• Title/Summary/Keyword: energy loads

Search Result 1,471, Processing Time 0.026 seconds

Environmental Load Assessment of Municipal Solid Waste using LCA (LCA를 통한 도시 고형 페기물의 환경부하평가)

  • ;Susumu Tohno;Mikio Kasshara
    • Journal of Environmental Science International
    • /
    • v.12 no.6
    • /
    • pp.643-650
    • /
    • 2003
  • We analyzed the amount of environmental loads, and the amount of energy consumption through life cycle assessment from a discharge stage to the ultimate disposal to municipal solid waste in Seoul. We carried out inventory analysis of the amount of environmental loads that made the object range collection, intermediate treatment, and the final treatment, and took into consideration each stage exceptions CO$_2$ and NOx , the amount of SOx discharge, and energy consumption. We applied the data of an object model, and acquisition processed the scale of an object model suitably and applied to it to difficult data using the data of the Yokohama City incineration plant in Japan. The amount of environmental loads per Iton of municipal waste were analyzed CO$_2$ 0.4C-ton, SOx 0.4kg and NOx 0.8kg. Moreover, the amount of energy consumption which is 2.4Gcal was computed.

Analysis of energy and daylight performance of adjustable shading devices in region with hot summer and cold winter

  • Freewan, Ahmed A.;Shqra, Lina W.
    • Advances in Energy Research
    • /
    • v.5 no.4
    • /
    • pp.289-304
    • /
    • 2017
  • Large glazed surfaces and windows become common features in modern buildings. The spread of these features was influenced by the dependence of designers on mechanical and artificial systems to provide occupants with thermal and visual comfort. Countries with hot summer and cold winter conditions, like Jordan, require maximum shading from solar radiation in summer, and maximum exposure in winter to reduce cooling and heating loads respectively. The current research aims at designing optimized double-positioned external shading device systems that help to reduce energy consumption in buildings and provide thermal and visual comfort during both hot and cold seasons. Using energy plus, a whole building energy simulation program, and radiance, Lighting Simulation Tool, with DesignBuilder interface, a series of computer simulations for energy consumption and daylighting performance were conducted for offices with south, east, or west windows. The research was based on comparison to determine the best fit characteristics for two positions of adjustable horizontal louvers on south facade or vertical fins on east and west facades for summer and winter conditions. The adjustable shading systems can be applied for new or retrofitted office or housing buildings. The optimized shading devices for summer and winter positions helped to reduce the net annual energy consumption compared to a base case space with no shading device or with curtains and compared to fix shading devices.

Prediction of Wave Energy Absorption Efficiency and Wave Loads of a Three-Dimensional Bottom-Mounted OWC Wave Power Device (착저식 OWC 파력발전장치의 파에너지 흡수효율 및 파랑하중 계산)

  • Hong, Do-Chun;Hong, Key-Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.47-52
    • /
    • 2010
  • The wave energy absorption efficiency and the first-order and the time-mean second-order wave loads of a three-dimensional bottom-mounted oscillating water column (OWC) chamber structure are studied. The potential problem is solved by making use of a hybrid Green integral equation associated with the finite-waterdepth free-surface Green function outside a twin chamber and the Rankine Green function inside taking account of the fluctuating air pressure inside the chamber. Numerical results of the primary wave energy converting efficiency and the oscillating and steady wave loads of a three-dimensional bottom-mounted OWC pilot plant have been presented.

A Study on the Effects of Turbulence to Ultimate Loads Acting on the Blade of Wind Turbine (풍력발전시스템의 블레이드에 작용하는 극한하중에 대한 난류의 영향 연구)

  • Hyun, Seung-Gun;Kim, Keon-Hoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.7-14
    • /
    • 2013
  • This study has analysed the ultimate loads acting on a wind turbine which is operating in a high turbulent flow condition because the ultimate loads are critical factors on the safe design of wind turbine. Since wind flow on the most parts of Korean mountainous are strongly influenced by complex configurations of the topography, turbulence intensity on somewhere is so stronger than an international design standard. For this reason, the characteristics of turbulent wind data collected from actual sites were analyzed and used for the ultimate load evaluation of the wind turbine. With the 270 design load cases on the international standards, the differences of ultimate loads on the wind turbine operating in the standard or high turbulent wind condition are calculated and compared for the an enhanced knowledge of the safe design basis. As are result, it is revealed the specific ultimate loads are strongly affected by the high turbulent wind conditions, thus the characteristics of turbulent flow must be considered during the design of wind turbine.

Microgrid energy scheduling with demand response

  • Azimian, Mahdi;Amir, Vahid;Haddadipour, Shapour
    • Advances in Energy Research
    • /
    • v.7 no.2
    • /
    • pp.85-100
    • /
    • 2020
  • Distributed energy resources (DERs) are essential for coping with growing multiple energy demands. A microgrid (MG) is a small-scale version of the power system which makes possible the integration of DERs as well as achieving maximum demand-side management utilization. Hence, this study focuses on the analysis of optimal power dispatch considering economic aspects in a multi-carrier microgrid (MCMG) with price-responsive loads. This paper proposes a novel time-based demand-side management in order to reshape the load curve, as well as preventing the excessive use of energy in peak hours. In conventional studies, energy consumption is optimized from the perspective of each infrastructure user without considering the interactions. Here, the interaction of energy system infrastructures is considered in the presence of energy storage systems (ESSs), small-scale energy resources (SSERs), and responsive loads. Simulations are performed using GAMS (General Algebraic modeling system) to model MCMG, which are connected to the electricity, natural gas, and district heat networks for supplying multiple energy demands. Results show that the simultaneous operation of various energy carriers, as well as utilization of price-responsive loads, lead to better MCMG performance and decrease operating costs for smart distribution grids. This model is examined on a typical MCMG, and the effectiveness of the proposed model is proven.

Thermal and Stress Analysis of The Faraday Shield in KSTAR ICH System

  • Yoon, B.J.;Han, J.M.;Jeong, S.H.;Yoon, J.S.;Hong, B.G.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.935-940
    • /
    • 1998
  • The Korea Superconducting Tokamak Research (KSTAR) tokamak will have 6 MW of radio-frequency (rf) heating in the ion cyclotron range of frequencies (ICRF). The response of the antenna to the heat loads is analyzed and the resulting stresses in the Faraday shield during the normal operation is calculated. Various heat loading conditions including in the analyzes are the heat loads from the plasma, the ripple-trapped beam particles and the rf loss.

  • PDF

A spectral model for human bouncing loads

  • Jiecheng Xiong;Jun Chen
    • Structural Engineering and Mechanics
    • /
    • v.86 no.2
    • /
    • pp.237-247
    • /
    • 2023
  • Fourier series-based models in the time domain are frequently established to represent individual bouncing loads, which neglects the stochastic property of human bouncing activity. A power spectral density (PSD) model in the frequency domain for individual bouncing loads is developed herein. An experiment was conducted on individual bouncing loads, resulting in 957 records linked to form long samples to achieve a fine frequency resolution. The Welch method was applied to the linked samples to obtain the experimental PSD, which was normalized by the bouncing frequency and the harmonic order. The energy, energy distribution center, and energy distribution shape of the experimental PSD were investigated to establish the PSD model. The proposed model was used to analyze structural vibration responses using stochastic vibration theory, which was verified via field measurements. It is believed that this framework can evaluate the vibration capacity of structures excited by bouncing crowds, such as concert halls and grandstands.

Load Measurements of 100 kW Wind Turbine (100 kW급 풍력발전기의 하중 측정)

  • Bae, Jae-Sung;Kim, Sung-One;Kyong, Nam-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.27-33
    • /
    • 2004
  • Mechanical load measurements on blade and tower of Vestas 100 kW wind turbine has been reformed in Wollyong test site, Jeju island. The experimental procedure for the measurement of wind turbine loads, such as edgewise(lead-lag) bending moment, flapwise bending moment, and tower base bending moment, has been established. The test facilities consisting of strain-gauges, telemetry and T-Mon system are installed in the wind turbine. Strain gauges are on-site calibrated against load cell prior to monitoring the wind turbine loads. Using the test setup, the loads on the components are being measured and analysed for various external conditions of the wind turbine. A set of results for near rated wind speed has been presented in this paper.

A study on the Dynamic Fracture Toughness for Polymeric Materials (폴리머재료의 파괴인성치에 관한 연구)

  • 최영식;박명균
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2001.05a
    • /
    • pp.311-317
    • /
    • 2001
  • The notched Charpy and Izod impact tests are the most prevalent techniques used to characterize the effects of high impulse loads on ploymeric materials. An analysis method for rubber toughened PVC is suggested to evaluate critical strain energy release rates(Gc) from the Charpy impact energy measurements. An Instrumented Charpy Impact tester was used to extract ancillary information concerning fracture properties in addition to total fracture properties and maximum critical loads. The stress intensity factor Kd was computed for varying amounts of rubber contents from the obtained maximum critical loads and also toughening effects were investigated as well.

  • PDF

An Analysis on Fracture Behavior of Aluminum Foil and Paper by Linear Elastic Fracture Mechanics (선형파괴역학에 의한 Aluminum Foil과 종이의 파괴거동 해석)

  • An, Deuk-Man;Ok, Young-Gu
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.159-164
    • /
    • 2000
  • The fracture behaviors of aluminum foils and sheet papers were analyzed on the basis of linear elastic fracture mechanics(LEFM). The fracture loads of the similarly shaped specimens were calculated by dimensional analysis. The actual fracture loads were measured using the simple tension equipment. The predicted fracture loads were compared with the experimental results.

  • PDF