• Title/Summary/Keyword: energy saving control

Search Result 705, Processing Time 0.029 seconds

Energy Saving Effects of Carbon Nano Heating Pipe for Heating of Greenhouse (탄소나노히팅파이프를 이용한 온실 난방에너지 절감효과)

  • Paek, Y.;Jeon, J.G.;Yun, N.K.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.107-111
    • /
    • 2011
  • This carbon nano heating system was consisted of power supply equipment, a carbon fiber and a stainless flexible hose. carbon nano heating system was manufactured by carbon fiber of a power capacity 30kw/h and light-oil hot air heater in control plot was the heating capacity 30,000kcal/h, As the result, Temperature difference due to carbon nano heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, comparison greenhouse were $14.8^{\circ}C$, $13.4^{\circ}C$ respectively. It was found that carbon nano heating system and light-oil hot air heater heating cost were 1,095,740won, 2,683,628won. therefore as heating cost saving 60%. Yield of tomatoes cultured in greenhouse using carbon nano heating pipe was 4% inclease. Economic analysis comparison between the carbon nano heating pipe and the hot air heater in greenhouse were 41% respectively.

Development of Heat Control Valve Using SMA and Remote Controller for House Heating System (형상기억합금을 이용한 난방용 온도조절 밸브 및 원격 제어장치 개발)

  • Choi, Jeongju;Yeom, Jeongkuk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.2
    • /
    • pp.6-11
    • /
    • 2010
  • For the purpose of reducing the energy consumption in the house heating, the various devices have been developed. One of these is to control the flow in the heat pipe and the flow control valve using shape memory alloy(SMA) spring is proposed in our study. The proposed house heating system is to save the gas consumption and the remote control system is designed for the convenience of using the proposed valve. The developed valve consists of SMA spring, disk, return spring, and regulation handle. The regulation handle is for supplying the additional hot water and is controlled by remote-control-motor. In order to design the remote control system, the Zigbee wireless communication protocol is used. The performance of the proposed valve structure is shown through the experimental result.

Economical Efficiency of Thermal Tunnel Using Automatic Rolling Shutter (비닐권취용 자동셔터를 이용한 보온터널의 경제성)

  • Yoo, Young-Sun;Kang, Geum-Chun;Kim, Young-Joong;Baek, Yi;Jang, Chun-Hwan
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2002.11a
    • /
    • pp.298-305
    • /
    • 2002
  • 우리나라의 시설농업을 고부가가치 산업으로 발전시키기 위해서는 우선 우수한 품종의 육성과 효율적인 재배관리기술의 개발이 이루어져야 하며, 그 다음으로는 노력비, 난방비 등의 절감을 위한 기계기술의 개발이 뒤따라야 한다. 시설재배 농민의 대부분이 고령화되고 있으며, 난방비가 생산비의 20-40%를 차지하고 있는 실정을 고려한다면 노동력과 난방비 절감기술의 개발은 동시에 이루어져야 할 과제라 할 수 있다. (중략)

  • PDF

Optimal Scheduling of Ice Storage System with Prediction of Cooling Loads (예측 냉방부하를 이용한 빙축열시스템의 최적 운전계획)

  • 이경호;최병윤;주용진;이상렬;한승호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.982-993
    • /
    • 2000
  • This paper describes an optimal control scheduling of an encapsulated ice storage system with a chiller of nominal chiller 34RT(103,200kcal/hr) and an ice storage tank of 170RT-hrs(514,080 kcal). The optimization technique used in the study is dynamic programing. The objective function is summed cost during a day including charge and discharge periods. Control strategies being used commercially are chiller priority and storage priority control. In chiller priority control, the chiller is allowed to run at full capacity during the day, subject to limitations of the building load, and the ice is only melted when and if the load exceeds the chillers full capacity. In contrast to chiller priority control, the aim in storage priority control is to melt as much as ice as possible during the day time period. The system simulation calculates the operation costs for the three control strategies in the condition of the same cooling load and the same ice storage system. The simulation period is a day, assuming that initially the tank is stored fully and the cooling load is perfectly predicted for the scheduling. Also Final state of the tank is to be charged fully.

  • PDF

Automatic setting of delay time of an occupancy sensor using an adder circuit (인체감지 센서의 시간지연 설정)

  • 정영훈;송상빈;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.162-165
    • /
    • 1998
  • A certain degree of energy saving can be possible by controlling the delay time of occupancy sensor. In this paper a control circuit is designed for automatic control of delay time setting appropriate to different situations using a digital counter, two latches and an adder. The delay time is controlled by adjusting the time constant of RC circuit through on-off control of switching devices according to adder output, which determines the base current level of switching devices. And from PSpice simulation it is verified to function properly.

  • PDF

Proposal of the Prediction Equation for Interior Daylight Illuminance (실내 주광조도 분포 예측식의 제안 및 검증)

  • Park, Woong-Kyu;Park, Tae-Ju;Kang, Gyu-Min;Lee, Sang-Yup;Song, Doosam
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.3
    • /
    • pp.114-123
    • /
    • 2013
  • In these days, most of the office buildings are being required to save energy for maintenance. lighting system constitutes 20% to 30% of the total annual electrical energy consumption in office buildings. As an energy saving strategy for lighting system, dimming control system based on illuminance sensors came into use. But the system is accompanied with many illuminance sensors to control lighting and needs a lot of initial investment. In this study, the prediction equation for indoor daylighting illuminance distribution is proposed through the review for conventional research results and field measurements. The proposed equation was verified by the comparison between predicted results and field measurement results. The developed prediction equation for daylighting can be used to control the indoor illuminance level with the limited sensor when dimming control system is operated.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

A Controller Design of the Bilinear System for HVAC(Heating, Ventilating and Air-conditioning) System (냉난방 시스템의 이중선형 시스템에 관한 제어기 설계)

  • 이정석;강민수;김명호;이기서
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.4
    • /
    • pp.177-184
    • /
    • 2000
  • In this paper, a HVAC controller which has a bilinear system is designed to control the air temperature in building room and a saving of energy on the HVAC system. For modeling of the HVAC bilinear system, AHU(Air Handling Unit) is modeled on the control of inside-outside air flow using three dampers in a duct. A heat exchanger and the single room are also modeled by the energy conservation law. Under the modeling of the HVAC bilinear system, the control's law of the bilinear HVAC system is derived by Lyapunov's non-linear theory and Deress's the linear feedback laws for bilinear system. In this paper it was proved that the controller of the HVAC bilinear system is able to control the air temperature with a disturbance in order to get a target of temperature in the building room by the computer simulation when the control inputs regulate the air flow rate and a capacity of the heat exchanger.

  • PDF

A study on Energy Saving of the Excavator using Electro-Hydraulic Actuator (전기-유압 액추에이터를 이용한 굴삭기 에너지 절감에 관한 기초 연구)

  • Yoon, Hong-Soo;Ahan, Kyung-Kwan;Lee, Byung-Lyong;Kang, Jong-Min;Kim, Jae-Hong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.801-805
    • /
    • 2008
  • Today, hydraulic systems play an important role in modern industry for the reasons that hydraulic actuator systems take many advantages over other technologies with high durability and the ability to produce large forces at high speeds. In recent years, electro-hydraulic actuator systems, which combine electric and hydraulic technology into a compact unit, have been adapted to a wide variety of force, speed and torque requirements. Moreover these systems resolve energy consumption and noise problems characteristic existed in the conventional hydraulic systems. Therefore, these systems have a wide range application fields especially in an excavator. So the purpose of this paper is to demonstrate efficiency of the energy saving and present some control algorithms which apply to electro-hydraulic actuator system in the bucket of the excavator. Experiments are carried out to verify the effectiveness of the proposed system with various external loads as in real working conditions.

  • PDF