• Title/Summary/Keyword: energy space

Search Result 3,298, Processing Time 0.032 seconds

Analysis of the Current-Fed DC-DC Converter with Energy-Storage Reactor Feeding the Input (전원에 에너지가 회생되는 전류형 DC-DC 콘버어터의 해석)

  • ;原田耕介
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.4
    • /
    • pp.41-46
    • /
    • 1983
  • The current-fed DC-DC converter has only one energy storage reactor in series with the input for any number of outputs and is insensitive to transformer volt-second unbalance. It is considered that these properties of the converter are considerable advantages over other maltiple-output circuits. The steady-state and dynamic characteristic and stability for the current-fed DC-DC con-verter are analyzed in detail. The analysis is carried out by the state-space averaging method for the operation with the duty ratio less than 50% and is confirmed by the experiment. From the evaluation of stability it is identified that the stability of this converter is excellent as compared with that of the conventional buck type converter.

  • PDF

A STUDY OF THE DYNAMICAL CROSS CORRELATION FUNCTION IN A BLACK HOLE SOURCE XTE J1550-564

  • SRIRAM, K.;CHOI, C.S.;RAO, A.R.
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.599-601
    • /
    • 2015
  • The short time scale X-ray variability associated with the accretion disk around compact objects is complex and is vaguely understood. The study of the cross correlation function gives an insight into the energy dependent behavior of the variations and hence connected processes. Using high resolution RXTE data, we investigate the dynamical cross correlation function of an observation of a black hole source XTE J1550-564 in the steep power law state. The cross correlation between soft and hard X- ray energy bands revealed both correlated and anti-correlated delays (${\leq}{\pm}15s$) on a correlation time scale of 50 s. It was noticed that the observed delays were similar to the delays between X-ray and optical/IR bands in other black hole and neutron star sources. We discuss the possible mechanisms/processes to explain the observed delays in the dynamical CCF.

Numerical Study of Natural Convection in a Rectangular Enclosure with Cooling Strip (냉각부(冷却部)를 갖는 사각형(四角形) 밀폐공간내(密閉空間內)의 자연대류(自然對流)에 관(關)한 수치해석(數値解析))

  • Lee, Cheong-Ouk;Seo, Jeong-Yun;Kim, Chong-Bo
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.54-61
    • /
    • 1986
  • The influence on natural convection was studied by solving the partial differential equations within a rectangular enclosure which have a cooling strip at the right side wall of the space, a isothermally heated bottom plate and adiabatic two other walls. Computation was carried out for the range of Grashof number from $5*10^3$ to $2.5*10^5$ with Plandtl number of 0.73. The results have been obtained in cases of four aspect ratios and various strip sizes. Temperature and Stream function distributions have been plotted using explicit finite difference method in two dimensional, laminar flow, and also mean Nusselt number and Local Nusselt number have been obtained.

  • PDF

Analysis of the Air-flow for Natural Ventilation of Express Bus (고속버스 자연환기구의 기류패턴 분석)

  • Yoo, Ho-Chun;Noh, Kyoung-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.336-341
    • /
    • 2009
  • In express bus which has no window, the air quality inside the bus is very critical for the passengers who staying for an extended time. Air conditioning system using natural energy is expected to significantly improve the air quality while the bus runs the suburban area. But the express buses today usually attempt to ventilate using air conditioning system, rather than natural ventilation. In this study, analysis of existing ventilation opening and the new ventilation system on roof, using computer simulation. As a result, two cases using existing ventilation device was found to be effective for partial ventilation only, while the air in front remains standstill. The new system proved to have promoted more dynamic ventilation in most of space.

  • PDF

A study on Control System of the Heat Treating Furnace (열처리로 제어시스템 개발)

  • Kim, Sang-Yong;Park, Soo-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.3
    • /
    • pp.405-410
    • /
    • 2011
  • The heat treatment of the steel is very important part on the forging industry. It is also effect to price competitiveness. The burner control system of the heat treating furnace is related LNG gas saving and fixed manufactured goods rate. This study show the burner control performance of the heat treating furnace. The result developed the performance of the heat treating furnace and show energy saving.

The Effects of Temperature Change on the Bending Strength of CF/PEEK Laminates after Impact (온도변화가 CF/PEEK 적층재의 충격 후 굽힘강도에 미치는 영향)

  • 양인영;정종안;나승우
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.2
    • /
    • pp.34-39
    • /
    • 2003
  • In this paper, when CF/PEEK laminates for high efficiency space structure are subjected to FOD(Foreign Object Damage), the effects of temperature change on the impact damages(interlaminar separation and transverse crack) of CF/PEEK laminates and the relationship between residual lift and impact damages are experimentally investigated. Composite laminates used in this experiment are CF/PEEK orthotropic laminated plates, which have two-interlaces [$0^{\circ}_4/90^{\circ}_8/0^{\circ}_4$]. A steel ball launched by the air gun collides against CF/PEEK laminates to generate impact damages. And then CF/PEEK specimens with impact damages are observed by a scanning acoustic microscope under room and high temperatures. In this experimental results, various relations are experimentally observed including the delamination area vs. temperature change, the bending strength vs. impact energy and the residual bending strength vs. impact damage of CF/PEEK laminates.

Loss Analysis and Comparison of Grid-connected Bidirectional Inverter with Different Types of PWM Schemes (PWM 방식에 따른 계통연계 양방향 인버터의 손실양상 비교 및 분석)

  • Heo, Sung-Jun;Ahn, Hyo-Min;Byun, Jong-Eun;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.547-550
    • /
    • 2017
  • This paper presents a loss analysis and compares three pulse width modulation (PWM) methods applied in a three-phase grid-connected bidirectional inverter for an energy storage system. The losses in switching devices and output low pass filters are theoretically analyzed by using PWM control techniques. Grid-connected bidirectional inverters are designed by using PWM techniques, and the designed inverters are simulated to verify the analysis results.

직류 전계하 LLDPE/EVA혼합필름의 절연파괴특성

  • 고시현;김형주;이종필;신현택;이충호;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.65-68
    • /
    • 2000
  • Polyethylene, has long history and is widely used, was researched due to good electrical properties by many authors. But PE under stress has the critical defects of space charge accumulation and tree growth, so various methods such as catalyst, additives and blend to improve these problems have been execute, of which we selected blending method. As in our previous papers we investigated electrical conduction, dielectric and AC dielectric breakdown characteristics, we did DC dielectric breakdown characteristics in this paper. We selected pure LLDPE, pure EVA and LLDPE films mixed with EVA as specimens, which were mixed with the weight percentages of 50, 60, 70 and 80[wt%] to be thin film. DC applying voltage speed was 500[V/sec]. The relation between dielectric breakdown characteristics and the variations of super structure due to mixing was investigated, and especially trap level at amorphous region, threshold energy increment of conductive electron at free volume were considered.

  • PDF

An important factor for the water gas shift reaction activity of Cu-loaded cubic Ce0.8Zr0.2O2 catalysts

  • Jang, Won-Jun;Roh, Hyun-Seog;Jeong, Dae-Woon
    • Environmental Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.339-344
    • /
    • 2018
  • The Cu loading of a cubic $Ce_{0.8}Zr_{0.2}O_2$-supported Cu catalyst was optimized for a single-stage water gas shift (WGS) reaction. The catalyst was prepared by a co-precipitation method, and the WGS reaction was performed at a gas hourly space velocity of $150,494h^{-1}$. The results revealed that an 80 wt% $Cu-Ce_{0.8}Zr_{0.2}O_2$ catalyst exhibits excellent catalytic performance and 100% $CO_2$ selectivity ($X_{CO}=27%$ at $240^{\circ}C$ for 100 h). The high activity of 80 wt% $Cu-Ce_{0.8}Zr_{0.2}O_2$ catalyst is attributed to the presence of abundant surface Cu atoms and the low activation energy of the resultant process.

An Analysis of Economy Improvement Method and Power Demand Effect when the Battery is Applied to the Building Based on the Measured Energy Consumption (전기저장장치의 건물수용가 적용에 따른 Demand영향 및 경제성 향상방안)

  • Yang, Seung-Kwon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.86-93
    • /
    • 2015
  • Recently, ESS became efficient device to stabilize electric power supply system with the development SG related technology. In fact. there are some constraints to supply ESS, because of the high cost and required space, but rapid technology development for ESS will make it more useful soon. So, through this paper, we analyzed the benefit and demand effect when the battery is applied the building based on the measured energy consumption. After that, we got the conclusion that there is a volume limit in ESS application, in a benefit view point. And we realized that there is a demand violation, and the Cost-based BEMS is the best solution to enhance the effect of ESS application.