• Title/Summary/Keyword: energy saving control

Search Result 706, Processing Time 0.026 seconds

Design of Predictive Controller for Effective Superheat Control of Variable Speed Refrigeration System (가변속냉동시스템의 효율적인 과열도제어를 위한 예측제어기 설계)

  • Choi, Jeong-Pil;Hua, Li;Jeong, Seok-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.9-15
    • /
    • 2008
  • In this paper, we suggest PI control with a predictive controller to progress both energy saving and coefficient of performance(COP) in a variable speed refrigeration system. The capacity and superheat are controlled simultaneously and independently by an inverter and an electronic expansion valve respectively for saving energy and improving COP in the system. The refrigeration system has long dead time in superheat inherently. The dead time makes the system difficult to achieve the satisfactory quick control response, especially superheat control response. In order to solve this problem, we designed a predictive controller based on PI control to progress superheat control performance. The control performance was investigated through some experiments to verify the effectiveness of the predictive controller.

  • PDF

Energy Saving Smart Illuminating System Implementation Based on Obstacle Environment Presetting (장애환경설정 기반의 에너지절약 지능형 조명시스템 구현)

  • Kim, Young Bin;Ryu, Conan K.R.
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2786-2791
    • /
    • 2014
  • This paper describes the smart illuminating system based on the obstacle environmental presetting to improve the user convenience to easy lighting and energy conservation. Obstacle environment has trouble controlling the illuminating equipment using manual buttons in certain circumstances, which requires a smart remote controller. The smart remote controller is operated by the smart phone, motion sensor and timer to turn on and off the lamps. The event sensor module transmits the signals of the event occurrence to equipment on the remote place when smart phone and motion sensor detect an event, and the illuminator received the event turn on or off the lamp. The system results in energy saving by simple on/off control and manipulating the operating time with controlling the illuminating system preset by user's obstacle or preference circumstances. The proposed system implementation is experimented to figure out the energy saving about13.5w/h and the optimized convenience control.

Review of New Technologies' Energy Conservation Rate in High-Performance Buildings (High-Performance Buildings 구현을 위한 신기술 연구 동향 및 에너지 절감 효과 평가)

  • Kim, Chul-Ho;Yang, Ja-Kang;Lee, Seung-Eon;Yu, Ki-Hyung;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2016
  • Purpose: The purpose of this study is to analyze the energy performance by applying new technologies for passive and active control. Method: We selected new technologies for passive and active control which are based on formal study by analyzing technology applied to the High-Performance Buildings in various countries. Also, we analyzed energy saving potential for each technologies by breakdown the result of the energy saving rates in detail. Result: For the wall and roof insulating methods, preceding studies showed that up to 21% energy could be saved by improving roof insulation and applying proper outside insulation compared to non-insulation. For the windows and glazing system, preceding studies showed that Low-E glazing system could save up to 11% energy compared to single glazing system. Studies about solar and daylighting controls revealed that effective daylighting dimming control could save 13% of energy compared to uncontrolled situation. Studies on DOAS (Dedicated Outdoor Air System) showed that about 23% energy could be saved compared to standard VAV system. Studies on the active chilled beam showed that about 25% energy could be saved compared to standard VAV system and studies of applying UFAD (Under Floor Air Distribution) could consume 31% less energy than applying overhead system.

A Study on the Development of Power Control Wireless Interface Module for Demand_Response using IEEE1451.5 (IEEE1451.5 기반의 전원 제어용 무선 DR_인터페이스 장치 개발에 관한 연구)

  • Lee, Joung-Han;Choi, In-Ho;Ryu, Joong-Kyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.12
    • /
    • pp.1192-1196
    • /
    • 2009
  • Recently, the environment contamination problem and energy saving are the social issues. So, the Green IT based Smart Grid was suggested. The smart grid will let rates fluctuate even more dynamically, depending on conditions using energy. Thus, green IT includes the dimensions of environmental sustainability and the economics of energy efficiency. The smart controller in which it is controlled by DR in order to manage the energy consumption by using AMI is needed in order to apply its technology to the real life. In this paper, DR_WTIM of the IEEE1451.5 base which has the DR function for connecting to AMI of the wireless base is developed. By using this apparatus for the power control system, the energy saving effect is shown. Moreover, by using the IEEE1451.5 technology, the problem of energy consumption is solved in order to apply to power controller designed for efficient use energy.

Estimation of the Energy Saving Potential using Energy Bandwidth Analysis in Manufacturing Plant (에너지 대역분석 기법을 이용한 생산플랜트에서 에너지절감 잠재량 산정)

  • Park, Hyung-Joon;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.236-240
    • /
    • 2011
  • Currently one of the most importance issues in industrial sector is energy cost and energy efficiency. The manufacturing plants especially have made many efforts to reduce energy cost by implementing maintenances. But in many cases, they are not aware that how much energy could be saved more. If we know the best energy consumption, which signifies energy baseline, we can control the intensity of maintenances. One way to obtain the baseline is using proper statistics from a specific plant, a sector of industry. Energy bandwidth signifies the gap between actual Specific Energy Consumption(SEC) of a certain plant and minimum SEC of the best plant, and estimate energy saving potential(ESP) is a result of bandwidth analysis. We chose a model plant and implemented some maintenance for a year, and then we obtained ESP. Additionally we could determine the decreased amount of carbon emissions from the plant using Carbon Emissions Factor(CEF) by Intergovernmental Panel on Climate Change(IPCC).

A Development of Intelligent Metering and Control System for Energy Management of Electric Cabinet Panel (분전반 전력관리용 지능형 계측 제어 시스템 개발)

  • Park, Byung-Chul;Park, Jae-Sung;Song, Sung-Kun;Shin, Joong-Rin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.90-97
    • /
    • 2013
  • In recent years, the many electric saving methods are studied because of difficulty of meeting the demand. The electric energy management such as monitoring of branch power consumption, demand control, metering, power quality monitoring, electric safety monitoring can make energy saving. The purpose of this paper is to develop a system which can provide the integrated management of various functions required for energy management by consumers. In this system all functions which were embodied into each devices are integrated into intelligent meter. The developed systems are tested and implemented by installing at consumer electric distribution panel.

Energy Saving in Boom Motion of Excavators using IMV (IMV를 사용한 유압굴삭기 붐 동작의 에너지 절감)

  • Huh, Jun Young
    • Journal of Drive and Control
    • /
    • v.14 no.3
    • /
    • pp.1-7
    • /
    • 2017
  • Energy consumption of conventional hydraulic excavators controlled by MCV is considerable when negative load is applied because the meter orifice and meter-out orifice are machined in one spool. Therefore, IMV is introduced to save energy use of hydraulic excavators, but existing hydraulic excavators have various advantages so it is difficult to make a clear comparison. In this study, we compare the use of an existing MCV excavator that has many advantages such as negative control, and IMV for boom up and down operation, and if IMV is used to save energy, we will examine the cause. If possible, for comparability under the same conditions, both systems use pressure balance valves to minimize power consumption when not using power in the actuator. The orifice area at each notch of each valve is calculated, and energy saving is verified by comparing the two systems through simulation.

An Experimental Study on Semiconductor Process Chiller for Dual Channel (듀얼채널을 적용한 반도체공정용 칠러의 실험적 연구)

  • Cha, Dong-An;Kwon, Oh-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.760-766
    • /
    • 2010
  • Excessive heat occurs during semiconductor manufacturing process. Thus, precise control of temperature is required to maintain constant chamber-temperature and also wafer-temperature in the chamber. Compared to an industrial chiller, semiconductor chiller's power consumption is very high due to its continuous operation for a year. Considering the high power consumption, it is necessary to develop an energy efficient chiller by optimizing operation control. Therefore, in this study, a semiconductor chiller is experimentally investigated to suggest energy-saving direction by conducting load change, temperature rise and fall and control precision experiments. The experimental study shows the cooling capacity of dual-channel chiller rises over 30% comparing to the conventional chiller. The time and power consumption in the temperature rising experiment are 43 minutes and 8.4 kWh, respectively. The control precision is the same as ${\pm}1^{\circ}C$ at $0^{\circ}C$ in any cases. However, it appears that the dual channel's control precision improves to ${\pm}0.5^{\circ}C$ when the setting temperature is over $30^{\circ}C$.

Improving Cooling System for Energy Saving in Composite Plant

  • Promwong, Pissanu;Chaikla, Amphawan;Masuchun, Ruedee;Chansangsuk, Dumri;Julsereewong, Prasit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.730-735
    • /
    • 2004
  • This paper describes an improving cooling system in the composite plant. In order to save the energy, a plate-and-frame heat exchanger has been used to replace the traditional worm cooler. The composite plant in Thailand was studied as an illustrative case study. The experimental results demonstrating the saving in energy costs and some economic benefits of the proposed technique are obtained.

  • PDF

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.2
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.