• Title/Summary/Keyword: energy monitoring and management

Search Result 385, Processing Time 0.03 seconds

Study on Indoor Air Pollutants of Public Service Centers in Winter, Seoul (서울지역 공공청사 민원실의 겨울철 실내공기질에 관한 연구)

  • Jeon, Jea-Sik;Kim, Mi-Hyung;Lee, Ju-Yeol;Jeon, Myung-Jin;Ryu, In-Cheol;Park, Duck-Shin;Choi, Han-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.569-579
    • /
    • 2011
  • This study evaluated the indoor air quality of 26 government offices located in Seoul. The pollutant samples were taken from Jan. 13th to Jan. 29th and Feb. 20th to Feb. 23rd, 2010 in the offices. The target indoor pollutants for this study were $PM_{10}$, formaldehyde, carbon monoxide, carbon dioxide, total bacteria counts, total volatile organic compounds, radon, nitrogen dioxide, ozone, and asbestos which were controlled by the indoor air quality law for the multiple-use facilities management. The results of this study showed that some pollutants of the 38.5% offices exceeded the standards of the air quality guideline. The correlation analysis of the same pollutants between indoor and outdoor represented that $NO_2$ (r=0.629, p<0.05) and $O_3$ (r=0.459, p<0.01) were significant, however, $PM_{10}$ and CO were not. The correlation analysis between different pollutants showed that CO and TVOC (total volatile organic compounds: r=0.724; p<0.01), CO and $NO_2$ (r=0.674; p<0.01), HCHO and humidity (r=0.605; p<0.01), $CO_2$ and TVOC (r=0.534; p<0.01), TBC (total bacteria counts) and Asbestos (r=0.520; p<0.01) were significant. The energy-saving system of government buildings in winter caused under-ventilated and poor air quality. This study suggests that the concentrations of radon and $CO_2$ should be used as an indicator for monitoring indoor air quality and maintaining effective ventilations.

Recent Developments and Field Application of Foreign Waterworks Automatic Meter Reading (국외 상수도 원격검침시스템의 개발 동향 및 현장 적용 사례 고찰)

  • Joo, Jin Chul;Ahn, Hosang;Ahn, Chang Hyuk;Ko, Kyung-Rok;Oh, Hyun-Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.863-870
    • /
    • 2012
  • The market trends of automatic meter reading associated with smart water meters were investigated. Also, recent developments and field applications of key technology for automatic meter reading associated with smart water meters were analyzed. Smart water meters have been manufactured mostly in United States and Europe and have been expanded their business to Asia. Integrated water management system combining with the additional functions such as real-time consumption metering, cost notification, water conservation, leak detection, water quality monitoring, and flow control have been operated in automatic meter reading. Both water quality and quantity data measured from smart water meters and sensors were transferred to data concentration units through neighborhood area network, and then were transferred to integrated server through wide area network. The data transfer methods were determined by comprehensively considering urban scale, density of smart water meters, power supply and network topologies. Common data collection methods such as fixed network to data concentation units, vehicles drive by, people walk by, and drone fly by have been applied. The automatic meter reading associated with smart water meters are spread throughout the world, and both water and energy savings result in saving the money and reducing the greenhouse gases emission.

UNLEADED GASOLINE AND LEAD LEVEL IN HUMAN BLOOD

  • Kim, Dae-Seon;Cha, Joung-Hoon
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2001.11a
    • /
    • pp.30-41
    • /
    • 2001
  • Rapid economic development and industrialization has been accompanied by an increase of energy demand and environmental pollution. The consumption of gasoline has increased totally, but decreased in use of leaded gasoline after 1988 in Korea. On the other hand, risk assessment of environmental pollutants requires reliable dose estimates. Source oriented monitoring is not providing adequate information to estimate human exposure. The Health Surveillance Project has been launched in Korea from 1980, which questioned their symptoms based on questionnaires and medical examinations for inhabitants in the vicinity of 13 industrial areas and 2 non-industrial areas. 10, 598 inhabitants living in these 15 areas had medical checkups and donated their blood f3r heavy metal analysis from 1980 to 2000 through this project. Especially lead levels in inhabitants' blood of these areas were determined and monitored. Totally 4, 967 samples in target areas were used to review the trend of blood lead level in this paper. Average lead concentrations by areas were from 15.2 to 21.0 ug/dl in 1981 and 22.3 to 34.3 ug/dl in 1988, but were 8.8 to 11.1 ug/dl in 1992 and 4.4 to 4.8 ug/dl in 1995. On the other hand, the consumption of leaded gasoline was at a peak in 1958. Blood lead level showed a very close relationship with the consumption of leaded gasoline in the change pattern(p<0.01) and showed a rapid declining trend since the use of unleaded gasoline, especially from 1988 when Seoul held the olympic games. For example, the blood lead levels were 15.2 ug/dl in 1981, 20.2 ug/dl in 1955. 24.3 ug/dl in 1988 and 3.9 ug/dl in 1993 in Yochon area. China also had monitored blood lead levels of general population. 7, 015 inhabitants living in 28 areas donated their blood far heavy metal analysis from 1981 to 1988. Average lead concentrations by areas were from 5.1 to 5.6 ug/dl before. 1984 but were form 2.8 to 11.2 ug/dl after 1984. Average lead concentration in blood showed increasing trends clearly in most of the areas. The recent policy of unleaded gasoline use for automobile will be a very beneficial policy for the management of atmospheric lead pollution & health risk assessment for the general population in China. It is recommended that it should be propelled more widely and rapidly to the entire country.

  • PDF

The Availability Examination for Vegetation Measurement of The SLR Digital Camera (SLR 디지털카메라의 식생관측센서로서의 유효성 검토)

  • Kim, Jong-Hwan;Kim, Eung-Nam;Jun, Byung-Dug;K., Sugiyama
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.1
    • /
    • pp.683-692
    • /
    • 2009
  • On-site remote sensing technique by using single lens reflex(SLR) digital camera will be expected as the useful tool for the vegetation measurement field such as a crop growth management, the monitoring of revegetation slope and the evaluation of environment. We reviewed the availability of the vegetation measurement using a digital camera which is sailed for general-purpose. As a result, we could analysis relationship with the illuminance of image plane and incidence energy of multitemporal observation images by doing gamma correction and exposure compensation. And also, we proposed the model formulas for the correction of influences of capturing angle and illuminance. In addition, we obtained high correlation of normalized difference vegetation index(NDVI) between digital camera and spectral photometer.

Practical Radiation Safety Control: (I) Application of Annual Limit on Intake and Derived Air Concentration (방사선안전관리 실무: (I) 연간섭취한도와 유도공기중농도의 적용)

  • Kim, Hyun Kee
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.234-236
    • /
    • 2013
  • Some of radioactive contamination is unavoidable in the facilities using the unsealed radioactive material. The primary purpose of radioactive contamination control in the workplace with contamination concern is the effects from the potential intake of radioactive material into the body. This paper provides procedures to estimate the level of internal exposure for the worker based on the conservative assumptions and simple calculations. They consist of two processes; to calculate air concentration of radioactive material and annual intake by inhalation with contaminated air and to compare each of them to Derived Air Concentration and Annual Limit on Intake mentioned in the related notification. The procedures are applicable to make a decision on practical requirements for monitoring air contamination and internal exposure of worker as follows; needs for measurement of air contamination and internal exposure and acquisition of information on the design of the ventilation system.

A Study on the Rainwater Quality Monitoring and the Improvement, Collection and Storage System (빗물 집수 및 저장 시스템 개선과 수질 분석 모니터링)

  • Kim, Chul-Kyung
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.353-362
    • /
    • 2011
  • In our nature, the utilization of rainwater is essential for healthy water recirculation. This is one of the solutions of the increment of impermeability surface according to the development of new cities; this study of the improvement of rainwater quality has been carried on through the improvement of collecting and restoring system of rainwater. The southwestern region of Daejeon City, the rainwater coefficient of run off was 0.40 and this number had computed to 0.59 after the development. After filtration of rainwater, the heavy metal (Cu, As, Cr, Fe, Mn) contents level were lower than underground water. Moreover, collected rainwater showed better quality than underground water in following criteria; hardness, permanganate consumption quality, chloride, evaporation residue, sulfates and nitrate nitrogen. This water quality met the gray water quality standards. The rainwater quality was still suitable to use as bathroom flushing and gardening after 100 days of storage. This study proved that modification (installation of cover with gutter to existing rainwater collection system, proper filtering, and installation of underground storage tank) of collection system could improve quality of water and maintain this approximately 100 days.

Dependence of Total and Carbonaceous Aerosol Concentrations on Transport Pathways in Seoul, Korea (공기 궤 유입경로에 따른 한반도 서울 상공의 전체 및 유기 에어로졸 농도 변화 분석)

  • Jeong, Ukkeo;Kim, Jhoon;Kim, Young J.;Jung, Jinsang
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.141-148
    • /
    • 2015
  • Recently increased anthropogenic aerosols change the radiative energy balance and affect human life. The management of air quality requires monitoring both the local emissions and transported pollutants. In order to estimate the quantitative contribution of long-range transport from remote sources on aerosol concentrations in Seoul, the airmasses were classified into five types with respect to their pathways. When airmass came from west over strong emission regions in China, high concentrations of $PM_{10}$, $PM_{2.5}$, black carbon (BC), organic carbon (OC), and elemental carbon (EC) were found, even higher than those for the stagnated airmass. High OC concentrations were found when airmass came from north while BC, EC, and $PM_{2.5}$ concentrations were lower than those of the stagnated airmasses. During dust events, the $PM_{2.5}$ and $PM_{10}$ concentrations increased significantly while carbonaceous aerosol concentrations did not increased. The temporal variations of aerosol concentrations in Seoul were affected by the seasonal variations of airmass pathways. The high $PM_{2.5}$ concentrations over $100{\mu}g\;m^{-3}$ appeared most frequently when the airmasses came from west.

Smart Outlet System for Single-person Household based on IoT (Internet of Things) (사물 인터넷 기반의 1인 가구를 위한 스마트 콘센트 시스템)

  • Kim, Hye-Suk;Park, Byeong-Ju;Cho, Young-Ju
    • Journal of Digital Contents Society
    • /
    • v.18 no.5
    • /
    • pp.895-904
    • /
    • 2017
  • In this paper, we propose an IoT based smart outlet system for one-person household with electric safety, electric energy consumption management and transmission of messages to the reserved contacts by connecting the emergency network. The proposed smart outlet system is implemented by parsing packet data and protocol between server, module, application and WiFi AP receiver. The WiFi AP built for communication can be used not only for the outlet but also for the gas barrier, the door lock and the like. In addition, the proposed method can provide the remote monitoring function by receiving the amount of power of the receptacle received through the AC current sensor (SCT-013) in real time. The smart outlet system is expected to be capable of automatically shutting off the power in case of emergency through automatic power use analysis in addition to the standby power cutoff function.

Development of an Objective Judgement Procedure for Determining Involvement of Violation-Type Unsafe Acts caused Industrial Accidents (사고 유발 불안전행동의 위반 여부에 대한 객관적 판단절차 개발)

  • Lim, Hyeon Kyo;Ham, Seung Eon;Bak, Geon Yeong;Lee, Yong Hee
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.35-42
    • /
    • 2022
  • When an accident occurs, the associated human activity is typically regarded as a "human error," or a temporal deviation. On the other hand, if the accident results in a serious loss or if it evokes a social issue, the person determined to be responsible may be punished with a "violation" of related laws or regulations. However, as Heinrich stated, it is neither appropriate nor reasonable in terms of probability theory and cognitive science to distinguish whether it is a "human error" or a "violation" with a criterion of resultant accident severity. Nonetheless, some in society get on the social climate to strengthen regulations on workers who have caused accidents, especially violations. This response can present a social issue due to the lack of systematic judgment procedure which distinguishes violations from human errors. The purpose of this study was to develop an objective and systematic procedure to assess whether workers' activities which induced industrial accidents should be categorized as violations rather than human errors. Various analysis techniques for the determination of violation procedure were investigated and compared using an analysis approach method. An appropriate technique was not found, however, for judging the culpability of intentional violations. As an alternative, this study developed the process of creating violations, based on cognitive procedure, as well as the criteria to determine and categorize an activity as a violation. In addition, the developed procedure was applied to cases of industrial accidents and nuclear power plant issues to test its practical applicability. The study demonstrated that the proposed model could be used to determine the existence of a violation even in the case of multiple workers who work simultaneously.

Management of Osteoporosis in Liver Transplant Recipients (간이식 후 골다공증 관리)

  • Choi, Hojeong;Kim, Boram;Kim, Yoonhee;Lee, Jungwha;Lee, Eunsook;Lee, Euni;Cho, Jai Young;Choi, YoungRok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.30 no.1
    • /
    • pp.51-58
    • /
    • 2020
  • Background: Prevention of osteoporosis and bone fracture is one of the important issues for liver transplant recipients because a long history of liver disease and lifelong use of immunosuppressants, including corticosteroids, may cause these diseases. In this study, we aimed to analyze liver recipient bone status, 10-year fracture risk, and medication history. Methods: The electronic medical records of adult patients aged >40 years who received liver transplantation at Seoul National University Bundang Hospital between January 2009 and June 2017 were reviewed retrospectively. On the basis of their bone mineral density and fracture history, their fracture risks were analyzed using the Korean fracture risk assessment tool. Results: A total of 57 liver transplant recipients were treated with corticosteroids during a mean of 8.8 months after transplantation. 30 patients (52.6%) showed bone metabolism dysfunction such as osteopenia or osteoporosis. The 10-year femoral fracture risk was 2.1%, and dual-energy X-ray absorptiometry monitoring was performed, including right before liver transplantation every 27.5±19.2 months. The mean femoral bone mineral density decreased by -7.2%±7.3%. Four patients (7.0%) had a fracture after liver transplantation. Osteoporotic fracture occurred in 3 patients with osteoporosis (25.0%). Among the osteopenia patients with moderate fracture risk who were not treated with bisphosphonate, 1 patient (12.5%) had a history of bone fracture after liver transplantation. Conclusions: Considering the deterioration of bone density and moderate fracture risk, medication for osteoporosis should be prescribed to liver transplant recipients with regular monitoring of bone density after transplantation.