• Title/Summary/Keyword: energy saving efficiency

Search Result 800, Processing Time 0.026 seconds

A BIM-based Design Method for Energy-Efficient Housing (BIM 기반의 저에너지 주거공간 설계 기법 연구)

  • Yoon, Seung-Hyun;Park, Nam-Hee;Choi, Jin-Won
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.187-192
    • /
    • 2009
  • Nowadays, global warming and high oil prices were a threat to the survival of the whole human race. One of a solution to respond to these problems is to reduce energy consumption of building. By adopting energy-saving design, the dissemination of low energy building is required. Therefore, to improve energy efficiency while reducing the usage of the design method is necessary to study actively. BIM-based systems applied to buildings, scheduled to be built by reducing the amount of energy reduction technologies can be analyzed. Depending on various design and equipment to set energy savings goals, you can select an alternative. If it is possible to predict the energy efficiency from the initial stage of design and support designing low energy building, we would be able to expect improvement in the economics of housing due to the reduction of energy consumption.

  • PDF

The Impact of Environmental Regulation on Korea and Japan's Exports of Renewable Energy and Energy Saving Industry (환경규제가 재생에너지 및 에너지절감산업의 수출에 미치는 영향 : 한국과 일본의 비교연구)

  • Shim, Kieun;Jeong, Kyounghwa
    • Environmental and Resource Economics Review
    • /
    • v.18 no.1
    • /
    • pp.75-103
    • /
    • 2009
  • The hypothesis suggested by Porter and van der Linde claims that innovating firms operate in a dynamic competitive situation which allows global diffusion of environmental-friendly technologies. Therefore, countries that are subjects to more stringent environmental regulations may become net exporters of environmental technologies. In the context of Porter hypothesis, this study investigates the impact of importing countries' environmental regulation on Korea and Japan's export flows of technologies for renewable energies and energy efficiency by estimating the gravity equation. The estimation result shows that : (1) our results are consistent with the Porter hypothesis where environmental regulation represents a significant source of comparative advantages, (2) Korea's export flows of technologies for renewable energies and energy efficiency with respect to the importing countries' environmental regulation are more sensitive than Japan's, and (3) the adverse relationship between export flows and importers' environmental stringency in developing countries does not hold in the renewable energies and energy efficiency related sector.

  • PDF

Per-Charge Range-Testing Method for Two-Wheeled Electric Vehicles (주행모드에 따른 전기이륜차의 1회충전주행거리 시험방법에 관한 연구)

  • Kil, Bum Soo;Kim, Gang Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • For testing a two-wheeled vehicle's per-charge range, this study conducted road and chassis dynamometer driving tests. Three typical road routes within Daejeon Metropolitan City were selected for the road-driving test. In the case of CVS-40 mode driving tests using a chassis dynamometer, various road-loading conditions were set. In this study, two-wheeled electric vehicles' per charge range on the road was confirmed through testing, and the range and energy consumption efficiency depending on various chassis dynamometer road load settings were measured. Then, the results of the actual road driving tests were compared with those of the chassis dynamometer driving tests, and road load settings that yielded per-charge range testing results similar to those under actual road driving conditions in the chassis dynamometer experiments were studied.

A Study on the Boiler Efficiency through the puliverizer classifier improvement of New Fossil Power Plant (화력발전소의 미분기 미분도 조정장치 개조을 통한 보일러 효율의 평가에 관한 연구)

  • Kweon, Y.S.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.721-725
    • /
    • 2001
  • The main reason for applying pulverizer classifier-rotary type in fossil power plant is boiler high efficiency and energy saving movement in the government. This study intends to analyze the boiler efficiency through the pulverizer classifier-rotary type improvement in thermal power plant and makes its comparison to that of the used fixed type.

  • PDF

A Study on the Turbine Efficiency through the shaft packing improvement of New Fossil Power Plant (화력발전소의 축밀봉장치의 개선을 통한 터빈효율의 평가에 관한 연구)

  • Kweon, Y.S.;Suh, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.715-720
    • /
    • 2001
  • The main reason for applying positive pressure variable clearance packing in fossil power plant is high efficiency and energy saving movement in the government. This study intends to analyze the turbine efficiency through the shaft packing improvement in thermal power plant and makes its comparison to that of the used packing.

  • PDF

A Study on the Building Energy Efficiency Rating Changes by Enhanced Thermal Insulation Performance of Building Envelope Standards in Apartment Houses (공동주택에서 외피단열성능기준 강화에 따른 건축물에너지 효율등급 변화에 관한 연구)

  • Cho, Yeong Uk;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • This study aimed to compare the primary heating energy consumption of regional apartment houses based on the enhanced thermal insulation performance of building envelope standards. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the southern region, the largest regional difference in primary heating energy consumption, is $10.3kWh/(m^2{\cdot}year)$. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the central region is $8.0{\sim}8.5kWh/(m^2{\cdot}year)$ and that of the Jeju region is $0.5kWh/(m^2{\cdot}year)$. These energy consumption differences do not result in building energy efficiency ratings changing. The building energy efficiency ratings have the possibility to be changed.

Evaluating Performance of Energy Conservation Measures for Remodeling Educational Facilities - Focused on Deteriorated Middle School Buildings - (교육시설 리모델링을 위한 에너지 절감 요소기술의 성능 평가 - 노후 중학교 건물 중심으로 -)

  • Lhee, Sang-Choon;Choi, Young-Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.105-110
    • /
    • 2012
  • Recently, all of the world are facing with a serious environmental crisis of global warming due to excessive energy consumptions. The Korean Government, taking over 97% of dependence on foreign energy, has made various efforts on reducing energy and greenhouse gas emission under the motto of "Low-Carbon Green Growth". Since the building sector takes 24% of domestic energy consumption, many design standards and regulations on saving energy in new buildings have been established. However, applications of energy saving designs and techniques on the remodeling process at deteriorated buildings including educational ones have been lack. Under a situation where the number of deteriorated schools accounts for up to 50%, this paper evaluated the performances of factors for reducing energy at deteriorated middle school buildings through an energy simulation tool on a standard school model. As a result, among factors of insulation, window's SHGC, southern louver, indoor setup temperature, and system efficiency, all other factors except window's SHGC and southern louver proved contribute to reduce energy at deteriorated middle school buildings, compared with the baseline energy consumption.

Case Studies of best practices through Energy audit (에너지진단 우수 사례소개)

  • Um, Chul-Jun;Song, Euy;Kim, Chun-Yong;Kim, Doo-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.505-510
    • /
    • 2008
  • Improving energy efficiency is the important thing of energy saving strategies that was shown up result of IEA meeting and the G8 Summit. Energy audit was started in 2006 that Korea government policy for improving energy efficiency. Who used over 2,000toe/yr(tons of oil equivalent per year) energy consumption has to perform energy audit program of obligation every five years with auditing company. HANMI C&E as a company authorized by Government has diagnosed various type building. This case studies are chosen to best practices by KEMCO. This studies present efficient recommendation methods for improving system performance.

  • PDF

A Case Study of Electricity Usage Monitoring for Deterioration and Economic Analysis of Main Equipment in University Laboratory

  • Park, Jun-Young;Lee, Chun-Kyong;Park, Tae-Keun
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.706-707
    • /
    • 2015
  • Our country is aiming at 30% reductions in building energy consumption accounting for 39% of the total energy consumption by 2020[1]. For this purpose, the government is developing and applying the Building Energy Management System (hereinafter, referred to as "BEMS", Smart plug, etc.) while the researches on new renewable energy development. BEMS, which is applied with focus on large buildings, is inducing energy management of the entire building through energy measurement and data management, but considering its economic efficiency, it's very difficult to apply BEMS to small & medium-size buildings. Hereupon, this study intends to implement the case analysis of deterioration and economic efficiency of major equipment in buildings on the basis of electricity consumption which has been measured targeting small & medium-size buildings for a certain period by taking into account that equipment deterioration is a contributor to the increase in energy consumption.

  • PDF

Evaluation of the Energy Efficiency of the Air Engine (공기 엔진의 에너지 효율 평가)

  • Park, Jaehyeon;Baek, Jehyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.5
    • /
    • pp.494-501
    • /
    • 2015
  • Nowadays, many people are trying to develop eco-friendly engines such as the electric motor and the air engine because the I.C. engine cause a lot of pollutants. Nevertheless of these effort, there are few evaluation and comparison of these engines to conventionally used I.C. engines. Because of this, it is difficult to determine that the eco-friendly engines are really energy saving engines. In this paper, the efficiency of the air engine is calculated. The air engine does not cause environmental pollution problem because it uses "Compressed air". Due to the air engine operated at a low temperature and spark-free condition, this engine can be used in extreme condition for safety. Despite the many advantages of the air engine, there are few analysis on the air engine because of an air engine is low energy density.