• Title/Summary/Keyword: energy space

Search Result 3,298, Processing Time 0.033 seconds

Economic Evaluation of Various Cooling Systems (냉방기기별 경제성 평가)

  • Kim, Young-Il;Cho, Keum-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.214-219
    • /
    • 2008
  • In this study, medium capacity EHP and GHP for air-conditioning a building with a floor area of $1,200\;m^2$ are compared economically. To consider all the factors of initial and operation costs effectively, an annual equal payment method is proposed. For the initial cost, equipment, construction, installation, electric facility, financial subsidy and tax cut are considered. Basic electricity, energy(electricity and gas), space charge, labor, insurance and repair are considered for the operation cost. Under the assumptions made in this study, overall cost of EHP is less than that of GHP. However, different outcome may result if different assumptions are made. This study is useful for performing an economic evaluation of various air-conditioning systems.

  • PDF

Nonlinear Behavior of RC Columns Subjected to Cyclic Loadings (반복하중을 받는 철근콘크리트 기둥의 비선형 거동)

  • 곽효경;김선필
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.475-482
    • /
    • 2002
  • A moment-curvature relationship to simulate the behavior of reinforced concrete (RC) columns under cyclic loading is introduced. Unlike previous moment4curvature models and the layered section approach, the proposed model takes into account the bond-slip effect by using a monotonic moment-curvature relationship constructed on the basis of the bond-slip relation and corresponding equilibrium equation at each nodal point. In addition, the use of curved unloading and reloading branches inferred from the stress-strain relation of steel gives more exact numerical result. The pinching effect caused by axial force is considered with an assumption that the absorbing energy corresponding to any deformation level maintains constant regardless of the magnitude of applied axial lone. The advantages of the proposed model, comparing to layered section approach, may be on the reduction in calculation time and memory space in case of its application to large structures. Finally, correlation studies between analytical result and experimental studies are conducted to establish the validity of the proposed model.

  • PDF

A Perspective of Basic Concept in Design Process for The 3rd Generation KTX(HEMU-400X) (제3세대 고속열차(HEMU-400X) 디자인 프로세스의 기본개념에 대한 고찰)

  • Kim, Sung-Yong;Yi, Jong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1779-1792
    • /
    • 2009
  • Now, the goal of the third generation KTX project is to create a new species of high speed train in order to open a new era of high speed railway system in history by authentic Korean technology and innovative design. Now the third generation KTX, must go beyond the original stagnant paradigm and be positioned as an emotional resource which is creating a shift in the public's perspective of transportation and expanding the idea that transportation intersects the two distinct realms of culture and environment as well. In addition, the overall design should reflect the Korean culture and characteristics, simple yet resonant, both the interior space and the exterior fuselage should portray the dynamic heritage of Korea such as the powerful yet subdued energy of Jung Joong Dong. In short, through the symbolic key words in Korean, Dong(Dynamics), Mek(Pulse), Ryu(Flow), Gam(Sensibility), the third generation KTX design project aims to create an new identity of Korean high speed railway which can stand globally.

  • PDF

Three Points of the Residential High-Rise: Designing for Social Connectivity

  • Gang, Jeanne
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.2
    • /
    • pp.117-125
    • /
    • 2016
  • In this paper we discuss the terms "exo-spatial design," "solar carving," and "bridging" as strategies for creating more socially connective tall buildings. As a typology, high-rise residential buildings have a unique set of challenges to becoming fully activated urban participants in the cities in which they are located. While there is a general recognition and appreciation that tall buildings provide identity to a city, there is often criticism of how they relate to their surroundings. Critics have posited that tall buildings are insular and foreboding by their very nature. This paper explores several design avenues for architects to consider in order to improve the social aspect of tall buildings. As all cities become taller and denser to accommodate growth, the need to design social space in, on, and around tall buildings must be continually examined if we are to have cohesive urban fabric that supports communities.

Optimal Velocity Profile for Minimum Power Consumption of Korean Total Artificial Heat

  • Chang, Jun-Keun;Min, Byoung-Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.51-64
    • /
    • 1997
  • A dynamic model of the Korean total artificial heart(TAH) which contains a brushless DC motor, all of mechanical components, the pump system with integrated variable volume space(WS) and the circulatory system model including the bronchial circulation were established Two different sets of seven differential equations were separately derived for the left and right systolic period of the Korean TAH operation. Throughout the computer simulation, a full-state fEedback optimal controller that minimizes the power consumption of the Korean TAH and drives the end stage velocity of the energy converter to zero was developed based upon the optimal control theory. Robustness of the controller were also analyzed with the dynamic model of the Korean TAH.

  • PDF

Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System (3실형 인버터 열펌프 시스템의 냉방성능 측정)

  • 정광진;최영돈;장효환;송재복;박윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

Study on the Turbulent Boundary Layer Disturbed by a Triangular Prism near the Wall (벽근방의 3각주에 의하여 교란받는 난류경계층에 관한 연구)

  • Sim, W.G.;Lee, K.J.;Cho, Y.C.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.161-167
    • /
    • 1991
  • This paper presents the results of some measurement of the fluctuating velocity field in the turbulent boundary layer disturbed by a triangular prism and discusses the discovery of the disturbed boundary layer. A prism of height 8mm was used for experiments. The streamwise location of the prism was fixed at 1200mm downstream from the leading edge and the space between the prism center and the wall was set at three different values, 6, 15 and 33.5mm. The results show that the near-wall region of the disturbed boundary layer recovers original state much more quickly than the outer region. In the case h=6mm the recovery is faster than the other cases. Moreover, it was found that peak of fluctuating velocities moves outwards somewhat rapidly with increasing ${\times}$ mainly due to the turbulent diffusion of the fluctuating velocity.

  • PDF

Numerical analysis for the optimum design of a triple-glazed airflow window (환기식 3중 집열창의 최적설계를 위한 수치해석 연구)

  • Kim, H.J.;Hwang, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.484-496
    • /
    • 1997
  • The fluid flow and heat transfer characteristics of conjugate forced and natural convection in the triple-glazed airflow window, where the outer air passes through a space contrived between the interior and exterior window panes, were studied numerically by a finite volume method for the elliptic form of the Navier-Stokes equations. The investigation focused on the influence of window geometry, ventilastion rate and solar energy on the temperature, velocity distribution and thermal performance of the airflow window. The comparison between the triple-glazed airflow window and the enclosed triple-glazed window was also made to evaluate the effect of buoyancy upon which the thermal performance of the window depended.

  • PDF

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

H(sub)$\infty$ Design for Decoupling Controllers Based on the Two-Degree-of-Freedom Standard Model Using LMI Methods (LMI 기법을 이용한 2자유도 표준모델에 대한 비결합 제어기의 H(sub)$\infty$ 설계)

  • Gang, Gi-Won;Lee, Jong-Sung;Park, Kiheon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.3
    • /
    • pp.183-192
    • /
    • 2001
  • In this paper, the decoupling H(sub)$\infty$ controller which minimizes the maximum energy in the output signal is designed to reduce the coupling properties between the input/output variables which make it difficult to control a system efficiently. The state-space formulas corresponding to the existing transfer matrix formulas of the controller are derived for computational efficiency. And for a given decoupling $H_{\infty}$ problem, an efficient method are sought to find the controller coefficients through the LMI(Linear Matrix Inequalities) method by which the problem is formulated into a convex optimization problem.

  • PDF