• 제목/요약/키워드: energy meter

검색결과 362건 처리시간 0.028초

평면식 태양열집열기를 이용한 곡물 건조개선에 관한 연구 (A Study on the Performance of Flat-plate Solar Air Collector and its Application to Grain Drying)

  • 민영봉;최규홍
    • Journal of Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.114-125
    • /
    • 1978
  • The use of petroleum fuels in grain drying causes problems of high cost and management. To solve these problems, it is required to study on soLar energy as an alternative to petroleum fuels for grain drying. The purposes of this study were to find out the optimum received area and air flow rate of a flat-plate solar air collector for grain drying and to assess its effects on grain drying with a small grain bin. The results of this study are summarized as follows ; 1. The calculated optimum tilt angles of the collector in the summer and autumn drying seasons were 20 and 50 degress, respectively, in suwon area. 2. The outlet temperature of the collector was $36^\circ C$ on the daily average with the maximum of $36^\circ C$ at 12:00 o clock. Solar radiation on the collector surface was 1.04 ly( 1 langley = 1 cal/$cm^2$) per minute on the daily average and 1.30 ly per minute on the maximum at 11:00am. The thermal efficiency of the collector was 62.4 percent on the daily average, and the air flow-rate per unit receiving are was 1.03 $m^3$/min/$m^2$.4. The calculated optimum receiving area and the air flow-rate per unit cubic volume for paddy in autumn drying season was 2 $m^2$ and 2$m^3$/min , respectively. 5. not significantly difference in the collector efficiency was appeared between the rotating and fixed type of solar collector. 6. For drying of wheat with 0.6 meter of the depth in the bin, approximately 9 hours were required to reduce the moisture content from 21.6% to 13% with air follow rate of 5 $m^3$/min an initial moisture per cubic meter of wheat and with air temperature of $52^\circ C$. 7. In the drying test of rough rice with a turning operation in a grain bin approximately 21 hours were required to reduced the moisture from 21% to 14.5% with airflow rate of 2 $m^3$/min per cubic meter of rice and the air temperature of $43.5^\circ C$. 8. Over-drying at the bottom and less -drying at the top of the grain mass was resulted from the high -temperature of drying air which was obtained from the flat-plate solar collector in this test. An appropriate operation should be prepared for the uniform moisture of the grain in the bin.

  • PDF

소규모 마이크로그리드에서 프로슈머관리시스템의 구현 (Implementation of Prosumer Management System for Small MicroGrid)

  • 임수연;이태원
    • 한국정보전자통신기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.590-596
    • /
    • 2020
  • 상용전력망과 계통연계가 어려운 도서지역에서는 독립적인 마이크로그리드로 생산된 에너지를 효율적으로 관리할 수 있는 방법을 찾는 것은 매우 중요한 일이다. 본 논문에서는 태양광과 풍력의 하이브리드 모델을 적용한 소규모 마이크로그리드에서 생산된 전력을 전력계측기와 수집된 데이터의 응답속도 테스트를 거쳐 P2P전력거래를 위한 프로슈머관리시스템을 구현하였다. 마이크로그리드 프로슈머 관리시스템의 전력망은 Mesh구조로 이루어져 있으며 P2P전력거래는 3곳의 독립적으로 구축된 off-grid 사이트에서 전력계측기와 DC전력전송기를 이용하여 테스트하였고, 이때 전력계측기의 측정값은 전압(평균값) : 380V + 0.9V, 전류(평균값) : + 0.01A, 전력 : 1000W ( - 1W)로 오차 허용범위인 ±1%이내로 나타나 그 유의성을 확인하였다. 실시간으로 50개의 데이터를 동시 전송하여 메인화면 0.32초, 일 발전량 2.61초, 누적발전량 2.77초, 전력거래 0.11초 등의 응답속도가 나타나 서버의 안정화를 확인하였다. 따라서 본 시스템은 한국전력의 중계 없이 독립적인 망으로 활용될 수 있는 P2P 전력거래시스템으로서 그 타당성이 입증되었다.

수소 충전소 계량오차 검증 설비 설치를 위한 위험성 분석 사례 연구 (A Case Study on the Risk Analysis for the Installation of Measurement Error Verification Facility in Hydrogen Refueling Station)

  • 이화영;장현우;이민경;김정환;이재훈
    • 한국가스학회지
    • /
    • 제26권6호
    • /
    • pp.30-36
    • /
    • 2022
  • 수소 충전소를 이용한 에너지원의 상거래에 있어 부정확한 계량에 의한 과 충전 등의 사고 예방과 정확한 계량을 통한 수소 상거래의 투명성 확보를 위해서는 높은 정확도의 유량계가 필요하다. 본 연구에서는 코리올리 방식 유량계 시작품을 개발하였으며, 계량 성능 검증을 위하여 기존에 운영 중인 충전소를 대상으로 공정변경을 통한 계량 성능 비교 실험 중 발생할 수 있는 사고의 예방을 위하여 위험성 평가를 수행하였다. 실증실험용 계량설비 설치를 위한 공정 변경 구간을 정의하고 HAZOP을 실시하였다. 또한 실증 실험 중 밸브오 개방 예방 등 실험자 안전성 확보를 위한 JSA도 병행하였다. HAZOP을 통하여 도출된 위험 요소를 개선하기 위한 방안을 수립하였으며 JSA를 통해 인적오류를 최소화하고 작업자의 안전성 확보할 수 있는 작업 절차를 수립하였다. 이와 같은 위험성 평가 결과를 반영하여 계량시스템 설치를 위한 설계 변경 및 시스템 제작을 완료하였으며 개발된 계량기 시작품의 성능비교 실험을 통해 안전성을 확인할 수 있었다. 개발된 시작품 유량계는 70MPa의 운전 조건에서 총 30회 유량 측정 실험 결과 평균 오차는 -1.58% ~ 3.96%로 나타났다. 이와 같은 계량오차는 상업용으로 설치 운영 중인 유량계와 동등 수준의 성능을 가진 것으로 분석되었다.

핵의학과 환경미화원의 일시 출입자 분류에 대한 고찰 (A study on Classification of Temporarily Access Group about Sanitation Workers in Nuclear Medicine Department)

  • 유재숙;장정찬;김호성
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.50-56
    • /
    • 2012
  • 일시 출입자로 분류된 핵의학과 출입 환경미화원은 주기적으로 타과와 업무순환을 하고, 또한 작업 시간과 환경 등의 변화가 많기 때문에 관리하기에 어려운 점이 있으며 따라서 이들의 분류를 명확히 할 필요가 있다. 이에 본 논문에서는 핵의학과에서 근무하는 환경미화원의 피폭 상황을 분석하여 일시 출입자로 분류된 조건의 타당성에 대하여 검토해 보고 작업 환경의 변화 및 근무 시간의 조절이 필요한가를 알아보았다. 우선 먼저 PET실과 혈액 검사실에서 근무하는 환경미화원과 감마 카메라실에서 근무하는 환경 미화원 2명을 대상으로 한 달간 근무 시간 중에 OSL을 각각 착용시켜 개인 피폭 선량을 측정하였다. 둘째로 survey meter를 이용하여 두 명의 환경미화원의 작업 환경, 근무 형태에 따라 시간대 별로 핵의학과 내 14개 구역을 선정, 총 10회 공간 선량률을 측정한 결과 이들의 피폭 선량은 연간 1mSv를 초과하지 않았으며, survey meter를 이용하여 조사한 결과 또한 연간 1 mSv를 초과하지 않을 것으로 추정되지만 그 수치가 1 mSv에 근접하였다. 따라서 일시 출입자로써의 분류를 좀 더 명확히 하기 위해서는 PET 안정실과 같은 피폭이 상대적으로 많은 구역에서의 노출 확률을 줄이기 위하여 이들에게 방사선 관리 구역내 교육을 실시하고, 또한 근무시간 및 근무 형태를 적절히 변경한다면 이들의 피폭 선량은 확연히 줄어들 것으로 사료된다.

  • PDF

의료용(醫療用) 선형가속기(線型加速器)에 의한 산난공간(散亂空間) 선량분포(線量分布)와 유도방사능(誘導放射能) (Induced Activity and Space Dose Distribution from Medical Linear Accelerator)

  • 추성실;박창윤
    • Journal of Radiation Protection and Research
    • /
    • 제11권1호
    • /
    • pp.51-56
    • /
    • 1986
  • 방사선(放射線)의 의학적(醫學的) 진단치료(診斷治療) 이용률(利用率)이 증가(增加)함에 따라 의료인(醫療人)과 환자(患者)들에 대한 방사선(放射線) 피폭확률(被曝確率)이 비예적(比例的)으로 증가(增加)되어 정량적(定量的)인 분석(分析)과 피폭관리(被曝管理)의 필요성(必要性)이 요구(要求)되고 있다. 연세(延世) 암센터는 암치료(癌治療)를 위하여 설치사용(設置使用)되고 있는 의료용(醫療用) 고(高)에너지 선형가속기(線型加速器)에 대한 누출(漏出) 및 산난선(散亂線)의 방어벽(防禦壁)과 방어계획(防禦計劃)이 이미 준비(準備)되어 있다. 그러나 장치(裝置)의 사용빈도(使用頻度)가 증가(增加)됨에 따라 치료실내(治療室內)의 공간(空間) 선량분포(線量分布)와 광핵반응(光核反應)으로 인한 유도방사능(誘導放射能)의 위험성(危險性)을 인식(認識)하고 이들에 대한 노출량(露出量)을 전리함(電離函), 열형광측정기(熱螢光測程器) 및 에너지 분석기등(分析器等)을 이용(利用)하여 측정(測定)하였다. 18 MeV 전자선(電子線)에 의한 실중선량(室中線量)은 1 m 지점(地點)에서 종양선량(腫瘍線量)의 0.02%였고 X-선(線)에 의한 실중선량(室中線量)은 약(約) 0.12%였다. 선형가속기(線型加速器)에서 10 MV X-선(線)을 30 Gy 조사(照射)한 직후 광핵반응(光核反應)에 의한 유도방사능(誘導放射能)을 측정(測定)한 결과(結果) 0.65 mR/hr 였으며 광핵반응(光核反應)에 의한 중성자(中性子) 방사화(放射化)는 주로 Cu-64, W-185, Mo-94, Ta-182등(等)의 원소(元宵)로 추정(推定)할 수 있었다.

  • PDF

토목 발파가 소음, 진동, 부유 분진에 미치는 영향 (Effects of Civil Blasting on Noise, Vibration and Total Suspended Particles)

  • 정진도;정영국
    • 한국환경과학회지
    • /
    • 제13권1호
    • /
    • pp.99-107
    • /
    • 2004
  • This research is to determine the level of environmental pollution at a blasting construction area which is the origin of noise, vibration, and suspended particle, and to compare the results with other domestic and international standard data. This experiment is also to find out the effects resulting from blasting construction and to propose a plan that can decrease environmental pollution. The blasting construction area is a factory site which is about one and half million square meter and sewage disposal plant is about ninety thousand square meter. Both were selected as the areas for the tests to be conducted in determination test. The test to determine the level of noise, vibration, and total suspended particle was conducted thirty times around the blasting construction area by comparing measurement results and numerical analysis. However, as the test was not conducted in the laboratory but in the actual blasting construction area, it was not possible to do the test with the same exact conditions each true. Therefore, the test was not ideal as conditions could change from test to test. For the most part, the level of noise was below the standard level of 70dB. Every vibration test was under the standard limitation. For example, a house, 200m away was tested for noise and vibration and the level was found to be under the 0.2 cm/sec which is the standard for specialty designed cultural sites., i.e very low level. Also a buried oil pipeline that was 30m away also marked under 2.0cm/sec which is the norm for an industrial area. However, if there were an oil pipeline under the house, the amount of charging gunpowder per hole should be decreased compared to the amount used in the test. The test result for suspended particles under the standard limitation which is 24hour average 300$\mu\textrm{g}$/㎥ at a distance from blasting wavelength, but at detonator, total suspended particle from the blast origin exceeded the standard limitation. If explosion occurs when it detonates in the hole, most of the energy would be absorbed in the crushing of rocks, but some remaining energy would make noises and vibration inevitable. So the important thing is how to minimize the environmental pollution from the blasting. There should be regulations in order that the standard limitation is not exceeded, and to decrease the environmental pollution from the blasting.

사워가스 처리기술 및 제거기술 (The Sour Gas Treatment and Removal Technology)

  • 김영철;조진동;오창섭
    • 에너지공학
    • /
    • 제25권1호
    • /
    • pp.171-176
    • /
    • 2016
  • 신흥 선진국들의 급격한 에너지소비 증가와 청정에너지 자원의 고갈로 인해 현재 개발 단가가 높은 미개발 오일 가스 저유지를 개발하고 있는데 이들 오일 가스전은 다량의 부식성 황 화합물($H_2S$)과 $CO_2$, 부탄, 메르캅탄(mercaptan)등을 함유하고 있다. $H_2S$ 가스는 인체에 치명적인 영향을 미치는 독성가스 중 하나이며, $CO_2$ 가스는 지구 온난화에 영향을 가장 많이 미치고 있는 온실가스 중 하나이다. 이러한 유전과 가스전 개발에는 특수 장비와 작업을 안전하게 할 수 있는 고도의 기술력이 필수적이기 때문에 선진국들은 $H_2S/CO_2$ 가스를 함유하고 있는 사워가스/산성가스 처리와 제거기술을 개발하고 있다. 가스전의 가스(raw gas) 처리기술은 저유지의 특성 및 가스에 함유된 $H_2S$의 구성요소들에 의해 좌우된다. 여기서는 많은 양의 황산을 함유하고 있는 오일과 가스에 대한 효율적인 처리 및 처리 비용 그리고 분리장치 기술 및 생산시스템에 관한 문제에 대해서 서술하고자 한다.

프로판/이소부탄 혼합냉매를 적용한 가정용 냉장고의 성능에 관한 연구 (Performance Evaluation of Propane(R290)/Isobutane(R600a) Mixture as a Substitute for CFC12 in Domestic Refrigerators)

  • 임병한;박윤범;유환규;정동수;김종보
    • 설비공학논문집
    • /
    • 제7권2호
    • /
    • pp.249-265
    • /
    • 1995
  • The performance of a refrigerant mixture of propane(R290)/isobutane(R600a) as a substitute for CFC12 was investigated in a domestic refrigerator with single evaporator. A thermodynamic cycle simulation indicated an increase in COP of a 1.7 to 2.4% with R-290/600a in the composition range of 0.2 to 0.6 mass fraction of R290 compared to CFC12. For the tests, two units($299{\ell}$, $465{\ell}$) were used. All refrigeration components remained the same throughout the tests, except that the length of capillary tube and amount of charge were changed for the mixture. The refrigerators were fully instrumented with more than 20 thermocouples, 2 pressure transducers, and watt/watt-hour meter for each refrigerator. 'Energy consumption test' and 'no load pulldown test' were performed under the same condition. The experimental results obtained with the same compressor indicated that R-290/600a mixture at 0.6 mass fraction of R290 showed a 3 to 5% increase in energy efficiency and a faster cooling speed compared to CFC12. The R-290/600a mixture showed a shorter compressor on-time and a lower compressor dome temperature than CFC12. In conclusion, the proposed hydrocarbon mixture seems to be an appropriate candidate to replace CFC12 without causing more environmental problems.

  • PDF

유체마찰에너지를 이용한 풍력열발생조의 성능 분석 (Performance Analysis of the Wind Power Heat Generation Drum Using Fluid Frictional Energy)

  • Kim, Yeong-Jung;Yu, Yeong-Seon;Gang, Geum-Chun;Baek, Lee;Yun, Jin-Ha;Lee, Geon-Jung
    • Journal of Biosystems Engineering
    • /
    • 제26권3호
    • /
    • pp.263-270
    • /
    • 2001
  • This study was conducted in order to develop wind-water heating system where frictional heat is creased between the rotor and working fluid when they are rotating in the cylindrical heat generator. The wind-water heating system is composed of rotor, stator, working fluid, motor, inverter and heat generation tank. Instead of wind turbine, we have used an electrical motor of 30㎾ to rotate the rotor in this system. Two working fluids and six levels of rotor rpm were tested to quantify heat amounts generated by the system. Generally, as motor rpm goes up heat amount increases that we have expected. At the same rpm, viscous fluid showed up better performance than the water, generating more heat by 10$\^{C}$ difference. The greatest heat amount of 31,500kJ/h was obtained when the system constantly drained out the hot water of at the flow rate of 500ℓ/h. Power consumption rate of the motor was measured by thee phase electric power meter where the largest power consumption rate was 14㎾ when motor rpm was 600 and gained heat was 31,500kJ/h, that indicated total thermal efficiency of the wind power water heating system was 62%.

  • PDF

그린홈 보급확대를 위한 건물용 연료전지 보조기기의 성능 향상 (Performance improvement of BOP Components for 1kW Stationary Fuel Cell Systems to Promote Green-Home Dissemination Project)

  • 이선호;김동하;김민석;전희권
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.89.1-89.1
    • /
    • 2011
  • According to green growth's policy, green-home dissemination's projects are promoting. Among them, stationary fuel cell systems are receiving attention due to high efficiency and clear energy. But it need absolutely to develop cost down technologies and improve system durability for commercialization of the fuel cell system. To achieve this objectives, in 2009, the Korean Government and "Korea Institute of Energy Technology Evaluation and Planning(KETEP)" launched into the strategic development project of BOP technology for practical applications and commercializations of stationary fuel cell systems, named "Technology Development on Cost Reduction of BOP Components for 1kW Stationary Fuel Cell Systems to Promote Green-Home Dissemination Project". This paper introduces a summary of improved BOP performances that has been achieved through the 2nd year development precesses(2010.06~2011.05) base on 1st year development precesses(2009.06~2010.05). The major elements for fuel cell systems are cathode air blowers, burner air blowers, preferential oxidation air blowers, fuel blowers, cooling water pumps, reformer water pumps, heat recovery pumps, mass flow meters, electrical valves, safety valves and a low-voltage inverter. Key targets of those elements are the reduction of cost, power consumption and noise. Invert's key targets are development the low -voltage technologies in order to reduce the number of unit cell in fuel cell system's stack.

  • PDF