu Phosphor (혼합파우더 및 절연박막층을 이용한 PELD의 광학특성)

  • 박수길;조성렬;전세호;엄재석;이주성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.391-394
    • /
    • 1998
  • Electroluminescence is the light emission obtained by an electrical excitation energy passing through a phosphor under an applied high electrical field. EL are paid much attention on flat panel display as a backlight and indicator, which are divided into ACPRL(alternating-current powder electroluminescent) and ACTFEL(alternating-current powder electroluminescent). In this paper, Electric and emission properties on ACPEL are investigated based on ZnS:Cu phosphor. The basic structure on this is ITO glass/phosphor/insulator/ backelectrode, CR-M which has high efficiency on thermal properties and dielectric Properties was introduced and BaTiO$_3$ as a insulating layer in order to increase app1ied electric field on phosphor. Changing on Dielectric and emission Properties was caused by a different viscosity of binder which filled on space between phosphor particle. 60cd/$m^2$ under 60V, 2kHz sinusoidal was gotten from ACPELD prepared in this work.

  • PDF

Dynamic analysis of frames with viscoelastic dampers: a comparison of damper models

  • Lewandowski, R.;Bartkowiak, A.;Maciejewski, H.
    • Structural Engineering and Mechanics
    • /
    • v.41 no.1
    • /
    • pp.113-137
    • /
    • 2012
  • Frame structures with viscoelastic (VE) dampers mounted on them are considered in this paper. It is the aim of this paper to compare the dynamic characteristics of frame structures with VE dampers when the dampers are modelled by means of different models. The classical rheological models, the model with the fractional order derivative, and the complex modulus model are used. A relatively large structure with VE dampers is considered in order to make the results of comparison more representative. The formulae for dissipation energy are derived. The finite element method is used to derive the equations of motion of the structure with dampers and such equations are written in terms of both physical and state-space variables. The solution to motion equations in the frequency domain is given and the dynamic properties of the structure with VE dampers are determined as a solution to the appropriately defined eigenvalue problem. Several conclusions concerning the applicability of a family of models of VE dampers are formulated on the basis of results of an extensive numerical analysis.

Incompressible smoothed particle hydrodynamics modeling of thermal convection

  • Moballa, Burniadi;Chern, Ming-Jyh;Odhiambo, Ernest
    • Interaction and multiscale mechanics
    • /
    • v.6 no.2
    • /
    • pp.211-235
    • /
    • 2013
  • An incompressible smoothed particle hydrodynamics (ISPH) method based on the incremental pressure projection method is developed in this study. The Rayleigh-B$\acute{e}$nard convection in a square enclosure is used as a validation case and the results obtained by the proposed ISPH model are compared to the benchmark solutions. The comparison shows that the established ISPH method has a good performance in terms of accuracy. Subsequently, the proposed ISPH method is employed to simulate natural convection from a heated cylinder in a square enclosure. It shows that the predictions obtained by the ISPH method are in good agreements with the results obtained by previous studies using alternative numerical methods. A rotating and heated cylinder is also considered to study the effect of the rotation on the heat transfer process in the enclosure space. The numerical results show that for a square enclosure at, the addition of kinetic energy in the form of rotation does not enhance the heat transfer process. The method is also applied to simulate forced convection from a circular cylinder in an unbounded uniform flow. In terms of results, it turns out that the proposed ISPH model is capable to simulate heat transfer problems with the complex and moving boundaries.

A Study on the Characteristic of Remote Control Valve Using Simulation X (SimulationX를 이용한 Remote Control Valve의 특성 분석에 관한 연구)

  • Jeong, Yoo Seong;Chung, Won Jee;Lee, San Sung;Lee, Jung Min;Choi, Kyoung Shin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.78-84
    • /
    • 2017
  • Compared to other types of power, hydraulic energy is the most commonly used for heavy vehicles and ships because it has fewer location and space constraints, and its controllability can be maintained even under adverse conditions. Operators have controlled a main control valve of ship winches by pushing or pulling the lever, which is directly connected to the spool. However, because of the spatial arrangement, the importance of remote control valves has emerged. In this paper, experiments of the hysteresis characteristics were performed by analyzing the remote-control valve using a valve tester and RA2300. The validity was verified by comparing with the analytical model using SimulationX as the hydraulic analysis program. This study examined the effects of the spool's notch (Non, End-mill, and Spherical) and the effects of stiffness and pre-load of the spool spring on Spool stroke, open area, and hysteresis characteristics. It is considered possible to reduce the cost and the, trial and error process in designing remote-control valves in the future.

Numerical Study on Operating Parameters and Shapes of a Steam Reformer for Hydrogen Production from Methane (천연가스로부터 수소를 생산하기 위한 수증기 개질기의 작동조건과 형상에 대한 수치해석 연구)

  • Park, Joong-Uen;Lee, Shin-Ku;Lim, Sung-Kwang;Bae, Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.1
    • /
    • pp.60-68
    • /
    • 2009
  • The steam reformer for hydrogen production from methane is studied by a numerical method. Langmuir- Hinshelwood model is incorporated for catalytic surface reactions, and the pseudo-homogeneous model is used to take into account local equilibrium phenomena between a catalyst and bulk gas. Dominant chemical reactions are Steam Reforming (SR) reaction, Water-Gas Shift (WGS) reaction, and Direct Steam Reforming (DSR) reaction. The numerical results are validated with experimental results at the same operating conditions. Using the validated code, parametric study has been numerically performed in view of the steam reformer performance. As increasing a wall temperature, the fuel conversion increases due to the high heat transfer rate. When Steam to Carbon Ratio (SCR) increases, the concentration of carbon monoxide decreases since WGS reaction becomes more active. When increasing Gas Hourly Space Velocity (GHSV), the fuel conversion decreases due to the heat transfer limitation and the low residence time. The reactor shape effects are also investigated. The length and radius of cylindrical reactors are changed at the same catalyst volume. The longer steam reformer is, the better steam reformer performs. However, system energy efficiency decreases due to the large pressure drop.

Evaluation of Thermal Performance for Air-Barrier Air-conditioning System in Perimeter Zone by Scale Model Experiment and Simulation (모델실험 및 수치해석을 통한 페리미터존 에어배리어 공조방식웨 열성능 평가)

  • Ham Heung-Don;Park Byung-Yoon;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.10
    • /
    • pp.947-955
    • /
    • 2005
  • For the purpose of evaluating the thermal performance for air-barrier air conditioning system in perimeter zone, two air-conditioning systems, conventional perimeter air-conditioning system and air-barrier system, are evaluated and compared by scale model experiment and simulation during cooling season. As a result, measurement shows that supply air velocity of 1 m/s in the upstream direction at perimeter is more effective. Air-barrier system could reduce the cooling energy by $10\sim20\%$ compared with conventional system. Numerical simulation was carried out considering solar effect for reliable result. This method has improved the accuracy of numerical simulation for the space affected by the solar radiation. Both measurement and simulation results show that supply air velocity of 1 m/s at perimeter is the most effective.

Self-Powered Solar Tracker System without CPU (CPU 없는 자가 동력 태양광 트랙커 시스템)

  • Lee, Jae Jin;Choi, Woo Jin;Kim, Seok-Min;Park, Joon Young;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.211-218
    • /
    • 2017
  • This paper proposes the self-powered solar tracker system without CPU. Conventional solar tracker system occurs the problem of cost and durability because of using CPU. In addition, this system has effects from installation site and environment. The proposed solar tracker system without CPU is possible to achieve the high efficiency because it tracks the maximum of the light source. The validity of proposed solar tracking system is verified with experiment results.

Experimental and ab initio Computational Studies on Dimethyl-(4-{4-{3-methyl-3-phenyl-cyclobutyl)-thiazol-2-yl]-hydrazonomethyl}-phenyl)-amine

  • Yuksektepe, Cigdem;Saracoglu, Hanife;Caliskan, Nezihe;Yilmaz, Ibrahim;Cukurovali, Alaaddin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3553-3560
    • /
    • 2010
  • A new hydrazone derivative compound has been synthesized and characterized by IR, $^1H$-NMR, $^{13}C$-NMR and UV-vis. spectroscopy techniques, elemental analysis and single-crystal X-ray diffraction (XRD). The new compound crystallizes in monoclinic space group C2/c. In addition to the crystal structure from X-ray experiment, the molecular geometry, vibrational frequencies and frontier molecular orbitals analysis of the title compound in the ground state have been calculated by using the HF/6-31G(d, p), B3LYP/6-311G(d, p) and B3LYP/6-31G(d, p) methods. The computed vibrational frequencies are used to determine the types of molecular motions associated with each of the observed experimental bands. To determine conformational flexibility, molecular energy profile of (1) was obtained by semi-empirical (AM1) calculation with respect to a selected degree of torsional freedom, which was varied from $-180^{\circ}$ to $+180^{\circ}$ in steps of $10^{\circ}$. Molecular electrostatic potential of the compound was also performed by the theoretical method.